Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Physical activity has not been objectively measured in prospective cohorts with sufficiently large numbers to reliably detect associations with multiple health outcomes. Technological advances now make this possible. We describe the methods used to collect and analyse accelerometer measured physical activity in over 100,000 participants of the UK Biobank study, and report variation by age, sex, day, time of day, and season. METHODS: Participants were approached by email to wear a wrist-worn accelerometer for seven days that was posted to them. Physical activity information was extracted from 100Hz raw triaxial acceleration data after calibration, removal of gravity and sensor noise, and identification of wear / non-wear episodes. We report age- and sex-specific wear-time compliance and accelerometer measured physical activity, overall and by hour-of-day, week-weekend day and season. RESULTS: 103,712 datasets were received (44.8% response), with a median wear-time of 6.9 days (IQR:6.5-7.0). 96,600 participants (93.3%) provided valid data for physical activity analyses. Vector magnitude, a proxy for overall physical activity, was 7.5% (2.35mg) lower per decade of age (Cohen's d = 0.9). Women had a higher vector magnitude than men, apart from those aged 45-54yrs. There were major differences in vector magnitude by time of day (d = 0.66). Vector magnitude differences between week and weekend days (d = 0.12 for men, d = 0.09 for women) and between seasons (d = 0.27 for men, d = 0.15 for women) were small. CONCLUSIONS: It is feasible to collect and analyse objective physical activity data in large studies. The summary measure of overall physical activity is lower in older participants and age-related differences in activity are most prominent in the afternoon and evening. This work lays the foundation for studies of physical activity and its health consequences. Our summary variables are part of the UK Biobank dataset and can be used by researchers as exposures, confounding factors or outcome variables in future analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This protocol was, for example, utilized in the UK Biobank study, which recorded accelerometer data from approx.90𝑘 participants, resulting in around 20TB of sensor data [46,198].”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Large-scale data collection efforts by the wearables community, e.g., the GLOBEM dataset [206] and the UK Biobank project [46,198], demonstrated the relative ease of collecting wearable movement in the wild, albeit without annotations.”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To ensure data quality, the study implemented stringent criteria in accordance with the UK Biobank accelerometer expert working group's guidelines.25”
From Accelerometer-measured physical activity, sedentary behavior, and incidence of macrovascular and microvascular events in individuals with type 2 diabetes mellitus and prediabetes (2025) · cites this paper as [25]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [24]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 3×
“Cohort studies which include hundreds of thousands of participants followed up over time are required in order to describe the relationship between physical activity and health outcomes that have a number of potential lifestyle, environmental, and genomic causes [12].”
BackgroundInfluentialSelf-citation‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“We have not generalised the overall descriptive findings to the UK population since the UK Biobank was established as an aetiological study rather than one aimed at population surveillance [5,7].”
BackgroundMethodResultFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Colley, R. C., Garriguet, D., Janssen, I., Craig, C. L., Clarke, J., & Tremblay, M. S. (2011) · PubMed · Cited by 1,096
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citation
Research works printed but not linked: 1
- Ladha C, Ladha K, Jackson D, Olivier P. Shaker Table Validation Of Openmovement Ax3 Accelerometer. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement. Amherst, MA, USA; 2013. pp. 69–70. Available: http://www.umass.edu/sphhs/sites/default/files/ICAMPAM Poster Session Abstracts 4-24.pdf
Cited by
Items 801–900 of 1,009
Wan, L., Zuo, H., & Li, D. (2023) · Scandinavian Journal of Gastroenterology · doi:10.1080/00365521.2023.2287416 · Cited by 4
“This latter group was obligated to make use of an Actigraph Axivity AX3 accelerometer for a minimum duration of 72 h within a single week [27].”
MethodLiu, H., Zhang, Y.-J., & Zhang, W. (2024) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2024.1418455 · Cited by 4
Martinelli, A., Leone, S., Zamparini, M., Carnevale, M., Caterson, I. D., Fuller, N. R., Calza, S., & de Girolamo, G. (2024) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2024.09.007 · Cited by 3
Hagger, M. S., & Hamilton, K. (2024) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000893 · Cited by 5
“…gaps in determinant and intervention research, and identify emergent research questions Observational studies have indicated that belief-based psychological determinants norms, self-efficacy , and risk perceptions are associated with familial hypercholesterolemia therapeutic behaviors [20 & ].”
