Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Physical activity has not been objectively measured in prospective cohorts with sufficiently large numbers to reliably detect associations with multiple health outcomes. Technological advances now make this possible. We describe the methods used to collect and analyse accelerometer measured physical activity in over 100,000 participants of the UK Biobank study, and report variation by age, sex, day, time of day, and season. METHODS: Participants were approached by email to wear a wrist-worn accelerometer for seven days that was posted to them. Physical activity information was extracted from 100Hz raw triaxial acceleration data after calibration, removal of gravity and sensor noise, and identification of wear / non-wear episodes. We report age- and sex-specific wear-time compliance and accelerometer measured physical activity, overall and by hour-of-day, week-weekend day and season. RESULTS: 103,712 datasets were received (44.8% response), with a median wear-time of 6.9 days (IQR:6.5-7.0). 96,600 participants (93.3%) provided valid data for physical activity analyses. Vector magnitude, a proxy for overall physical activity, was 7.5% (2.35mg) lower per decade of age (Cohen's d = 0.9). Women had a higher vector magnitude than men, apart from those aged 45-54yrs. There were major differences in vector magnitude by time of day (d = 0.66). Vector magnitude differences between week and weekend days (d = 0.12 for men, d = 0.09 for women) and between seasons (d = 0.27 for men, d = 0.15 for women) were small. CONCLUSIONS: It is feasible to collect and analyse objective physical activity data in large studies. The summary measure of overall physical activity is lower in older participants and age-related differences in activity are most prominent in the afternoon and evening. This work lays the foundation for studies of physical activity and its health consequences. Our summary variables are part of the UK Biobank dataset and can be used by researchers as exposures, confounding factors or outcome variables in future analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This protocol was, for example, utilized in the UK Biobank study, which recorded accelerometer data from approx.90𝑘 participants, resulting in around 20TB of sensor data [46,198].”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Large-scale data collection efforts by the wearables community, e.g., the GLOBEM dataset [206] and the UK Biobank project [46,198], demonstrated the relative ease of collecting wearable movement in the wild, albeit without annotations.”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To ensure data quality, the study implemented stringent criteria in accordance with the UK Biobank accelerometer expert working group's guidelines.25”
From Accelerometer-measured physical activity, sedentary behavior, and incidence of macrovascular and microvascular events in individuals with type 2 diabetes mellitus and prediabetes (2025) · cites this paper as [25]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [24]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 3×
“Cohort studies which include hundreds of thousands of participants followed up over time are required in order to describe the relationship between physical activity and health outcomes that have a number of potential lifestyle, environmental, and genomic causes [12].”
BackgroundInfluentialSelf-citation‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“We have not generalised the overall descriptive findings to the UK population since the UK Biobank was established as an aetiological study rather than one aimed at population surveillance [5,7].”
BackgroundMethodResultFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Colley, R. C., Garriguet, D., Janssen, I., Craig, C. L., Clarke, J., & Tremblay, M. S. (2011) · PubMed · Cited by 1,096
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citation
Research works printed but not linked: 1
- Ladha C, Ladha K, Jackson D, Olivier P. Shaker Table Validation Of Openmovement Ax3 Accelerometer. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement. Amherst, MA, USA; 2013. pp. 69–70. Available: http://www.umass.edu/sphhs/sites/default/files/ICAMPAM Poster Session Abstracts 4-24.pdf
Cited by
Items 301–400 of 1,009
Detecting sleep outside the clinic using wearable heart rate devices
Perez-Pozuelo, I., Posa, M., Spathis, D., Westgate, K. L., Wareham, N. J., Mascolo, C., Brage, S., & Palotti, J. (2022) · Scientific Reports · doi:10.1038/s41598-022-11792-7 · Cited by 33
Self-citationTian, C., Bürki, C., Westerman, K. E., & Patel, C. J. (2023) · Diabetologia · doi:10.1007/s00125-023-06001-7 · Cited by 31
“…accelerometer data were pre-processed by the Biobank Accelerometer Analysis software (https:// github. com/ OxWea rables/ bioba nkAcc elero meter Analy sis, accessed on 1 May 2021) followed by metabolic equivalent of task (MET) calculation as described by Doherty et al and Le Goallec et al [2, 3].”
BackgroundMethodInfluentialHillsdon, M., & Foster, C. (2018) · Journal of Frailty, Sarcopenia and Falls · doi:10.22540/jfsf-03-066 · Cited by 30
Information bias in measures of self-reported physical activity
Folley, S., Zhou, A., & Hyppönen, E. (2018) · International Journal of Obesity · doi:10.1038/s41366-018-0223-x · Cited by 32
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
“Wrist-worn accelerometers are increasingly being used within large-scale population surveillance research [11,16].”
