Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Physical activity has not been objectively measured in prospective cohorts with sufficiently large numbers to reliably detect associations with multiple health outcomes. Technological advances now make this possible. We describe the methods used to collect and analyse accelerometer measured physical activity in over 100,000 participants of the UK Biobank study, and report variation by age, sex, day, time of day, and season. METHODS: Participants were approached by email to wear a wrist-worn accelerometer for seven days that was posted to them. Physical activity information was extracted from 100Hz raw triaxial acceleration data after calibration, removal of gravity and sensor noise, and identification of wear / non-wear episodes. We report age- and sex-specific wear-time compliance and accelerometer measured physical activity, overall and by hour-of-day, week-weekend day and season. RESULTS: 103,712 datasets were received (44.8% response), with a median wear-time of 6.9 days (IQR:6.5-7.0). 96,600 participants (93.3%) provided valid data for physical activity analyses. Vector magnitude, a proxy for overall physical activity, was 7.5% (2.35mg) lower per decade of age (Cohen's d = 0.9). Women had a higher vector magnitude than men, apart from those aged 45-54yrs. There were major differences in vector magnitude by time of day (d = 0.66). Vector magnitude differences between week and weekend days (d = 0.12 for men, d = 0.09 for women) and between seasons (d = 0.27 for men, d = 0.15 for women) were small. CONCLUSIONS: It is feasible to collect and analyse objective physical activity data in large studies. The summary measure of overall physical activity is lower in older participants and age-related differences in activity are most prominent in the afternoon and evening. This work lays the foundation for studies of physical activity and its health consequences. Our summary variables are part of the UK Biobank dataset and can be used by researchers as exposures, confounding factors or outcome variables in future analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This protocol was, for example, utilized in the UK Biobank study, which recorded accelerometer data from approx.90𝑘 participants, resulting in around 20TB of sensor data [46,198].”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Large-scale data collection efforts by the wearables community, e.g., the GLOBEM dataset [206] and the UK Biobank project [46,198], demonstrated the relative ease of collecting wearable movement in the wild, albeit without annotations.”
From Past, Present, and Future of Sensor-based Human Activity Recognition Using Wearables: A Surveying Tutorial on a Still Challenging Task (2025) · cites this paper as [46]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“To ensure data quality, the study implemented stringent criteria in accordance with the UK Biobank accelerometer expert working group's guidelines.25”
From Accelerometer-measured physical activity, sedentary behavior, and incidence of macrovascular and microvascular events in individuals with type 2 diabetes mellitus and prediabetes (2025) · cites this paper as [25]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [24]
10 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 3×
“Cohort studies which include hundreds of thousands of participants followed up over time are required in order to describe the relationship between physical activity and health outcomes that have a number of potential lifestyle, environmental, and genomic causes [12].”
BackgroundInfluentialSelf-citation‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 3×
“We have not generalised the overall descriptive findings to the UK population since the UK Biobank was established as an aetiological study rather than one aimed at population surveillance [5,7].”
BackgroundMethodResultFit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Colley, R. C., Garriguet, D., Janssen, I., Craig, C. L., Clarke, J., & Tremblay, M. S. (2011) · PubMed · Cited by 1,096
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Shephard, R. J. (2011) · Yearbook of Sports Medicine · doi:10.1016/j.yspm.2011.03.006 · Cited by 877
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citation
Research works printed but not linked: 1
- Ladha C, Ladha K, Jackson D, Olivier P. Shaker Table Validation Of Openmovement Ax3 Accelerometer. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement. Amherst, MA, USA; 2013. pp. 69–70. Available: http://www.umass.edu/sphhs/sites/default/files/ICAMPAM Poster Session Abstracts 4-24.pdf
Cited by
Items 501–600 of 1,009
Chen, J., Wang, Y., Zhong, Z., Chen, X., Zhang, L., Jie, L., Zhang, Y., & Wang, Y. (2025) · Nature Cardiovascular Research · doi:10.1038/s44161-025-00732-z · Cited by 21
Applying Deep Learning Techniques to Estimate Patterns of Musical Gesture
Dalmazzo, D., Waddell, G., & Ramírez, R. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2020.575971 · Cited by 17
“UK Biobank publishes the dataset (Doherty et al., 2017).”
Hsu, W.-C., Sugiarto, T., Liao, Y.-Y., Lin, Y., Yang, F., Hueng, D., Sun, C.-T., & Chou, K.-N. (2021) · Applied Sciences · doi:10.3390/app11041541 · Cited by 15
Eroglu, E. I., Huang, B., Shepherd, L. C., Pearson, N., Koster, A., Palm, P., Cistulli, P. A., Hamer, M., & Stamatakis, E. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0033 · Cited by 12
“However, the wrist-worn accelerometer measures cannot use postural information when estimating sleep or waking state, habitual physical activity and energy expenditure (Doherty et al., 2017).”
