Demonstration of the potential of white-box machine learning approaches to gain insights from cardiovascular disease electrocardiograms
Open accessThe DOI matches its Crossref record; 59 of the 60 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
We present the results from a white-box machine learning approach to detect cardiac arrhythmias using electrocardiographic data. A C5.0 is trained to recognize four classes using common features. The four classes are (i) atrial fibrillation and atrial flutter, (ii) tachycardias (iii), sinus bradycardia and (iv) sinus rhythm. Data from 10,646 subjects, 83% of whom have at least one arrhythmia and 17% of whom exhibit a normal sinus rhythm, are used. The C5.0 is trained using 10-fold cross-validation and is able to achieve a balanced accuracy of 95.35%. By using the white-box machine learning approach, a clear and comprehensible tree structure can be revealed, which has selected the 5 most important features from a total of 24 features. These 5 features are ventricular rate, RR-Interval variation, atrial rate, age and difference between longest and shortest RR-Interval. The combination of ventricular rate, RR-Interval variation and atrial rate is especially relevant to achieve classification accuracy, which can be disclosed through the tree. The tree assigns unique values to distinguish the classes. These findings could be applied in medicine in the future. It can be shown that a white-box machine learning approach can reveal granular structures, thus confirming known linear relationships and also revealing nonlinear relationships. To highlight the strength of the C5.0 with respect to this structural revelation, the results of further white-box machine learning and black-box machine learning algorithms are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures








Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other methods are gradient based, like saliency maps,68 and calculate the contribution of each input pixel to the overall classification performance.”
From Addressing bias in big data and AI for health care: A call for open science (2021) · cites this paper as [68]
In the citing paper
“As an example, transparent techniques like decision trees, relying on interpretable features, can provide a “white-box” approach for diagnosis.68”
From Addressing bias in big data and AI for health care: A call for open science (2021) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rudin, C. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0048-x · Cited by 10,561 · cited 4×
“A wrong decision in medicine can have serious consequences for the patient; therefore, high transparency and interpretability in the decision making process are important [6].”
BackgroundInfluentialGulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · Europace · doi:10.1093/europace/euw295 · Cited by 6,439
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148 · cited 1×
“The detection of cardiovascular diseases is extremely complex in everyday clinical practice [1].”
Background2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Definitions, methods, and applications in interpretable machine learning
Murdoch, W. J., Singh, C., Kumbier, K., Abbasi-Asl, R., & Yu, B. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1900654116 · Cited by 2,167 · cited 1×
“Stability is of high relevance for ML models, especially for white-box ML models, where reliable information is to be obtained directly from the models [56].”
BackgroundNew ideas about atrial fibrillation 50 years on
Nattel, S. (2002) · Nature · doi:10.1038/415219a · Cited by 1,481 · cited 1×
“Class 0 can also lead to significantly increased heartbeat [16, 42].”
Background2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403 · cited 2×
“Together with the fact that class 0 is well detected, this can be seen as a further confirmation of the suitability of the rules used in practice and science [16, 17].”
BackgroundThe Logic of Scientific Discovery
Popper, K. (2005) · Routledge eBooks · doi:10.4324/9780203994627 · Cited by 1,142
Deep learning algorithms for detection of critical findings in head CT scans: a retrospective study
Chilamkurthy, S., Ghosh, R., Tanamala, S., Biviji, M., Campeau, N. G., Venugopal, V. K., Mahajan, V., Rao, P., & Warier, P. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31645-3 · Cited by 1,020
Decision trees: An overview and their use in medicine
Podgorelec, V., Kokol, P., Stiglic, B., & Rozman, I. (2002) · Journal of Medical Systems · doi:10.1023/a:1016409317640 · Cited by 736 · cited 2×
“0 offers a more common structure for the interpretation of the results [31, 32].”
BackgroundMethodJanuary, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.021 · Cited by 576
Loyola-Gonzalez, O. (2019) · IEEE Access · doi:10.1109/access.2019.2949286 · Cited by 559 · cited 1×
“On the contrary, white-box ML approaches are characterized by the fact that the structure with which an algorithm produces a result can be revealed, and therefore, they can easily be understood by experts in the field [8].”