InfluentialBiswas, R. K., Ahmadi, M. N., Bauman, A. E., Milton, K. E., Koemel, N. A., & Stamatakis, E. (2025) · Nature Communications · doi:10.1038/s41467-025-63475-2 · Cited by 41
“From 2013 to 2015, a total of 103,684 UK Biobank participants wore a wrist-worn accelerometer on their dominant wrist for 24 h a day over a period of 7 days 25 , in line with previous studies 12,13 .”
Ferguson, L. D., Ntuk, U. E., Celis-Morales, C. A., Mackay, D., Pell, J. P., Gill, J. M. R., & Sattar, N. A. (2017) · Diabetic Medicine · doi:10.1111/dme.13551 · Cited by 30
24-h Movement and Nonmovement Behaviors in Older Adults. The IMPACT65+ Study
Cabanas‐Sánchez, V., Higueras‐Fresnillo, S., la Cámara, M. Á. D., Esteban‐Cornejo, I., & Martínez‐Gómez, D. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001838 · Cited by 33
Real-World Gait Bout Detection Using a Wrist Sensor: An Unsupervised Real-Life Validation
Soltani, A., Paraschiv-Ionescu, A., Dejnabadi, H., Marques-Vidal, P. M., & Aminian, K. (2020) · IEEE Access · doi:10.1109/access.2020.2998842 · Cited by 32
“Owing to the research-grade PA trackers, which allow the access to raw IMU data, big cohort databases have been created worldwide that contain long-term real-life wrist IMU/acceleration data of thousands of people [57]–[59].”
BackgroundAn Automatic Gait Analysis Pipeline for Wearable Sensors: A Pilot Study in Parkinson’s Disease
Peraza, L. R., Kinnunen, K. M., McNaney, R., Craddock, I. J., Whone, A. L., Morgan, C., Joules, R., & Wolz, R. (2021) · Sensors · doi:10.3390/s21248286 · Cited by 31
“AX3 datasets were resampled to 100 Hz using spline interpolation [25], and GENEActiv datasets were not resampled.”
MethodFarrahi, V., Rostami, M., Dumuid, D., CHASTIN, S. F. M., Niemelä, M., Korpelainen, R., Jämsä, T. J., & Oussalah, M. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003008 · Cited by 33
“Further complicating this, there appears to be considerable variation in sedentary time, LPA, and MVPA between weekend days (Saturday and Sunday) (11), and this variation may potentially be related to cardiometabolic health.”
BackgroundInfluentialBurton, C. D., Dawes, H., Goodwill, S. R., Thelwell, M., & Dalton, C. (2023) · PLoS ONE · doi:10.1371/journal.pone.0280343 · Cited by 35
“00 for adults aged 45–64 was between 40 and 50 milligravitational units [40].”
BackgroundAdvances and Controversies in Diet and Physical Activity Measurement in Youth
Spruijt‐Metz, D., Wen, C. K. F., Bell, B. M., Intille, S. S., Huang, J. S., & Baranowski, T. (2018) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2018.06.012 · Cited by 34
Zhong, Q., Zhou, R., Huang, Y., Chen, H.-W., Liu, H., Huang, Z., Yuan, Z., Wu, K., Cao, B., Liu, K., et al. (2023) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-023-01464-8 · Cited by 29
“Exposure assessment Axivity AX3 wrist-worn triaxial accelerometer was used to measure TPA, with participants requested to wear the monitor continuously for 7 days on their dominant wrist [32].”
MethodSmall, S. R., Chan, S., Walmsley, R., von Fritsch, L., Acquah, A., Mertes, G., Feakins, B. G., Creagh, A. P., Strange, A., Matthews, C. E., et al. (2024) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003478 · Cited by 57
“…researchers most commonly report device-measured activity in terms of overall acceleration or time-use behaviors derived from intensity thresholds (4), the reporting of steps is a more intuitive measure of physical activity intrinsically linked to the key biomechanical feature of human gait (5).”
