CoChat

Demonstration of the potential of white-box machine learning approaches to gain insights from cardiovascular disease electrocardiograms

Open access

The DOI matches its Crossref record; 59 of the 60 references it cites were found in a registry or an index, and 1 are not checked yet.

Abstract

We present the results from a white-box machine learning approach to detect cardiac arrhythmias using electrocardiographic data. A C5.0 is trained to recognize four classes using common features. The four classes are (i) atrial fibrillation and atrial flutter, (ii) tachycardias (iii), sinus bradycardia and (iv) sinus rhythm. Data from 10,646 subjects, 83% of whom have at least one arrhythmia and 17% of whom exhibit a normal sinus rhythm, are used. The C5.0 is trained using 10-fold cross-validation and is able to achieve a balanced accuracy of 95.35%. By using the white-box machine learning approach, a clear and comprehensible tree structure can be revealed, which has selected the 5 most important features from a total of 24 features. These 5 features are ventricular rate, RR-Interval variation, atrial rate, age and difference between longest and shortest RR-Interval. The combination of ventricular rate, RR-Interval variation and atrial rate is especially relevant to achieve classification accuracy, which can be disclosed through the tree. The tree assigns unique values to distinguish the classes. These findings could be applied in medicine in the future. It can be shown that a white-box machine learning approach can reveal granular structures, thus confirming known linear relationships and also revealing nonlinear relationships. To highlight the strength of the C5.0 with respect to this structural revelation, the results of further white-box machine learning and black-box machine learning algorithms are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0243615

Cites

59 of 60 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Schematic comparison of white-box and black-box ML approaches.
Fig 1 Schematic comparison of white-box and black-box ML approaches.CC BY · PubMed Central
Fig 2 C5.0 in the scope of scientific theory.
Fig 2 C5.0 in the scope of scientific theory.CC BY · PubMed Central
Fig 3 Decision tree from C5.0 model.
Fig 3 Decision tree from C5.0 model.CC BY · PubMed Central
Fig 4 Schematic ECG waveform of a normal cardiac cycle.
Fig 4 Schematic ECG waveform of a normal cardiac cycle.CC BY · PubMed Central
Fig 5 ECG of the 4 classes. Atrial fibrillation as one example of class 0; sinus tachycardia as an example of class 1; class 2 is shown with an exemplary sinus bradycardia signal; a sinus rhythm represents class 3.
Fig 5 ECG of the 4 classes. Atrial fibrillation as one example of class 0; sinus tachycardia as an example of class 1; class 2 is shown with an exemplary sinus bradycardia signal; a sinus rhythm represents class 3.CC BY · PubMed Central
Fig 6 Boxplot for the RR-Interval variation of classes 0, 1 and 3.
Fig 6 Boxplot for the RR-Interval variation of classes 0, 1 and 3.CC BY · PubMed Central
Fig 7 Decision paths of the C5.0 model. Paths to class 0 are shown in cyan, to class 1 in yellow, to class 2 in green and to class 3 in orange. Paths for multiple classes are shown in black dashed lines.
Fig 7 Decision paths of the C5.0 model. Paths to class 0 are shown in cyan, to class 1 in yellow, to class 2 in green and to class 3 in orange. Paths for multiple classes are shown in black dashed lines.CC BY · PubMed Central
Fig 8 Visualization of the two best features of k-NN and Naive Bayes Classifier. For clarity, only 1,000 randomly selected patients were included in the visualization.
Fig 8 Visualization of the two best features of k-NN and Naive Bayes Classifier. For clarity, only 1,000 randomly selected patients were included in the visualization.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 34

Metadata

Authors
Rieg, T., Frick, J., Baumgartl, H., & Buettner, R.
Affiliations
Hochschule Aalen (DE)
Corresponding author
Rieg, Thilo
Venue
PLOS ONE
Published
2020-12-17
Volume
15
Issue
12
Pages
e0243615
ISSN
1932-6203 (ISSN-L)
OpenAlex
W3112230406
Cited by
34
References
59
Citations by year
2026: 1 · 2025: 5 · 2024: 9 · 2023: 9 · 2022: 5 · 2021: 5
FWCI
2.94
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • OPUS (Aalen University) (submittedVersion)
Funders
  • Carl-Zeiss-Stiftung
  • Bundesministerium für Bildung und Forschung
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
arrhythmia detection, electrocardiogram, C5.0 decision tree, atrial fibrillation, atrial flutter, tachycardia, sinus bradycardia, ventricular rate, atrial rate, feature selection, cardiovascular disease
MeSH terms
Machine Learning, Adult, Aged, Aged, 80 and over, Algorithms, Arrhythmias, Cardiac, Electrocardiography, Female, Humans, Male, Middle Aged

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.