BackgroundA 12-lead electrocardiogram database for arrhythmia research covering more than 10,000 patients
Zheng, J., Zhang, J., Danioko, S., Yao, H., Guo, H., & Rakovski, C. (2020) · Scientific Data · doi:10.1038/s41597-020-0386-x · Cited by 487
Computer-Interpreted Electrocardiograms
Schläpfer, J., & Wellens, H. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.723 · Cited by 377 · cited 1×
“However, various studies indicate substantial misdiagnosis [11, 12].”
Methodological issues in the quantification of respiratory sinus arrhythmia.
Denver, J. W., Reed, S. F., & Porges, S. W. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2005.09.005 · Cited by 333 · cited 1×
“Sinus irregularities are mostly naturally occurring and benign rhythms, which also occur in a healthy state, especially in young people [19, 20].”
BackgroundConjectures and Refutations: The Growth of Scientific Knowledge
Popper, K. (2014) · doi:10.4324/9780203538074 · Cited by 327
Tateno, K., & Glass, L. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02345439 · Cited by 295 · cited 1×
“HRV Mean (ms) Mean value of RR-Intervals; see [21, 23] RR-Interval variation (%) Standard deviation divided by mean of RR-Intervals; see [24, 25]”
BackgroundThe Evaluation and Management of Bradycardia
Mangrum, J. M., & DiMarco, J. P. (2000) · New England Journal of Medicine · doi:10.1056/nejm200003093421006 · Cited by 279
Effect of Age and Sex on Heart Rate Variability in Healthy Subjects
Zhang, J. (2007) · Journal of Manipulative and Physiological Therapeutics · doi:10.1016/j.jmpt.2007.04.001 · Cited by 276 · cited 1×
“This is due to the fact that the variation in heartbeat decreases with age, and a higher RR-Interval variation is therefore not unusual for younger people [52].”
BackgroundIlluminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274 · cited 2×
“As a result of the exposed and comprehensible knowledge, the discourse in the domain can be enriched and the trust of domain experts can be increased [7].”
BackgroundDevelopment of machine learning models for diagnosis of glaucoma
Kim, S. J., Cho, K. J., & Oh, S. (2017) · PLOS ONE · doi:10.1371/journal.pone.0177726 · Cited by 266 · cited 1×
“0 algorithm as a classification model for the 4 classes because of its good interpretability and structure-revealing characteristics [9, 30], which are particularly suitable for this work.”
MethodBig data and black-box medical algorithms
Price, W. N. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aao5333 · Cited by 254 · cited 2×
“However, as can also be seen in Fig 1, they are difficult or impossible to understand [5].”
BackgroundMcManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253 · cited 4×
“Feature (Unit) Description RMSSD (ms) Root mean square of Successive Differences; see [21, 22, 27]”
BackgroundInfluentialLyon, A., Mincholé, A., Martínez, J. P., Laguna, P., & Rodriguez, B. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0821 · Cited by 228 · cited 1×
“These diseases are responsible for 30% of deaths [10].”
BackgroundC5. 0 Algorithm to Improved Decision Tree with Feature Selection and Reduced Error Pruning
Pandya, R., & Pandya, J. (2015) · International Journal of Computer Applications · doi:10.5120/20639-3318 · Cited by 223
Cardiac arrhythmia classification using statistical and mixture modeling features of ECG signals
Ghorbani Afkhami, R., Azarnia, G., & Tinati, M. A. (2016) · Pattern Recognition Letters · doi:10.1016/j.patrec.2015.11.018 · Cited by 208 · cited 1×
“Mean (mV) Mean of the ECG signal Skewness Skewness of the ECG signal; see [26] Kurtosis Kurtosis of the ECG signal; see [26] SDNN (ms) Standard deviation of normal RR-Intervals; see [22] Sex Gender of the subject Age (Years) Age of the subject Ventricular rate (BPM) Calculated through time between R-peaks Atrial rate…”
2015 ACC/AHA/HRS guideline for the management of adult patients with supraventricular tachycardia
Page, R. L., Joglar, J. A., Caldwell, M. A., Calkins, H., Conti, J. B., Deal, B. J., Estes III, N. A. M., Field, M. E., Goldberger, Z. D., Hammill, S. C., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.019 · Cited by 206 · cited 2×
“As far as the grouping of classes is concerned, the individual diseases were combined into four classes according to the guidelines [16–18].”