BackgroundSelf-citationLight Exposure at Night and Cardiovascular Disease Incidence
Windred, D. P., Burns, A. C., Rutter, M. K., Lane, J. M., Saxena, R., Scheer, F. A. J. L., Cain, S. W., & Phillips, A. J. K. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.39031 · Cited by 44
Tin, S. T., REEVES, G. K., & Key, T. J. (2020) · International Journal of Cancer · doi:10.1002/ijc.33010 · Cited by 32
Sexton, C. E., Betts, J. F., Dennis, A., Doherty, A., Leeson, P., Holloway, C. J., Dall’Armellina, E., Winkler, A. M., Demnitz, N., Wassenaar, T. M., et al. (2020) · Physiology & Behavior · doi:10.1016/j.physbeh.2020.112923 · Cited by 35
Self-citationJones, S. L., Hue, W., Kelly, R., Barnett, R., Henderson, V., & Sengupta, R. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3448093 · Cited by 36
“Moreover, previous research has typically focused on adherence regarding the use of devices that automatically log physical activity data, including commercial Fitbits [59, 88] and other wrist-worn trackers [23, 47, 89].”
BackgroundFractal motor activity regulation and sex differences in preclinical Alzheimer's disease pathology
Gao, L., Li, P., Gaba, A., Musiek, E. S., Ju, Y. S., & Hu, K. (2021) · Alzheimer s & Dementia Diagnosis Assessment & Disease Monitoring · doi:10.1002/dad2.12211 · Cited by 35
IoT-Enabled Gait Assessment: The Next Step for Habitual Monitoring
Young, F., Mason, R., Morris, R., Stuart, S., & Godfrey, A. (2023) · Sensors · doi:10.3390/s23084100 · Cited by 39
“Subsequently, a manual data extraction and analysis process may occur, which equates to an inefficient process [78–80].”
MethodLiao, Q., He, J., & Huang, K. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.991140 · Cited by 31
“For the accelerometry-based PAs, exercise data were recorded from a wrist-worn Axivity-AX3 accelerometer (Doherty et al., 2017).”
MethodStamatakis, E., Koemel, N. A., Biswas, R. K., Ahmadi, M. N., Allman-Farinelli, M. A., Trost, S. G., Eroglu, E. I., Cruz, B. D. P., Bin, Y. S., Postnova, S., et al. (2025) · BMC Medicine · doi:10.1186/s12916-024-03833-x · Cited by 31
Mielke, G. I., de Almeida Mendes, M., Ekelund, U., Rowlands, A. V., Reichert, F. F., & Crochemore‐Silva, I. (2023) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.14416 · Cited by 26
Zhu, J., Chen, W., Yuanjia, H., Qu, Y., Yang, H., Zeng, Y., Hou, C., Ge, F., Zhou, Z., & Song, H. (2022) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2022.04.004 · Cited by 28
Sansom, K., Reynolds, A. C., McVeigh, J. A., Mazzotti, D. R., Dhaliwal, S. S., Maddison, K. J., Walsh, J. H., Singh, B., Eastwood, P. R., & McArdle, N. (2023) · SLEEP Advances · doi:10.1093/sleepadvances/zpad028 · Cited by 32
“Indeed, this approach has proved useful for large cohort studies without a sleep diary including the UK Biobank [35] and the US National Health and Nutrition Examination Survey [36].”
MethodAssociation of physical activity pattern and risk of Parkinson’s disease
Lin, F., Lin, Y., Chen, L., Huang, T., Lin, T., He, J., Lu, X., Chen, X., Wang, Y.-Q., Ye, Q., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01135-3 · Cited by 31
“A previous study validated the reliability of this instru-mentforrecordingexerciseduration 17 .”
ResultEquivalency of Sleep Estimates: Comparison of Three Research-Grade Accelerometers
Plekhanova, T., Rowlands, A. V., Yates, T. E., Hall, A. P., Brady, E. M., Davies, M. J., Khunti, K., & Edwardson, C. L. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0047 · Cited by 28
Meisinger, C., Linseisen, J., Leitzmann, M. F., Baurecht, H., & Baumeister, S. E. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2020-001896 · Cited by 33
Sanders, A., Richard, G., Kolskår, K. K., Ulrichsen, K. M., Kaufmann, T., Alnæs, D., Beck, D., Dørum, E. S., de Lange, A. G., Nordvik, J. E., et al. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102767 · Cited by 35
“Results were doubled to capture the number of steps taken by each participant (Doherty et al., 2017).”
BackgroundData Analytics in Physical Activity Studies With Accelerometers: Scoping Review
Liang, Y., Wang, C. I., & Hsiao, C. K. (2024) · Journal of Medical Internet Research · doi:10.2196/59497 · Cited by 34
Heron, N., Kee, F., Mant, J., Cupples, M., & Donnelly, M. (2019) · British Journal of General Practice · doi:10.3399/bjgp19x705509 · Cited by 26
Owens, A. P., Hinds, C., Manyakov, N. V., Stavropoulos, T. G., Lavelle, G., Gove, D., Diaz-Ponce, A. M., & Aarsland, D. (2020) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2020.582207 · Cited by 33
Polygenic Score for Physical Activity Is Associated with Multiple Common Diseases
Sillanpää, E., Palviainen, T., Ripatti, S., Kujala, U. M., & Kaprio, J. A. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002788 · Cited by 26
“The PA PRS, which was recently developed for continuous accelerometer-based overall PA volume (7,25), was adapted to the FinnGen cohort.”
