CoChat

Metrologic Traceability of Total Thyroxine Measurements in Human Serum: Efforts to Establish a Network of Reference Measurement Laboratories

Open access
Thienpont, Linda M, Van Uytfanghe, Katleen, Marriot, John, Stokes, Peter, Siekmann, Lothar, Kessler, Anja, Bunk, David, Tai, Susan · 2005 · Clinical Chemistry
Cited by 15

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Assuring/demonstrating metrologic traceability of in vitro diagnostics necessitates the availability of measurand-specific reference measurement systems (RMSs) and the possibility for industry to work with competent reference measurement laboratories (RMLs). Here we report the results of a European project to investigate the feasibility of developing a RMS for serum total thyroxine. Methods: Four candidate RMLs (cRMLs) developed/implemented variants of a candidate reference measurement procedure (cRMP) based on isotope dilution–liquid chromatography–mass spectrometry. The sole constraint implemented was calibration with a common thyroxine primary calibrator. The RMPs were externally validated and assessed for comparability in round-robin trials using common samples, i.e., 5 lyophilized and 33 frozen native sera. At the same time, the performance of the cRMLs organized in a network was assessed. For uniform external quality assessment, common performance specifications were agreed on. Results: All cRMLs performed the cRMPs with fulfillment of the predefined specifications: total and between-laboratory CVs ≤2.0% and 2.5%, respectively, and a systematic deviation ≤0.9%, estimated with a target assigned from the mean of means obtained by the cRMLs. The mean expanded uncertainty for value assignment to the native sera was 2.1%. Conclusions: A network of cRMLs, with externally conformed competence to properly perform RMPs, has been established. Performance specifications were defined and will form the basis for admittance of new network members. A serum panel, successfully targeted during the validation process, is available for split-sample measurements with commercial routine measurement procedures. The model can now be used for other measurands for which traceability to the Système International d’Unités is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2004.041772

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 15

Metadata

Authors
Thienpont, L. M., Van Uytfanghe, K., Marriot, J., Stokes, P., Siekmann, L., Kessler, A., Bunk, D., & Tai, S.
Venue
Clinical Chemistry
Published
2005-01-01
Volume
51
Issue
1
Pages
161-168
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2141042658
Cited by
15
References
3
FWCI
1.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Metrologic Traceability of Total Thyroxine Measurements in Human Serum: Efforts to Establish a Network of Reference Measurement Laboratories. https://app.cochat.ai/papers/10.1373/clinchem.2004.041772
The paper
Thienpont, L. M., Van Uytfanghe, K., Marriot, J., Stokes, P., Siekmann, L., Kessler, A., Bunk, D., & Tai, S. (2005). Metrologic Traceability of Total Thyroxine Measurements in Human Serum: Efforts to Establish a Network of Reference Measurement Laboratories. Clinical Chemistry. https://doi.org/10.1373/clinchem.2004.041772

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.