BackgroundMethodRecent advances in understanding sex differences in cardiac repolarization
James, A. F., Choisy, S. C. M., & Hancox, J. C. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2005.05.010 · Cited by 202 · cited 4×
“This corresponds to the number of P-waves per minute.”
BackgroundInfluentialAlcaraz, R., & Rieta, J. J. (2010) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2009.11.001 · Cited by 194 · cited 2×
“Feature (Unit) Description RMSSD (ms) Root mean square of Successive Differences; see [21, 22, 27]”
BackgroundMechanism of ”inappropriate” sinus tachycardia. Role of sympathovagal balance
Morillo, C. A., Klein, G. J., Thakur, R. K., Li, H., Zardini, M., & Yee, R. (1994) · Circulation · doi:10.1161/01.cir.90.2.873 · Cited by 193
Inappropriate sinus tachycardia
Olshansky, B., & Sullivan, R. M. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.07.074 · Cited by 182 · cited 1×
“While a normal heart rate is between 60 BPM—100 BPM, class 1 diseases lead to heartbeats of over 100 BPM [45].”
BackgroundECG arrhythmia classification based on optimum-path forest
Luz, E. J. D. S., Nunes, T. M., de Albuquerque, V. H. C., Papa, J. P., & Menotti, D. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.12.063 · Cited by 177 · cited 2×
“Mean (mV) Mean of the ECG signal Skewness Skewness of the ECG signal; see [26] Kurtosis Kurtosis of the ECG signal; see [26] SDNN (ms) Standard deviation of normal RR-Intervals; see [22] Sex Gender of the subject Age (Years) Age of the subject Ventricular rate (BPM) Calculated through time between R-peaks Atrial rate…”
BackgroundMethodECG Signal Classification Using Various Machine Learning Techniques
Celin, S., & Vasanth, K. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-1083-6 · Cited by 167
A hierarchical method based on weighted extreme gradient boosting in ECG heartbeat classification
Shi, H., Wang, H., Huang, Y., Zhao, L., Qin, C., & Liu, C. (2019) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2019.02.005 · Cited by 162
Ben‐Tal, A., Shamailov, S. S., & Paton, J. F. R. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.222422 · Cited by 161 · cited 1×
“Sinus irregularities are mostly naturally occurring and benign rhythms, which also occur in a healthy state, especially in young people [19, 20].”
Backgroundk-Nearest neighbor models for microarray gene expression analysis and clinical outcome prediction
Parry, R. M., Jones, W. D., Stokes, T. H., Phan, J. H., Moffitt, A. B., Fang, H., Shi, L. M., Oberthuer, A., Fischer, M., Tong, W., et al. (2010) · The Pharmacogenomics Journal · doi:10.1038/tpj.2010.56 · Cited by 154
Delineation of ECG characteristic features using multiresolution wavelet analysis method
Banerjee, S., Gupta, R., & Mitra, M. (2011) · Measurement · doi:10.1016/j.measurement.2011.10.025 · Cited by 151 · cited 1×
“Mean (mV) Mean of the ECG signal Skewness Skewness of the ECG signal; see [26] Kurtosis Kurtosis of the ECG signal; see [26] SDNN (ms) Standard deviation of normal RR-Intervals; see [22] Sex Gender of the subject Age (Years) Age of the subject Ventricular rate (BPM) Calculated through time between R-peaks Atrial rate…”
Errors in the computerized electrocardiogram interpretation of cardiac rhythm
Shah, A. P., & Rubin, S. A. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.03.008 · Cited by 129 · cited 1×
“However, various studies indicate substantial misdiagnosis [11, 12].”
Heart Rate Variability in Patients With Atrial Fibrillation Is Related to Vagal Tone
van den Berg, M. P., Haaksma, J., Brouwer, J., Tieleman, R. G., Mulder, G., & Crijns, H. J. G. M. (1997) · Circulation · doi:10.1161/01.cir.96.4.1209 · Cited by 119
Valdes, G., Luna, J. M., Eaton, E., Simone, C. B., Ungar, L. H., & Solberg, T. D. (2016) · Scientific Reports · doi:10.1038/srep37854 · Cited by 118
Classification of ECG heartbeats using nonlinear decomposition methods and support vector machine
Rajesh, K. N. V. P. S., & Dhuli, R. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.06.006 · Cited by 118 · cited 1×
“HRV Mean (ms) Mean value of RR-Intervals; see [21, 23] RR-Interval variation (%) Standard deviation divided by mean of RR-Intervals; see [24, 25]”
BackgroundPrediction of Ventricular Tachycardia One Hour before Occurrence Using Artificial Neural Networks
Lee, H., Shin, S.-Y., Seo, M., Nam, G.-B., & Joo, S. (2016) · Scientific Reports · doi:10.1038/srep32390 · Cited by 114 · cited 1×
“chambers between the heartbeats to fill incompletely with blood [48].”