BackgroundConnection between sleeping patterns and cognitive deterioration in women with Alzheimer’s disease
Corbí, A., & Burgos, D. (2021) · Sleep And Breathing · doi:10.1007/s11325-021-02327-x · Cited by 12
Recent Academic Research on Clinically Relevant Digital Measures: Systematic Review
Shandhi, M. M. H., Goldsack, J. C., Ryan, K., Bennion, A., Kotla, A. V., Feng, A., Jiang, Y., Wang, W. K., HURST, T. L., Patena, J. V., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/29875 · Cited by 13
Work/household, transport, and leisure domains account for the sex gap in physical activity in Chile
Suárez‐Reyes, M., & Fernández‐Verdejo, R. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.1011790 · Cited by 13
Collings, P. J., Backes, A., Aguayo, G., Malisoux, L., on behalf of the ORISCAV-LUX study group, Alkerwi, A., Noppe, S., Delagardelle, C., Beissel, J., Chioti, A., et al. (2022) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-022-01380-3 · Cited by 17
“2 mg in 45-54y olds) [23], but methodological inconsistencies prevent a direct (like-forlike) comparison of results.”
BackgroundGoallec, A. L., Collin, S., Jabri, M., Diai, S., Vincent, T., & Patel, C. J. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000176 · Cited by 15
“For more details about the device, we refer to Doherty and colleagues [26].”
BackgroundMethodInfluentialMcDonald, L., Oguz, M., Carroll, R., Thakkar, P. K., Yang, F., Dhalwani, N. N., Cox, A., Merinopoulou, E., Malcolm, B., Mehmud, F., et al. (2019) · Future Oncology · doi:10.2217/fon-2019-0443 · Cited by 16
Nakabazzi, B., Wachira, L.-J. M., Oyeyemi, A. L., Ssenyonga, R., & Onywera, V. O. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235211 · Cited by 16
“Despite the increase in the use of accelerometers to quantify children’s physical activity in large population studies, especially in high income countries (HICs) [28,29,30], there are relatively fewer studies that have used accelerometers in low income countries (LICs) [11,20].”
BackgroundOskouei, S. T., Malliaras, P., Hill, K., Clark, R. A., & Perraton, L. G. (2022) · Musculoskeletal Science and Practice · doi:10.1016/j.msksp.2022.102534 · Cited by 13
Correlations in sleeping patterns and circadian preference between spouses
Richmond, R. C., Howe, L. J., Heilbron, K., Jones, S. E., Liu, J., Aslibekyan, S. W., Auton, A., Babalola, E., Bell, R. K., Bielenberg, J., et al. (2023) · Communications Biology · doi:10.1038/s42003-023-05521-7 · Cited by 14
“Details of data collection and processing have been previously described 52 .”
Fully Automated Detection of Isolated Rapid-Eye-Movement Sleep Behavior Disorder Using Actigraphy
Brink-Kjær, A., Winer, J. R., Zeitzer, J. M., Sørensen, H. B. D., Jennum, P., Mignot, E. J.-M., & During, E. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341133 · Cited by 17
“To analyze 24-hour rhythms, the raw accelerometer data was first processed in 30-second epochs using the biobankAcclerometerAnalysis software package in Python [22].”
MethodBai, P., Ning, X., Gao, R., Shao, X., Zhou, S., Li, J., Lin, Y., Liu, H., Zhang, M., & Yu, P. (2023) · Preventive Medicine · doi:10.1016/j.ypmed.2023.107831 · Cited by 16
Montgomery, G., Yusuf, M., Cooper, R., & Ireland, A. (2024) · Journal of Bone and Mineral Research · doi:10.1093/jbmr/zjae017 · Cited by 12
Lettink, A., van Wieringen, W. N., Altenburg, T. M., Chinapaw, M. J. M., & van Hees, V. T. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0003 · Cited by 14
“This will provide insight into the extent to which physical behavior estimates can be compared across these parameters and, consequently, across large data sets, such as the International Study of Childhood, Obesity, Lifestyle and the Environment (Katzmarzyk et al., 2019), the Groningen Expert Centre for Kids with Obe…”
Reliable measures of rest-activity rhythm fragmentation: how many days are needed?
Danilevicz, I. M., Vidil, S., Landré, B., Dugravot, A., van Hees, V. T., & Sabia, S. (2024) · European Review of Aging and Physical Activity · doi:10.1186/s11556-024-00364-5 · Cited by 14
“This approach is commonly used to analyse accelerometer data [23, 35], particularly in the context of physical activity.”
