Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Physical activity has not been objectively measured in prospective cohorts with sufficiently large numbers to reliably detect associations with multiple health outcomes. Technological advances now make this possible. We describe the methods used to collect and analyse accelerometer measured physical activity in over 100,000 participants of the UK Biobank study, and report variation by age, sex, day, time of day, and season. METHODS: Participants were approached by email to wear a wrist-worn accelerometer for seven days that was posted to them. Physical activity information was extracted from 100Hz raw triaxial acceleration data after calibration, removal of gravity and sensor noise, and identification of wear / non-wear episodes. We report age- and sex-specific wear-time compliance and accelerometer measured physical activity, overall and by hour-of-day, week-weekend day and season. RESULTS: 103,712 datasets were received (44.8% response), with a median wear-time of 6.9 days (IQR:6.5-7.0). 96,600 participants (93.3%) provided valid data for physical activity analyses. Vector magnitude, a proxy for overall physical activity, was 7.5% (2.35mg) lower per decade of age (Cohen's d = 0.9). Women had a higher vector magnitude than men, apart from those aged 45-54yrs. There were major differences in vector magnitude by time of day (d = 0.66). Vector magnitude differences between week and weekend days (d = 0.12 for men, d = 0.09 for women) and between seasons (d = 0.27 for men, d = 0.15 for women) were small. CONCLUSIONS: It is feasible to collect and analyse objective physical activity data in large studies. The summary measure of overall physical activity is lower in older participants and age-related differences in activity are most prominent in the afternoon and evening. This work lays the foundation for studies of physical activity and its health consequences. Our summary variables are part of the UK Biobank dataset and can be used by researchers as exposures, confounding factors or outcome variables in future analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This protocol was, for example, utilized in the UK Biobank study, which recorded accelerometer data from approx.90𝑘 participants, resulting in around 20TB of sensor data [46,198].”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Large-scale data collection efforts by the wearables community, e.g., the GLOBEM dataset [206] and the UK Biobank project [46,198], demonstrated the relative ease of collecting wearable movement in the wild, albeit without annotations.”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To ensure data quality, the study implemented stringent criteria in accordance with the UK Biobank accelerometer expert working group's guidelines.25”
From Accelerometer-measured physical activity, sedentary behavior, and incidence of macrovascular and microvascular events in individuals with type 2 diabetes mellitus and prediabetes (2025) · cites this paper as [25]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [24]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 3×
“Cohort studies which include hundreds of thousands of participants followed up over time are required in order to describe the relationship between physical activity and health outcomes that have a number of potential lifestyle, environmental, and genomic causes [12].”
BackgroundInfluentialSelf-citation‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“We have not generalised the overall descriptive findings to the UK population since the UK Biobank was established as an aetiological study rather than one aimed at population surveillance [5,7].”
BackgroundMethodResultFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Colley, R. C., Garriguet, D., Janssen, I., Craig, C. L., Clarke, J., & Tremblay, M. S. (2011) · PubMed · Cited by 1,096
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citation
Research works printed but not linked: 1
- Ladha C, Ladha K, Jackson D, Olivier P. Shaker Table Validation Of Openmovement Ax3 Accelerometer. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement. Amherst, MA, USA; 2013. pp. 69–70. Available: http://www.umass.edu/sphhs/sites/default/files/ICAMPAM Poster Session Abstracts 4-24.pdf
Cited by
Items 901–1,000 of 1,009
Burton, C. D., Dawes, H., Goodwill, S. R., Thelwell, M., & Dalton, C. (2022) · medRxiv · doi:10.1101/2022.05.31.22275746 · Cited by 2
“00 for adults aged 45-64 was between 40 and 50 milligravitational units [39].”
BackgroundComparing Self-Supervised Learning Techniques for Wearable Human Activity RecognitionPreprint
Ek, S., Presotto, R., Civitarese, G., Portet, F., Lalanda, P., & Bettini, C. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4529608 · Cited by 2
Device-measured moderate-to-vigorous physical activity and prognosis of inflammatory bowel diseasePreprint
He, Z., Sun, Y., Huang, H., Liu, Y., Dan, L., Ruan, X., Fu, T., Li, Z., Wang, X., Chen, J., et al. (2024) · medRxiv · doi:10.1101/2024.10.30.24316417 · Cited by 2
“22 According to prior research, 1-week accelerometer measurements have moderate to high correlations (intraclass correlation coefficients = 0.54-0.82) with repeated assessments over 6 months to 4 years.”
