Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Physical activity has not been objectively measured in prospective cohorts with sufficiently large numbers to reliably detect associations with multiple health outcomes. Technological advances now make this possible. We describe the methods used to collect and analyse accelerometer measured physical activity in over 100,000 participants of the UK Biobank study, and report variation by age, sex, day, time of day, and season. METHODS: Participants were approached by email to wear a wrist-worn accelerometer for seven days that was posted to them. Physical activity information was extracted from 100Hz raw triaxial acceleration data after calibration, removal of gravity and sensor noise, and identification of wear / non-wear episodes. We report age- and sex-specific wear-time compliance and accelerometer measured physical activity, overall and by hour-of-day, week-weekend day and season. RESULTS: 103,712 datasets were received (44.8% response), with a median wear-time of 6.9 days (IQR:6.5-7.0). 96,600 participants (93.3%) provided valid data for physical activity analyses. Vector magnitude, a proxy for overall physical activity, was 7.5% (2.35mg) lower per decade of age (Cohen's d = 0.9). Women had a higher vector magnitude than men, apart from those aged 45-54yrs. There were major differences in vector magnitude by time of day (d = 0.66). Vector magnitude differences between week and weekend days (d = 0.12 for men, d = 0.09 for women) and between seasons (d = 0.27 for men, d = 0.15 for women) were small. CONCLUSIONS: It is feasible to collect and analyse objective physical activity data in large studies. The summary measure of overall physical activity is lower in older participants and age-related differences in activity are most prominent in the afternoon and evening. This work lays the foundation for studies of physical activity and its health consequences. Our summary variables are part of the UK Biobank dataset and can be used by researchers as exposures, confounding factors or outcome variables in future analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This protocol was, for example, utilized in the UK Biobank study, which recorded accelerometer data from approx.90𝑘 participants, resulting in around 20TB of sensor data [46,198].”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Large-scale data collection efforts by the wearables community, e.g., the GLOBEM dataset [206] and the UK Biobank project [46,198], demonstrated the relative ease of collecting wearable movement in the wild, albeit without annotations.”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To ensure data quality, the study implemented stringent criteria in accordance with the UK Biobank accelerometer expert working group's guidelines.25”
From Accelerometer-measured physical activity, sedentary behavior, and incidence of macrovascular and microvascular events in individuals with type 2 diabetes mellitus and prediabetes (2025) · cites this paper as [25]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [24]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 3×
“Cohort studies which include hundreds of thousands of participants followed up over time are required in order to describe the relationship between physical activity and health outcomes that have a number of potential lifestyle, environmental, and genomic causes [12].”
BackgroundInfluentialSelf-citation‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“We have not generalised the overall descriptive findings to the UK population since the UK Biobank was established as an aetiological study rather than one aimed at population surveillance [5,7].”
BackgroundMethodResultFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Colley, R. C., Garriguet, D., Janssen, I., Craig, C. L., Clarke, J., & Tremblay, M. S. (2011) · PubMed · Cited by 1,096
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citation
Research works printed but not linked: 1
- Ladha C, Ladha K, Jackson D, Olivier P. Shaker Table Validation Of Openmovement Ax3 Accelerometer. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement. Amherst, MA, USA; 2013. pp. 69–70. Available: http://www.umass.edu/sphhs/sites/default/files/ICAMPAM Poster Session Abstracts 4-24.pdf
Cited by
Items 701–800 of 1,009
Echevarría-Polo, M., Marin, P. J., Pueyo, E., Ramos‐Maqueda, J., & Garatachea, N. (2025) · Sensors · doi:10.3390/s25082480 · Cited by 7
“Axivity accelerometers have been widely used in research studies [3–6], with the UK Biobank standing out as one of the most significant and impactful [7].”
Penzel, T., Salanitro, M., & Fietze, I. (2025) · Journal of Sleep Research · doi:10.1111/jsr.70092 · Cited by 4
“Additionally, the UK Biobank has leveraged actigraphy, a tool primarily designed for analysing activity and movement, to include sleep assessments in its research (Doherty et al. 2017).”
Device-captured incidental physical activity, sedentary behaviour and all-cause mortality risk
Koemel, N. A., Ahmadi, M. N., Biswas, R. K., Sabag, A., Cheng, S. W. M., Bauman, A. E., & Stamatakis, E. (2025) · Journal of Epidemiology & Community Health · doi:10.1136/jech-2024-222394 · Cited by 6
Manyara, A. M., Mwaniki, E., Gray, C. M., & Gill, J. M. R. (2021) · Tropical Medicine & International Health · doi:10.1111/tmi.13629 · Cited by 7
“Three days of wear time has been shown to provide physical activity values within 10% of a complete seven-day measure [36].”