MethodInfluentialBohmann, P., Stein, M. J., Amadou, A., Baurecht, H., Fervers, B., Fontvieille, E., Freisling, H., Friedenreich, C. M., Konzok, J., Peruchet‐Noray, L., et al. (2025) · British Journal of Sports Medicine · doi:10.1136/bjsports-2024-108708 · Cited by 22
Accelerometer‐measured physical activity timing with incident dementia
Ning, Y., Chen, M., Yang, H., & Jia, J. (2025) · Alzheimer s & Dementia · doi:10.1002/alz.14452 · Cited by 13
Accelerometer-Measured Physical Activity and Neuroimaging-Driven Brain Age
Chen, H., Cao, Z., Zhang, J., Li, D., Wang, Y., & Xu, C. (2025) · Health Data Science · doi:10.34133/hds.0257 · Cited by 16
“The UKB collected 7 days of accelerometers from 103,660 participants [ 22 ], with 92,602 participants passing quality con-trol (Supplementary Methods).”
Carpenter, J. S., Crouse, J. J., Park, S. H., Shin, M., Tonini, E., Guo, W., Merikangas, K. R., Iorfino, F., Leroux, A., Nichles, A., et al. (2025) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2025.03.003 · Cited by 18
Ren, R., Wang, W.-X., Liu, Q., Ye, X., Li, X., Zhang, R., Wang, L., Zhang, Y., Ma, Y., & Wang, D. (2025) · Journal of the American Heart Association · doi:10.1161/jaha.124.039852 · Cited by 13
Beale, N., Eldridge, E., Delextrat, A. A., Esser, P., Bushnell, O., Curtis, E., Wassenaar, T. M., Wheatley, C., Johansen‐Berg, H., & Dawes, H. (2021) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2020-000924 · Cited by 16
Frodi, D. M., Kolk, M. Z. H., Langford, J., Andersen, T. O., Knops, R. E., Tan, H. L., Svendsen, J. H., Tjong, F. V. Y., & Diederichsen, S. Z. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.10.002 · Cited by 14
“An important limitation to the study could be suboptimal compliance with the wearables; however, prior studies have indicated high compliance with accelerometers when used for shorter time periods than in our study.(32) It is yet uncertain what noncompliance rate generally applies specifically to a population with an…”
ResultDevelopment of a Novel Accelerometry-Based Performance Fatigability Measure for Older Adults
Qiao, Y., Harezlak, J., Moored, K., Urbanek, J. K., Boudreau, R. M., Toto, P. E., Hawkins, M., Santanasto, A. J., Schrack, J. A., Simonsick, E. M., et al. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002966 · Cited by 13
“Furthermore, it is easier and more accessible to implement wrist-worn accelerometers into the general population and larger research studies, with greater compliance and wear time (25,26).”
BackgroundPhysical activity and risk of gallstone disease: A Mendelian randomization study
Qian, Q., Jiang, H., Cai, B., Chen, D., & Jiang, M. (2022) · Frontiers in Genetics · doi:10.3389/fgene.2022.943353 · Cited by 16
“The accelerometer-measured “overall activity” levels were treated as average vector magnitude for each 30-s epoch (Doherty et al., 2017).”
MethodEsmonde, K., Roth, S. M., & Walker, A. N. (2023) · Technology in Society · doi:10.1016/j.techsoc.2023.102297 · Cited by 16
Association between accelerometer-derived physical activity and incident cardiac arrest
Peng, Z., Nan, W., & Xing, Z. (2023) · EP Europace · doi:10.1093/europace/euad353 · Cited by 13
“11,13 Previous studies mainly focused on long-time VPA because of lack of methods to accurately measure intermittent or short-time VPA, which might draw the conclusion that VPA increases CA incidence.”
BackgroundObjective evaluation of physical activity pattern using smart devices
Šimaitytė, M., Petrėnas, A., Kravčenko, J., Kaldoudi, E., & Marozas, V. (2019) · Scientific Reports · doi:10.1038/s41598-019-38638-z · Cited by 14
Klinedinst, B. S., Meier, N. F., Larsen, B. A., Wang, Y., Yu, S., Mochel, J. P., Le, S. T., Wolf, T., Pollpeter, A., Pappas, C. A., et al. (2020) · Obesity · doi:10.1002/oby.22852 · Cited by 13
Xian, W., Shen, J., Zhou, H., Liu, J., Zhang, Y., Zhang, Z., Zhou, T., Hong, S., Yang, Y., Fang, W., et al. (2020) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-020-03409-1 · Cited by 13
Calibration of the Active Australia questionnaire and application to a logistic regression model
Bassett, J. K., Swain, C. T. V., Hodge, A. M., Mahmood, S., Csizmadi, I., Owen, N. G., Dunstan, D. W., & Lynch, B. M. (2020) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2020.11.007 · Cited by 13
Länsitie, M., Kangas, M., Jokelainen, J. J., Venojärvi, M., Vaaramo, E., Härkönen, P. K., Keinanen-Kiukaanniemi, S. M., & Korpelainen, R. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108937 · Cited by 13
Pagnamenta, S., Grønvik, K. B., Aminian, K., Vereijken, B., & Paraschiv-Ionescu, A. (2022) · Sensors · doi:10.3390/s22031117 · Cited by 11
“Wearable devices, including accelerometers, are the most commonly used tools to objectively evaluate physical activity and mobility in large-scale studies [1].”