Clevenger, K. A., McNarry, M. A., Mackintosh, K. A., Pfeiffer, K. A., Nelson, B. A., Bock, J. M., Imboden, M. T., Kaminsky, L. A., & Montoye, A. H. K. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0013 · Cited by 3
Jiang, Z., Wang, B., Zhao, Y., Weng, J., Sun, K., Zhao, Z., Luo, R., Zhang, Z., Zhou, X., Zhang, Z., et al. (2025) · The journal of nutrition health & aging · doi:10.1016/j.jnha.2025.100586 · Cited by 4
“8 g (unit of gravity) [18].”
Chaturvedi, R. R., Angrisani, M., Troxel, W., Jain, M., Gutsche, T., Ortega, E., Boch, A., Liang, C., Sima, S., Mezlini, A. M., et al. (2025) · PNAS Nexus · doi:10.1093/pnasnexus/pgaf295 · Cited by 3
“In contrast, studies that recruit from clinical encounters (e.g. UK Biobank, AoU ) are more likely to underrepresent people experiencing healthcare access barriers, who also tend to be non-White, under-resourced, and/ or of poorer health (17 – 20, 70, 71).”
Lin, Z., Chen, J., Cai, Y., Wang, Z., Xu, J., Shi, Y., Li, J., Xu, P., Shen, J., Chen, G., et al. (2025) · BMC Public Health · doi:10.1186/s12889-025-24662-4 · Cited by 2
“Further information regarding the collection, validation, and processing of the data can be found in other sources [8, 34].”
InfluentialRahimi-Eichi, H., Baker, J. T., Fjell, A. M., & Buckner, R. L. (2025) · SLEEP Advances · doi:10.1093/sleepadvances/zpaf079 · Cited by 6
“A subset of 111635 participants, ages 44– 82 years, was randomly selected during 2014–2015 to wear wrist-worn accelerometers for the passive measurement of physical activity levels, after providing informed consent [16].”
Rose, A. V., Boreskie, K. F., Hay, J. L., Thompson, L., Arora, R. C., & Duhamel, T. A. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-044227 · Cited by 13
Alrahma, A. M., Habib, M. A., Oulhaj, A., Loney, T., Boillat, T., Shah, S. M. A., Ahmed, L. A., & Nauman, J. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-051070 · Cited by 4
Wearable Accelerometers in Cancer Patients
Dadhania, S., & Williams, M. (2021) · Intelligent systems reference library · doi:10.1007/978-3-030-83620-7_5 · Cited by 3
Shelley, J., Boddy, L. M., Knowles, Z. R., Stewart, C. E., Frost, F. J., Nazareth, D. S., Walshaw, M. J., & Dawson, E. A. (2022) · Journal of Sports Sciences · doi:10.1080/02640414.2022.2115224 · Cited by 3
Zhou, W., Veliz, P. T., Smith, E., Chen, W., Reddy, R. M., & Larson, J. L. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20021001 · Cited by 5
“103,720 participants returned data between 2013 and 2015 [28].”
BackgroundMethodInfluentialMa, T., Sirard, J. R., & Jennings, L. (2023) · Journal of Physical Activity and Health · doi:10.1123/jpah.2022-0505 · Cited by 3
Engineering Large Wearable Sensor Data towards Digital Measures
Zhang, H., Ruan, G., Giesting, R., Miller, L., Patel, N., Ji, J., Yang, Y. L., & Yang, J. (2023) · IEEE International Conference on Big Data Analytics (ICBDA) · doi:10.1109/icbda57405.2023.10104923 · Cited by 5
“In Table I, we summarize the endpoints obtained from GGIR and Biobank.”
BackgroundMethodInfluentialAccelerometer‐derived sleep measures in idiopathic dystonia: A UK Biobank cohort study
Bailey, G. A., Wadon, M. E., Komarzynski, S., Matthews, C., Davies, E. H., & Peall, K. J. (2023) · Brain and Behavior · doi:10.1002/brb3.2933 · Cited by 2
“The UK Biobank (UKBB) is a large population-based study integrating detailed clinical data, including raw accelerometer data, self-reported symptom questionnaires, including pain and psychiatric symptoms, primary care records, and hospital admissions (Doherty et al., 2017).”
BackgroundMethodInfluentialA Unified Data Architecture for Assessing Motor Symptoms in Parkinson’s Disease
Gundler, C., Zhu, Q., Trübe, L., Dadkhah, A., Gutowski, T., Rosch, M., Langebrake, C., Nürnberg, S., Baehr, M., & Ückert, F. (2023) · Studies in health technology and informatics · doi:10.3233/shti230689 · Cited by 4
Overview of methods and available tools used in complex brain disorders
Ilias, L., Doukas, G. S., Kontoulis, M., Alexakis, K., Michalitsi-Psarrou, A., Ntanos, C., & Askounis, D. (2023) · Open Research Europe · doi:10.12688/openreseurope.16244.1 · Cited by 3
“It can be installed via Python and also needs Java to be installed 83–86 .”