MethodInfluentialOishi, N., Birch, P., Lago, P., & Roggen, D. (2026) · Knowledge-Based Systems · doi:10.1016/j.knosys.2026.116367 · Cited by 1
UniMTS: Unified Pre-training for Motion Time Series
Zhang, X., Teng, D., Chowdhury, R. R., Li, S., Hong, D., Gupta, R. K., & Shang, J. (2024) · arXiv · Cited by 9
“We use graph encoder to model the simulated motion time series, capturing correlations among joints to generalize across different device locations (Section 3.3.1).”
InfluentialAmagasa, S., Kojin, H., Kamada, M., Fukuoka, Y., & Inoue, S. (2021) · PubMed · doi:10.11236/jph.20-143 · Cited by 9
Wei, W., Liu, H., Cheng, B., Qin, X., He, D., Zhang, N., Zhao, Y., Cai, Q., Shi, S., Chu, X., et al. (2023) · Journal of Public Health · doi:10.1007/s10389-023-01886-5 · Cited by 2
“Weekly physical activity levels were measured by the Axivity AX3 wrist-worn triaxial accelerometer, where participants were instructed to wear the monitor on their right hip during all waking hours for seven consecutive days (Doherty et al. 2017).”
UP150 Project: A Longitudinal Analysis of Active Lifestyles in the Complex Working System
Signorini, G., Scurati, R., Bosio, A., D’Angelo, C., Benedini, S., Tringali, C., Magaldi, E., Rigon, M., & Invernizzi, P. L. (2024) · Sports · doi:10.3390/sports12080219 · Cited by 1
“The present study utilized Axivity AX3 triaxial accelerometers (Axivity Ltd., Newcastle upon Tyne, UK, 2013) to objectively measure physical activity and sedentary behavior [27].”
MethodShim, J., Fleisch, E., & Barata, F. (2024) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc53108.2024.10781878 · Cited by 2
“We followed the data pre-processing guidance developed by the UKB accelerometer data processing expert group, which included device calibration, resampling to 100 Hz, and removal of noise and gravity [8].”
Fan, T., Xie, Q., Chen, J., Zeng, M., Chen, S., Yang, H., Ruan, G., Yang, Q., Zhang, Y., Li, Y., et al. (2026) · Rheumatology · doi:10.1093/rheumatology/keag179 · Cited by 4
Physical activity and risk of epilepsy: A 2‐sample Mendelian randomization study
Yang, C., Wang, M., Chen, X., Yao, J., Ma, Y., & Lian, X. (2025) · Epileptic Disorders · doi:10.1002/epd2.70024 · Cited by 1
Qin, P., Ho, F. K. W., Celis-Morales, C. A., Trost, S. G., & Pell, J. P. (2025) · Heart · doi:10.1136/heartjnl-2024-325004 · Cited by 1
Xu, C., Zhang, Q., Xu, S., Xiao, Y., Zhao, L., Li, T.-J., Guo, W.-J., Zhong, Y., & Chen, H.-T. (2025) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2025-002547 · Cited by 1
“In this study, TPA, MVPA and LPA were all stratified into three groups: TPA was based on tertiles (T1, T2 and T3), while MVPA (<150, 150–350 and >350 min per week) and LPA (<1800, 1800–2400 and >2400 min per week) were according to cut-off values of time accumulated weekly.”
Kittner, P., Buergel, T., Lin, C. M. G. J., Willich, S. N., Keil, T., Müller‐Riemenschneider, F., & Krist, L. (2025) · BMC Public Health · doi:10.1186/s12889-025-22922-x · Cited by 1
“While recognizing the importance of physical activity in maintaining health, it’s crucial to acknowledge the limitations of using self-report questionnaires as the primary method for data collection [17].”
Apnea detection using wrist actigraphy in patients with heterogeneous sleep disorders
Xing, X., Ai, S., Zhang, J., Huang, R., Liu, Y., Quan, D., Ma, J., Wu, G., Xu, J., Zhang, Y., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-01430-3 · Cited by 2
Metabolic Status and Atrioventricular Block Risk: The Role of Physical Activity
Chung, H.-G., Yang, P., Jang, E., Joung, D., Kim, D., Yu, H. T., Kim, T., Uhm, J., Sung, J., Pak, H., et al. (2025) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm37291 · Cited by 1
“Detailed information on the protocol and analysis methods for the wrist-worn accelerometer study at the UK Biobank can be found in a previous study [19].”
