Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry
Open accessThe DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index; 15 of the 36 sources its claims cite were checked for support.
Abstract
Advanced in vitro culture from tissues of different origin includes three-dimensional (3D) organoid micro structures that may mimic conditions in vivo. One example of simple 3D culture is spheroids; ball shaped structures typically used as liver and tumour models. Oxygen is critically important in physiological processes, but is difficult to quantify in 3D culture: and the question arises, how small does a spheroid have to be to have minimal micro-environment formation? This question is of particular importance in the growing field of 3D based models for toxicological assessment. Here, we describe a simple non-invasive approach modified for the quantitative measurement and subsequent evaluation of oxygen gradients in spheroids developed from a non-malignant fish cell line (i.e. RTG-2 cells) using Electron Paramagnetic Resonance (EPR) oximetry. Sonication of the paramagnetic probe Lithium phthalocyanine (LiPc) allows for incorporation of probe particulates into spheroid during its formation. Spectra signal strength after incorporation of probe into spheroid indicated that a volume of 20 μl of probe (stock solution: 0.10 mg/mL) is sufficient to provide a strong spectra across a range of spheroid sizes. The addition of non-toxic probes (that do not produce or consume oxygen) report on oxygen diffusion throughout the spheroid as a function of size. We provide evidence supporting the use of this model over a range of initial cell seeding densities and spheroid sizes with the production of oxygen distribution as a function of these parameters. In our spheroid model, lower cell seeding densities (∼2,500 cells/spheroid) and absolute size (118±32 μm) allow control of factors such as pre-existing stresses (e.g. ∼ 2% normoxic/hypoxic interface) for more accurate measurement of treatment response. The applied methodology provides an elegant, widely applicable approach to directly characterize spheroid (and other organoid) cultures in biomedical and toxicological research.
Overview
CoChat Summary
TL;DR
This paper demonstrates non-invasive Electron Paramagnetic Resonance (EPR) oximetry using sonicated lithium phthalocyanine (LiPc) to measure oxygen gradients in RTG-2 fish-cell spheroids. It finds that smaller spheroids and lower seeding densities minimize hypoxic/necrotic micro-environments, supporting their use for toxicological 3D models.
Key findings
- Spheroids formed around LiPc probe particulates; 20 µL of 0.10 mg/mL probe gave strong spectra, and 5 h sonication produced particulates of 11.20 ± 1.02 μm.
- Oxygen gradients depended on seeding density, size, and time. For 2,500 cells/spheroid at day 7, ΔO₂ was 88%, radius 67 ± 32 μm, viable rim 59 μm, hypoxic zone 8 μm; at day 14, ΔO₂ was 45%, viable rim 30 μm, hypoxic zone 37 μm. For 80,000 cells/spheroid at day 7, ΔO₂ was 22%, radius 350 ± 117 μm, viable rim 77 μm, hypoxic zone 273 μm.
- The paper recommends working with spheroids below 100–150 μm diameter to limit hypoxia/necrosis; it states that <2% hypoxic/necrotic area allows for presence of senescent cells, and that lower seeding densities (~2,500 cells/spheroid) and absolute size (118 ± 32 μm) allow control of pre-existing stresses.
- Oxygen consumption rate for a ~120 μm spheroid on day 7 followed −2.21T + 623.77 (R² = 0.91) over 160 min, with a linear range in the first 50 min corresponding to 178–101 μM oxygen; spheroids could not consume oxygen linearly below 100 μM.
Methods
- RTG-2 rainbow trout gonad cells were seeded at 2,500–80,000 cells/spheroid in pHEMA-coated 96-well U-bottom plates with 20 µL LiPc probe, then maintained under orbital shaking; spheroids formed by day 7.
- EPR oximetry was performed at 9.4 GHz and 292 K using PTFE tubing; oxygen was quantified from peak-to-peak linewidth relative to fully oxygenated probe/media, with calibration curves.
- Oxygen consumption rate was measured in sealed glass capillaries with ~5 µL media per spheroid (n = 5), recording spectra every 3 min for 160 min; statistical analysis used Friedman non-parametric test (n = 3, p < 0.05).