BackgroundLin, W., Karahanoğlu, F. I., Psaltos, D., Adamowicz, L., Santamaria, M., Cai, X., Demanuele, C., & Di, J. (2023) · Sensors · doi:10.3390/s23208542 · Cited by 4
Phaswana, M., & Gradidge, P. J.-L. (2023) · BMC Research Notes · doi:10.1186/s13104-023-06642-2 · Cited by 4
“The AX3 accelerometer (Newcastle-upon-Tyne, United Kingdom) was used to evaluate sleep, sedentary behaviour, light physical activity (LPA), and moderate-to-vigorous physical activity (MVPA) [17].”
MethodWei, M., Meng, D., He, S., Guo, H., Yang, G., & Wang, Z. (2024) · Alcohol · doi:10.1016/j.alcohol.2024.05.002 · Cited by 3
Haresamudram, H., Tang, C. I., Suh, S., Lukowicz, P., & Plötz, T. (2024) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3675094.3677562 · Cited by 8
Self-citationLeBlanc, E. S., Smith, N. X., Hwang, D., Young, D. R., Oshiro, C. E. S., Mayhew, M., Massimino, S., Catlin, C., & Clarke, G. N. (2024) · Contemporary Clinical Trials · doi:10.1016/j.cct.2024.107796 · Cited by 3
Elhakeem, A., Gregson, C. L., Tobias, J. H., & Lawlor, D. A. (2020) · Annals of Human Biology · doi:10.1080/03014460.2019.1707284 · Cited by 4
“In 2013-2015, eligible UK Biobank participants were invited to wear an Axivity AX3 wrist-worn accelerometer (Open Lab, Newcastle University) on the dominant hand for seven consecutive days (Doherty et al. 2017).”
MethodPelclová, J., Štefelová, N., Olds, T., Dumuid, D., Hron, K., CHASTIN, S. F. M., & Pedišić, Ž. (2021) · BMC Geriatrics · doi:10.1186/s12877-021-02148-3 · Cited by 5
Experience with an accelerometer to estimate physical activity level in the population
Zabina, E. Y., Zinovyeva, V. A., Popovich, M. V., Starovoitov, M. A., Glazunov, I. S., Danilova, E. S., Manshina, А. V., & Усова, Е. В. (2017) · Russian Journal of Preventive Medicine · doi:10.17116/profmed201720554-58 · Cited by 3
Using Wearable Devices to Assess Physical Behavior in Epidemiologic Research
Freedson, P. S. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0029 · Cited by 3
Wou, C., Šilarova, B., Griffin, S. J., & Usher‐Smith, J. A. (2018) · Public Health · doi:10.1016/j.puhe.2018.09.006 · Cited by 38
Standing up against office sitting: A study protocol
Gradidge, P. J.-L., Phaswana, M., Wijndaele, K., Crowther, N. J., & Draper, C. E. (2020) · South African Journal of Physiotherapy · doi:10.4102/sajp.v76i1.1415 · Cited by 4
“The AX3 has been used in large-scale surveillance studies such as the UK Biobank study (Doherty et al. 2017).”
MethodBeach, C., & Casson, A. J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9631066 · Cited by 3
“pre-processing steps in [3], based upon those by the UK Biobank expert group [7].”
MethodNavigome: Navigating the Human PhenomePreprint
Gaspar, H. A., Hübel, C., Coleman, J. R. I., Hanscombe, K. B., & Breen, G. D. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/449207 · Cited by 3
Primary Data Collection for Pharmacoepidemiology
Dreyer, N. A., Macedo, A. F., & Velentgas, P. (2019) · Pharmacoepidemiology · doi:10.1002/9781119413431.ch16 · Cited by 3
Yuan, H., Plekhanova, T., Walmsley, R., Reynolds, A. C., Maddison, K. J., Bucan, M., Gehrman, P., Rowlands, A., Ray, D. W., Bennett, D., et al. (2023) · doi:10.1101/2023.07.07.23292251 · Cited by 3
“Humans spend approximately 79 one third of their lives asleep, yet sleep is hard to assess in free-living environ80 ments [1].”
