High-Sensitivity Cardiac Troponin T for Early Prediction of Evolving Non–ST-Segment Elevation Myocardial Infarction in Patients with Suspected Acute Coronary Syndrome and Negative Troponin Results on Admission
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background: We sought to determine the diagnostic performance of the new high-sensitivity cardiac troponin T (hs-cTnT) assay for early detection of non–ST-segment myocardial infarction (NSTEMI) in patients with acute coronary syndrome. Methods: We enrolled patients with retrospectively confirmed unstable angina or NSTEMI and an initially negative cTnT concentration and compared the performance of baseline concentrations and serial changes in concentration within 3 and 6 h. Percentage change criteria included ≥20% δ change and ROC-optimized value. Results: Based on the standard fourth-generation cTnT result of ≥0.03 μg/L, an evolving NSTEMI was diagnosed in 26 patients, and 31 patients were classified as having unstable angina. With the use of the hs-cTnT assay at the 99th-percentile cutoff, the percentage of NSTEMI cases detected increased gradually from 61.5% on presentation to 100% within 6 h, and the overall number of MI diagnoses increased by 34.6% (35 vs 26 cases). A δ change ≥20% or ≥ROC-optimized value of >117% within 3 h or ≥243% within 6 h yielded a specificity of 100% at sensitivities between 69% and 76%. The standard cTnT at the 99th percentile was less sensitive than hs-cTnT for early diagnosis of MI on presentation, and follow-up samples obtained within the initial 3 h demonstrated very low specificity of cTnT compared with hs-cTnT. Conclusions: The high-sensitivity cTnT assay increases the number of NSTEMI diagnoses and enables earlier detection of evolving NSTEMI. A doubling of the hs-cTnT concentration within 3 h in the presence of a second concentration ≥99th percentile is associated with a positive predictive value of 100% and a negative predictive value of 88%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Clinical Investigation Group: Paul W. Armstrong, C. (., Global Perspective Group: Philip A. Poole-Wilson, C. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,230
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Early Diagnosis of Myocardial Infarction with Sensitive Cardiac Troponin Assays
Reichlin, T., Hochholzer, W., Bassetti, S., Steuer, S., Stelzig, C., Hartwiger, S., Biedert, S., Schaub, N., Buerge, C., Potocki, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900428 · Cited by 1,687
Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., & White, H. D. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.011 · Cited by 1,618
Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial Infarction
Keller, T., Zeller, T., Peetz, D., Tzikas, S., Roth, A., Czyz, E., Bickel, C., Baldus, S., Warnholtz, A., Fröhlich, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0903515 · Cited by 1,150
Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,084
Self-citationBraunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00889-5 · Cited by 963
A Sensitive Cardiac Troponin T Assay in Stable Coronary Artery Disease
Omland, T., de Lemos, J. A., Sabatine, M. S., Christophi, C. A., Rice, M. M., Jablonski, K. A., Tjora, S., Domanski, M. J., Gersh, B. J., Rouleau, J. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0805299 · Cited by 901
Angiographie morphology and the pathogenesis of unstable angina pectoris
Ambrose, J. A., Winters, S. L., Stern, A., Eng, A., Teichholz, L. E., Gorlin, R., & Fuster, V. (1985) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(85)80384-3 · Cited by 801
Latini, R., Masson, S., Anand, I. S., Missov, E., Carlson, M., Vago, T., Angelici, L., Barlera, S., Parrinello, G., Maggioni, A. P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.655076 · Cited by 709
Cited by
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
2014 AHA/ACC Guideline for the Management of Patients With Non–ST-Elevation Acute Coronary Syndromes
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.017 · Cited by 3,595
Authors/Task Force Members, Hamm, C. W., Bassand, J.-P., Agewall, S., Bax, J., Boersma, E., Bueno, H., Caso, P., Dudek, D., Gielen, S., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehr236 · Cited by 3,080
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000133 · Cited by 1,254
Hamm, C. W., Bassand, J.-P., Agewall, S., Bax, J., Boersma, E., Bueno, H., Caso, P., Dudek, D., Gielen, S., Huber, K., et al. (2012) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2011.11.006 · Cited by 1,068
Amsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000134 · Cited by 1,059
“If the time of symptom onset is ambiguous, the time of presentation should be considered the time of onset for assessing troponin values (44,45,49).”