BackgroundSangha, N., Lyall, L. M., Wyse, C. A., Cullen, B., Whalley, H. C., & Smıth, D. J. (2022) · Bipolar Disorders · doi:10.1111/bdi.13237 · Cited by 13
Popham, S. F., Burq, M., Rainaldi, E., Shin, S., Dunn, J., & Kapur, R. (2023) · JMIR Biomedical Engineering · doi:10.2196/43726 · Cited by 10
“There have been some examples of reference devices deployed to generate accurate truth labels in generalizable real-world settings [25,26], but this came at the cost of intrusiveness and resource-intensive data processing steps after collection, such as manual video footage tagging.”
BackgroundQiu, S., & Xing, Z. (2025) · Translational Psychiatry · doi:10.1038/s41398-025-03543-9 · Cited by 12
“Detailed methods for data collection and processing have been described in previous studies [19, 20].”
Wei, J., Shen, M., Li, S., Xiao, Y., Luo, D., Ferrari, G., Lee, D. H., Rezende, L. F. M., Gill, J. M. R., Ahmadi, M. N., et al. (2026) · European Heart Journal · doi:10.1093/eurheartj/ehag168 · Cited by 16
Device-measured physical activity and incident affective disorders
Ho, F. K. W., Petermann-Rocha, F. E., Parra-Soto, S. L., Boonpor, J., Gill, J. M. R., Gray, S. R., Pell, J. P., & Celis-Morales, C. A. (2022) · BMC Medicine · doi:10.1186/s12916-022-02484-0 · Cited by 11
“The dominant wrist of each individual was used over a period of 7 days at 100 Hz and combined into 5-s epochs for analysis [16].”
BackgroundMethodMaylor, B. D., Edwardson, C. L., Clarke-Cornwell, A. M., Davies, M. J., Dawkins, N. P., Dunstan, D. W., Khunti, K., Yates, T. E., & Rowlands, A. V. (2023) · Sensors · doi:10.3390/s23177353 · Cited by 11
“Traditionally, accelerometers are worn on the hip; however, other wear locations, such as the wrist and thigh, are being increasingly used for large-scale surveillance [1,2]; wrist-wear is associated with higher participant compliance [3], whereas thigh-wear enables more accurate determination of posture and stepping…”
BackgroundInteractions between age, sex and visceral adipose tissue on brain ageing
Moran, C., Herson, J., Than, S., Collyer, T. A., Beare, R. J., Syed, S., & Srikanth, V. K. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15727 · Cited by 11
Zhao, J., Ke, Z., Huang, R., Wen, X., Liu, W., Wang, S., Zhang, X. D., Zhuang, X., Pan, L., & Liao, L. (2024) · European Review of Aging and Physical Activity · doi:10.1186/s11556-024-00359-2 · Cited by 15
“[15] For measuring accelerometer-based physical activity (average acceleration), 91,084 participants wore an Axivity-AX3 triaxial accelerometer on their wrist for 7 days [16].”
MethodAdverse effects of late sleep on physical health in a large cohort of community-dwelling adults
Lok, R., Weed, L., Winer, J. R., & Zeitzer, J. M. (2024) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2024.12.031 · Cited by 12
Skjødt, M., Brønd, J. C., Tully, M. A., Tsai, L., Koster, A., Visser, M., & Caserotti, P. (2025) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70009 · Cited by 12
Accelerometer-derived “weekend warrior” physical activity, sedentary behavior, and risk of dementia
Ning, Y., Chen, M., Yang, H., & Jia, J. (2025) · Alzheimer s Research & Therapy · doi:10.1186/s13195-024-01657-8 · Cited by 13
“The device recorded triaxial acceleration data at a frequency of 100 Hz over the seven-day period, with a dynamic range of ± 8 g [15].”