DML-FitAR: A Deep Metric Learning Approach for IMU-Based Fitness Activity Recognition
Li, T., Li, D., Chen, Y., Li, Z., Ma, Y., Liu, D., Feng, X., Wu, J. Y., & Guo, C. (2025) · International Conference on Multimedia Retrieval · doi:10.1145/3731715.3733311 · Cited by 1
Vetsch, T., Dueblin, S. W.-S., Eser, P., Beilstein, C. M., Wuethrich, P. Y., Wilhelm, M., & Engel, D. A. (2025) · Perioperative Medicine · doi:10.1186/s13741-025-00554-4 · Cited by 1
“An analysis using data from the UK Biobank study ( n = 96,600) reported overall ENMO values of 23.9 m g for women and 22.9 m g for men aged 75–79 years (Doherty et al. 2017).”
InfluentialPérez, B. D., Tsiarleston, G., Castellote‐Caballero, Y., Villegas-Fuentes, A., Gil-Gutiérrez, Y. M., Fernández-Álvarez, J. E., Montes, S., Delgado‐Fernández, M., Ruiz, A. M. M., Molina‐García, P., et al. (2025) · Healthcare · doi:10.3390/healthcare13162065 · Cited by 2
“It is suggested that wrist placement can help reduce selection bias and present minimal discomfort during sleep [70].”
Cai, Y., Ma, T., Sirard, J. R., Pang, M. Y. C., & Xie, Y. J. (2025) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70124 · Cited by 1
Physical activity, air pollution, and incident long-term conditions: a prospective cohort study
Huang, M., Olsen, J., Trost, S. G., Celis-Morales, C. A., Pell, J. P., & Ho, F. K. W. (2025) · BMC Medicine · doi:10.1186/s12916-025-04338-x · Cited by 1
“The dominant wrist of each individual was used over a period of 7 days at 100 Hz, as has been described elsewhere [20].”
Jiang, Y., Su, Z., Liu, S., Di, H., Wu, Q., Hu, W., Qin, T., Zhou, S., Yin, J., Chen, Y., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112420 · Cited by 1
Lawlis, N., Cherbuin, N., Ambikairajah, A., Speer, H., D'Cunha, N. M., Rattray, B., & Northey, J. M. (2025) · Journal of Alzheimer s Disease · doi:10.1177/13872877251374261 · Cited by 2
Knodel, N. B., McLean, S. G., DiCesare, C. A., & Lu, E. (2025) · Military Medicine · doi:10.1093/milmed/usaf267 · Cited by 2
Shi, Q., Jang, H., Collings, P. J., Wang, M., Chen, Z., Luo, S., Yeung, S. L. A., Wan, E. Y. F., Griffin, S. J., Sharp, S. J., et al. (2025) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2025.04.033 · Cited by 1
Self-citationXu, S., Xiao, Y., Xu, C., Zeng, X., Zhao, L., Li, T., Jiang, D., Na, R., & Chen, H. (2025) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2025-002702 · Cited by 1
“Information about cancer was obtained from the cancer register.”
Towards Practical, Best Practice Video Annotation to Support Human Activity Recognition
Tran, H., Potter, V., Mazzucchelli, U., John, D., & Intille, S. S. (2025) · Communications in computer and information science · doi:10.1007/978-3-032-09117-8_6 · Cited by 2
Moebus, M., & Holz, C. (2025) · BMC Public Health · doi:10.1186/s12889-025-24794-7 · Cited by 3
“For 5,191 participants, activity profiles were not computed due to low compliance [39].”
InfluentialLuo, Y., Jiang, Y., Tan, S., Yang, H., Xie, Y., Cui, X., Ju, W., Lyu, H., & Zhang, L. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000004055 · Cited by 3
Meng, D., He, S., Wei, M., Lv, Z., Yang, G., & Wang, Z. (2025) · Physiology & Behavior · doi:10.1016/j.physbeh.2025.115190 · Cited by 1
Eckmann, H. R., Razieh, C., Danilevicz, I. M., Vidil, S., CHASTIN, S. F. M., Sherar, L. B., Hansen, B. H., Dempsey, P. C., Sabia, S., & Rowlands, A. V. (2025) · Scientific Reports · doi:10.1038/s41598-025-30237-5 · Cited by 2
“Between 2013 and 2016 accelerometry was collected in a subpopulation of 106,053 participants continuously for seven days, employing the Axivity AX3 device (Axivity Ltd, Newcastle, UK), sampling at 100 Hz, ± 8 g , worn on the dominant wrist 13 .”
