The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
A New Season for Cardiac Troponin Assays: It’s Time to Keep a Scorecard
Abstract
Advancements in cardiac troponin (cTn)1 assay technology have created a conundrum for clinicians and laboratory scientists, who must determine which assays are best for optimal patient care. Unfortunately, few resources are available to guide the medical and scientific communities in this regard. International guidelines (1)(2)(3) have defined an increased cTn above the 99th percentile limit as an abnormal result; what is lacking, unfortunately, is an approach to define this limit across the heterogeneity of the assays. In spite of the evidence-based literature demonstrating that cTn concentrations tend to increase in individuals >60 years old (4), 99th percentile reference limits are often determined across wide age ranges using subjects as old as 70 years (convenience samples). Further frustrating the problem of selecting relevant reference subjects, in clinically defined “normal” individuals without known cardiovascular disease, increased cTn concentrations are indicative of a significantly higher risk of death (4)(5). The occurrence of such individuals in reference populations may reflect inadequate screening for comorbidities at the time of sample acquisition. Given such problems, a majority of laboratories either accept the manufacturer’s reference limit from the US Food and Drug Administration (FDA)-cleared package insert, perform an underpowered normal range study to establish a reference limit, or accept a reference limit published in the literature. To validate cTn assays, however—to level the playing field for all users—is necessary for the best patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Task Force Members, Thygesen, K., Alpert, J. S., White, H. D., Biomarker Group, Jaffe, A. S., Apple, F. S., Galvani, M., Katus, H. A., Newby, L. K., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm355 · Cited by 2,541
Self-citationNACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182882 · Cited by 610
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 474
Self-citationApple, F. S., Quist, H. E., Doyle, P. J., Otto, A. P., & Murakami, M. M. (2003) · Clinical Chemistry · doi:10.1373/49.8.1331 · Cited by 322
Self-citationNACB Writing Group Members, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., & Christenson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.107.182881 · Cited by 300
Self-citationZethelius, B., Johnston, N., & Venge, P. (2006) · Circulation · doi:10.1161/circulationaha.105.570762 · Cited by 280
Sabatine, M. S., Morrow, D. A., de Lemos, J. A., Jarolim, P., & Braunwald, E. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn504 · Cited by 277
NACB WRITING GROUP MEMBERS, Apple, F. S., Jesse, R. L., Newby, L. K., Wu, A. H. B., Christenson, R. H., NACB COMMITTEE MEMBERS, Christenson, R. H., Apple, F. S., Cannon, C. P., et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084715 · Cited by 258
Self-citationApple, F. S., Pearce, L. A., Smith, S. W., Kaczmarek, J. M., & Murakami, M. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.114728 · Cited by 212
Self-citationApple, F. S., Smith, S. W., Pearce, L. A., Ler, R., & Murakami, M. M. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.097162 · Cited by 163
Self-citationWu, A. H. B., & Jaffe, A. S. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.10.016 · Cited by 161
Gibler, W. B., Cannon, C. P., Blomkalns, A. L., Char, D. M., Drew, B. J., Hollander, J. E., Jaffe, A. S., Jesse, R. L., Newby, L. K., Ohman, E. M., et al. (2005) · Circulation · doi:10.1161/01.cir.0000165556.44271.be · Cited by 143
Eggers, K. M., Jaffe, A. S., Lind, L., Venge, P., & Lindahl, B. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.101683 · Cited by 135
Apple, F. S., Parvin, C. A., Buechler, K. F., Christenson, R. H., Wu, A. H. B., & Jaffe, A. S. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.052886 · Cited by 135
Self-citationGibler, W. B., Cannon, C. P., Blomkalns, A. L., Char, D. M., Drew, B. J., Hollander, J. E., Jaffe, A. S., Jesse, R. L., Newby, L. K., Ohman, E. M., et al. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2005.04.022 · Cited by 60
Serum and Plasma Cardiac Troponin I 99th Percentile Reference Values for 3 2nd-Generation Assays
Apple, F. S., & Murakami, M. M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.087718 · Cited by 44
Self-citationAssay Imprecision and 99th-Percentile Reference Value of a High-Sensitivity Cardiac Troponin I Assay
Collinson, P. O., Clifford-Mobley, O., Gaze, D. C., Boa, F. G., & Senior, R. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.124925 · Cited by 37
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
Self-citationHow to use high-sensitivity cardiac troponins in acute cardiac care
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs154 · Cited by 784
Recommendations for the use of cardiac troponin measurement in acute cardiac care
Thygesen, K., Mair, J., Katus, H., Plebani, M., Venge, P., Collinson, P., Lindahl, B., Giannitsis, E., Hasin, Y., Galvani, M., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq251 · Cited by 628
Chow, S. L., Maisel, A. S., Anand, I., Bozkurt, B., de Boer, R. A., Felker, G. M., Fonarow, G. C., Greenberg, B., Januzzi, J. L., Kiernan, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000490 · Cited by 601
Metadata
- Authors
- Apple, F. S.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-07-01
- Volume
- 55
- Issue
- 7
- Pages
- 1303-1306
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2098617627
- Cited by
- 438
- References
- 18
- FWCI
- 24.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.