The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Recommendations for Improving Serum Creatinine Measurement: A Report from the Laboratory Working Group of the National Kidney Disease Education Program
Open accessAbstract
BACKGROUND: Reliable serum creatinine measurements in glomerular filtration rate (GFR) estimation are critical to ongoing global public health efforts to increase the diagnosis and treatment of chronic kidney disease (CKD). We present an overview of the commonly used methods for the determination of serum creatinine, method limitations, and method performance in conjunction with the development of analytical performance criteria. Available resources for standardization of serum creatinine measurement are discussed, and recommendations for measurement improvement are given. METHODS: The National Kidney Disease Education Program (NKDEP) Laboratory Working Group reviewed problems related to serum creatinine measurement for estimating GFR and prepared recommendations to standardize and improve creatinine measurement. RESULTS: The NKDEP Laboratory Working Group, in collaboration with international professional organizations, has developed a plan that enables standardization and improved accuracy (trueness) of serum creatinine measurements in clinical laboratories worldwide that includes the use of the estimating equation for GFR based on serum creatinine concentration that was developed from the Modification of Diet in Renal Disease (MDRD) study. CONCLUSIONS: The current variability in serum creatinine measurements renders all estimating equations for GFR, including the MDRD Study equation, less accurate in the normal and slightly increased range of serum creatinine concentrations [<133 micromol/L (1.5 mg/dL)], which is the relevant range for detecting CKD [<60 mL.min(-1).(1.73 m2)(-1)]. Many automated routine methods for serum creatinine measurement meet or exceed the required precision; therefore, reduction of analytical bias in creatinine assays is needed. Standardization of calibration does not correct for analytical interferences (nonspecificity bias). The bias and nonspecificity problems associated with some of the routine methods must be addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Coresh, J., Astor, B. C., Greene, T., Eknoyan, G., & Levey, A. S. (2003) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2003.50007 · Cited by 2,768
Schwartz, G. J., Haycock, G. B., Edelmann, C. M., & Spitzer, A. (1976) · Pediatrics · doi:10.1542/peds.58.2.259 · Cited by 2,379
(2000) · Journal of the American Society of Nephrology · Cited by 1,718
Serum Creatinine as an Index of Renal Function: New Insights into Old Concepts
Perrone, R. D., Madias, N. E., & Levey, A. S. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.10.1933 · Cited by 1,581
Goodpasture syndrome during the course of a Schönlein-Henoch purpura
Carreras, L., Poveda, R., Bas, J., Mestre, M., Rama, I., & Carrera, M. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32799 · Cited by 1,474
The Kidney: Structure and Function in Health and Disease
(1952) · Postgraduate Medical Journal · doi:10.1136/pgmj.28.317.191-b · Cited by 1,286
Limitations of creatinine as a filtration marker in glomerulopathic patients
Shemesh, O., Golbetz, H., Kriss, J. P., & Myers, B. D. (1985) · Kidney International · doi:10.1038/ki.1985.205 · Cited by 1,227
Davies, D. F., & Shock, N. W. (1950) · Journal of Clinical Investigation · doi:10.1172/jci102286 · Cited by 1,133
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
Coresh, J., Astor, B. C., McQuillan, G., Kusek, J., Greene, T., Van Lente, F., & Levey, A. S. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32765 · Cited by 717
Cystatin C: An Improved Estimator of Glomerular Filtration Rate?
Laterza, O. F., Price, C. P., & Scott, M. G. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.699 · Cited by 658
Effects of Drugs on Clinical Laboratory Tests
Young, D. S., Thomas, D. W., Friedman, R. B., & Pestaner, L. C. (1972) · Clinical Chemistry · doi:10.1093/clinchem/18.10.1041 · Cited by 646
Poggio, E. D., Wang, X., Greene, T., Van Lente, F., & Hall, P. M. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004060447 · Cited by 644
Measurement of renal function in chronic renal disease
Levey, P. D. A. S. (1990) · Kidney International · doi:10.1038/ki.1990.182 · Cited by 564
Automated Reaction-Rate Method for Determination of Serum Creatinine with the CentrifiChem
Fabiny, D. L., & Ertingshausen, G. (1971) · Clinical Chemistry · doi:10.1093/clinchem/17.8.696 · Cited by 543
Endogenous Creatinine in Serum and Urine.