InfluentialKingsnorth, A. P., Thomas, J. J. C., Rowlands, A. V., Edwardson, C. L., Yates, T., & Choudhary, P. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0056 · Cited by 2
Kim, M. S., Kim, J., Jang, E., Kim, D., Yang, P., & Joung, B. (2025) · Korean Circulation Journal · doi:10.4070/kcj.2025.0242 · Cited by 1
“Data were processed using established methods, following the validated machine-learning algorithms developed by Doherty et al., 17) which have demonstrated high accuracy (88”
Wang, Q., Liu, Y., & Zhu, B. (2025) · Arthritis Research & Therapy · doi:10.1186/s13075-025-03716-3 · Cited by 1
“Critically, it also includes wrist-worn accelerometer data collected over 7 days in a large subset of participants, providing vast, objective physical activity data [17].”
Maylor, B. D., Small, S. R., Plekhanova, T., Brocklebank, L. A., van Duijvenboden, S., Sharman, R. L., Hill, E. A., Karpe, F., Kyle, S. D., & Doherty, A. (2025) · JMIR Research Protocols · doi:10.2196/78779 · Cited by 1
“…the raw accelerometer data from the research-grade wearables through existing analytic software, such as Biobank AccelerometerAnalysis (University of Oxford) [8] and Stepcount (University of Oxford) [35], to assess device recording duration and nonwear detection based on accelerometer thresholds.”
Self-citationZhang, Q. J., Yao, Y., Wei, Y., Sun, Y., Zhu, S., Yi, L., & Shan, Y. (2026) · Journal of Physical Activity and Health · doi:10.1123/jpah.2025-0457 · Cited by 1
Rasmussen, C. L., Hendry, D., Beynon, A. M., Stearne, S., Zabatiero, J. G., Davey, P. C., Rohl, A. L., Straker, L. M., & Campbell, A. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2025-0029 · Cited by 2
Tkaczyk, M., Ksinan, A. J., & Šmahel, D. (2026) · Journal of Medical Internet Research · doi:10.2196/78972 · Cited by 5
“Future research should integrate digital trace data [69] and wrist-worn accelerometers data [70] for more accurate measurements.”
A Deep Learning Approach for Parkinsonian Tremor Assessment Using Wearables
Chatzis, T., Grammalidis, N., & Dimitropoulos, K. (2025) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom60686.2025.11342654 · Cited by 1
“Subse-quently, we pass each window w j through a 1D Resnet-V2 encoder f resnet ( · ) with 18 layers, which has been pre-trained by self-supervised learning [16] on the UK-Biobank dataset [17], producing embeddings , where D is the dimensionality of the embeddings of the Resnet encoder.”
Yun, J., Brocklebank, L. A., Harper, C., & Doherty, A. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2026.103769 · Cited by 4
“15 Of those invited, 106,053 participants agreed to wear the device, and 103,712 provided useable raw acceleration data.”
Self-citationSleep and activity patterns in autism
Weissenkampen, J. D., Ghorai, A., Carneiro, T. N. R., Fasolino, M., Gehringer, B. N., Rajan, M., Dow, H. C., Kunatharaju, S., Roenneberg, T., Sebro, R., et al. (2026) · Autism · doi:10.1177/13623613251413538 · Cited by 1
“To assess if autism status modulates the observed relationships, we used the 11 core sleep traits from the three algorithms (GGIR, CS, and Accelerometer) as the outcome variables in linear mixed effects regressions (Supplementary Table VII).”
InfluentialMu, K., Qiao, Y., Lin, R., Yu, Y., Zhao, M., Magnussen, C. G., & Xi, B. (2026) · BMC Medicine · doi:10.1186/s12916-026-04701-6 · Cited by 1
“…not capture all seasonal or long-term behavioral variation, nor individual year-to-year changes in activity habits, this approach represents the standard protocol in accelerometer-based epidemiological studies and has been validated in the UK Biobank study involving over 100,000 participants [20].”