BackgroundMachine Learning Based Sleep Phase Monitoring using Pulse Oximeter and Accelerometer
Navarro, M.-A. J. M., Nicdao, J. A. I., & Cruz, J. C. D. (2021) · International Conference on Electrical, Telecommunication and Computer Engineering (ELTICOM) · doi:10.1109/elticom53303.2021.9590128 · Cited by 5
Actividad física y calidad de vida relacionada con la salud en adultos mayores chilenos
MENARES, K. G. H., Carreño, F. V., Norambuena-Mardones, L., & Merellano-Navarro, E. (2022) · Revista Chilena de Rehabilitación y Actividad Física · doi:10.32457/reaf1.1761 · Cited by 6
Bielemann, R. M., Oliveira, R. S., Bertoldi, A. D., Tomasi, E., Demarco, F. F., González, M. C., Wendt, A. T., Brage, S., & Ekelund, U. (2022) · Journal of Aging and Physical Activity · doi:10.1123/japa.2021-0148 · Cited by 7
Self-citationDadhania, S., Pakzad-Shahabi, L., Mistry, S., & Williams, M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285399 · Cited by 7
Calculating the matrix profile from noisy data
Hehir, C., & Smeaton, A. F. (2023) · PLoS ONE · doi:10.1371/journal.pone.0286763 · Cited by 6
“Raw data from a neck-worn AX3 accelerometer sensor [34] on new-born calves was used where the sensor was worn from birth for several weeks by each calf.”
Weedon, B. D., Esser, P., Collett, J., Izadi, H., Joshi, S., Meaney, A., Delextrat, A. A., Kemp, S., & Dawes, H. (2023) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2023.2265442 · Cited by 5
“PA was measured using a wrist-worn accelerometer (Axivity AX3) over 7 days which has shown good accuracy in determining physical activity intensities (Doherty et al., 2017; Hedayatrad et al., 2020).”
MethodIsolated REM sleep behavior disorder is associated with altered 24-h rest-activity measures
Winer, J. R., Lok, R., Ekelmans, A., Bueno, F. F., Poston, K. L., Zeitzer, J. M., & During, E. (2023) · Frontiers in Sleep · doi:10.3389/frsle.2023.1286124 · Cited by 5
Lai, Z., Gan, W., Yang, Y., Chen, L., & Lin, H. (2023) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2023.117396 · Cited by 7
Detection of Medication Taking Using a Wrist-Worn Commercially Available Wearable Device
Laughlin, A. I., Cao, Q., Bryson, R., Haughey, V., Abdul-Salaam, R., Gonzenbach, V., Rudraraju, M., Eydman, I., Tweed, C. M., Fala, G. J., et al. (2023) · JCO Clinical Cancer Informatics · doi:10.1200/cci.22.00107 · Cited by 8
Annear, M. J., Kidokoro, T., & Shimizu, Y. (2024) · Journal of Aging and Physical Activity · doi:10.1123/japa.2023-0129 · Cited by 5
Chang, A. H., Hertel, E., Bruun, M. K., Kristensen, E. S., Petersen, K. K., & Rathleff, M. S. (2025) · European Journal of Pain · doi:10.1002/ejp.70026 · Cited by 6
“The wrist-worn Actigraph Accelerometer has been employed in the UK Biobank study (Barker et al. 2019; Doherty et al. 2017) and the US National Health and Nutrition Examination Survey (NHANES) (National Health Examination and Nutrition Survey 2011; Shim et al. 2023), due to its advantages in…”
A Wearable Internet of Things Based System with Edge Computing for Real-Time Human Activity Tracking
Cooney, N. J., Joshi, K. P., & Minhas, A. S. (2018) · Asia-Pacific World Congress on Computer Science and Engineering (APWC on CSE) · doi:10.1109/apwconcse.2018.00013 · Cited by 5
Panomics: New Databases for Advancing Cardiology
Vakili, D., Radenković, D., Chawla, S., & Bhatt, D. L. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.587768 · Cited by 7
Zhang, J., Merikangas, K. R., Li, H., & Shou, H. (2022) · The Annals of Applied Statistics · doi:10.1214/21-aoas1596 · Cited by 9
Early-life physical performance predicts the aging and death of elite athletes
Newman, S. (2023) · Science Advances · doi:10.1126/sciadv.adf1294 · Cited by 5
Simon, J., Fung, K., Raisi‐Estabragh, Z., Aung, N., Khanji, M. Y., Zsarnóczay, E., Merkely, B. P., Munroe, P. B., Harvey, N. C., Piechnik, S. K., et al. (2023) · European Heart Journal - Imaging Methods and Practice · doi:10.1093/ehjimp/qyad010 · Cited by 7
“20,21 Statistical analysis was performed using R (version 4.0.3) Statistical Software.”