BackgroundABC of clinical electrocardiography: Atrial arrhythmias
Goodacre, S. W. (2002) · BMJ · doi:10.1136/bmj.324.7337.594 · Cited by 49
ECG-based pulse detection during cardiac arrest using random forest classifier
Elola, A., Aramendi, E., Irusta, U., Ser, J. D., Alonso, E., & Daya, M. R. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1892-2 · Cited by 44
Heart rate variability in inappropriate sinus tachycardia
Castellanos, A., Moleiro, F., Chakko, S., Acosta, H., Huikuri, H., Mitrani, R. D., & Myerburg, R. J. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00373-7 · Cited by 41 · cited 1×
“Regarding the variability of the heartbeat, there are findings that it is reduced in subjects with tachycardia [55].”
BackgroundHennig, T., Maass, P., Hayano, J., & Heinrichs, S. (2006) · Journal of Biological Physics · doi:10.1007/s10867-006-9022-z · Cited by 41 · cited 2×
“Patients with atrial fibrillation have greater variation in their heartbeats than class 3 subjects [43, 51].”
BackgroundT-wave axis deviation as an independent predictor of mortality in chronic Chagas' disease
Salles, G. F., Xavier, S. S., de Sousa, A. S., Hasslocher‐Moreno, A. M., & Cardoso, C. R. L. (2004) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.01.040 · Cited by 41 · cited 1×
“Mean (mV) Mean of the ECG signal Skewness Skewness of the ECG signal; see [26] Kurtosis Kurtosis of the ECG signal; see [26] SDNN (ms) Standard deviation of normal RR-Intervals; see [22] Sex Gender of the subject Age (Years) Age of the subject Ventricular rate (BPM) Calculated through time between R-peaks Atrial rate…”
McLachlan, C. S., Ocsan, R. J., Spence, I., Hambly, B. D., Matthews, S. T., Wang, L., & Jelinek, H. F. (2010) · Baylor University Medical Center Proceedings · doi:10.1080/08998280.2010.11928655 · Cited by 36 · cited 2×
“HRV Mean 2 [57] not verified RMSSD 0 [27] not verified Nonlinear combination of ventricular rate, RR-Interval variation and age 0 and 3 new knowledge”
BackgroundThe human atrial pacemaker complex
Boineau, J. P., Schuessler, R. B., Canavan, T. E., Corr, P. B., CAIN, M. E., & Cox, J. L. (1990) · Journal of Electrocardiology · doi:10.1016/s0022-0736(07)80122-1 · Cited by 34 · cited 1×
“In class 1 diseases, an electrical impulse fires outside the sinus node [46, 47] and thus leads to a significantly increased heartbeat, shortened RR-Intervals and increased ventricular rate.”
BackgroundSrinivasan, N. T., Orini, M., Providencia, R. A., Simón, R., LOWE, M. D., Segal, O. R., CHOW, A. W. C., SCHILLING, R. J., Hunter, R. J., Taggart, P. I., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.12.006 · Cited by 34 · cited 1×
“This is followed by the T-wave as an expression of repolarization [40].”
BackgroundRisk Factors for Bradycardia Requiring Pacemaker Implantation in Patients With Atrial Fibrillation
Barrett, T. W., Abraham, R. L., Jenkins, C. A., Russ, S. E., Storrow, A. B., & Darbar, D. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.06.037 · Cited by 29 · cited 1×
“However, it should be noted that bradycardia in connection with atrial fibrillation is also not uncommon [43, 44].”