BackgroundInfluentialSelf-citationDeterminants of Consent in the SHARE Accelerometer Study
Franzese, F., Schrank, F., & Bergmann, M. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0046 · Cited by 2
Predictors of Physical Activity One Year After Moderate to Severe Traumatic Brain Injury
Pradhan, S. D., Esterov, D., Driver, S. J., Whyte, J., Bell, K. R., Barber, J. K., Temkin, N., & Bombardier, C. H. (2024) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0000000000000966 · Cited by 3
“Other estimates of PA from adults, based on non-bout measurements using wrist accelerometers, are similar 53 or greater, 54 suggesting that norms based in wrist accelerometry may be higher, and data from wrist accelerometers should be compared to these norms only due to the large variability…”
Neuvonen, J., Aittokoski, T., Rantalainen, T., Lipponen, J. A., Palmberg, L., Brage, S., Gonzales, T. I., Portegijs, E., Rantanen, T., & Karavirta, L. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0042 · Cited by 2
Self-citationFrom Vision to Motion: Translating Large-Scale Knowledge for Data-Scarce IMU Applications
Yoon, H., Cha, H., Nguyen, H. C., Gong, T., & Lee, S.-J. (2025) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2025.3556998 · Cited by 10
“Nevertheless, unlike images and text that benefit from large-scale, diverse public datasets, existing IMU datasets [13], [14], [15] primarily focus on Human Activity Recognition (HAR) and lack diversity.”
Chen, Y., Wang, Y., Song, X., Xu, T., & Wang, F. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1570026 · Cited by 2
A scoping review of adult NCD-relevant phenotypes measured in today’s large child cohort studies
McBain, K., Dumuid, D., Shipton, A. J., Clifford, S. A., Olds, T., & Wake, M. A. (2025) · Pediatric Research · doi:10.1038/s41390-025-04056-3 · Cited by 3
“This will ensure that all major NCD precursors are adequately represented over time for greatest future bene fi t.”
Lazaro‐Pacheco, D., Ebisch, I., Cooper-White, J. J., & Holsgrove, T. P. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c01773 · Cited by 2
Fulda, E. S., Portas, L., Harper, C., Preiss, D., Bennett, D., & Doherty, A. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003738 · Cited by 2
“A random selection of participants with a valid email address ( N = 236,519) was invited to wear a wrist-worn accelerometer for 7 d (18).”
Self-citationWang, X., Gao, Y., Lou, L., Yang, W., Xu, W., Zhao, Y., & Ren, J. (2025) · BMC Pulmonary Medicine · doi:10.1186/s12890-025-03779-7 · Cited by 3
Albalak, G., van Bodegom, D., Thangarajah, P., Giltay, E. J., van Heemst, D., & Noordam, R. (2025) · BMJ Public Health · doi:10.1136/bmjph-2024-002245 · Cited by 2
Chronic inflammation mediates the relationship between physical activity and telomere length
Nanda, A., Aslan, D. H., Sayre, M. K., Bharadwaj, P. K., Ally, M., Song, H., Arora, A., Maltagliati, S., Lai, M. H. C., Wilcox, R. R., et al. (2025) · GeroScience · doi:10.1007/s11357-025-01818-z · Cited by 4
“All accelerometer data was collected from 2013 to 2015 [30].”
Peng, Q., Ma, T., He, L., Cheng, X., & Xie, W. (2025) · Experimental Gerontology · doi:10.1016/j.exger.2025.112858 · Cited by 3
Preventive circadian medicine: improving health with sleep checkups
Minami, Y., Kishi, A., & Ueda, H. R. (2025) · npj Biological Timing and Sleep · doi:10.1038/s44323-025-00047-z · Cited by 3
“…dozing, napping, insomnia, sleepiness, snoring, and chronotype, as well as an activity monitor data set (category 1008 and its subcategories) capturing physical activity using wearables (AX3, Axivity) over seven days for approximately 100,000 participants, which can be used to quantify sleep 51 .”
“Weekend warrior” physical activity pattern and risk of incident cancer
López‐Bueno, R., Andersen, L. L., López, L., Suso‐Martí, L., Núñez‐Cortés, R., López‐Gil, J. F., & Calatayud, J. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2536198 · Cited by 2
“We retrieved data from 103 666 participants from the accelerometer subsample who wore an Axivity AX3 wrist-based triaxial accelerometer for 1 week to assess MVPA [9].”
InfluentialTajimi, T., Chan, L. L. Y., Okubo, Y., & Lord, S. R. (2025) · GeroScience · doi:10.1007/s11357-025-01878-1 · Cited by 3
“The study population comprised participants from the UK Biobank accelerometry sub-study [23].”