InfluentialPerez-Pozuelo, I., White, T., Westgate, K. L., Wijndaele, K., Wareham, N. J., & Brage, S. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0024 · Cited by 8
Self-citationHiggins, S., Higgins, L. Q., & Vallabhajosula, S. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002562 · Cited by 7
“Moreover, as the assessment of PA via wrist-worn accelerometers has gained popularity because of the potential for better protocol compliance (21,22), it is crucial that we determine the utility of wrist-based PA measures in relation to mechanical loading and bone health.”
BackgroundAutomated detection of sleep-boundary times using wrist-worn accelerometryPreprint
O’Donnell, J., Hollowell, S., Salimi‐Khorshidi, G., Velardo, C., Sexton, C. E., Rahimi, K., Johansen‐Berg, H., Tarassenko, L., & Doherty, A. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/225516 · Cited by 6
Self-citationResponse to: One size does not fit all—application of accelerometer thresholds in chronic disease
Barker, J., Smith-Byrne, K., Doherty, A., Foster, C. E., Rahimi, K., Ramakrishnan, R., Woodward, M., & Dwyer, T. (2019) · International Journal of Epidemiology · doi:10.1093/ije/dyz165 · Cited by 6
Self-citationOdhiambo, C. O., Wright, P. J., Corbett, C., & Valafar, H. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2105.08907 · Cited by 8
“…was originally envisaged for use within the domain of Human Digital Memory to create a personal lifelog or visual recording of the wearer's life, which can be helpful as an aid to human memory, (3) multi-axis inertial sensors worn on wrists[32], [33], and (4) the use of commodity smartwatches [34].”
MethodThe associations between thermal variety and health: Implications for space heating energy use
Kennard, H. R., Huebner, G. M., Shipworth, D., & Oreszczyn, T. (2020) · PLOS ONE · doi:10.1371/journal.pone.0236116 · Cited by 4
“for their work on the AX3 monitor [20].”
BackgroundLu, D., Zhang, W., & Tan, S. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1478533 · Cited by 4
Long-term self-supervised learning for accelerometer-based sleep–wake recognition
Logacjov, A., Bach, K., & Mork, P. J. (2024) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2024.109758 · Cited by 8
Rey, V. F., Rezende, P. M. B., Zhou, B., Suh, S., & Lukowicz, P. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.129288 · Cited by 14
Yu, P., Zhang, Y., Kam, K. W., Ho, M., Au, S. C. L., Zhang, X. J., Ng, M. P. H., Ip, P., Young, A. L., Pang, C. P., et al. (2025) · BMC Medicine · doi:10.1186/s12916-025-04312-7 · Cited by 5
“S2 (Additional file 1) [38].”
Zhou, W., Veliz, P. T., Pu, J., Luo, W., Shang, S., & Larson, J. L. (2025) · BMC Pulmonary Medicine · doi:10.1186/s12890-025-03969-3 · Cited by 8
“1) [14].”
UK Biobank: Transforming drug discovery and precision medicine
Bešević, J., Said, S., Nagy, R., Jamshidi, Y., Whelan, C. D., Carson, L., Rutter, M. K., Lewandowski, A. J., Effingham, M., Collins, R., et al. (2025) · British Journal of Pharmacology · doi:10.1111/bph.70254 · Cited by 4
“Between 2013 and 2016, 100,000 UK Biobank participants wore a wrist-worn accelerometer for 7 days to obtain objective measures of physical activity and sleep (Doherty et al., 2017; UK Biobank, 2016), to allow for more accurate assessment of the impact of physical activity on future disease risk.”
