CoChat

Direct Measurements of Oxygen Gradients in Spheroid Culture System Using Electron Parametric Resonance Oximetry

Open access

The DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index; 15 of the 36 sources its claims cite were checked for support.

Abstract

Advanced in vitro culture from tissues of different origin includes three-dimensional (3D) organoid micro structures that may mimic conditions in vivo. One example of simple 3D culture is spheroids; ball shaped structures typically used as liver and tumour models. Oxygen is critically important in physiological processes, but is difficult to quantify in 3D culture: and the question arises, how small does a spheroid have to be to have minimal micro-environment formation? This question is of particular importance in the growing field of 3D based models for toxicological assessment. Here, we describe a simple non-invasive approach modified for the quantitative measurement and subsequent evaluation of oxygen gradients in spheroids developed from a non-malignant fish cell line (i.e. RTG-2 cells) using Electron Paramagnetic Resonance (EPR) oximetry. Sonication of the paramagnetic probe Lithium phthalocyanine (LiPc) allows for incorporation of probe particulates into spheroid during its formation. Spectra signal strength after incorporation of probe into spheroid indicated that a volume of 20 μl of probe (stock solution: 0.10 mg/mL) is sufficient to provide a strong spectra across a range of spheroid sizes. The addition of non-toxic probes (that do not produce or consume oxygen) report on oxygen diffusion throughout the spheroid as a function of size. We provide evidence supporting the use of this model over a range of initial cell seeding densities and spheroid sizes with the production of oxygen distribution as a function of these parameters. In our spheroid model, lower cell seeding densities (∼2,500 cells/spheroid) and absolute size (118±32 μm) allow control of factors such as pre-existing stresses (e.g. ∼ 2% normoxic/hypoxic interface) for more accurate measurement of treatment response. The applied methodology provides an elegant, widely applicable approach to directly characterize spheroid (and other organoid) cultures in biomedical and toxicological research.

Overview

CoChat Summary

TL;DR

This paper demonstrates non-invasive Electron Paramagnetic Resonance (EPR) oximetry using sonicated lithium phthalocyanine (LiPc) to measure oxygen gradients in RTG-2 fish-cell spheroids. It finds that smaller spheroids and lower seeding densities minimize hypoxic/necrotic micro-environments, supporting their use for toxicological 3D models.

Key findings

  • Spheroids formed around LiPc probe particulates; 20 µL of 0.10 mg/mL probe gave strong spectra, and 5 h sonication produced particulates of 11.20 ± 1.02 μm.
  • Oxygen gradients depended on seeding density, size, and time. For 2,500 cells/spheroid at day 7, ΔO₂ was 88%, radius 67 ± 32 μm, viable rim 59 μm, hypoxic zone 8 μm; at day 14, ΔO₂ was 45%, viable rim 30 μm, hypoxic zone 37 μm. For 80,000 cells/spheroid at day 7, ΔO₂ was 22%, radius 350 ± 117 μm, viable rim 77 μm, hypoxic zone 273 μm.
  • The paper recommends working with spheroids below 100–150 μm diameter to limit hypoxia/necrosis; it states that <2% hypoxic/necrotic area allows for presence of senescent cells, and that lower seeding densities (~2,500 cells/spheroid) and absolute size (118 ± 32 μm) allow control of pre-existing stresses.
  • Oxygen consumption rate for a ~120 μm spheroid on day 7 followed −2.21T + 623.77 (R² = 0.91) over 160 min, with a linear range in the first 50 min corresponding to 178–101 μM oxygen; spheroids could not consume oxygen linearly below 100 μM.

Methods

  • RTG-2 rainbow trout gonad cells were seeded at 2,500–80,000 cells/spheroid in pHEMA-coated 96-well U-bottom plates with 20 µL LiPc probe, then maintained under orbital shaking; spheroids formed by day 7.
  • EPR oximetry was performed at 9.4 GHz and 292 K using PTFE tubing; oxygen was quantified from peak-to-peak linewidth relative to fully oxygenated probe/media, with calibration curves.
  • Oxygen consumption rate was measured in sealed glass capillaries with ~5 µL media per spheroid (n = 5), recording spectra every 3 min for 160 min; statistical analysis used Friedman non-parametric test (n = 3, p < 0.05).

