Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 272

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

High-Sensitivity Enzyme Immunoassay for C-Reactive Protein in Dried Blood Spots

McDade, Thomas W, Burhop, James, Dohnal, James · 2004 · Clinical Chemistry

Abstract

C-Reactive protein (CRP), the prototypical acute-phase protein, is produced by liver hepatocytes and regulated by cytokines, particularly interleukin-6 (1)(2). Circulating concentrations of CRP indicate inflammatory activity, and the recent development of highly sensitive CRP assays (3)(4)(5) has led to the discovery that slight increases in CRP (>1–2 mg/L) are indicative of low-grade inflammatory processes that may be related to the pathophysiology of cardiovascular disease. More than a dozen population-based studies have demonstrated that increased CRP is an independent risk factor for future cardiovascular disease, with adjusted odds ratios >2.0 (6)(7)(8)(9). The American Heart Association and the CDC have recommended measurements of CRP in clinical practice and called for additional population-based research (10). A potential obstacle to the measurement of CRP (as well as other biomarkers) in large epidemiologic, community-based studies is the requirement for venous blood. Venipuncture is a relatively invasive procedure that must be performed by a trained phlebotomist (usually in a clinical setting), and it requires readily accessible facilities where blood samples can be promptly processed and stored under controlled conditions. Assays using whole blood dried on filter paper may provide a viable alternative: Several community-based applications have shown this to be a convenient and reliable means to facilitate sample collection, storage, and transportation, and laboratory methods have been validated for a growing number of analytes (11)(12)(13)(14)(15)(16). “Guthrie papers” have been a core component of US hospital-based newborn-screening programs since the 1960s and are subject to a rigorous quality-control program (17). Samples can be collected on filter paper easily by nonmedical personnel: The patient’s finger is pricked with a sterile, disposable lancet (commonly used by diabetics), and up to five drops of blood (∼50 …

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2003.029488

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 272

Metadata

Authors
McDade, T. W., Burhop, J., & Dohnal, J.
Venue
Clinical Chemistry
Published
2004-03-01
Volume
50
Issue
3
Pages
652-654
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2159820823
Cited by
272
References
18
FWCI
2.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Sensitivity Enzyme Immunoassay for C-Reactive Protein in Dried Blood Spots. https://app.cochat.ai/papers/10.1373/clinchem.2003.029488
The paper
McDade, T. W., Burhop, J., & Dohnal, J. (2004). High-Sensitivity Enzyme Immunoassay for C-Reactive Protein in Dried Blood Spots. Clinical Chemistry. https://doi.org/10.1373/clinchem.2003.029488

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.