Limitations
- The paper states that OCR kinetics could not be recorded accurately for the first 7–10 min due to inherent linewidth variation, and that part of the oxygen-sensitive LiPc may convert to an oxygen-insensitive form; it also notes the need to calibrate each LiPc batch due to probe purity differences.
- The paper states assumptions that the spheroid is spherical for even oxygen uptake and that oxygen is calculated as a percentage of all probe particulates irrespective of location, despite heterogeneous distribution due to particulate size.
- Evident from the text: the study uses a single non-malignant fish cell line (RTG-2), reports n = 3 for main comparisons, and notes difficulty comparing directly with partial-pressure measurements from other 3D oximetry studies because of different cell lines, temperatures, and parameters.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
12 Valid · 0 Not valid · 10 Not checked · 33 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The formation of micro-environments within spheroids growing under in vitro conditions is determined by the balance between oxygen diffusion from the growth medium and its consumption within the spheroid.”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Introduction
What the sources say
- Not checked — no full text of the sourcecites [16] 16. Diepart C, Verrax J, Calderon PB, Feron O, Jordan BF, Gallez B. Comparison of methods for measuring oxygen consumption in tumor cells in vitro. Anal Biochem. 2010; 396(2): 250– 256. Available from: 10.1016/j.ab.2009.09.029. 10.1016/j.ab.2009.09.029 19766582 source
- Partly supportedcites [17] 17. Krohn KA, Link JM, Mason RP. Molecular Imaging of Hypoxia. J Nucl Med. 2008 6; 49(Suppl_2): 129S– 148S. Available from: http://jnm.snmjournals.org/cgi/doi/10.2967/jnumed.110.075663 http://jnm.snmjournals.org/cgi/doi/10.2967/jnumed.107.045914. 10.2967/jnumed.107.045914 18523070 sourceExperimental — accuracy not yet measured
The Fluoromisonidazole: Preclinical Studies section describes cultured spheroids with a well-oxygenated periphery, an intermediate hypoxic zone, and a necrotic center. It does not state that the balance between oxygen diffusion from the growth medium and consumption within the spheroid determines those regions (no page number is available in our copy). (LLM, conf=0.84)
- Partly supportedcites [18] 18. Mueller-Klieser WF, Sutherland RM. Oxygen tensions in multicell spheroids of two cell lines. Br J Cancer. 1982; 45(2): 256– 264. 10.1038/bjc.1982.41 7059474 PMC2010909 sourceExperimental — accuracy not yet measured
The discussion around Fig. 4 explains that nutrients diffuse into spheroids from the surrounding medium and relates their supply to consumption by viable cells. It also says that glucose and other factors affect oxygen levels and that which substrate controls cellular conditions is difficult to determine. The source therefore supports the diffusion–consumption mechanism for oxygen gradients, but not oxygen alone as the determinant of spheroid microenvironments. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“It should be noted that there is little consensus in the literature on the most appropriate method to use due to recently documented difficulties/limitations of these methods [23].”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Introduction
What the sources say
- Partly supportedcites [23] 23. Miniaev MV, Belyakova MB, Kostiuk NV, Leshchenko DV, Fedotova Ta. Non-obvious problems in clark electrode application at elevated temperature and ways of their elimination. J Anal Methods Chem. 2013; 2013 10.1155/2013/249752 23984188 PMC3747604 sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) describes limitations of Clark electrodes, including unstable readings, signal drift and changing response times. It does not assess competing methods, establish a lack of consensus about which method is most appropriate, or address oxygen micro-environments in tumour spheroids. (LLM, conf=0.83)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
Every source the paper cites for this claim was checked and supports it.