InfluentialA digital mirror of frailty? What daily-life mobility measures add
Hausdorff, J. M., Mirelman, A., & Becker, C. (2026) · Age and Ageing · doi:10.1093/ageing/afag043 · Cited by 1
Le, F., Dumuid, D., D'Elia, O., Haussmann, A., Stamatakis, E., Doherty, A., Liao, Y., & Wiley, J. F. (2026) · Journal of Epidemiology & Community Health · doi:10.1136/jech-2025-225231 · Cited by 2
Self-citationProteomic Signatures Related to Physical Activity Are Associated with Risks of Future Disease
Huang, S., Long, G., Li, G. X., Dai, S., Li, G., HE, Z., Chen, Y., LU, Q., Huang, H., ZHANG, A., et al. (2026) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003909 · Cited by 1
Li, R., Lei, F., Liu, B., Lin, L., Huang, X., Zhang, X., Liu, W., Sun, T., Cao, Y., Wu, Q., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.043217 · Cited by 1
Hyde, E. T., Hayes, H. A., Matthews, C. E., Shreves, A. H., Ylarregui, K., Brennan, S., & Keadle, S. K. (2026) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003989 · Cited by 2
Wu, H., Li, X., Hu, J., Li, P., Li, X., Chen, J., Dong, H., Ou, Y., & Koutrakis, P. (2026) · BMC Nephrology · doi:10.1186/s12882-026-04941-x · Cited by 1
“The details of the data collection and processing of the accelerometers have been reported previously [13].”
Cai, Y., Ma, T., Sirard, J. R., Xie, Y. J., Yang, Q., Lee, C.-D., Wang, X., Liang, X., Li, Y., Lei, J., et al. (2026) · Communications Medicine · doi:10.1038/s43856-026-01421-z · Cited by 2
“…leastonehourlybinonanyofthe7days(acriterionshowntoyieldanintra-class coef fi cient of approximately 0.90 relative to a complete 7-day wear protocol) 26 ; third, we excluded outliers whose average ENMO was more than 9 standard deviations from the sample mean 27 (Supplementary Fig.”
InfluentialAndersen, L. L., Calatayud, J., Núñez-Cortés, R., Polo‐López, A., Suso‐Martí, L., López-Bueno, L., & López‐Bueno, R. (2026) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2026.112181 · Cited by 2
zheng, F., Yuan, Y., Luo, J., Li, S., Xiong, S., Fu, B., Zhou, L., & Zeng, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-47677-2 · Cited by 2
Sharing digital health data responsibly: Balancing open science with participant privacy
Nebeker, C., Samiei, S. A., & Kumar, S. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001377 · Cited by 3
“Large initiatives such as the UK Bio-bank, the National Health and Nutrition Examination Survey (NHANES), the Women’s Health Initiative, and the Baltimore Longitudinal Study of Aging provide researchers worldwide with access to granular physical activity and other health data [2–5].”
Xu, J., Chen, Z., Niu, F., Chen, Y., Sun, X., Wei, W., Tian, Z., & Sun, C. (2026) · Journal of Nutrition · doi:10.1016/j.tjnut.2026.101558 · Cited by 1
Machine learning approaches in predicting circadian rhythm sleep-wake disorders: A review
Sengupta, T., Gaur, A., & Varatharajan, S. (2026) · Chronobiology International · doi:10.1080/07420528.2026.2667404 · Cited by 1
“Later, Doherty et al. (2017) provided a large-scale UK Biobank accelerometer dataset used in subsequent ML-based circadian phenotype modelling (Doherty et al. 2017).”
Zhao, H., Xiao, Q., Wang, H., Zheng, Y., Liu, Z., Jiang, Y., Suo, C., Chen, X., & Xu, K. (2026) · Journal of Pineal Research · doi:10.1111/jpi.70145 · Cited by 1
“Participants were requested to wear the accelerometer on their dominant wrist for 1 week, capturing data at 100 Hz within ± 8 g dynamic range [16].”
Lapointe, Y., Kapur, A., Sharma, A., Panter, J., Fuller, D., & Mamiya, H. (2026) · Preventive Medicine · doi:10.1016/j.ypmed.2026.108603 · Cited by 1
Cognitive Trajectories and Subsequent Accelerometer-Measured Movement Behavior in Older Adults
Bloomberg, M., Brocklebank, L. A., Cavaillès, C., Doherty, A., Sabia, S., & Steptoe, A. (2026) · JAMA Network Open · doi:10.1001/jamanetworkopen.2026.13399 · Cited by 2
Self-citationYang, S., Xiao, X., Yang, Y., Cai, Y., Zou, Y., Tang, Y., Ma, H., & Lai, Z. (2026) · Alzheimer s Research & Therapy · doi:10.1186/s13195-026-02088-3 · Cited by 1
“In our primary analyses, we treated relative amplitude (RA) and the timing metrics (L5/M10 and their start hours) as UK Biobank–derived circadian rest–activity rhythm (CRAR) phenotypes to maximize comparability with prior UK Biobank work [4– 6].”