Acquah, A., Creagh, A. P., Hamy, V., Shreves, A. H., Zisou, C., Harper, C., van Duijvenboden, S., Antoniades, C. A., Bennett, D., Clifton, D. A., et al. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-01214-6 · Cited by 6
“A subgroup of participants consented to wear an Axivity AX3 wrist-worn accelerometer for up to 7 days between 2013 and 2015 13 .”
Self-citationHi-OSCAR: Hierarchical Open-set Classifier for Human Activity Recognition
McCarthy, C., Quirijnen, L., van Zandwijk, J. P., Geradts, Z., & Worring, M. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3770681 · Cited by 6
“IMU devices are cheap and non-invasive, making large-scale data collection relatively feasible, and projects such as the UK-Biobank [25] and NHANES [12] have produced huge amounts of sensor data.”
Zhu, R., Chen, C., Kuang, M., Tai, Y., Qin, Y., & Wu, C. (2026) · Hypertension · doi:10.1161/hypertensionaha.125.25444 · Cited by 6
Serena, R. S., Hirschmann, M. T., Matziolis, G., von Eisenhart‐Rothe, R., Rueckert, D., Hinterwimmer, F., & Valle, C. (2026) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1002/ksa.70332 · Cited by 5
“Raw triaxial signals were calibrated, fi ltered and processed to detect non ‐ wear, after which validated physical activity and sleep measures were derived [4].”
InfluentialDigital and AI-Empowered Health Elements: An Integrated Pathway to Advancing Health
Li, P., Zhou, Y., li, Y., Dong, E., & Zhang, L. (2026) · Health Data Science · doi:10.34133/hds.0468 · Cited by 6
“Behavioral elements include physical activity, diet, sleep, substance use, stress-related behaviors, and health literacy, many of which can now be observed through digital devices and continuous monitoring technologies [ 24 , 25 ].”
Vyhlídal, T., Dygrýn, J., Hrubá, J., & Chmelík, F. (2023) · Scientific Reports · doi:10.1038/s41598-023-34689-5 · Cited by 4
Jabbar, K. B. A., Ardle, R. M., Lord, S., Kerse, N. M., Din, S. D., & Teh, R. (2023) · Sensors · doi:10.3390/s23177615 · Cited by 5
“, [21,22]) which in turn has led to issues related to the robustness of these metrics—how reliable, valid and responsive are they? Few studies have examined these questions in-depth (e.”
BackgroundLin, W., Karahanoğlu, F. I., Demanuele, C., Khan, S., Cai, X., Santamaria, M., Di, J., & Adamowicz, L. (2023) · Frontiers in Digital Health · doi:10.3389/fdgth.2023.1321086 · Cited by 5
Wang, H., Dai, Y., Tai, Y., Zhou, Z., Zhou, X., Li, B., & Liang, Y. (2024) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2024.107080 · Cited by 5
Nightbeat: Heart Rate Estimation From a Wrist-Worn Accelerometer During Sleep
Moebus, M., Hauptmann, L., Kopp, N., Demirel, B. U., Braun, B., & Holz, C. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3514293 · Cited by 12
“Participants received the same simple and short instructions as those in the U.K. Biobank motion substudy [1] to ensure a little-controlled experimental setting.”
InfluentialUK Biobank: what can it do, how you can use it and how is it being used?
Free, T. (2024) · BioTechniques · doi:10.1080/07366205.2024.2441639 · Cited by 5
“Weekend Warrior” Physical Activity and Adipose Tissue Deposition
Kany, S., Al‐Alusi, M. A., Rämö, J. T., Pirruccello, J. P., Ajufo, E. C., Churchill, T. W., Lubitz, S. A., Maddah, M., Guseh, J. S., Ellinor, P. T., et al. (2025) · JACC Advances · doi:10.1016/j.jacadv.2025.101603 · Cited by 6
Lü, S., Zhu, Y., Cui, M., Guo, Z., Li, X., & Song, Y. (2025) · Health Science Reports · doi:10.1002/hsr2.70479 · Cited by 8
“Objective accelerometer ‐ measured PA data were collected from 100,000 participants who wore the Axivity AX3 wrist ‐ worn accelerometer for 7 days [27].”
Weitz, M., Syed, S., Hopstock, L. A., Morseth, B., Henriksen, A., & Horsch, A. (2025) · PLoS ONE · doi:10.1371/journal.pone.0321558 · Cited by 6
“The authors have declared that no competing interests exist. eters are used in many population [1–3] and clinical studies [4,5].”