In the paper
“The occurrence of this zone of senescence lends support to the suggestion that necrotic cells arising as quiescent cells die as noted by previous studies [51].”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
What the sources say
- Supportedcites [51] 51. Wallace DI, Guo X. Properties of tumor spheroid growth exhibited by simple mathematical models. Front Oncol. 2013; 3(March): 51 Available from: http://www.frontiersin.org/Journal/10.3389/fonc.2013.00051/abstract. 10.3389/fonc.2013.00051 23508803 PMC3598098 source
In the Introduction’s ‘Development of models’ section (page unavailable), the paper describes a layer of quiescent cells and says they die after sufficient lack of nutrients. The Discussion (page unavailable) describes the model’s transition from quiescent to necrotic cells and its resulting three layers, supporting the cited suggestion. (LLM, conf=0.88)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Our study highlights the important association between size and the formation of oxygen limited environments (hypoxia) within the spheroid system, a finding which has already been illustrated in the literature for tumour derived spheroid models [49, 50] but nevertheless has remained unknown till now in the non tumour models.”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
What the sources say
- Supportedcites [49] 49. Ho WY, Yeap SK, Ho CL, Rahim RA, Alitheen NB. Development of Multicellular Tumor Spheroid (MCTS) Culture from Breast Cancer Cell and a High Throughput Screening Method Using the MTT Assay. PLoS One. 2012; 7(9). 10.1371/journal.pone.0044640 PMC3435305 22970274 source
The Results section on LDH release (page unavailable) says the oxygen-deprived central region varies with spheroid size, supporting the cited association in tumour spheroids. The Introduction (page unavailable) also describes oxygen gradients and hypoxic microregions within these spheroids. The citing paper's claim about non-tumour models is presented as its own finding, not attributed to this source. (LLM, conf=0.86)
- Not matchedcites [50] 50. Sutherland R, Carlsson J, Durand R, Yuhas J. Spheroids in Cancer Research. Cancer Res. 1981; 41(7): 2980– 2984. Available from: http://cancerres.aacrjournals.org/content/41/7/2980.abstract.
We searched by its title and found no matching paper.
boostedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“One advantage which EPR based methodology has over normal micro-electrode measurements is that linewidth of spectra is based on pure physical interaction between paramagnetic probe molecules and oxygen within the biological system [27].”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
What the sources say
- Partly supportedcites [27] 27. Khramtsov VV. In vivo Spectroscopy and Imaging of Nitroxide Probes. 2012;. sourceExperimental — accuracy not yet measured
Section 2.1 (page not available) says EPR oximetry relies on a physical interaction between paramagnetic probes and oxygen, and describes oxygen-induced spectral broadening. It does not compare this advantage with micro-electrode measurements, so that comparative part is not supported by our copy. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
21 more claims · 1 with their cited sources checked
Create a free account to see all 55 claims and to verify the 1 reference still open.
- Probably not a substantial claim. 13
- It may state two separate claims as one. 19
- The quote only partly states this claim. 2
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
“A decrease in oxygen concentration relative to time is explained by the formula -2.21T+623.77 (R2 = 0.91), where μmole of oxygen is represented by μM and T is in minutes (160 min) and where the linear range occurs within the first 50 minutes.”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
“This linear range corresponds to an oxygen concentration range of 178-101μM.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Results and Discussion
“Percentage oxygen concentration within the spheroid model was determined by linewidth difference in sample versus completely oxygenated probe in media (n = 3) and was observed to narrow as expected with time and decreased oxygen availability (Table 1).”
§ Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry > Methods > Validation of spheroid formation with paramagnetic probe
“| 60,000 | 7 | 28 | 300 ± 62 | 84 | 216 | | | 14 | 45 | | 135 | 165 | | 80,000 | 7 | 22 | 350 ± 117 | 77 | 273 | | | 14 | 26 | | 91 | 259 |”
Citations
Cites
(1989) · PubMed · Cited by 3,343
Neutral red uptake assay for the estimation of cell viability/cytotoxicity
Repetto, G., del Peso, A., & Zurita, J. L. (2008) · Nature Protocols · doi:10.1038/nprot.2008.75 · Cited by 2,207
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742 · cited 2×
“Over the past three decades, the use of three dimensional cell culture (e.g. spheroids) has gained increased recognition as an important tool in biological research and in preclinical trials [1 – 3] over conventional organs or ex vivo cultures which are unsurprisingly in short supply.”