Limitations

  • The paper states that OCR kinetics could not be recorded accurately for the first 7–10 min due to inherent linewidth variation, and that part of the oxygen-sensitive LiPc may convert to an oxygen-insensitive form; it also notes the need to calibrate each LiPc batch due to probe purity differences.
  • The paper states assumptions that the spheroid is spherical for even oxygen uptake and that oxygen is calculated as a percentage of all probe particulates irrespective of location, despite heterogeneous distribution due to particulate size.
  • Evident from the text: the study uses a single non-malignant fish cell line (RTG-2), reports n = 3 for main comparisons, and notes difficulty comparing directly with partial-pressure measurements from other 3D oximetry studies because of different cell lines, temperatures, and parameters.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0149492

Cites

54 of 55 references verified1 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Image 1
From the PDF
Image 2
From the PDF
Image 3
From the PDF
Image 4
From the PDF
Fig 2 Oxygen consumption rate using EPR for a spheroid of * 120 μ monday7. A decrease in oxygen concentration relative to time is explained by the formula -2.21T+623.77 (R 2 = 0.91), where μ mole of oxygen is represented by μ MandTis in minutes (160 min) and where the linear range occurs within the first 50 minutes. This linear range corresponds to an oxygen concentration range of 178-101 μ M. It appears that spheroids are unable to consume oxygen in a linear manner below 100 μ M, perhaps due to formation of oxygen diffusion gradients. The OCR rate is a result of the average of two separate experimental runs.
Fig 2 Oxygen consumption rate using EPR for a spheroid of * 120 μ monday7. A decrease in oxygen concentration relative to time is explained by the formula -2.21T+623.77 (R 2 = 0.91), where μ mole of oxygen is represented by μ MandTis in minutes (160 min) and where the linear range occurs within the first 50 minutes. This linear range corresponds to an oxygen concentration range of 178-101 μ M. It appears that spheroids are unable to consume oxygen in a linear manner below 100 μ M, perhaps due to formation of oxygen diffusion gradients. The OCR rate is a result of the average of two separate experimental runs.From the PDF

Verification

Claims the paper makes

12 Valid · 0 Not valid · 10 Not checked · 33 Own results and interpretations

21 more claims · 1 with their cited sources checked

Create a free account to see all 55 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 13
  • It may state two separate claims as one. 19
  • The quote only partly states this claim. 2

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Show all 55 references

Research works printed but not linked: 4

  1. 9. Sceats E. In vitro tissue models: Working in the third dimension. Innov Pharm Technol. 2010;(35): 28– 32.
  2. 12. Perkel JM. Animal-Free Toxicology. Science (80-). 2007;Available from: http://www.sciencemag.org/site/products/lst_20120302.xhtml.
  3. 38. Schulz M and Lewald B and Kohlpoth Martin and Rusche Brigitte and Lorenz, Katrin HJ and Unruh Eckehardt and Hansen Peter-D and Miltenburger H. No Title Fischzellinien in der toxikologischen Bewertung von Abwasserproben. ALTEX. 1995; 12(4): 95. 11178434
  4. 44. Mothersill Carmel and Austin B. In vitro methods in aquatic Ecotoxicology; 2003.

Cited by

Metadata

Authors
Langan, L. M., Dodd, N. J. F., Owen, S. F., Purcell, W. M., Jackson, S. K., & Jha, A. N.
Affiliations
  • University of Plymouth (GB)
  • AstraZeneca (United Kingdom) (GB)
Corresponding author
Jha, Awadhesh N.
Venue
PLOS ONE
Published
2016-02-22
Volume
11
Issue
2
Pages
e0149492
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2287250553
Cited by
104
References
55
Citations by year
2026: 8 · 2025: 9 · 2024: 9 · 2023: 13 · 2022: 13 · 2021: 12 · 2020: 15 · 2019: 6 · 2018: 8 · 2017: 9 · 2016: 2
FWCI
3.39
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PEARL (University of Plymouth) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Funders
  • AstraZeneca
  • Biotechnology and Biological Sciences Research Council (BB/L01016X/1)
  • Interreg
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Redox biology and oxidative stress
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Cancer and biochemical research
Keywords
oxygen gradients, spheroids, EPR oximetry, lithium phthalocyanine, 3D cell culture, organoids, cell seeding density, spheroid size, hypoxia, oxygen diffusion, RTG-2 cells, noninvasive oxygen measurement
MeSH terms
Animals, Cell Line, Electron Spin Resonance Spectroscopy, Oximetry, Oxygen, Oncorhynchus mykiss, Spheroids, Cellular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-07, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-07 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.