Keusch, F., Struminskaya, B., Mulder, J., & Jongerius, S. (2025) · Journal of Medical Internet Research · doi:10.2196/69799 · Cited by 5
Effectiveness of instruments for assessing physical activity in adolescents: a systematic review
Kuanysh, Z., Vlassova, A., Seidakhmetova, A., Auyezkhankyzy, D., Baituganova, A., & Saduyeva, F. (2025) · Physical Activity and Nutrition · doi:10.20463/pan.2025.0024 · Cited by 3
Alrahma, A. M., Habib, M. A., Masuadi, E., Loney, T., Boillat, T., Shah, S. M. A., Ahmed, L. A., & Nauman, J. (2025) · BMC Public Health · doi:10.1186/s12889-025-24815-5 · Cited by 3
“These measurements were conducted for both groups at baseline and week 12, along with the tri-axial accelerometer (AX3 Axivity, UK), which was worn for seven consecutive days both at baseline and at week 12, similar to previous studies [28, 29].”
Zhou, P., Geng, X., Zhang, C., Li, T., Li, F., Cao, Y., Mao, D., Liu, Y., Wang, N., Li, K., et al. (2025) · BMC Public Health · doi:10.1186/s12889-025-24359-8 · Cited by 4
“A subsample of 103,695 individuals responded to an e-mail invitation to wear a wrist-worn accelerometer between 2013 and 2015 [22].”
He, Z., Sun, Y., Huang, H., Wellens, J., Liu, Y., Dan, L., Ruan, X., Fu, T., Li, Z., Wang, X., et al. (2025) · International Journal of Surgery · doi:10.1097/js9.0000000000003255 · Cited by 4
“Triaxial acceleration data are collected at 100 Hz with a dynamic range of ±8 g and extracted after processing [18] .”
InfluentialPhysical Activity and Cardiovascular Outcomes in Phenotype-Negative Cardiomyopathy Variant Carriers
Ajufo, E. C., Kany, S., Jurgens, S. J., Churchill, T. W., Guseh, J. S., Aragam, K. G., Nauffal, V., Pirruccello, J. P., Choi, S. H., Lakdawala, N. K., et al. (2025) · JAMA Cardiology · doi:10.1001/jamacardio.2025.4466 · Cited by 3
Frequency-Aware Masked Autoencoders for Human Activity Recognition using Accelerometers
Lorenzen, N. R., Jennum, P. J., Mignot, E., & Brink-Kjaer, A. (2025) · 2025 47th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11252605 · Cited by 2
“The unlabeled high-resolution wrist-worn accelerometer dataset from the UK Biobank [22] was used for self-supervised pretraining in this work.”
Sánchez-Lastra, M. A., Cruz, B. D. P., Tarp, J., Dalene, K. E., Nilsen, T. S., Ding, D., & Ekelund, U. (2025) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2025.101116 · Cited by 2
“26 As a result, a total of 6077 participants classified in the different disease groups had valid data.”
Genetic susceptibility, walking activity and the risk of incident gout
Wu, Z., Hu, Y., Wang, Y., Zhang, Y., He, H., Zeng, C., Lei, G., & Wei, J. (2025) · Rheumatology · doi:10.1093/rheumatology/keaf690 · Cited by 2
Liu, J., Cheng, H., & Feng, G. (2026) · Discover Oncology · doi:10.1007/s12672-025-04178-4 · Cited by 3
“Missing sample size data were supplemented using the “UK Biobank” and “FinnGen” databases [24], while missing EAF data were estimated using the “1000 Genomes Project” to ensure data completeness and accuracy [25, 26].”
Kobeissi, E., Dempsey, P. C., Alshallal, A. D., Rennie, K. L., Brage, S., Wijndaele, K., & Strain, T. (2026) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0035 · Cited by 2
Self-citationShim, J., Bishehsari, F., Mahdavinia, M., Zeitzer, J. M., Fleisch, E., & Barata, F. (2026) · npj Aging · doi:10.1038/s41514-026-00349-x · Cited by 5
“However,previousstudieshavedemonstrated thatUKBiobankgeneralpractitionerrecordsyieldreasonablyaccurate laboratoryvalues,supportingtheirutilityinlarge-scaleepidemiological research 32 .”