InfluentialRødevand, L. N., Rahman, Z., Jahołkowski, P., Parker, N., Valdimarsdóttir, U. A., Smeland, O. B., Tesfaye, M., Parekh, P., Frei, O., Djurovic, S., et al. (2026) · EBioMedicine · doi:10.1016/j.ebiom.2026.106304 · Cited by 1
“…of 30,132 individuals identified as White based on self-report (mean age (SD) = 59.37 (16.24) years; 66.99% female) after applying similar inclusion criteria as described by Doherty et al. 39,43 in the UKB GWAS (at least 3 days of data in each 1-h period of the 24-h cycle during a 7-day period).”
InfluentialMusbahi, O., Sousi, S., Al-Saadawi, A., Glynou, S. P., Bottle, A., Jones, G. G., & Cobb, J. P. (2026) · Bone and Joint Research · doi:10.1302/2046-3758.156.bjr-2025-0684.r1 · Cited by 1
Chen, H., Wei, J., Cedernaes, J., Benedict, C., Tsanas, A., Cao, Z., & Tan, X. W. (2026) · Advanced Science · doi:10.1002/advs.76217 · Cited by 1
Kumar, N., & Krishnamurthy, S. (2026) · Journal of Internal Medicine · doi:10.1111/joim.70133 · Cited by 2
Gaibor, C. L. T., Andreu, S. B., Lord, S. R., & Chan, L. L. Y. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261464535 · Cited by 1
Xie, H., Xue, F., & Wang, X. (2026) · Lifetime Data Analysis · doi:10.1007/s10985-026-09721-1 · Cited by 1
“These data are linked to longitu - dinal diagnostic outcomes, including incident PD, allowing for the first time a rigor - ous investigation of how subtle, real-world variations in behavior may precede PD diagnosis (Doherty et al. 2017).”
Influentialde Moura, B. P., Sasaki, J. E., Griep, R. H., Feter, N., Schmidt, M. I., & da Fonseca, M. D. J. M. (2026) · MethodsX · doi:10.1016/j.mex.2026.104092 · Cited by 1
“These approaches, however, may require greater familiarity with accelerometry methods, programming skills in R or related environments, and computational resources for large-scale datasets [5,31,32].”
InfluentialFerreira, F. P., & Daly, A. (2022) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms55023.2022.00046 · Cited by 2
Vigorous intermittent lifestyle physical activity improves mortality risk
(2022) · Nature Medicine · doi:10.1038/s41591-022-02101-w · Cited by 1
Salway, R., Augustin, N. H., & Armstrong, M. E. G. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20146401 · Cited by 1
“Accelerometer data were processed to produce data on acceleration (measured in milligravities) at five-second epochs, with non-wear time imputed based on similar timeof-day data; full details of data processing are available elsewhere [3].”
BackgroundMethodInfluentialMontoye, A. H. K., Clevenger, K. A., Boudreaux, B. D., & Schmidt, M. D. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0034 · Cited by 1
Evenson, K. R., Wen, F., Di, C., Kebede, M., LaMonte, M. J., Lee, I.-M. M., Tinker, L. F., LaCroix, A. Z., & Howard, A. G. (2024) · Women s Health · doi:10.1177/17455057241257361 · Cited by 1
Siebra, C., & Wac, K. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106858 · Cited by 2
Kutyifa, V., Christof, M., Mullane, S., Harrell, C., Singh, J. P., Chinitz, L. A., Varma, N., Piccini, J. P., Turakhia, M. P., & Rosero, S. Z. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.07.020 · Cited by 1
Maylor, B. D., Rowlands, A. V., Daley, A., Sanders, J. P., Yates, T., & Edwardson, C. L. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0056 · Cited by 2
Causal association of physical activity with lymphoma risk: a Mendelian randomization analysis
Zhao, J., Wen, X., Zheng, M., Su, L., & Guo, X. (2024) · European Journal of Public Health · doi:10.1093/eurpub/ckae172 · Cited by 2
British Association of Sport and Exercise Sciences abstracts
NEEDHAM, R., ROBSON, J., SAYWER, D., BODDEN, J., CARTER, R., & WALKER, P. (2024) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2419272 · Cited by 1
Kuroda, H., Yeung, S. L. A., Fujii, R., Iwagami, M., & Goto, A. (2025) · Journal of Diabetes Investigation · doi:10.1111/jdi.70039 · Cited by 4
“The details of a sub-study of accelerometers have been published elsewhere 24 .”
Coulter, A., Lee, R., & Gaynanova, I. (2025) · The Journal of Open Source Software · doi:10.21105/joss.07925 · Cited by 1
“The fastfrechet package addresses these limitations by providing a fast, scalable, and user-friendly implementation of both Fréchet regression and variable selection for 2-Wasserstein space, based on the work of Coulter et al. (2024).”