MethodAarts, E., Akkerman, A., Altgassen, M., Bartels, R., Beckers, D. G. J., Bevelander, K. E., Bijleveld, E., Davidson, E. N. B., Boleij, A., Bralten, J., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0260952 · Cited by 28
Accurate Step Count with Generalized and Personalized Deep Learning on Accelerometer Data
Luu, L., Pillai, A., Lea, H., Buendía, R., Khan, F. M., & Dennis, G. (2022) · Sensors · doi:10.3390/s22113989 · Cited by 27
Increasing the use of mobile technology–derived endpoints in clinical trials
Herrington, W. G., Goldsack, J. C., & Landray, M. (2018) · Clinical Trials · doi:10.1177/1740774518755393 · Cited by 24
Orang Asli Health and Lifeways Project (OA HeLP): a cross-sectional cohort study protocol
Wallace, I. J., Lea, A. J., Lim, Y. A. L., Chow, S. K. W., Sayed, I. B. M., Ngui, R., Shaffee, M. T. H., Ng, K.-S., Nicholas, C., Venkataraman, V. V., et al. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-058660 · Cited by 33
Estimating the effect of physical activity on cognitive function within the UK Biobank cohort
Campbell, T., & Cullen, B. (2023) · International Journal of Epidemiology · doi:10.1093/ije/dyad009 · Cited by 32
“The Axivity AX3 wrist-worn triaxial device recorded accelerations over 5-s periods (measured in milligravity, mg, units), resulting in 120 960 data points per participant.(18) Mean daily accelerations per day were derived for use in analysis.”
MethodResultAhn, H., Choi, E., Rhee, T., Choi, J., Lee, K., Kwon, S., Lee, S., Oh, S., & Lip, G. Y. H. (2024) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-106862 · Cited by 28
Liu, C., Yang, Z., He, L., Xiao, Y., Zhao, H., Zhang, L., Liu, Y., Chen, R., Zhang, K., & Luo, B. (2024) · European Review of Aging and Physical Activity · doi:10.1186/s11556-024-00362-7 · Cited by 26
“A subset of 103,659 participants also engaged in an accelerometer-based physical activity study between 2013 and 2015 [16].”
BackgroundSleep Duration Irregularity and Risk for Incident Cardiovascular Disease in the UK Biobank
Huang, T., Kianersi, S., Wang, H., Potts, K. S., Noordam, R., Sofer, T., Rutter, M. K., & Redline, S. S. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.124.040027 · Cited by 31
Daily metabolic expenditures: estimates from US, UK and polish time-use data
Harms, T. A., Berrigan, D. A., & Gershuny, J. (2019) · BMC Public Health · doi:10.1186/s12889-019-6762-9 · Cited by 28
Li, X., & Zhao, H. (2020) · PLoS Genetics · doi:10.1371/journal.pgen.1009089 · Cited by 27
“Besides genetic data, a subset of 103,712 UK Biobank participants agreed to have their objective physical activity data [80] collected, and they were asked to wear an Axivity AX3 wrist accelerometer for seven consecutive days from 2013 to 2015.”
Schwendinger, F., Wagner, J., Infanger, D., Schmidt‐Trucksäss, A., & Knaier, R. (2021) · BMC Medical Research Methodology · doi:10.1186/s12874-021-01350-6 · Cited by 25
“Health and Nutrition Examination Survey [8], or the UK Biobank study [9].”
Liu, M., Gan, X., Ye, Z., Zhang, Y., He, P., Zhou, C., Yang, S., Zhang, Y., & Qin, X. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00969-7 · Cited by 27
“…before or after calibration, if the wear-time was insuf fi cient (de fi ned as the unavailability of at least 72 h of data or did not have data in each 1-hour period of the 24-hour cycle), if the average acceleration was implausibly high (>100 milli-gravity), or if the fi le failed to process 39,40 .”