Matthews, C. E., Saint‐Maurice, P. F., Freeman, J. R., Hayes, H. A., Shreves, A. H., Doherty, A., Hyde, E. T., Ylarregui, K., Jones, R. R., & Keadle, S. K. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0051 · Cited by 7
Self-citationShen, C., Du, Z., Lai, C., Su, T., Wu, Q., Chen, Y., Fang, Y., Zhu, Z., Zhang, X., & Yu, H. (2025) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-025-01745-1 · Cited by 4
“Recent methods analyze triaxial acceleration data at subsecond resolutions to more accurately predict energy expenditure, summarized as daily minutes of light, moderate, or vigorous PA [8], [9].”
Osuka, Y., Chan, L. L. Y., Brodie, M. A. D., Okubo, Y., & Lord, S. R. (2025) · Age and Ageing · doi:10.1093/ageing/afaf210 · Cited by 5
Chrismas, B. C. R., Majed, L., Al-Mohannadi, A. S., & Sayegh, S. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.927386 · Cited by 4
Jeran, S., Steinbrecher, A., Haas, V. K., Mähler, A., Boschmann, M., Westerterp, K. R., Brühmann, B. A., Steindorf, K., & Pischon, T. (2022) · Scientific Reports · doi:10.1038/s41598-022-20639-0 · Cited by 5
Bayesian hierarchical modeling and analysis for actigraph data from wearable devices
Loro, P. A. D., Mingione, M., Lipsitt, J. M., Batteate, C., Jerrett, M., & Banerjee, S. (2023) · The Annals of Applied Statistics · doi:10.1214/23-aoas1742 · Cited by 8
“For this reason, it is usually averaged over 5 to 10 second epochs to acquire a more suitable measure of PA intensity [Migueles et al., 2017, Doherty et al., 2017].”
BackgroundMethodInfluentialNonparticipation Bias in Accelerometer-Based Studies and the Use of Propensity Scores
Antoun, C., & Wenz, A. (2024) · Social Science Computer Review · doi:10.1177/08944393241254463 · Cited by 4
“…participants taking off an activity tracker to sleep or bathe (Farina et al., 2019), demographic correlates of wear-time among participants (e.g., Doherty et al., 2017), and a set of statistical procedures that can be used to detect and correct for non-wear through imputation (e.g., Van Hess et…”
Chen, X., Zhou, M., Wang, J., Liu, M., Zhu, C., Wu, C., Dong, M., Liu, Y., Ai, S., Feng, H., et al. (2024) · General Hospital Psychiatry · doi:10.1016/j.genhosppsych.2024.08.005 · Cited by 4
Sánchez-Lastra, M. A., Strain, T., Ding, D., Dalene, K. E., Cruz, B. D. P., Ekelund, U., & Tarp, J. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.101018 · Cited by 7
“16 Time spent in LPA and moderate-to-vigorous physical activity (MVPA) was determined using a validated machine-learning method.”
Tsanas, A. (2025) · IEEE Access · doi:10.1109/access.2025.3539278 · Cited by 4
Huang, Y., Zheng, K., Tan, T. C., Zheng, J., Chen, T., Huang, T., & Wang, K. (2025) · Complementary Therapies in Clinical Practice · doi:10.1016/j.ctcp.2025.101964 · Cited by 10
Clevenger, K. A., McKee, K. L., Elwood, R. E., Pfeiffer, K. A., & Montoye, A. H. K. (2025) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2025.2473904 · Cited by 4
“Notably, while the UK Biobank study used devices on the dominant wrist (Doherty et al., 2017), the National Health and Nutrition Examination Study (NHANES) used the non-dominant wrist (Belcher et al., 2021).”
Yang, T., Pang, D., Huang, J., Xiao, Y., Li, C., Wei, Q., Ou, R., Cheng, Y., Lin, J., Che, N.-N., et al. (2025) · Translational Psychiatry · doi:10.1038/s41398-025-03328-0 · Cited by 4
“Complete sleep factor data [Category 100057 (ox.ac.uk)] were collected via the touchscreen questionnaire during the initial assessment visit when participants were recruited.”