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Three-dimensional cell culture: the missing link in drug discovery
Breslin, S., & O’Driscoll, L. (2013) · Drug Discovery Today · doi:10.1016/j.drudis.2012.10.003 · Cited by 1,332 · cited 1×
“There is an enormous body of literature on spheroid models and their use in cancer therapy orientated studies (3D tumour models) to bridge the gap between cell based assays and in vivo studies [6 – 8].”
Recent advances in three‐dimensional multicellular spheroid culture for biomedical research
Lin, R., & Chang, H. (2008) · Biotechnology Journal · doi:10.1002/biot.200700228 · Cited by 1,264 · cited 1×
“exposure) on day 7 (in both aquatic and mammalian based spheroids), due to a change in cellular structure from loose aggregate to spheroid [2, 11].”
Opportunities and challenges for use of tumor spheroids as models to test drug delivery and efficacy
Mehta, G., Hsiao, A. Y., Ingram, M., Luker, G. D., & Takayama, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.04.045 · Cited by 1,172 · cited 1×
“Unlike mammalian tumour cell lines which have been well studied in our group [35, 36], with well defined micro-environments (see [10]), little information exists on spheroids derived from non-tumour sources in terms of spheroid heterogeneity.”
Spheroid culture as a tool for creating 3D complex tissues
Fennema, E., Rivron, N., Rouwkema, J., van Blitterswijk, C., & de Boer, J. (2013) · Trends in Biotechnology · doi:10.1016/j.tibtech.2012.12.003 · Cited by 1,054
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Established eurythermic line of fish cells in vitro
Wolf, K., & Quimby, M. C. (1962) · Science · doi:10.1126/science.135.3508.1065 · Cited by 638
3D Cell Culture: A Review of Current Approaches and Techniques
Haycock, J. W. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-60761-984-0_1 · Cited by 534
Krohn, K. A., Link, J. M., & Mason, R. P. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045914 · Cited by 506
Cheng, G., Tse, J., Jain, R. K., & Munn, L. L. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004632 · Cited by 478
Liu, K. J., Gast, P., Moussavi, M., Norby, S. W., Vahidi, N., Walczak, T., Wu, M., & Swartz, H. M. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.12.5438 · Cited by 318 · cited 2×
“A suggested reason for this disparity between recorded values herein and the literature lies in the purity of the paramagnetic probe, with impure probe particulates reporting different mGauss sensitivity, as previously observed [34].”
Glicklis, R., Merchuk, J. C., & Cohen, S. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20086 · Cited by 316 · cited 4×
“Previous studies have theorized optimal spheroid diameter in non-tumour mammalian spheroids which allows for effective diffusion of oxygen through the spheroid based on cell viability and functionality [5, 55].”
InfluentialA reliable tool to determine cell viability in complex 3-d culture: the acid phosphatase assay
Friedrich, J., Eder, W., Castaneda, J., Doss, M., Huber, E., Ebner, R., & Kunz-Schughart, L. A. (2007) · SLAS DISCOVERY · doi:10.1177/1087057107306839 · Cited by 227 · cited 1×
“Oxygen micro-environments are known to form within tumour spheroid models as a function of culture time and initial seeding densities of cells and spheroid size [46].”
