Robust blind spectral unmixing for fluorescence microscopy using unsupervised learning
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Due to the overlapping emission spectra of fluorophores, fluorescence microscopy images often have bleed-through problems, leading to a false positive detection. This problem is almost unavoidable when the samples are labeled with three or more fluorophores, and the situation is complicated even further when imaged under a multiphoton microscope. Several methods have been developed and commonly used by biologists for fluorescence microscopy spectral unmixing, such as linear unmixing, non-negative matrix factorization, deconvolution, and principal component analysis. However, they either require pre-knowledge of emission spectra or restrict the number of fluorophores to be the same as detection channels, which highly limits the real-world applications of those spectral unmixing methods. In this paper, we developed a robust and flexible spectral unmixing method: Learning Unsupervised Means of Spectra (LUMoS), which uses an unsupervised machine learning clustering method to learn individual fluorophores' spectral signatures from mixed images, and blindly separate channels without restrictions on the number of fluorophores that can be imaged. This method highly expands the hardware capability of two-photon microscopy to simultaneously image more fluorophores than is possible with instrumentation alone. Experimental and simulated results demonstrated the robustness of LUMoS in multi-channel separations of two-photon microscopy images. We also extended the application of this method to background/autofluorescence removal and colocalization analysis. Lastly, we integrated this tool into ImageJ to offer an easy to use spectral unmixing tool for fluorescence imaging. LUMoS allows us to gain a higher spectral resolution and obtain a cleaner image without the need to upgrade the imaging hardware capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · doi:10.5555/1283383.1283494 · Cited by 7,364
Keshava, N., & Mustard, J. F. (2002) · IEEE Signal Processing Magazine · doi:10.1109/79.974727 · Cited by 2,549 · cited 5×
“Third, remote sensing images have hundreds of spectral bands which is usually much more than the number of endmembers, making linear algebra based unmixing methods, such as linear unmixing, NMF, and deconvolution, better suited [38,63,64].”
BackgroundInfluentialXu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198 · cited 1×
“Adapting 2PLSM for simultaneous multi-fluorophore detection has presented a challenge due to 37 the widely overlapping two-photon absorption spectra of commonly used fluorescent markers [6-8] as well as the 38 high expense of incorporating multiple two-photon laser lines.”
MethodPrinciples of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027 · cited 1×
“live animals with deeper tissue penetrations, 3D contrast and resolution, and reduced phototoxicity [1,2].”
BackgroundCell and tissue autofluorescence research and diagnostic applications
Monici, M. (2005) · Biotechnology Annual Review · doi:10.1016/s1387-2656(05)11007-2 · Cited by 887 · cited 1×
“Autofluorescence can come from some extracellular components or some cell types [44].”
BackgroundTwo-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Spectral Imaging and Linear Unmixing in Light Microscopy
Zimmermann, T. (2005) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/b102216 · Cited by 302 · cited 6×
“7 and b = 100 to reflect the tendency of a fluorochrome to have a long tail at the longer wavelength [37].”
BackgroundMethodInfluentialClearing Up the Signal: Spectral Imaging and Linear Unmixing in Fluorescence Microscopy
Zimmermann, T., Marrison, J., Hogg, K., & O’Toole, P. (2014) · Methods in Molecular Biology · doi:10.1007/978-1-60761-847-8_5 · Cited by 102 · cited 2×
“Unlike linear unmixing [10,18], one of the major assumptions of the LUMoS algorithm is that one pixel is 352 uniquely labeled with one fluorophore, which is advantageous in the way that it provides unambiguous results 353 especially in biological imaging (examples in Figs 3-5).”
BackgroundSix-color intravital two-photon imaging of brain tumors and their dynamic microenvironment
Ricard, C., & Debarbieux, F. C. (2014) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2014.00057 · Cited by 75 · cited 4×
“Combining 484 two or more fluorescent probes offers significantly a higher level of information [25,53,54], but may also lead to 485”
BackgroundMethodInfluential
Cited by
Multiplex Immunohistochemistry and Immunofluorescence: A Practical Update for Pathologists
Harms, P. W., Frankel, T. L., Moutafi, M., Rao, A., Rimm, D. L., Taube, J. M., Thomas, D., Chan, M. P., & Pantanowitz, L. (2023) · Modern Pathology · doi:10.1016/j.modpat.2023.100197 · Cited by 177
Lin, J.-R., Chen, Y.-A., Campton, D., Cooper, J., Coy, S., Yapp, C., Tefft, J. B., McCarty, E., Ligon, K. L., Rodig, S. J., et al. (2023) · Nature Cancer · doi:10.1038/s43018-023-00576-1 · Cited by 165
“This can be overcome using tuned emission and excitation filters and spectral deconvolution (e.g., of 6 to 10 channels) 25 or by dispersing emitted light using a diffraction grating and then performing linear unmixing 26,27 .”
Blind Hyperspectral Unmixing Using Autoencoders: A Critical Comparison
Palsson, B., Sveinsson, J. R., & Ulfarsson, M. O. (2022) · IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing · doi:10.1109/jstars.2021.3140154 · Cited by 107
Live-cell imaging powered by computation
Shroff, H., Testa, I., Jug, F., & Manley, S. (2024) · Nature Reviews Molecular Cell Biology · doi:10.1038/s41580-024-00702-6 · Cited by 75
“We note that these methods make no assumptions about the sample structure but have tradeoffs — the greater the resolution gain, the higher the cost in SNR, phototoxicity or temporal resolution — making some better suited for live imaging than others 53 .”
Second Near‐Infrared Window Fluorescence Materials for In Vivo Dynamic Multiplexed Imaging
Fan, F., Zeng, K., Zhu, Y., Zhang, Y., Chen, Y., Lv, D., Jia, D., Chai, Y., Chen, X., & Li, Q. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202422693 · Cited by 33
Layer-specific input to medial prefrontal cortex is linked to stress susceptibility
Solakoğlu, S. T., Erdener, Ş. E., Gliko, O., Can, A., Sümbül, U., & Eren-Koçak, E. (2025) · Translational Psychiatry · doi:10.1038/s41398-025-03258-x · Cited by 5
“1) [34].”
Metadata
- Authors
- McRae, T. D., Oleksyn, D., Miller, J., & Gao, Y.-R.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2019-12-02
- Volume
- 14
- Issue
- 12
- Pages
- e0225410
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2992361169
- Cited by
- 77
- References
- 9
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.