BackgroundTransforming Big Data into AI‐ready data for nutrition and obesity research
Thomas, D. M., Knight, R. D., Gilbert, J. A., Cornelis, M. C., Gantz, M. G., Burdekin, K., Cummiskey, K., Sumner, S., Pathmasiri, W., Sazonov, E. E., et al. (2024) · Obesity · doi:10.1002/oby.23989 · Cited by 27
“Some studies such as the UK Biobank Study (collected at 100 Hz for over 100,000 participants) [ 76] and the 2011 to 2014 NHANES cycles (collected at 80 Hz for over 18,000 participants) [ 77] include large population sample sizes, vastly increasing data volume.”
BackgroundSelf-supervised Learning for Accelerometer-based Human Activity Recognition: A Survey
Logacjov, A. (2024) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3699767 · Cited by 40
Spatial-Temporal Masked Autoencoder for Multi-Device Wearable Human Activity Recognition
Miao, S., Chen, L., & Hu, R. (2023) · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies · doi:10.1145/3631415 · Cited by 23
“It would be meaningful to conduct pre-training on a large dataset (e.g., the UK Biobank dataset [17]) to make it applicable to multiple activity recognition tasks [76].”
BackgroundLiang, Y. Y., He, Y., Huang, P., Feng, H., Li, H., Ai, S., Du, J., Xue, H., Liu, Y., Zhang, J., et al. (2025) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.100973 · Cited by 25
“25 The present study focused on total volume of PA, MVPA, LPA, and SB. Total volume of PA was measured as the weekly average vector magnitude in mg units.”
Theory-based habit modeling for enhancing behavior prediction in behavior change support systems
Zhang, C., Vanschoren, J., van Wissen, A., Lakens, D., de Ruyter, B., & IJsselsteijn, W. A. (2022) · User Modeling and User-Adapted Interaction · doi:10.1007/s11257-022-09326-x · Cited by 35
“The Axivity AX3 sensor is a 3-axis accelerometer developed by Newcastle University specifically for scientific research on human movements (Doherty et al. 2017).”
Goodman, M. O., Dashti, H. S., Lane, J. M., Windred, D. P., Burns, A. C., Jones, S. E., Sofer, T., Purcell, S., Zhu, X., Ollila, H. M., et al. (2023) · Journal of the American Heart Association · doi:10.1161/jaha.122.030568 · Cited by 24
“Accelerometry data collection, 23,24 processing, 25,26 and validation against polysomnography 26 has been described previously.”
Zaccardi, F., Rowlands, A. V., Dempsey, P. C., Razieh, C., Henson, J. J., Goldney, J., Maylor, B. D., Bhattacharjee, A., Chudasama, Y., Edwardson, C. L., et al. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.100970 · Cited by 30
“19 A 7-day window of accelerometer wear may not reflect longer-term PA patterns.”
Migueles, J. H., Molina-Garcia, P., Torres-Lopez, L. V., Cadenas-Sanchez, C., Rowlands, A. V., Ebner-Priemer, U. W., Koch, E. D., Reif, A., & Ortega, F. B. (2022) · Scientific Reports · doi:10.1038/s41598-022-09469-2 · Cited by 22
Small, S. R., Chan, S., Walmsley, R., Fritsch, L. V., Acquah, A., Mertes, G., Feakins, B. G., Creagh, A., Strange, A., Matthews, C. E., et al. (2023) · doi:10.1101/2023.02.20.23285750 · Cited by 22
Self-citationSelfPAB: large-scale pre-training on accelerometer data for human activity recognition
Logacjov, A., Herland, S., Ustad, A., & Bach, K. (2024) · Applied Intelligence · doi:10.1007/s10489-024-05322-3 · Cited by 35
“Yuan et al. [49] used three transformations of Saeed et al. [35] to pre-train a ResNet-V2 with 18 layers [16] on the large-scale UK-Biobank single-accelerometer recordings [10].”
Accounting for Time: Circadian Rhythms in the Time of COVID-19
Sengupta, S., Brooks, T. G., Grant, G. R., & FitzGerald, G. A. (2020) · Journal of Biological Rhythms · doi:10.1177/0748730420953335 · Cited by 23
“Approximately 100,000 participants in the UK Biobank have activity measurement for 1 week using a wrist-worn accelerometer device (Doherty et al., 2017).”
MethodSocio-demographic determinants of physical activity and app usage from smartphone data
Pontin, F. L., Lomax, N., Clarke, G., & Morris, M. A. (2021) · Social Science & Medicine · doi:10.1016/j.socscimed.2021.114235 · Cited by 26
Clevenger, K. A., Montoye, A. H. K., Camp, C. A. V., Strath, S. J., & Pfeiffer, K. A. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac89c9 · Cited by 25
“While use of raw acceleration facilitates transportability ofmodels across device brands (Rowlands et al 2018), it was surprising that nomodels using the Axivitymonitor were available for inclusion in the repository givenAxivity’s use in the UKBiobank study (Doherty et al 2017).”