Ma, H.-L., Jiang, Q., Han, S., Wu, Y., Tomshine, J. C., Wang, D., Gan, Y., Zou, G., & Liang, X.-J. (2012) · Molecular Imaging · doi:10.2310/7290.2012.00012 · Cited by 182
(1984) · Recent Results in Cancer Research · doi:10.1007/978-3-642-82340-4 · Cited by 176
WARTENBERG, M., DÖNMEZ, F., LING, F. C., ACKER, H., HESCHELER, J., & SAUER, H. (2001) · The FASEB Journal · doi:10.1096/fj.00-0350com · Cited by 174
Ho, W. Y., Yeap, S. K., Ho, C. L., Rahim, R. A., & Alitheen, N. B. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044640 · Cited by 173 · cited 1×
“Our study highlights the important association between size and the formation of oxygen limited environments (hypoxia) within the spheroid system, a finding which has already been illustrated in the literature for tumour derived spheroid models [49, 50] but nevertheless has remained unknown till now in the non tumour…”
Theory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry
Ahmad, R., & Kuppusamy, P. (2010) · Chemical Reviews · doi:10.1021/cr900396q · Cited by 166
Novel particulate spin probe for targeted determination of oxygen in cells and tissues
Pandian, R. P., Parinandi, N. L., Ilangovan, G., Zweier, J. L., & Kuppusamy, P. (2003) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(03)00496-9 · Cited by 150
Mueller-Klieser, W. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84030-8 · Cited by 146
Chitneni, S. K., Palmer, G. M., Zalutsky, M. R., & Dewhirst, M. W. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075663 · Cited by 137
Oxygen diffusion and reaction kinetics in the photodynamic therapy of multicell tumour spheroids
Nichols, M. G., & Foster, T. H. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/12/003 · Cited by 136
Oxygen tensions in multicell spheroids of two cell lines
Mueller-Klieser, W. F., & Sutherland, R. M. (1982) · British Journal of Cancer · doi:10.1038/bjc.1982.41 · Cited by 133 · cited 2×
“While this relationship has been well established in tumour biology [16 – 18], there appears to be no studies addressing this directly in non-tumour models.”
Monitoring pH and dissolved oxygen in mammalian cell culture using optical sensors
Naciri, M., Kuystermans, D., & Al-Rubeai, M. (2008) · Cytotechnology · doi:10.1007/s10616-008-9160-1 · Cited by 111
Backer, J. M., Budker, V. G., Eremenko, S. I., & Molin, Y. N. (1977) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(77)90161-x · Cited by 101
Comparison of methods for measuring oxygen consumption in tumor cells in vitro
Diepart, C., Verrax, J., Calderon, P. B., Feron, O., Jordan, B. F., & Gallez, B. (2010) · Analytical Biochemistry · doi:10.1016/j.ab.2009.09.029 · Cited by 92
Three-dimensional co-culture of hepatocytes and stellate cells
Abu-Absi, S. F., Hansen, L. K., & Hu, W.-S. (2004) · Cytotechnology · doi:10.1007/s10616-004-7996-6 · Cited by 92 · cited 1×
“Previous studies have theorized optimal spheroid diameter in non-tumour mammalian spheroids which allows for effective diffusion of oxygen through the spheroid based on cell viability and functionality [5, 55].”
Absolute oxygen tension (pO2) in murine fatty and muscle tissue as determined by EPR
Matsumoto, A., Matsumoto, S., Sowers, A. L., Koscielniak, J. W., Trigg, N. J., Kuppusamy, P., Mitchell, J. B., Subramanian, S., Krishna, M. C., & Matsumoto, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20714 · Cited by 92 · cited 1×
“One of the most important characteristics of this approach is that it does not interfere with oxygen metabolism within the biological system, therefore providing a basis for non-invasive oxygen measurements in biological systems [33], a critical requirement for measurement of oxygen within 3D models [29].”
Generation of multicellular tumor spheroids of breast cancer cells: How to go three-dimensional
Nagelkerke, A., Bussink, J., Sweep, F. C. G. J., & Span, P. N. (2013) · Analytical Biochemistry · doi:10.1016/j.ab.2013.02.004 · Cited by 89
Oxygen consumption dynamics in steady-state tumour models
Grimes, D. R., Fletcher, A. G., & Partridge, M. (2014) · Royal Society Open Science · doi:10.1098/rsos.140080 · Cited by 84
Liu, J., Kuznetsova, L. A., Edwards, G. O., Xu, J., Ma, M., Purcell, W. M., Jackson, S. K., & Coakley, W. T. (2007) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21345 · Cited by 83
Self-citationRaisuddin, S., & Jha, A. N. (2004) · Environmental and Molecular Mutagenesis · doi:10.1002/em.20027 · Cited by 79
Self-citationProperties of Tumor Spheroid Growth Exhibited by Simple Mathematical Models
Wallace, D. I., & Guo, X. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00051 · Cited by 77 · cited 1×
“The occurrence of this zone of senescence lends support to the suggestion that necrotic cells arising as quiescent cells die as noted by previous studies [51].”