Ahern, A. L., Woolston, J., Wells, E. K., Sharp, S. J., Islam, N., Lawlor, E. R., Duschinsky, R., Hill, A. J., Doble, B., Wilson, E., et al. (2020) · BMJ Open · doi:10.1136/bmjopen-2019-035020 · Cited by 10
Nnamoko, N., Cabrera-Diego, L. A., Campbell, D., Sanders, G., Fairclough, S. J., & Korkontzelos, I. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106165 · Cited by 11
Physical activity in relation to circulating hormone concentrations in 117,100 men in UK Biobank
Watts, E. L., Perez‐Cornago, A., Doherty, A., Allen, N. E., Fensom, G. K., Tin, S. T., Key, T. J., & Travis, R. C. (2021) · Cancer Causes & Control · doi:10.1007/s10552-021-01466-6 · Cited by 11
Self-citationZhou, H., Zhu, R., Ung, A., & Schatz, B. R. (2022) · PLOS Digital Health · doi:10.1371/journal.pdig.0000045 · Cited by 11
“Accelerometer data is collected with the Axivity AX3 wrist-worn accelerometer, which collects 100Hz triaxial signals [9].”
BackgroundMethodGuthold, R., Kann, L. K., Bhatti, L. I., Abduvahobov, P., Ansong, J., Atkinson, U., Baltag, V., Caffe, S., Caixeta, R. D. B., Diallo, C. B., et al. (2023) · BMJ Open · doi:10.1136/bmjopen-2022-071353 · Cited by 13
Towards a Portable Model to Discriminate Activity Clusters from Accelerometer Data
Jones, P. J., Mirkes, E. M., Yates, T. E., Edwardson, C. L., Catt, M., Davies, M. J., Khunti, K., & Rowlands, A. V. (2019) · Sensors · doi:10.3390/s19204504 · Cited by 11
Wilson, J. J., Skjødt, M., McMullan, I., Blackburn, N. E., Giné‐Garriga, M., Sansano-Nadal, O., Figuls, M. R. I., Klenk, J., Dallmeier, D., McIntosh, E., et al. (2020) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2019-0037 · Cited by 10
Ratcliffe, A., Zhai, B., Guan, Y., Jackson, D., & Sneyd, J. R. (2020) · Anaesthesia · doi:10.1111/anae.15267 · Cited by 12
“[3] and 4000 participants in a study by Menai et al.”
BackgroundMethodSelf-citationTabacu, L. M., Ledbetter, M. K., Leroux, A., Crainiceanu, C. M., & Smirnova, E. (2020) · Sensors · doi:10.3390/s21010004 · Cited by 14
“Results also agree qualitatively with analyses based on the UK Biobank [37] study using time-to-event analysis.”
BackgroundRamalho, A. L. G., Petrica, J., Serrano, J., Paulo, R. M., Duarte‐Mendes, P., & Rosado, A. F. B. (2021) · Retos · doi:10.47197/retos.v42i0.86299 · Cited by 14
“No entanto, para melhor compreender as associações entre o comportamento sedentário e os resultados de saúde biopsicossociais, torna-se necessário verificar os níveis de atividade física dos indivíduos em estudo (Doherty et al., 2017).”
BackgroundGenetically predicted physical activity is associated with lower serum urate concentrations
Guan, Y., Wei, J., Meng, L., Li, Y., Wang, T., Chen, D., & Qian, Q. (2022) · Genes & Genomics · doi:10.1007/s13258-022-01239-8 · Cited by 11
“…PA, participants were required to wear an Axivity AX3 triaxial accelerometer all time for at least seven-dayperiod between 2013 and 2015 (Doherty et al. 2017). by lower PA itself, but due to obesity which resulted from lower PA level), and reverse causality (e.g., gout causes joint pain…”
BackgroundSirignano, L., Streit, F., Frank, J., Zillich, L., Witt, S. H., Rietschel, M., & Foo, J. C. (2022) · Scientific Reports · doi:10.1038/s41598-022-19720-5 · Cited by 13
Ye, R., Yang, H., Li, S., Ji, C., Chen, L., Zhao, Y., Zhao, L., & Xia, Y. (2024) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwae273 · Cited by 10
Gong, X., Eminson, K., Atilola, G. O., Jephcote, C., Adams, K., Captur, G., Hall, A. P., Blangiardo, M., Gulliver, J., Rowlands, A. V., et al. (2024) · Environmental Health Perspectives · doi:10.1289/ehp14156 · Cited by 13
“15 However, actigraphy has the advantage of being easily performed in larger samples while preserving participants ’ natural sleep habits in their homes.”