Genetic architecture of sleep in a genome wide association study of device measured sleep traits
Portas, L., Yuan, H., Cai, L., Smith-Byrne, K., van Duijvenboden, S., Kyle, S. D., Ray, D. W., Howson, J. M. M., & Doherty, A. (2026) · Nature Communications · doi:10.1038/s41467-026-71252-y · Cited by 2
“For the present analyses, we focused on a subset of 103,680 participants who wore a wrist-worn accelerometer for 7 days between 2013 and 2015 31 and restricted the sample to individuals of European ancestry.”
Self-citationChong, K. H., Ahmadi, M. N., Biswas, R. K., François, M. E., Koemel, N. A., Sabag, A., Gibala, M. J., Keating, S. E., Little, J., Thøgersen‐Ntoumani, C., et al. (2026) · Diabetes Care · doi:10.2337/dc25-3018 · Cited by 5
Digital Sleep-Wake Cycle Metrics and Dementia Prediction in Older Adults
Cavaillès, C., Danilevicz, I. M., Vidil, S., Fayossé, A., Chen, M., van Hees, V. T., Kivimäki, M., Dugravot, A., Singh‐Manoux, A., & Sabia, S. (2026) · JAMA Neurology · doi:10.1001/jamaneurol.2026.1232 · Cited by 4
Zhide, L., Du, S., Zhao, S., Wang, X., Yan, Q., Xu, B., Ng, S., & Ning, Z. (2026) · British Journal of Sports Medicine · doi:10.1136/bjsports-2025-111351 · Cited by 3
“28 In this substudy, participants wore a wrist-mounted Axivity AX3 accelerometer at 100 Hz for seven consecutive days.”
Beaupre, L. M., Wainberg, M., Zai, C. C. H., Milic, M. S., Felsky, D., Brown, G. M., Goldstein, B. I., Tripathy, S. J., Kennedy, J. L., & Gonçalves, V. F. (2022) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2022.11.010 · Cited by 2
Yuan, Y., Hu, W., Zhang, X., Borchert, G., Wang, W., Zhu, Z., & He, M. (2022) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000578 · Cited by 2
Schell, R. C., Dow, W. H., Fernald, L. C. H., Bradshaw, P. T., & Rehkopf, D. H. (2024) · PLoS ONE · doi:10.1371/journal.pone.0304653 · Cited by 4
Montoye, A. H. K., LaMunion, S. R., Brønd, J. C., & Clevenger, K. A. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0057 · Cited by 2
“Yet, since 2010, accelerometers have been increasingly worn continuously on the wrist (Belcher et al., 2021; Doherty et al., 2017) or thigh (Stevens et al., 2020), enabling measurement of the full 24-hr period for seven days a week or longer.”
Du, Z., Wang, S., Bulloch, G., Zhang, F., Wang, Y., Lai, C., Zhuo, Z., Huang, Y. S., Shang, X., Fang, Y., et al. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.7.3 · Cited by 3
“15 Exploring accelerometer-measured daily behaviors, specifically in individuals with refractive errors, can offer new perspectives on the occurrence of depressive disorders and facilitate the development of targeted interventions for their rehabilitation.”
BackgroundHan, S., Oh, B., Kim, H. J., Hwang, S. E., & Kim, J. S. (2024) · JMIR Human Factors · doi:10.2196/59659 · Cited by 5
“In recent years, the use of accelerometers to objectively measure PA levels has gained popularity, offering more accurate and reliable data compared to self-reported measures [18-21].”
Backgroundde Girolamo, G., Leone, S., D’Addazio, M., Toffol, E., Martinelli, A., Bellini, S., Calza, S., Carnevale, M., Cattane, N., Cattaneo, A., et al. (2024) · Trials · doi:10.1186/s13063-024-08525-8 · Cited by 2
“Individual Actigraph GT9X files will be processed using the GGIR package [35] to estimate VM [36] using a 60-s epoch and default settings (calibration, no data imputation).”
MethodLiu, P. Z., Raizen, D. M., Skarke, C., Brooks, T. G., & Anafi, R. C. (2024) · SLEEP · doi:10.1093/sleep/zsae243 · Cited by 2
Li, A., Gong, S., Yu, C., Pei, P., Yang, L., Millwood, I. Y., Walters, R. G., Chen, Y., Du, H., Yang, X., et al. (2024) · Diabetes · doi:10.2337/db24-0736 · Cited by 2
Papapanagiotou, V., Sarafis, I., Alagialoglou, L., Gkolemis, V., Diou, C., & Delopoulos, A. N. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3526794 · Cited by 3
“While there are a lot of from dominant-hand worn sensors [35], in our case the smartwatch was usually worn on the wrist of the non-dominant hand.”