Protein Synthesis and Oxygen Consumption in Fish Cells
Smith, R. W., & Houlihan, D. F. (1995) · Journal of Comparative Physiology B · doi:10.1007/bf00301473 · Cited by 76
The Effects of Endotoxin on Oxygen-Consumption of various Cell-Types In-Vitro—an EPR Oximetry Study
James, P. E., Jackson, S. K., Grinberg, O. Y., & Swartz, H. M. (1995) · Free Radical Biology and Medicine · doi:10.1016/0891-5849(94)00179-n · Cited by 70
Self-citationTrityl-based EPR probe with enhanced sensitivity to oxygen
Bobko, A. A., Dhimitruka, I., Eubank, T. D., Marsh, C. B., Zweier, J. L., & Khramtsov, V. V. (2009) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2009.06.007 · Cited by 63
Baron, M. G., Purcell, W. M., Jackson, S. K., Owen, S. F., & Jha, A. N. (2012) · Ecotoxicology · doi:10.1007/s10646-012-0965-5 · Cited by 58
Self-citationAnaphase aberrations: a measure of genotoxicity in mutagen-treated fish cells
Kocan, R. M., Landolt, M. L., & Sabo, K. M. (1982) · Environmental Mutagenesis · doi:10.1002/em.2860040208 · Cited by 57
Ilangovan, G., Li, H., Zweier, J. L., & Kuppusamy, P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010130+ · Cited by 51 · cited 2×
“Prior studies have suggested that it is simply related to the size of the particulate used, and to increase spectra strength, fine tuning of paramagnetic particulate size must be employed for the specific model under investigation [45, 54].”
Papis, E., Davies, S. J., & Jha, A. N. (2010) · Ecotoxicology · doi:10.1007/s10646-010-0572-2 · Cited by 48
Self-citationEPR Oximetry in Biological and Model Samples
Subczynski, W. K., & Swartz, H. M. (2006) · Springer eBooks · doi:10.1007/0-387-26741-7_10 · Cited by 42
Ma, M., Xu, J., & Purcell, W. M. (2003) · Journal of Cellular Biochemistry · doi:10.1002/jcb.10730 · Cited by 36
Self-citationPresley, T., Kuppusamy, P., Zweier, J. L., & Ilangovan, G. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.090175 · Cited by 34 · cited 2×
“Prior studies have suggested that it is simply related to the size of the particulate used, and to increase spectra strength, fine tuning of paramagnetic particulate size must be employed for the specific model under investigation [45, 54].”
Electron spin resonance microscopic imaging of oxygen concentration in cancer spheroids
Hashem, M., Weiler-Sagie, M., Kuppusamy, P., Neufeld, G., Neeman, M., & Blank, A. (2015) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2015.04.012 · Cited by 25
Dobrucki, J. W., Sutherland, R. M., & Swartz, H. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910190105 · Cited by 23
RNA turnover and protein synthesis in fish cells
Smith, R. W., Palmer, R. M., & Houlihan, D. F. (2000) · Journal of Comparative Physiology B · doi:10.1007/s003600050268 · Cited by 19
Miniaev, M. V., Belyakova, M. B., Kostiuk, N. V., Leshchenko, D. V., & Fedotova, T. A. (2013) · Journal of Analytical Methods in Chemistry · doi:10.1155/2013/249752 · Cited by 18 · cited 1×
“It should be noted that there is little consensus in the literature on the most appropriate method to use due to recently documented difficulties/ limitations of these methods [23].”
LIFE SCIENCE TECHNOLOGIES: Animal-Free Toxicology: Sometimes, in Vitro is Better
Perkel, J. M. (2012) · Science · doi:10.1126/science.335.6072.1122 · Cited by 14
Use of Electron Spin Resonance Spectrometry in Microscopy, Dating and Dosimetry A Review
Ikeya, M. (1989) · Analytical Sciences · doi:10.2116/analsci.5.5 · Cited by 13
[Toxicity assessment of waste water samples with fish cell lines]
Schulz, M., Lewald, B., Kohlpoth, M., Rusche, B., Lorenz, K. H. J., Unruh, E., Hansen, P., & Miltenburger, H. G. (1995) · PubMed · Cited by 13
In vivo Spectroscopy and Imaging of Nitroxide Probes
V., V. (2012) · Nitroxides - Theory, Experiment and Applications · doi:10.5772/39129 · Cited by 8 · cited 2×
“The method is based on the Heisenberg spin exchange between paramagnetic molecules of probe and oxygen causing a change in linewidth of the EPR spectrum of the probe [27, 31, 32].”