Hare, R. S. (1950) · Experimental Biology and Medicine · doi:10.3181/00379727-74-17837 · Cited by 484
A simple estimate of glomerular filtration ratein full-term infants during the first year of life
Schwartz, G. J., Feld, L. G., & Langford, D. J. (1984) · The Journal of Pediatrics · doi:10.1016/s0022-3476(84)80479-5 · Cited by 465
Cystatin C-Properties and use as diagnostic marker
(2001) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(01)35015-1 · Cited by 418
Analytical Reviews in Clinical Biochemistry: The Estimation of Creatinine
Spencer, K. (1986) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456328602300101 · Cited by 375
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Effects of Drugs on Clinical Laboratory Tests
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-2-175_4 · Cited by 363
Perrone, R. D., Steinman, T. I., Beck, G. J., Skibinski, C. I., Royal, H. D., Lawlor, M., & Hunsicker, L. G. (1990) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(12)81022-5 · Cited by 313
Creatinine Measurement: State of the Art in Accuracy and Interlaboratory Harmonization
Greg Miller, W., Myers, G. L., Ashwood, E. R., Killeen, A. A., Wang, E., Thienpont, L. M., & Siekmann, L. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-297-cmsota · Cited by 286
Self-citationInterferences in current methods for measurements of creatinine
Weber, J. A., & van Zanten, A. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.695 · Cited by 252
Van Pilsum, J. F., Martin, R. P., Kito, E., & Hess, J. (1956) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)50788-8 · Cited by 249
Levey, A. S., Greene, T., Schluchter, M. D., Cleary, P. A., Teschan, P. E., Lorenz, R. A., Molitch, M. E., Mitch, W. E., Siebert, C., & Hall, P. M. (1993) · Journal of the American Society of Nephrology · doi:10.1681/asn.v451159 · Cited by 244
Junge, W., Wilke, B., Halabi, A., & Klein, G. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.02.007 · Cited by 241
Estimating kidney function in adults using formulae
Lamb, E. J., Tomson, C. R., & Roderick, P. J. (2005) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563054889936 · Cited by 238
Lewis, J., Agodoa, L., Cheek, D., Greene, T., Middleton, J., O'Connor, D., Ojo, A., Phillips, R., Sika, M., & Wright, J. (2001) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2001.27691 · Cited by 229
Poggio, E. D., Nef, P. C., Wang, X., Greene, T., Van Lente, F., Dennis, V. W., & Hall, P. M. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.04.023 · Cited by 218
The Kidney: Structure and Function in Health and Disease.
(1951) · Annals of Internal Medicine · doi:10.7326/0003-4819-35-2-483_1 · Cited by 217
Statistical principles underlying analytic goal-setting in clinical chemistry.
Harris, E. K. (1979) · PubMed · Cited by 178
Cook, J. G. H. (1975) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456327501200162 · Cited by 165
Israelit, A. H., Long, D. L., White, M. G., & Hull, A. R. (1973) · Kidney International · doi:10.1038/ki.1973.127 · Cited by 154
Effect of serum-clot contact time on clinical chemistry laboratory results
Zhang, D. J., Elswick, R. K., Miller, W. G., & Bailey, J. L. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.6.1325 · Cited by 147
Murthy, K. K., Stevens, L. A., Stark, P. C., & Levey, A. S. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.00608.x · Cited by 140
Chronic Kidney Disease in the Elderly — How to Assess Risk
Stevens, L. A., & Levey, A. S. (2005) · New England Journal of Medicine · doi:10.1056/nejme058035 · Cited by 137
Mathew, T. H. (2005) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.2005.tb06958.x · Cited by 134
Eckfeldt, J. H., Chambless, L. E., & Shen, Y.-L. (1994) · PubMed · Cited by 122
Clinical Implications of Estimating Equations for Glomerular Filtration Rate
Stevens, L. A., & Levey, A. S. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-141-12-200412210-00013 · Cited by 105
Miller, W. G. (2002) · Clinica Chimica Acta · doi:10.1016/s0009-8981(02)00370-4 · Cited by 104
Gowans, E. M. S., & Fraser, C. G. (1988) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328802500312 · Cited by 90
Positive interference with the Jaffé reaction by cephalosporin antibiotics.
Swain, R., & Briggs, S. L. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.7.1340 · Cited by 86
Ross, J. W., Miller, W. G., Gl, M., & Præstgaard, J. (1998) · PubMed · Cited by 85
COMPARATIVE PHYSIOLOGY OF THE KIDNEY
Smith, H. W. (1953) · JAMA · doi:10.1001/jama.1953.02940340014005 · Cited by 71
Effect of Long-Term Freezer Storage, Thawing, and Refreezing on Selected Constituents of Serum
DiMagno, E. P., CORLE, D., O’Brien, J. F., et al. (1989) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)61285-3 · Cited by 66
Gerard, S. K., & Khayam-Bashi, H. (1985) · American Journal of Clinical Pathology · doi:10.1093/ajcp/84.5.659 · Cited by 60
Cefoxitin Falsely Elevates Creatinine Levels
Saah, A. J. (1982) · JAMA · doi:10.1001/jama.1982.03320270043022 · Cited by 59
Knapp, M. L., & Hadid, O. (1987) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328702400114 · Cited by 58
The reliability of different formulae to predict creatinine clearance
Verhave, J. C., Baljé-Volkers, C. P., Hillege, H. L., de Zeeuw, D., & de Jong, P. E. (2003) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2003.01141.x · Cited by 57
An automated dry-slide enzymatic method evaluated for measurement of creatinine in serum.