MethodUnderstanding of the Single-Item Physical Activity Question for Population Surveillance
Bauman, A. E., & Richards, J. A. (2022) · Journal of Physical Activity and Health · doi:10.1123/jpah.2022-0369 · Cited by 22
Sherry, A. P., Willis, S. A., Yates, T., Johnson, W., Razieh, C., Sargeant, J. A., Malaikah, S., Stensel, D. J., Aithal, G. P., & King, J. A. (2023) · JHEP Reports · doi:10.1016/j.jhepr.2022.100622 · Cited by 22
Bate, G., Kirk, C., Rehman, R. Z. U., Guan, Y., Yarnall, A. J., Din, S. D., & Lawson, R. A. (2023) · Sensors · doi:10.3390/s23104881 · Cited by 33
Huang, Y., & Lu, Z. (2024) · Scientific Reports · doi:10.1038/s41598-024-78360-z · Cited by 32
“A study using the UK Biobank database found that men spent more time than women in low-level or sedentary physical activity, while women spent more time in moderate-level activity 27 .”
Probabilistic Modelling of Gait for Robust Passive Monitoring in Daily Life
Raykov, Y. P., Evers, L. J. W., Badawy, R., Bloem, B. R., Heskes, T., Meinders, M. J., Claes, K., & Little, M. A. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3037857 · Cited by 26
Device-measured movement behaviours in over 20,000 China Kadoorie Biobank participants
Chen, Y., Chan, S., Bennett, D., Chen, X., Wu, X., Ke, Y., Lv, J., Sun, D., Pan, L., Pei, P., et al. (2023) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-023-01537-8 · Cited by 35
“To account for potential wear-time diurnal bias, recording interruptions and non-wear-time were imputed using the average values from the corresponding minute of the day on the remaining days of worn data as in the previous study [12].”
MethodResultInfluentialSelf-citationClassification and Processing of 24-Hour Wrist Accelerometer Data
Pulakka, A., Shiroma, E. J., Harris, T. B., Pentti, J., Vahtera, J., & Stenholm, S. (2018) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2017-0008 · Cited by 23
Study protocol: health survey of Sao Paulo: ISA-Physical Activity and Environment
Florindo, A. A., Teixeira, I. P., Barrozo, L. V., Sarti, F. M., Fisberg, R. M., Andrade, D. R., & García, L. (2021) · BMC Public Health · doi:10.1186/s12889-021-10262-5 · Cited by 28
Classifying diverse manual material handling tasks using a single wearable sensor
Porta, M., Kim, S., Pau, M., & Nussbaum, M. A. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103386 · Cited by 28
Diurnal Physical Activity Patterns across Ages in a Large UK Based Cohort: The UK Biobank Study
Wrobel, J., Muschelli, J., & Leroux, A. (2021) · Sensors · doi:10.3390/s21041545 · Cited by 22
“[24] describes the exact procedure for deriving the 5-second level data from the raw data and estimating periods of non-wear.”
BackgroundInfluentialBarkley, J. E., Glickman, E. L., Fennell, C., Kobak, M. S., Frank, M. L., & Farnell, G. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1523039 · Cited by 22
Jones, S. E., Lane, J. M., Ar, W., van Hees, V. T., Tyrrell, J., Beaumont, R. N., Jeffries, A. R., Dashti, H. S., Hillsdon, M. M., Ruth, K. S., et al. (2019) · Yearbook of pediatric endocrinology · doi:10.1530/ey.16.1.1 · Cited by 26
Grimes, L. A., Outtrim, J. G., Griffin, S. J., & Ercole, A. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-032346 · Cited by 21
Posture and Physical Activity Detection: Impact of Number of Sensors and Feature Type
Tang, Q., John, D., Thapa-Chhetry, B., ARGUELLO, D. J., & Intille, S. S. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002306 · Cited by 26
Buchan, D. S., Boddy, L. M., & McLellan, G. (2020) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2020.1801441 · Cited by 24
Ravalli, S., Roggio, F., Lauretta, G., Rosa, M. D., D’Amico, A. G., D’Agata, V., Maugeri, G., & Musumeci, G. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e08991 · Cited by 24
Lentzen, M., Vairavan, S., Muurling, M., Alepopoulos, V., Atreya, A., Boada, M., de Boer, C., Conde, P., Curcic, J., Frisoni, G. B., et al. (2025) · Alzheimer s Research & Therapy · doi:10.1186/s13195-025-01675-0 · Cited by 24
“Previous research has already demonstrated the device’s suitability for this type of research [23].”