Chung, H.-G., Yang, P., Jang, E., Kim, J., Kim, M. H., Kim, D., Yu, H. T., Kim, T., Uhm, J., Sung, J., et al. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.01.005 · Cited by 2
Guo, H., Sun, Y., Gao, W., Liu, Y., Han, T., & Zhang, D. (2025) · BMC Public Health · doi:10.1186/s12889-025-21576-z · Cited by 2
Tian, G., Yao, Z.-Y., Hu, W., Shen, Z., Liu, B.-P., & Jia, C.-X. (2025) · Journal of Affective Disorders · doi:10.1016/j.jad.2025.01.151 · Cited by 3
Bürki, C., Tian, C., Westerman, K. E., & Patel, C. J. (2025) · JMIR mhealth and uhealth · doi:10.2196/54820 · Cited by 3
“Between 2013 and 2015, a total of 103,661 participants consented to wear a wrist accelerometer for 7 consecutive days [19].”
Wendt, A. T., Leite, G. S., Contreira, R. D. L., Mielke, G. I., Horta, B. L., Motta, J. V. D. S., Hartwig, F. P., Wehrmeister, F. C., Menezes, A. M. B., Gonçalves, H., et al. (2025) · Cadernos de Saúde Pública · doi:10.1590/0102-311xen011724 · Cited by 2
Maltagliati, S., Aslan, D. H., Sayre, M. K., Bharadwaj, P. K., Ally, M., Lai, M. H. C., Wilcox, R. R., Klimentidis, Y. C., Alexander, G. E., & Raichlen, D. A. (2025) · The Journals of Gerontology Series B · doi:10.1093/geronb/gbaf071 · Cited by 3
Al‐Ozairi, E., Irshad, M., Alkandari, J., Taghadom, E., Varghese, A. L., Alroudhan, D., Al-Qattan, N., & Gray, S. R. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16584 · Cited by 2
“31 Overall PA (total volume of PA) was quantified using the acceleration throughout the day, calculated as the Euclidean Norm Minus One (ENMO) in milli gravitational units (m g ), thus simply reflecting all movement throughout the day.”
Wang, D., Wei, Y., Xiang, Q., Yang, H., & Shan, Y. (2025) · Journal of Periodontology · doi:10.1002/jper.11388 · Cited by 2
Pinilla, B. H., Hong, S. S., Brodie, M. A. D., Lord, S. R., & Chan, L. L. Y. (2025) · The Journals of Gerontology Series A · doi:10.1093/gerona/glaf184 · Cited by 4
Coulter, A., Aurora, R. N., Punjabi, N. M., & Gaynanova, I. (2025) · The Annals of Applied Statistics · doi:10.1214/25-aoas2038 · Cited by 7
“For example, distributional approaches are also advantageous for data from actigraphy devices (Ghosal et al., 2021; Matabuena and Petersen, 2023), while large-scale repositories, such as UK Biobank (Doherty et al., 2017), contain both actigraphy data and large number of individual’s characteristics.”
Zhang, Q., Fu, L., Zhao, J. H., Chen, K., Tse, G., Lip, G. Y. H., & Liu, T. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf604 · Cited by 3
Reducing annotation burden in physical activity research using vision language models
Schönfeldt, A., Maylor, B. D., Chen, X., Clark, R., & Doherty, A. (2025) · Scientific Reports · doi:10.1038/s41598-025-21350-6 · Cited by 7
“The CAPTURE24-CN study was collected in 2017 from 113 participants in the Sichuan province of China alongside a similar effort to develop and validate approaches to derive wrist-worn accelerometer-based physical activity measurements in over 20 000 participants in the China Kadoorie Biobank(Chen et al., 2023).”
InfluentialSelf-citationLDC '19: international workshop on longitudinal data collection in human subject studies
Manea, V. C., Berrocal, A., Masi, A. D., Møller, N. H., Wac, K., Bayer, H. M., Lehmann, S., & Ashley, E. A. (2019) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3341162.3347758 · Cited by 2
48th European Mathematical Genetics Meeting (EMGM) 2020
Kutalik, Z. (2019) · Human Heredity · doi:10.1159/000507248 · Cited by 1
Davies, A. J., Shi, Y., Bauman, A. E., & Allman-Farinelli, M. A. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18115688 · Cited by 5
“While previous studies predominantly used hip-worn accelerometers, more recent studies used wrist-worn accelerometers due to higher compliance [45,46].”