Yu, Y., Tang, Y.-L., Li, X., Hu, Z., Li, J., Wang, J., Jiang, S., Zhang, H., & Liu, J. (2025) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2025.101040 · Cited by 6
“36 Quality control for the raw accelerometer data was processed by The UK Biobank Accelerometer Working Group, including calibration to local gravity, resampling valid data to 100 Hz, applying a 4th order low-pass Butterworth filter to remove machine noise, and removing out or imputing data with…”
Associations between the 24-h Activity Daily Cycle and Incident Dementia
Raichlen, D. A., Aslan, D. H., Sayre, M. K., Nanda, A., Bharadwaj, P. K., Ally, M., Maltagliati, S., Lai, M. H. C., Wilcox, R. R., Klimentidis, Y. C., et al. (2025) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003745 · Cited by 5
Larsen, R. T., Korfitsen, C. B., Juhl, C. B., Andersen, H. B., Langberg, H., & Christensen, J. (2020) · Journal of Aging and Physical Activity · doi:10.1123/japa.2020-0214 · Cited by 4
Figueroa, C. A., Vittinghoff, E., Aguilera, A., & Fukuoka, Y. (2021) · Preventive Medicine Reports · doi:10.1016/j.pmedr.2021.101325 · Cited by 6
“Regarding daily patterns, a UK biobank study of 96,600 individuals found that participants walked slightly less in the weekend, but that this did not differ by gender (Doherty et al., 2017).”
BackgroundLänsitie, M., Niemelä, M., Kangas, M., Venojärvi, M., Härkönen, P. K., Keinanen-Kiukaanniemi, S. M., & Korpelainen, R. (2021) · Translational Sports Medicine · doi:10.1002/tsm2.237 · Cited by 6
Measurement of Physical Activity by Shoe-Based Accelerometers—Calibration and Free-Living Validation
Fridolfsson, J., Arvidsson, D., & Grau, S. (2021) · Sensors · doi:10.3390/s21072333 · Cited by 4
“Nevertheless, most large-scale studies using wrist sensors analyze PA intensity by simple cut-points derived in a similar way as in the current study [30,31].”
ResultObjective assessment of physical activity patterns based on accelerometer and GPS data in adults
Miškinytė, A., & Dėdelė, A. (2021) · Travel Behaviour and Society · doi:10.1016/j.tbs.2021.07.002 · Cited by 4
Connolly, K., Cunningham, C. J., Murphy, N., Romero‐Ortuño, R., & Horgan, F. (2021) · Journal of Frailty Sarcopenia and Falls · doi:10.22540/jfsf-06-098 · Cited by 5
Fiziksel Aktivite Değerlendirmesi: Subjektif ve Objektif Yöntemler
Tümtürk, İ., Özden, F., & Özkeskin, M. (2021) · Journal of Health Services and Education · doi:10.29228/johse.12 · Cited by 8
Orme, M. W., Jayamaha, A. R., Santin, L., Singh, S., & Pitta, F. D. O. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192416986 · Cited by 4
“…accelerometer-based PA measurement continued, comparatively newer devices such as the GeneActiv and Axivity have also become widely used, including in large epidemiological cohorts (e.g., Doherty et al., 2017; Ricardo et al., 2020 [54,56]), but still largely underutilised in CRD populations [57].”
BackgroundMethodBuchan, D. S., & Maylor, B. D. (2023) · Journal of Sports Sciences · doi:10.1080/02640414.2023.2197726 · Cited by 6
Wu, H., & Harezlak, J. (2023) · Physiological Measurement · doi:10.1088/1361-6579/accefe · Cited by 6
“…in large scale observational studies, including The National Health and Nutrition Examination Survey ( NHANES ) ( Troiano et al 2008 ) , UK Biobank ( Doherty et al 2017 ) , Women ’ s Health Initiative ( Evenson et al 2015 ) , Study of Latinos ( SoL ) ( Arredondo et al 2016 ) , among many others.”
Brailey, G., Metcalf, B. S., Price, L., Cumming, S. P., & Stiles, V. H. (2023) · Sensors · doi:10.3390/s23156943 · Cited by 4
Liu, J., Richmond, R. C., Anderson, E. L., Bowden, J., Barry, C.-J. S., Dashti, H. S., Daghlas, I., Lane, J. M., Kyle, S. D., Vetter, C., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-58007-9 · Cited by 6
“It was worn continuously for up to seven days in a sub-sample of participants (n = 103,711) an average of five years after the baseline assessment (range 2.8–8.7 years) 18,46 .”
BackgroundInfluentialGhazi, M. A., Zhou, J., Havens, K. L., & Smith, B. A. (2024) · Sensors · doi:10.3390/s24144436 · Cited by 6
“This is comparable to the 0.128 m/s 2 (13 mg) threshold used by the UK Biobank study on wearable accelerometers [44].”