Narayanan, A., Duncan, S., Smith, C., Le, F., Mackay, L. M., McPhee, J., Chaix, B., & Stewart, T. I. (2025) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-025-01769-w · Cited by 4
“Data were processed using UK Biobank machine learning algorithms [23] to derive daily estimates (in minutes) of four key time-use behaviours: Sedentary, LPA, MVPA, and Sleep.”
Meng, D., Wei, M., He, S., Lv, Z., Zhang, H., Yang, G., & Wang, Z. (2025) · Journal of Addictive Diseases · doi:10.1080/10550887.2025.2516290 · Cited by 1
“22 The summary statistics data for habitual physical activity behavior by Klimentidis et al. 21 is available at https://www.ebi.ac.uk/gwas/publications/36071172 (access date: May 20, 2024).”
Hesse, K., Khanji, M. Y., Chahal, C. A. A., Petersen, S. E., & Aung, N. (2025) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyaf092 · Cited by 3
Kinuthia, S. K., Stratton, G., Wachira, L.-J. M., Okoth, V., Owino, G., Ochola, S., Kiplamai, F., Onywera, V. O., & Swindell, N. J. (2025) · PLoS ONE · doi:10.1371/journal.pone.0329173 · Cited by 1
Pan, Y., Zhang, W., Dai, Y., Liu, Y., Gao, D., Zhang, Y., Ma, J., Zhu, M., Diao, X., Yang, X., et al. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70166 · Cited by 1
“Thirdly, the accelerometer data collection spanned only 7 days, 20 Fanfan Zheng and Wuxiang Xie had full access to all the data in the study and take responsibility for the integrity of the data and the accuracy of the data analysis.”
The interplay between genomic copy number variants, sleep, and cognition in the general population
Poulain, C., Tesfaye, R., Douard, E. A., Jean‐Louis, M., Saci, Z., Labbe, A., Glahn, D. C., Almasy, L. A., Elsabbagh, M., Huguet, G., et al. (2025) · Translational Psychiatry · doi:10.1038/s41398-025-03579-x · Cited by 1
“Individuals were excluded based on UKBB quality checks previously described [31, 33], we further excluded individuals wearing the device for <5 days and those with extreme short (<3 h) or long (>12 h) mean sleep duration [30, 31].”
Estimating Sedentary Breathing Rate from Chest-Worn Accelerometry From Free-Living Data
Telfer, B. A., Williamson, J. R., Weed, L., Bursey, M., Frazee, R., Galer, M., Moore, C., Buller, M. J., & Friedl, K. E. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175669 · Cited by 1
“[19] A. Doherty, D. Jackson et al., “Large scale population assessment of physical activity using wrist worn accelerometers: The UK Biobank study,” PLOS One, Feb. 2017.”
BackgroundPolygenic Score For Physical Activity Provides Odds For Multiple Common Diseases
Sillanpää, E., Palviainen, T., Gen, F., Ripatti, S., Kujala, U. M., & Kaprio, J. A. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000761316.78359.5b · Cited by 2
Kim, Y. J., Swift, D. L., Houmard, J. A., Wu, Q., Sears, S. F., & Paul, A. M. (2022) · Physiotherapy Practice and Research · doi:10.3233/ppr-210586 · Cited by 1
“The non-dominant wrist as a measurement placement was shown to increase the wear compliance [17, 18].”
Novel Methods of Measuring and Visualising Youths’ Physical Activity
Crossley, S. G. M. (2019) · Cronfa (Swansea University) · doi:10.23889/suthesis.50756 · Cited by 1
Millard, L. A. C., Tilling, K. M., Gaunt, T. R., Carslake, D., & Lawlor, D. A. (2020) · medRxiv · doi:10.1101/2020.05.22.20108795 · Cited by 1
“0 milli-gravities [m-grav]) lasting for at least 60 137 minutes (the sensitivity of the accelerometer makes it possible to detect very small movements indicating it 138 is being worn) (17).”