Polo‐López, A., Calatayud, J., Palau, P., López, L., Núñez‐Cortés, R., Andersen, L. L., & López‐Bueno, R. (2024) · Clinical Nutrition · doi:10.1016/j.clnu.2024.10.022 · Cited by 11
Zhao, A., Cui, E., Leroux, A., Zhou, X., Muschelli, J., Lindquist, M. A., & Crainiceanu, C. M. (2024) · The Journals of Gerontology Series A · doi:10.1093/gerona/glae287 · Cited by 15
Haddadj, R., Verdot, C., Salanave, B., Deschamps, V., & Vanhelst, J. (2024) · PLoS ONE · doi:10.1371/journal.pone.0316176 · Cited by 10
Liao, D., Chen, H.-J., Li, H., Gao, J., Tang, X.-L., Du, L., Lai, S., Zhong, W.-F., Huang, H.-X., Xiong, Z.-Y., et al. (2025) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-025-01734-7 · Cited by 10
“The accelerometer substudy invited participants to wear Axivity AX triaxial accelerometers [24] on their dominant hands for seven days.”
Vidil, S., Danilevicz, I. M., Dugravot, A., Fayossé, A., Landré, B., van Hees, V. T., Chen, M., Singh‐Manoux, A., & Sabia, S. (2025) · Nature Communications · doi:10.1038/s41467-025-66407-2 · Cited by 13
“We have indicated in the results section that Table S1 contains a full description of the metrics.”
Koemel, N. A., Biswas, R. K., Simpson, S. J., Rezende, L. F. M., Wang, T., Bauman, A. E., Raubenheimer, D., Allman-Farinelli, M. A., Cistulli, P. A., Ahmadi, M. N., et al. (2026) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwag141 · Cited by 12
The association of pre‐operative home accelerometry with cardiopulmonary exercise variables
Cui, H. W., Kirby, G. S., Surmacz, K., Hargrove, C., Griffiths, J., & Turney, B. W. (2017) · Anaesthesia · doi:10.1111/anae.14181 · Cited by 10
Calvin, C. M., Hagenaars, S. P., Gallacher, J., Harris, S. E., Davies, G., Liewald, D. C. M., Galé, C. R., & Deary, I. J. (2019) · Scientific Reports · doi:10.1038/s41598-018-36629-0 · Cited by 10
Physical Activity and Sedentary Behavior at the End of the Human Lifespan
Hernández‐Vicente, A., Santos‐Lozano, A., Mayolas-Pi, C., Rodríguez‐Romo, G., Pareja-Galeano, H., Bustamante, N., Gómez-Trullén, E. M., Lucía, A., & Garatachea, N. (2019) · Journal of Aging and Physical Activity · doi:10.1123/japa.2018-0122 · Cited by 11
Protocol and Data Description: The Free-Living Activity Study for Health
Hibbing, P. R., Lamoureux, N. R., Matthews, C. E., & Welk, G. J. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2020-0052 · Cited by 9
Kingsnorth, A. P., Patience, M., Moltchanova, E. V., Esliger, D., Paine, N. J., & Hobbs, M. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2021-0005 · Cited by 9
Data Contribution Summaries for Patient Engagement in Multi-Device Health Monitoring Research
Rainey, J., Verweij, D., Dodds, C. B., Graeber, J., Farhadi, F., Ali, R., Zhang, V., Bull, C., & Smeddinck, J. D. (2021) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3460418.3479371 · Cited by 8
Device-Measured Physical Activity in 3506 Individuals with Knee or Hip Arthroplasty
Small, S. R., Khalid, S., Price, A. J., & Doherty, A. (2023) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000003365 · Cited by 12
“Metrics are adjusted for age, sex, body mass index, season, Charlson Comorbidity Index, education, ethnicity, alcohol consumption, and smoking status.”
BackgroundMethodInfluentialSelf-citationZhu, J.-H., Shen, Z., Liu, B.-P., & Jia, C.-X. (2024) · Social Psychiatry and Psychiatric Epidemiology · doi:10.1007/s00127-024-02708-z · Cited by 11
Izmailova, E. S., Middleton, D., Yunis, R., Lakeland, J., Sowalsky, K. L., Kling, J., Ritchie, A., Guo, C. C., Byrom, B., & Kern, S. (2024) · Clinical and Translational Science · doi:10.1111/cts.70054 · Cited by 11
Circadian rhythms and mental health: wearable sensing at scale
Doherty, A. (2018) · The Lancet Psychiatry · doi:10.1016/s2215-0366(18)30172-x · Cited by 9
Self-citationSimon, J., Fung, K., Kolossváry, M., Sanghvi, M. M., Aung, N., Paiva, J. M., Lukaschuk, E. I., Carapella, V., Merkely, B. P., Bittencourt, M. S., et al. (2020) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeaa242 · Cited by 10
Alsharqi, M., Huckstep, O. J., Lapidaire, W., Williamson, W., Mohamed, A. B., Tan, C., Kitt, J., Burchert, H. H., Telles, F., Dawes, H., et al. (2021) · Echocardiography · doi:10.1111/echo.15149 · Cited by 9
Gasser, B. A., Boesing, M., Schoch, R., Zogg, S., Kröpfl, J. M., Thesenvitz, E., Hanssen, H., Leuppi, J. D., Schmidt‐Trucksäss, A., & Dieterle, T. (2021) · Frontiers in Physiology · doi:10.3389/fphys.2021.734111 · Cited by 13
Digital Health–Enabled Clinical Trials in Stroke: Ready for Prime Time?