InfluentialChaurasia, S. K., & Reddy, S. R. N. (2018) · EAI Endorsed Transactions on Pervasive Health and Technology · doi:10.4108/eai.30-10-2018.160460 · Cited by 4
Lok, R., & Zeitzer, J. M. (2020) · Clocks & Sleep · doi:10.3390/clockssleep2040034 · Cited by 4
“Given the advantages of actigraphy, these devices have been used in several large studies to examine longitudinal changes in behavior (e.g., UK Biobank [5], Osteoporotic Fractures in Men [6], Clocks&Sleep 2020, 2, 466–472; doi:10.3390/clockssleep2040034 www.mdpi.com/journal/clockssleep Clocks&Sleep 2020, 2 467 Study o…”
BackgroundInfluentialBeach, C., & Casson, A. J. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3288212 · Cited by 4
“[23], [29]) plot one hour epochs of the accelerometry data, whereas we summarise results on a minute-by-minute basis.”
BackgroundMethodResultInfluentialEllingson, L. D., Hibbing, P. R., Welk, G. J., Dailey, D. L., Rakel, B. A., Crofford, L. J., Sluka, K. A., & Frey‐Law, L. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0062 · Cited by 4
Geoffroy, P. A., Étain, B., & Bellivier, F. (2018) · The Lancet Psychiatry · doi:10.1016/s2215-0366(18)30254-2 · Cited by 4
Semi-unsupervised Learning of Human Activity using Deep Generative ModelsPreprint
Willetts, M., Doherty, A., Roberts, S., & Holmes, C. C. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1810.12176 · Cited by 6
Self-citationAdherence to Personal Health Devices: A Case Study in Diabetes ManagementPreprint
Vhaduri, S., & Prioleau, T. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2006.04947 · Cited by 4
“iption and prescription PHDs. 2.1 Adherence to Non-prescription PHDs Adherence to PHDs has more commonly been studied for consumer wearable systems such as physical activity trackers and smartwatches [11, 12, 16, 20, 24, 40, 43]. Jeong et al. evaluated smartwatch use amongst 50 college students to understand factors t…”
BackgroundResultInfluentialSong, P., Gupta, A., Goon, I. Y., Hasan, M., Mahmood, S., Page, P., Pradeepa, R., Siddiqui, S., Silva, W., Aarthi, G. R., et al. (2020) · medRxiv · doi:10.1101/2020.08.12.20171322 · Cited by 4
Self-citationThomas, J. J. C., Daley, A., Esliger, D., Kettle, V. E., Coombe, A., Stamatakis, E., & Sanders, J. P. (2023) · Journal of Medical Internet Research · doi:10.2196/45599 · Cited by 3
“Wrist-worn devices have been shown to be more acceptable and lead to greater participant compliance [6,144].”
Huang, L., Li, Y., Xu, X., Chen, W., Zhang, Z., Sun, L., & Gao, X. (2024) · Sleep Medicine · doi:10.1016/j.sleep.2024.06.004 · Cited by 4
Chen, N., Si, X., Wang, J., & Chen, W. (2024) · International Journal of COPD · doi:10.2147/copd.s475714 · Cited by 4
Accelerometer‐derived “weekend warrior” and regularly active physical activity and incident diabetes
Lei, L., Li, J., Wang, W., Zhang, L., Meng, X., Xia, C., Li, Y., Zhao, Y., Yuan, X., Wang, X., et al. (2025) · Obesity · doi:10.1002/oby.24278 · Cited by 4
“Briefly, we removed nonwear time and imputed data based on the average of similar time-of-day vectors in the raw data with 5-s epochs [14].”
Shrestha, R. K., Adhikari, T. B., Khatri, B., Neupane, D., Paudel, S., Nielsen, R. O., Skejø, S. D., Vaidya, A., & Kallestrup, P. (2025) · Trials · doi:10.1186/s13063-025-08885-9 · Cited by 3
“Axivity AX3 is a triaxial accelerometer that has been used in large-scale epidemiological studies like the UK and China Biobank studies [52, 53].”