Hyodo, F., Matsumoto, S., Hyodo, E., Matsumoto, A., Matsumoto, K., & Krishna, M. C. (2010) · Methods in molecular biology · doi:10.1007/978-1-60327-029-8_2 · Cited by 5
Research works printed but not linked: 4
- 9. Sceats E. In vitro tissue models: Working in the third dimension. Innov Pharm Technol. 2010;(35): 28– 32.
- 12. Perkel JM. Animal-Free Toxicology. Science (80-). 2007;Available from: http://www.sciencemag.org/site/products/lst_20120302.xhtml.
- 38. Schulz M and Lewald B and Kohlpoth Martin and Rusche Brigitte and Lorenz, Katrin HJ and Unruh Eckehardt and Hansen Peter-D and Miltenburger H. No Title Fischzellinien in der toxikologischen Bewertung von Abwasserproben. ALTEX. 1995; 12(4): 95. 11178434
- 44. Mothersill Carmel and Austin B. In vitro methods in aquatic Ecotoxicology; 2003.
Cited by
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 880
Measurement of oxygen tension within mesenchymal stem cell spheroids
Murphy, K. C., Hung, B. P., Browne-Bourne, S., Zhou, D., Yeung, J., Genetos, D. C., & Leach, J. K. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2016.0851 · Cited by 163
Patient-Derived Organoids for Precision Cancer Immunotherapy
Grönholm, M., Feodoroff, M., Antignani, G., Martins, B., Hamdan, F., & Cerullo, V. (2021) · Cancer Research · doi:10.1158/0008-5472.can-20-4026 · Cited by 146
“This can be seen with organoids or spheroidsmeasuringmore than 100–200mm in size, while organoids with a diameter more than 500 mm develop necrosis (28, 29).”
BackgroundLinking hypoxia, DNA damage and proliferation in multicellular tumor spheroids
Riffle, S., Pandey, R. N., Albert, M., & Hegde, R. S. (2017) · BMC Cancer · doi:10.1186/s12885-017-3319-0 · Cited by 142
“Direct measurements of oxygen levels within spheroids have shown that as spheroid size increases there is a gradient of oxygen tension from the surface to the center [23].”
Millard, M., Yakavets, I., Zorin, V., Kulmukhamedova, A., Marchal, S., & Bezdetnaya, L. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s146927 · Cited by 141
Metadata
- Authors
- Langan, L. M., Dodd, N. J. F., Owen, S. F., Purcell, W. M., Jackson, S. K., & Jha, A. N.
- Affiliations
- University of Plymouth (GB)
- AstraZeneca (United Kingdom) (GB)
- Corresponding author
- Jha, Awadhesh N.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-02-22
- Volume
- 11
- Issue
- 2
- Pages
- e0149492
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4970858
- OpenAlex
- W2287250553
- Cited by
- 104
- References
- 55
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 13 · 2021: 12 · 2020: 15 · 2019: 6 · 2018: 8 · 2017: 9 · 2016: 2
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Update notices
- correction (2016-08-02)
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PEARL (University of Plymouth) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- AstraZeneca
- Biotechnology and Biological Sciences Research Council (BB/L01016X/1)
- Interreg
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Redox biology and oxidative stress
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Cancer and biochemical research
- Keywords
- oxygen gradients, spheroids, EPR oximetry, lithium phthalocyanine, 3D cell culture, organoids, cell seeding density, spheroid size, hypoxia, oxygen diffusion, RTG-2 cells, noninvasive oxygen measurement
- MeSH terms
- Animals, Cell Line, Electron Spin Resonance Spectroscopy, Oximetry, Oxygen, Oncorhynchus mykiss, Spheroids, Cellular
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.