BackgroundInfluentialPredicting age from 100,000 one week-long 100Hz wrist accelerometer records of physical activityPreprint
Goallec, A. L., Collin, S., Jabri, M., Diai, S., Vincent, T., & Patel, C. J. (2021) · medRxiv · doi:10.1101/2021.06.21.21259265 · Cited by 1
Physical Activity in Adolescents with respect to Movement Quality and Quantity
Weedon, B. D. (2020) · Radar (Oxford Brookes University) · doi:10.24384/381r-t238 · Cited by 3
Primary Data Collection for Pharmacoepidemiology
Velentgas, P. (2021) · Wiley eBooks · doi:10.1002/9781119701101.ch11 · Cited by 1
Beach, C., & Casson, A. J. (2021) · doi:10.36227/techrxiv.14662713.v1 · Cited by 1
Raw triaxial wrist accelerometer-measured physical activity in mid-age Australian adultsPreprint
Mielke, G. I., Burton, N. W., & Brown, W. J. (2022) · Research Square · doi:10.21203/rs.3.rs-1464314/v1 · Cited by 1
Faculty Opinions recommendation of The UK Biobank resource with deep phenotyping and genomic data.
Gao, F. (2018) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.734198301.793551571 · Cited by 1
CARE: a novel wearable-derived feature linking circadian amplitude to human cognitive functionsPreprint
Cui, S., Lin, Q., Gui, Y., Zhang, Y., Lu, H., Zhao, H., Wang, X., Li, X., & Jiang, F. (2023) · medRxiv · doi:10.1101/2023.04.06.23288232 · Cited by 1
Chen, Y., Geng, T., Xu, X., Zhang, Z., Huang, L., Dong, H., Yu, H., Gao, X., & Sun, L. (2024) · medRxiv · doi:10.1101/2024.06.28.24309628 · Cited by 1
Acquah, A., Creagh, A. P., Hamy, V., Shreves, A. H., Zisou, C., Harper, C., van Duijvenboden, S., Antoniades, C. A., Bennett, D., Clifton, D. A., et al. (2024) · medRxiv · doi:10.1101/2024.08.13.24311539 · Cited by 1
“A subgroup of participants consented to wear an Axivity AX3 wrist-worn accelerometer for up to 7 days between 2013-2015 15 .”
BackgroundSelf-citationSteps for Stopping Kidney Stones: Physical Activity Triumphant Over Genetics
Katkam, N., & Beddhu, S. (2024) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2024.07.001 · Cited by 3
Resistance Exercise Therapy for Long COVID: a Randomized, Controlled TrialPreprint
Berry, C., McKinley, G., Bayes, H. K., Anderson, D., Lang, C. C., Gill, A., Morrow, A., Sykes, R., Taggart, D., Kamdar, A. L., et al. (2025) · Research Square · doi:10.21203/rs.3.rs-6269439/v1 · Cited by 1
Koemel, N. A., Biswas, R. K., Ahmadi, M. N., Teixeira-Pinto, A. M., Hamer, M., Rezende, L. F. M., Mitchell, J. J., Leech, R. M., Sawan, M. J., Allman-Farinelli, M. A., et al. (2025) · medRxiv · doi:10.1101/2025.04.24.25326344 · Cited by 1
Metadata
- Authors
- Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., Preece, S. J., Gillions, R., Sheard, S., Peakman, T., Brage, S., & Wareham, N. J.
- Affiliations
- University of Oxford (GB)
- Newcastle University (GB)
- University of Salford (GB)
- University of Cambridge (GB)
- UK Biobank (GB)
- Corresponding author
- Doherty, Aiden
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-01
- Volume
- 12
- Issue
- 2
- Pages
- e0169649
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5287488
- OpenAlex
- W2584016859
- Cited by
- 1,250
- References
- 22
- Citations by year
- 2026: 180 · 2025: 210 · 2024: 179 · 2023: 142 · 2022: 110 · 2021: 148 · 2020: 108 · 2019: 87 · 2018: 66 · 2017: 20
- FWCI
- 56.84
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Apollo (cc-by)
- Funders
- Wellcome Trust
- Medical Research Council (MC_UU_12015/1, MC_UU_12015/3)
- British Heart Foundation (GB) (RE/13/1/30181)
- Li Ka Shing Foundation (HK)
- Research Councils UK (GB) (EP/G066019/1)
- Engineering and Physical Sciences Research Council (EP/L016176/1)
- National Institute for Health Research (SRF-2011-04-017)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- physical activity, wrist-worn accelerometers, objective physical activity measurement, UK Biobank, age differences in physical activity, sex differences in physical activity, diurnal variation, seasonal variation, vector magnitude, triaxial acceleration
- MeSH terms
- Aged, Female, United Kingdom, Humans, Male, Middle Aged, Seasons, Time Factors, Wrist Joint, Exercise, Biological Specimen Banks, Accelerometry, Public Health Surveillance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.