Berwanger, O. B., & Machline-Carrion, M. J. (2022) · Stroke · doi:10.1161/strokeaha.122.037378 · Cited by 11
“As advoked by the Clinical Trials Transformation Initiative, by 2030, Clinical Trials (1) are patient-centered and easily accessible; (2) are fully integrated into health processes; (3) are designed with a quality-by-design and fit-for-purpose approach; and (4) maximally leverage available clinical and nonclinical dat…”
BackgroundWilletts, M., Hollowell, S., Aslett, L. J. M., Holmes, C. C., & Doherty, A. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/187625 · Cited by 12
Self-citationUniMTS: Unified Pre-training for Motion Time Series
Zhang, X., Teng, D., Chowdhury, R., Li, S., Hong, D., Gupta, R., & Shang, J. (2024) · Advances in Neural Information Processing Systems 37 · doi:10.52202/079017-3414 · Cited by 8
Oskouei, S. T., Malliaras, P., Hill, K., Clark, R. A., & Perraton, L. G. (2023) · Physiotherapy · doi:10.1016/j.physio.2023.04.001 · Cited by 8
Physical activity and the risk of periodontitis: an instrumental variable study
Baumeister, S., Reckelkamm, S. L., Ehmke, B., Nolde, M., & Baurecht, H. (2023) · Clinical Oral Investigations · doi:10.1007/s00784-023-05109-9 · Cited by 8
“For objective assessment of physical activity, a subset of 103,712 participants wore an Axivity AX3 triaxial accelerometer on the wrist for a 7-day period between 2013 and 2015 [18].”
MethodLifestyle and patterns of physical activity in Hadza foragers
Sayre, M. K., Anyawire, M., Paolo, B., Mabulla, A. Z. P., Pontzer, H., Wood, B. M., & Raichlen, D. A. (2023) · American Journal of Biological Anthropology · doi:10.1002/ajpa.24846 · Cited by 10
“We followed the accelerometry data processing and analysis methods outlined by Doherty et al. (2017).”
Influentialde Lange, M. A., Richmond, R. C., Birnie, K., Shapland, C. Y., Tilling, K. M., & Davies, N. M. (2024) · Journal of Sleep Research · doi:10.1111/jsr.14335 · Cited by 8
“In this study, participants wore Axivity AX3 triaxial accelerometers on their dominant wrist (described in detail elsewhere) (Doherty et al., 2017).”
InfluentialDuan, T., Cao, Z., Wang, X., Min, J., Sun, T., Hong, L., & Xu, C. (2024) · The British Journal of Psychiatry · doi:10.1192/bjp.2024.227 · Cited by 8
Graham, B., & Farrell, M. (2024) · Expert Systems with Applications · doi:10.1016/j.eswa.2024.126195 · Cited by 11
He, Y., Wang, J., Zhang, W., Chen, X., Wu, Q., Li, Y., Ou, Y., Liu, Y., Feng, H., Zhang, J., et al. (2025) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.13726 · Cited by 11
“The UK Biobank accelerometer expert working group calibrated the accelerometer data, while nonwear periods were identified in accordance with standard procedures [25, 26].”
Underlying biological mechanisms of emotion dysregulation in bipolar disorder
Durdurak, B. B., Morales‐Muñoz, I., de Cates, A. N., Wiseman, C. E., Broome, M. R., & Marwaha, S. (2025) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2025.1552992 · Cited by 11
Yeung, C. H. C., Wright, A. K., Windred, D. P., Burns, A. C., Phillips, A. J. K., Cain, S. W., Rutter, M. K., & Xiao, Q. (2025) · Diabetes Care · doi:10.2337/dc25-0309 · Cited by 10
Cheng, S. W. M., Biswas, R. K., Koemel, N. A., O’Sullivan, J., Sabag, A., Ahmadi, M. N., & Stamatakis, E. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf441 · Cited by 10
Resistance Exercise Therapy After COVID-19 Infection: A Randomized Clinical Trial
Berry, C., McKinley, G., Bayes, H. K., Anderson, D., Lang, C. C., Gill, A., Morrow, A., Sykes, R., Taggart, D., Kamdar, A. L., et al. (2025) · JAMA Network Open · doi:10.1001/jamanetworkopen.2025.34304 · Cited by 11
Tran, D. T., Strohmaier, S., Żebrowska, M., Huang, T., Papantoniou, K., Redline, S. S., Saxena, R., Rutter, M. K., & Schernhammer, E. S. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf774 · Cited by 12
Associations of novel 24-h accelerometer-derived metrics with adiposity in children and adolescents
Dygrýn, J., Medrano, M., Molina‐García, P., Rubín, L., Jakubec, L., Janda, D., & Gába, A. (2021) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-021-00987-5 · Cited by 9
“, lower price, increasing battery capacity, and memory size), such types of accelerometers are gaining popularity even in large-sample studies under free-living conditions [11, 15].”