Stronger Associations Between Sleep and Mental Health in Adults with Autism: A UK Biobank Study
Henderson, L. M., Clair, M. S., Knowland, V. C. P., van Rijn, E., Walker, S., & Gaskell, M. G. (2021) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-021-05382-1 · Cited by 24
Clustering Accelerometer Activity Patterns from the UK Biobank Cohort
Clark, S., Lomax, N., Morris, M. A., Pontin, F. L., & Birkin, M. H. (2021) · Sensors · doi:10.3390/s21248220 · Cited by 21
“The processing of these data is described in Doherty, Jackson [10].”
MethodInfluentialDetection of Parkinson’s Disease Using Wrist Accelerometer Data and Passive Monitoring
Rastegari, E., Ali, H., & Marmelat, V. (2022) · Sensors · doi:10.3390/s22239122 · Cited by 26
“[11], in which they used the Biobank dataset [19] collected from the participants’ dominant wrist.”
A survey of artificial intelligence in gait-based neurodegenerative disease diagnosis
Rao, H., Zeng, M., Zhao, X., & Miao, C. (2025) · Neurocomputing · doi:10.1016/j.neucom.2025.129533 · Cited by 33
Andreu-Pérez, J., Garcia‐Gancedo, L., McKinnell, J., van der Drift, A., Powell, A., Hamy, V., Keller, T., & Yang, G. (2017) · Sensors · doi:10.3390/s17092113 · Cited by 22
Hajna, S., White, T., Panter, J., Brage, S., Wijndaele, K., Woodcock, J., Ogilvie, D., Imamura, F., & Griffin, S. J. (2019) · International Journal of Epidemiology · doi:10.1093/ije/dyz065 · Cited by 24
Self-citationKastelic, K., Dobnik, M., Löfler, S., Höfer, C., & Šarabon, N. (2021) · Sensors · doi:10.3390/s21186245 · Cited by 24
“Technological development led to miniaturizing devices, expanding the battery life, computing diverse movement behaviors and computing vital signs metrics, while becoming affordable for the use in large-scale studies [6], clinical applications [7] or for individual”
BackgroundLok, R., Weed, L., Winer, J. R., & Zeitzer, J. M. (2024) · Psychiatry Research · doi:10.1016/j.psychres.2024.115956 · Cited by 23
Sutin, A. R., Luchetti, M., Stéphan, Y., & Terracciano, A. (2021) · Mental health and physical activity · doi:10.1016/j.mhpa.2021.100412 · Cited by 22
Edwardson, C. L., Maylor, B. D., Dawkins, N. P., Plekhanova, T., & Rowlands, A. V. (2021) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2021.1944154 · Cited by 24
“All accelerometers were configured on the same PC in the dynamic range ± 8 g and to record at a frequency of 100 Hz to reflect common practice (e.g., Doherty et al., 2017; Fairclough et al., 2019; Rowlands et al., 2018b).”
MethodLarsen, R. T., Korfitsen, C. B., Keller, C., Christensen, J., Andersen, H. B., Juhl, C., & Langberg, H. (2021) · European Review of Aging and Physical Activity · doi:10.1186/s11556-021-00269-7 · Cited by 19
Xiao, Q., Lu, J., Zeitzer, J. M., Matthews, C. E., Saint‐Maurice, P. F., & Bauer, C. (2022) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-022-01274-4 · Cited by 29
“For gender, we found a lower amplitude in men, similar to previous studies that reported lower levels of total activity measured by wrist actigraphy in men than in women [27, 28].”