Toffaletti, J. G., Blosser, N., Hall, T., Smith, S. E., & Tompkins, D. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.4.684 · Cited by 56
HPLC with enzymatic detection as a candidate reference method for serum creatinine
Línnet, K., & Bruunshuus, I. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.10.1669 · Cited by 44
Creatinine measurement proficiency testing: assignment of matrix-adjusted ID GC-MS target values
Carobene, A., Ferrero, C. A., Ceriotti, F., Modenese, A., Besozzi, M., Giorgi, E. D., Franzin, M., Franzini, C., Kienle, M. G., & Magni, F. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1342 · Cited by 42
Osberg, I. M., & Hammond, K. B. (1978) · Clinical Chemistry · doi:10.1093/clinchem/24.7.1196 · Cited by 36
Liquid-chromatographic measurement of creatinine in serum and urine.
Okuda, T., Oie, T., & Nishida, M. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.5.851 · Cited by 29
An enzymic creatinine assay and a direct ammonia assay in coated thin films.
Sundberg, M. W., Becker, R. W., Esders, T. W., Figueras, J., & Goodhue, C. T. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.4.645 · Cited by 27
Marsilio, R., Dall’Amico, R., Giordano, D., Murer, L., Montini, G., Ros, M., Dussini, N., Zacchello, G., Bacelle, L., & Plebani, M. (1999) · International Journal of Clinical & Laboratory Research · doi:10.1007/s005990050072 · Cited by 26
Falsely Elevated Serum Creatinine Levels Secondary to the Presence of 5-Fluorocytosine
Mitchell, R. T., Marshall, L. H., Lefkowitz, L. B., & Stratton, C. W. (1985) · American Journal of Clinical Pathology · doi:10.1093/ajcp/84.2.251 · Cited by 20
Assessment of a Selected Method for Creatinine with Special Emphasis on Bilirubin Interference
Zwang, L., & BLIJENBERG, B. G. (1991) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1991.29.12.795 · Cited by 20
Schoenmakers, C. H. H., Kuller., T. J., Lindemans, J. W., & BLIJENBERG, B. G. (1993) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1993.31.12.861 · Cited by 14
Interferences of o-raffinose cross-linked hemoglobin in three methods for serum creatinine
Ali, A. C. Y., Mihas, C. C., & Campbell, J. A. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1738 · Cited by 14
HOLMES, E. W., Oeser, T. H., Kahn, S., Bekeris, L. G., & Bermes, E. W. (1983) · PubMed · Cited by 14
Interference by newer cephalosporins in current methods for measuring creatinine
Green, A. J. E., Halloran, S. P., Mould, G. P., Barbour, H. M., Pritchard, J. L., Hallworth, M. J., & Labib, M. A. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.12.2139a · Cited by 9
Interference of Fluorescein with Creatinine Assays
Dick, J. B., Bartlett, W. A., Ibrahim, U., & Coleiro, J. A. (1991) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329102800324 · Cited by 5
Bacterial interference with measurement of creatinine in stored plasma.
Dilena, B. A. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.5.1007 · Cited by 5
Eng, C. D., Delgado, R., & Kroll, M. H. (1993) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1993.31.12.839 · Cited by 1
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Revised Equations for Estimated GFR From Serum Creatinine in Japan
Matsuo, S., Imai, E., Horio, M., Yasuda, Y., Tomita, K., Nitta, K., Yamagata, K., Tomino, Y., Yokoyama, H., & Hishida, A. (2009) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2008.12.034 · Cited by 6,422
Levey, A. S., Coresh, J., Greene, T., Stevens, L. A., Zhang, Y. (., Hendriksen, S., Kusek, J. W., & Van Lente, F. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-4-200608150-00004 · Cited by 5,725
New Equations to Estimate GFR in Children with CKD
Schwartz, G. J., Mun[Combining Tilde]oz, A., Schneider, M. F., Mak, R. H., Kaskel, F., Warady, B. A., & Furth, S. L. (2009) · Journal of the American Society of Nephrology · doi:10.1681/asn.2008030287 · Cited by 3,777
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Metadata
- Authors
- Myers, G. L.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-01-01
- Volume
- 52
- Issue
- 1
- Pages
- 5-18
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2104443849
- Cited by
- 1,232
- References
- 67
- FWCI
- 36.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.