BackgroundScheithauer, M. C., Hiremath, S. K., Southerland, A., Rozga, A., Plötz, T., Rock, C., & Call, N. A. (2022) · Research in Autism · doi:10.1016/j.rasd.2022.102043 · Cited by 8
“It is likely that wear time based on the accelerometry data is more accurate than caregiver report given our data analysis procedures are based on a very large-scale study with validated procedures (Doherty et al., 2017).”
InfluentialSelf-citationWrist-Worn Accelerometry, Aging, and Gait Speed in the Baltimore Longitudinal Study of Aging
Wanigatunga, A. A., Liu, F., Urbanek, J. K., Wang, H., Di, J., Zipunnikov, V., Cai, Y., Dougherty, R. J., Simonsick, E. M., Ferrucci, L., et al. (2022) · Journal of Aging and Physical Activity · doi:10.1123/japa.2022-0156 · Cited by 10
Herteleer, M., Runer, A., Remppis, M., Brouwers, J., Schneider, F., Panagiotopoulou, V. C., Grimm, B. P., Hengg, C., Arora, R. R., Nijs, S., et al. (2023) · Bioengineering · doi:10.3390/bioengineering10020128 · Cited by 8
“81 m/s2 acceleration) in each direction, and the orientation of the measured vector is perpendicular to the planar sides of the sensor’s housing when resting on a horizontal flat surface [24].”
BackgroundRowlands, A. V., van Hees, V. T., Dawkins, N. P., Maylor, B. D., Plekhanova, T., Henson, J. J., Edwardson, C. L., Brady, E. M., Hall, A. P., Davies, M. J., et al. (2023) · Sensors · doi:10.3390/s23125382 · Cited by 10
“Accelerometers are commonly worn 24 h a day to assess movement behaviors, with the average acceleration over the 24 h day often being used as the primary indicator of the physical activity level [8,9].”
BackgroundMethodLin, F., Shi, Y., Song, W., Weng, Y., Zou, X., Chen, X., Zheng, J., Chen, K., Ye, Q., Wu, X., et al. (2024) · BMC Medicine · doi:10.1186/s12916-024-03497-7 · Cited by 9
“” Accelerometer data were preprocessed using standard procedures, including device calibration, resampling to 100 Hz, and removal of noise and gravity [17].”
Method
Metadata
- Authors
- Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., Preece, S. J., Gillions, R., Sheard, S., Peakman, T., Brage, S., & Wareham, N. J.
- Affiliations
- University of Oxford (GB)
- Newcastle University (GB)
- University of Salford (GB)
- University of Cambridge (GB)
- UK Biobank (GB)
- Corresponding author
- Doherty, Aiden
- ORCID
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-02-01
- Volume
- 12
- Issue
- 2
- Pages
- e0169649
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5287488
- OpenAlex
- W2584016859
- Cited by
- 1,250
- References
- 22
- Citations by year
- 2026: 180 · 2025: 210 · 2024: 179 · 2023: 142 · 2022: 110 · 2021: 148 · 2020: 108 · 2019: 87 · 2018: 66 · 2017: 20
- FWCI
- 56.84
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Apollo (cc-by)
- Funders
- Wellcome Trust
- Medical Research Council (MC_UU_12015/1, MC_UU_12015/3)
- British Heart Foundation (GB) (RE/13/1/30181)
- Li Ka Shing Foundation (HK)
- Research Councils UK (GB) (EP/G066019/1)
- Engineering and Physical Sciences Research Council (EP/L016176/1)
- National Institute for Health Research (SRF-2011-04-017)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- physical activity, wrist-worn accelerometers, objective physical activity measurement, UK Biobank, age differences in physical activity, sex differences in physical activity, diurnal variation, seasonal variation, vector magnitude, triaxial acceleration
- MeSH terms
- Aged, Female, United Kingdom, Humans, Male, Middle Aged, Seasons, Time Factors, Wrist Joint, Exercise, Biological Specimen Banks, Accelerometry, Public Health Surveillance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.