ResultCrowley, P., Ikeda, E., Islam, S. M. S., Kildedal, R., Jacobsen, S. S., Larsen, J. R., Johansson, P. J., Hettiarachchi, P., Aadahl, M., Mork, P. J., et al. (2022) · JMIR Research Protocols · doi:10.2196/35697 · Cited by 24
Brand, Y. E., Kluge, F., Palmerini, L., Paraschiv-Ionescu, A., Becker, C., Cereatti, A., Maetzler, W., Sharrack, B., Vereijken, B., Yarnall, A. J., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-71491-3 · Cited by 19
Mielke, G. I., Menezes, A. M. B., SILVA, B. G. C. D., Ekelund, U., Crochemore‐Silva, I., Wehrmeister, F. C., Gonçalves, H., & Brown, W. J. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002696 · Cited by 19
Dashti, H. S., Jones, S. E., Wood, A. R., Lane, J. M., van Hees, V. T., Wang, H., Rhodes, J. A., Song, Y., Patel, K., Anderson, S. G., et al. (2018) · doi:10.1101/274977 · Cited by 614
Self-citationChristiansen, L. B., Koch, S., Bauman, A. E., Toftager, M., Petersen, C. B., & Schipperijn, J. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1236870 · Cited by 26
Finely Tuned γ Tracks Medication Cycles in Parkinson's Disease: An Ambulatory Brain‐Sense Study
Colombo, A., Bernasconi, E., Alva, L., Sousa, M., Debove, I., Nowacki, A., Serquet, C., Petermann, K., Nguyen, T. A. K., Magalhães, A. D., et al. (2025) · Movement Disorders · doi:10.1002/mds.30160 · Cited by 24
Koemel, N. A., Biswas, R. K., Ahmadi, M. N., Teixeira-Pinto, A. M., Hamer, M., Rezende, L. F. M., Mitchell, J. J., Leech, R. M., Sawan, M. J., Allman-Farinelli, M. A., et al. (2026) · EClinicalMedicine · doi:10.1016/j.eclinm.2025.103741 · Cited by 27
“We used data from the UK Biobank accelerometry sub-study, 24 part of a larger cohort comprising 502,629 adults aged 40–69 recruited from 2006 to 2010.”
InfluentialMahmood, S., Nguyen, N. H., Bassett, J. K., MacInnis, R. J., Karahalios, A., Owen, N. G., Bruinsma, F., Milne, R. L., Giles, G. G., English, D. R., et al. (2019) · International Journal of Epidemiology · doi:10.1093/ije/dyz209 · Cited by 20
Porta, M., Orrù, P. F., & Pau, M. (2021) · Ergonomics · doi:10.1080/00140139.2021.1948107 · Cited by 18
Yan, H., Siegel, L., Breitbart, S. C., Gorodetsky, C., Fasano, A. A., Rahim, A., Loh, A., Kulkarni, A. V., & Ibrahim, G. M. (2022) · Pilot and Feasibility Studies · doi:10.1186/s40814-022-00988-3 · Cited by 22
“Actigraphy is the continuous measurement of an individuals’ movement using a device worn similarly to a watch (Axivity AX3 and Axivity AX6) [54, 55].”
MethodDempsey, P. C., Aadland, E., Strain, T., Kvalheim, O. M., Westgate, K. L., Lindsay, T., Khaw, K., Wareham, N. J., Brage, S., & Wijndaele, K. (2022) · Preventive Medicine · doi:10.1016/j.ypmed.2022.106977 · Cited by 24
Self-citationLe, H.-L., Nguyen, D.-N., Nguyen, T.-H., & Nguyen, H.-N. (2022) · Electronics · doi:10.3390/electronics11071030 · Cited by 22
“Low-pass filters are often used to remove high-frequency noise [32,33], eliminate misplacement [34], and remove gravity components [35,36].”
Method
Metadata
- Authors
- Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., Preece, S. J., Gillions, R., Sheard, S., Peakman, T., Brage, S., & Wareham, N. J.
- Affiliations
- University of Oxford (GB)
- Newcastle University (GB)
- University of Salford (GB)
- University of Cambridge (GB)
- UK Biobank (GB)
- Corresponding author
- Doherty, Aiden
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-01
- Volume
- 12
- Issue
- 2
- Pages
- e0169649
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5287488
- OpenAlex
- W2584016859
- Cited by
- 1,250
- References
- 22
- Citations by year
- 2026: 180 · 2025: 210 · 2024: 179 · 2023: 142 · 2022: 110 · 2021: 148 · 2020: 108 · 2019: 87 · 2018: 66 · 2017: 20
- FWCI
- 56.84
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Apollo (cc-by)
- Funders
- Wellcome Trust
- Medical Research Council (MC_UU_12015/1, MC_UU_12015/3)
- British Heart Foundation (GB) (RE/13/1/30181)
- Li Ka Shing Foundation (HK)
- Research Councils UK (GB) (EP/G066019/1)
- Engineering and Physical Sciences Research Council (EP/L016176/1)
- National Institute for Health Research (SRF-2011-04-017)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- physical activity, wrist-worn accelerometers, objective physical activity measurement, UK Biobank, age differences in physical activity, sex differences in physical activity, diurnal variation, seasonal variation, vector magnitude, triaxial acceleration
- MeSH terms
- Aged, Female, United Kingdom, Humans, Male, Middle Aged, Seasons, Time Factors, Wrist Joint, Exercise, Biological Specimen Banks, Accelerometry, Public Health Surveillance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.