BackgroundChristov, I. I., Krasteva, V., Simova, I. I., Neycheva, T., & Schmid, R. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aad9f0 · Cited by 29 · cited 2×
“Feature (Unit) Description RMSSD (ms) Root mean square of Successive Differences; see [21, 22, 27]”
BackgroundVentricular rate and beat-to-beat variation of stroke volume in atrial fibrillation
Kerr, A., Williams, M. J. A., & Stewart, R. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01475-8 · Cited by 25 · cited 1×
“Due to the variation in the ventricular rate in class 0, there is a higher signal variance [50], which is reflected in node 19.”
BackgroundAppearance of Atrial Rhythm with Absent P Wave in Longstanding Atrial Fibrillation
Friedman, H. S., Gomes, J. A., TARDIO, A. R., Levites, R., & Haft, J. I. (1974) · CHEST Journal · doi:10.1378/chest.66.2.172 · Cited by 16 · cited 1×
“Node 12 again uses the atrial rate for class 0, which is due to the fact that the P-wave is absent, which can occur in atrial fibrillation [53].”
BackgroundThe nature of P-wave dispersion — A clinically useful parameter that does not exist
Zimmer, K., Przywara, W., Zyśko, D., Sławuta, A., & Gajek, J. J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.03.031 · Cited by 16 · cited 2×
“The depolarization of the atria can be recognized by the P-wave [38, 39], and the depolarization of the ventricles can be determined by the QRS-Complex [39].”
BackgroundChen, B. K., Le, H., Rhodes, C., & Che, D. (2016) · Lecture notes in computer science · doi:10.1007/978-3-319-41561-1_18 · Cited by 10
Yan, D., Xu, X.-R., Qian, Y., Peng, H., Qian, H., Yue, B.-W., Zhao, L., Zhang, Z., & Fang, Z. (2019) · Medicine · doi:10.1097/md.0000000000015536 · Cited by 7
Cited by
Ali, S., Abuhmed, T., El-Sappagh, S., Muhammad, K., Alonso-Moral, J. M., Confalonieri, R., Guidotti, R., Del Ser, J., Díaz-Rodríguez, N., & Herrera, F. (2023) · Information Fusion · doi:10.1016/j.inffus.2023.101805 · Cited by 1,762
Addressing bias in big data and AI for health care: A call for open science
Norori, N., Hu, Q., Aellen, F. M., Faraci, F. D., & Tzovara, A. (2021) · Patterns · doi:10.1016/j.patter.2021.100347 · Cited by 903
“niques like decision trees, relying on interpretable features, can provide a ‘‘white-box’’ approach for diagnosis.(68) The field of computer vision has dedicated a substantial effort in obtaining interpretable features and understanding the process of classification.”
BackgroundA Comprehensive Survey on Artificial Intelligence Empowered Edge Computing on Consumer Electronics
Syu, J.-H., Lin, J. C.-W., Srivastava, G., & Yu, K. (2023) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2023.3318150 · Cited by 212
“XAI refers to understandable and transparent explanations of the AI decision-making process [52], and can further verify existing knowledge, challenge existing knowledge, and generate new knowledge [53].”
BackgroundAlugubelli, N. R., Abuissa, H. S., & Róka, A. (2022) · Sensors · doi:10.3390/s22228903 · Cited by 172
Explainable AI decision model for ECG data of cardiac disorders
Anand, A., Kadian, T., Shetty, M. K., & Gupta, A. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103584 · Cited by 154
Metadata
- Authors
- Rieg, T., Frick, J., Baumgartl, H., & Buettner, R.
- Affiliations
- Hochschule Aalen (DE)
- Corresponding author
- Rieg, Thilo
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-12-17
- Volume
- 15
- Issue
- 12
- Pages
- e0243615
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC7746264
- OpenAlex
- W3112230406
- Cited by
- 34
- References
- 59
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 9 · 2023: 9 · 2022: 5 · 2021: 5
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- OPUS (Aalen University) (submittedVersion)
- Funders
- Carl-Zeiss-Stiftung
- Bundesministerium für Bildung und Forschung
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Health Professions › Health Information Management › Artificial Intelligence in Healthcare
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- arrhythmia detection, electrocardiogram, C5.0 decision tree, atrial fibrillation, atrial flutter, tachycardia, sinus bradycardia, ventricular rate, atrial rate, feature selection, cardiovascular disease
- MeSH terms
- Machine Learning, Adult, Aged, Aged, 80 and over, Algorithms, Arrhythmias, Cardiac, Electrocardiography, Female, Humans, Male, Middle Aged
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.