Shan, Y., Gao, H., Wei, Y., Yan, J., Chen, H., & Luo, T. (2025) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000002262 · Cited by 4
Wh, Y., Zhou, P., Xia, R., Dong, H., Wang, X., Ma, H., Gao, X., & Zong, G. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf632 · Cited by 4
Yang, H., Qiao, Y., Lin, R., Yu, Y., Zhao, M., Magnussen, C. G., & Xi, B. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112948 · Cited by 3
Song, Y., Qin, Q., Zhang, L., Liu, X., Zhang, Y., Ying, M., & Yin, P. (2025) · Osteoporosis International · doi:10.1007/s00198-025-07747-z · Cited by 3
Soulier, T., Burgos, N., Hassanaly, R., Pitombeira, M. S., Solal, M., Roy, H., Hamzaoui, M., Yazdan-Panah, A., Faria, D. D. P., Louapre, C., et al. (2025) · Revue Neurologique · doi:10.1016/j.neurol.2025.07.011 · Cited by 4
Yiallourou, S. R., Cribb, L., Campbell‐Brown, B., Brakenridge, C. J., Baril, A., & Pase, M. P. (2025) · BMC Medicine · doi:10.1186/s12916-025-04536-7 · Cited by 4
“A total of 106,053 agreed to take part [14].”
Zhu, Y., Liu, D., Yin, X., Zhang, T. J., & Wu, N. (2026) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2026.200458 · Cited by 3
Wang, L., Qiao, Y., Yu, Y., Zhao, M., Yang, L., & Xi, B. (2026) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwag131 · Cited by 3
Shen, F., Liu, H.-Y., Liu, Y., Yang, J.-Q., Zhang, L.-W., Li, Q.-M., Liu, L., Gong, T.-T., Wu, Q., & Gao, S. (2026) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2025.11.020 · Cited by 4
Brand, Y. E., Buchman, A. S., Kluge, F., Palmerini, L., Becker, C., Cereatti, A., Maetzler, W., Vereijken, B., Yarnall, A. J., Rochester, L., et al. (2026) · npj Digital Medicine · doi:10.1038/s41746-026-02528-2 · Cited by 6
Luo, M., Clare, P. J., Tarp, J., Dalene, K. E., Sánchez-Lastra, M. A., Nguyen, B., Owen, K., Nau, T., Chen, L., Ekelund, U., et al. (2026) · British Journal of Sports Medicine · doi:10.1136/bjsports-2025-110782 · Cited by 3
Huang, H., Liu, J., Li, P., Huang, Z., Yang, C., Qi, L., & Zhou, T. (2026) · Journal of Bone and Mineral Research · doi:10.1093/jbmr/zjag067 · Cited by 4
Joint regression modelling of intensity and timing of accelerometer counts
Geraci, M. (2022) · Statistics in Medicine · doi:10.1002/sim.9633 · Cited by 3
“Estimation of models (6) and (9) for M subjects can be carried”
BackgroundMethodInfluential
Metadata
- Authors
- Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., Preece, S. J., Gillions, R., Sheard, S., Peakman, T., Brage, S., & Wareham, N. J.
- Affiliations
- University of Oxford (GB)
- Newcastle University (GB)
- University of Salford (GB)
- University of Cambridge (GB)
- UK Biobank (GB)
- Corresponding author
- Doherty, Aiden
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-01
- Volume
- 12
- Issue
- 2
- Pages
- e0169649
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5287488
- OpenAlex
- W2584016859
- Cited by
- 1,250
- References
- 22
- Citations by year
- 2026: 180 · 2025: 210 · 2024: 179 · 2023: 142 · 2022: 110 · 2021: 148 · 2020: 108 · 2019: 87 · 2018: 66 · 2017: 20
- FWCI
- 56.84
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Apollo (cc-by)
- Funders
- Wellcome Trust
- Medical Research Council (MC_UU_12015/1, MC_UU_12015/3)
- British Heart Foundation (GB) (RE/13/1/30181)
- Li Ka Shing Foundation (HK)
- Research Councils UK (GB) (EP/G066019/1)
- Engineering and Physical Sciences Research Council (EP/L016176/1)
- National Institute for Health Research (SRF-2011-04-017)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- physical activity, wrist-worn accelerometers, objective physical activity measurement, UK Biobank, age differences in physical activity, sex differences in physical activity, diurnal variation, seasonal variation, vector magnitude, triaxial acceleration
- MeSH terms
- Aged, Female, United Kingdom, Humans, Male, Middle Aged, Seasons, Time Factors, Wrist Joint, Exercise, Biological Specimen Banks, Accelerometry, Public Health Surveillance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.