ResultUnsupervised Classification of Human Activity with Hidden Semi-Markov Models
Cavallo, F. R., Toumazou, C., & Nikolić, K. (2022) · Applied System Innovation · doi:10.3390/asi5040083 · Cited by 2
Xiang, M., Pilling, L. C., Melzer, D. R., Kirk, B., Duque, G., Liu, R., Kuchel, G. A., Wood, A. R., Metcalf, B. S., Diniz, B. S., et al. (2023) · GeroScience · doi:10.1007/s11357-023-00890-7 · Cited by 4
“Participants attending the aPA assessment were asked to wear an Axivity AX3 triaxial accelerometer (https:// axivi ty. com/ produ ct/ ax3) on the wrist of their dominant hand, for 24 h a day for seven consecutive days [24].”
MethodChiu, C., Hou, S., Wang, C., Tang, H.-H., Kuo, P.-C., Liang, S., & Kuo, P.-F. (2024) · BMC Public Health · doi:10.1186/s12889-023-17552-0 · Cited by 3
“For example, comparisons with other studies using actigraphy, such as the National Social Life, Health, and Aging Project (NSHAP) [84] and the UK biobank study [85, 86], to determine objective sleep and physical activity patterns among middle-aged and older adults in different countries.”
ResultCrowe, C., Barton, J. J., O’Flynn, B., & Tedesco, S. A. (2024) · Aging Clinical and Experimental Research · doi:10.1007/s40520-024-02757-z · Cited by 2
“This study was based on a random sample of 14,161 subjects, between the age of 40 and 71, which participated in the UK Biobank Study [ 31].”
MethodPhysical Activity, Cardiorespiratory Fitness, and Obesity
de Lannoy, L., & Ross, R. (2019) · Springer eBooks · doi:10.1007/978-3-030-04816-7_14 · Cited by 1
Oeckel, V. V., Deforche, B. I., Ridgers, N. D., Bere, E. T., & Verloigne, M. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17186708 · Cited by 3
Weisberg, A., Campelo, A. M., Bhaidani, T., & Katz, L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0050 · Cited by 3
“Accelerometry is the most widely used method for objective assessment of PA in population studies (Doherty et al., 2017; Henriksen et al., 2018).”
BackgroundMethodMoellenbeck, B., Horst, F., Gosheger, G., Theil, C., Seeber, L., & Kalisch, T. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10071544 · Cited by 3
“Furthermore, at least one day of the weekend was included, as a higher activity level is generally expected here [30].”
BackgroundChen, X., Guan, Y., Shi, J. Q., Du, X., & Eyre, J. A. (2020) · arXiv (Cornell University) · Cited by 2
Theory-based Habit Modeling for Enhancing Behavior PredictionPreprint
Zhang, C., Vanschoren, J., van Wissen, A., Lakens, D., de Ruyter, B., & IJsselsteijn, W. A. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2101.01637 · Cited by 2
“The Axivity AX3 sensor is a 3-axis accelerometer developed by Newcastle University specifically for scientific research on human movements [38].”
Background
Metadata
- Authors
- Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., Preece, S. J., Gillions, R., Sheard, S., Peakman, T., Brage, S., & Wareham, N. J.
- Affiliations
- University of Oxford (GB)
- Newcastle University (GB)
- University of Salford (GB)
- University of Cambridge (GB)
- UK Biobank (GB)
- Corresponding author
- Doherty, Aiden
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-01
- Volume
- 12
- Issue
- 2
- Pages
- e0169649
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5287488
- OpenAlex
- W2584016859
- Cited by
- 1,250
- References
- 22
- Citations by year
- 2026: 180 · 2025: 210 · 2024: 179 · 2023: 142 · 2022: 110 · 2021: 148 · 2020: 108 · 2019: 87 · 2018: 66 · 2017: 20
- FWCI
- 56.84
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Apollo (cc-by)
- Funders
- Wellcome Trust
- Medical Research Council (MC_UU_12015/1, MC_UU_12015/3)
- British Heart Foundation (GB) (RE/13/1/30181)
- Li Ka Shing Foundation (HK)
- Research Councils UK (GB) (EP/G066019/1)
- Engineering and Physical Sciences Research Council (EP/L016176/1)
- National Institute for Health Research (SRF-2011-04-017)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- physical activity, wrist-worn accelerometers, objective physical activity measurement, UK Biobank, age differences in physical activity, sex differences in physical activity, diurnal variation, seasonal variation, vector magnitude, triaxial acceleration
- MeSH terms
- Aged, Female, United Kingdom, Humans, Male, Middle Aged, Seasons, Time Factors, Wrist Joint, Exercise, Biological Specimen Banks, Accelerometry, Public Health Surveillance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.