BackgroundAmsterdam, E. A., Wenger, N. K., Brindis, R. G., Casey, D. E., Ganiats, T. G., Holmes, D. R., Jaffe, A. S., Jneid, H., Kelly, R. F., Kontos, M. C., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.016 · Cited by 777
Scirica, B. M., Braunwald, E., Raz, I., Cavender, M. A., Morrow, D. A., Jarolim, P., Udell, J. A., Mosenzon, O., Im, K., Umez-Eronini, A. A., et al. (2014) · Circulation · doi:10.1161/circulationaha.114.010389 · Cited by 725
Troponin elevation in coronary vs. non-coronary disease
Agewall, S., Giannitsis, E., Jernberg, T., & Katus, H. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq456 · Cited by 592
Self-citationJCS 2018 Guideline on Diagnosis and Treatment of Acute Coronary Syndrome
Kimura, K., Kimura, T., Ishihara, M., Nakagawa, Y., Nakao, K., Miyauchi, K., Sakamoto, T., Tsujita, K., Hagiwara, N., Miyazaki, S., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0133 · Cited by 565
Serial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial Infarction
Keller, T., Zeller, T., Ojeda, F., Tzikas, S., Lillpopp, L., Sinning, C., Wild, P., Genth-Zotz, S., Warnholtz, A., Giannitsis, E., et al. (2011) · JAMA · doi:10.1001/jama.2011.1896 · Cited by 509
Self-citationReichlin, T., Irfan, A., Twerenbold, R., Reiter, M., Hochholzer, W., Burkhalter, H., Bassetti, S., Steuer, S., Winkler, K., Peter, F., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.023937 · Cited by 460
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2015) · Kardiologia Polska · doi:10.5603/kp.2015.0243 · Cited by 458
Multicenter analytical evaluation of a high-sensitivity troponin T assay
Saenger, A. K., Beyrau, R., Braun, S., Cooray, R., Dolci, A., Freidank, H., Giannitsis, E., Gustafson, S., Handy, B., Katus, H., et al. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.12.034 · Cited by 376
Self-citationChew, D. P., Scott, I. A., Cullen, L., French, J. K., Briffa, T. G., Tideman, P. A., Woodruffe, S., Kerr, A., Branagan, M., & Aylward, P. E. G. (2016) · Heart, Lung and Circulation · doi:10.1016/j.hlc.2016.06.789 · Cited by 314
Möckel, M., Searle, J., Hamm, C., Slagman, A., Blankenberg, S., Huber, K., Katus, H., Liebetrau, C., Müller, C., Muller, R., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu178 · Cited by 220
Self-citationHigh-sensitive troponin T measurements: what do we gain and what are the challenges?
Twerenbold, R., Jaffe, A., Reichlin, T., Reiter, M., & Mueller, C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr492 · Cited by 217
The FINNSEPSIS Study Group, Røsjø, H., Varpula, M., Hagve, T.-A., Karlsson, S., Ruokonen, E., Pettilä, V., & Omland, T. (2011) · Intensive Care Medicine · doi:10.1007/s00134-010-2051-x · Cited by 180
Nagele, P., Brown, F., Gage, B. F., Gibson, D. W., Miller, J. P., Jaffe, A. S., Apple, F. S., & Scott, M. G. (2013) · American Heart Journal · doi:10.1016/j.ahj.2013.04.018 · Cited by 172
“5 and 10 ng/L for women.(15) A manufacturers' notice to users dated May 2012 informed us that the hs-cTnT assay lots used in our study apparently underrecovered hs-cTnT at lower concentrations.”
BackgroundJneid, H., Addison, D., Bhatt, D. L., Fonarow, G. C., Gokak, S., Grady, K. L., Green, L. A., Heidenreich, P. A., Ho, P. M., Jurgens, C. Y., et al. (2017) · Circulation: Cardiovascular Quality and Outcomes · doi:10.1161/hcq.0000000000000032 · Cited by 168
“Patients with prior CABG and NSTE-ACS should receive antiplatelet and anticoagulant therapy according to GDMT and should be strongly considered for early invasive strategy because of their increased risk.(143,145,177,178,189,190) (Class I, Level of Evidence: B) 5.”
BackgroundMethodHaaf, P., Drexler, B., Reichlin, T., Twerenbold, R., Reiter, M., Meissner, J., Schaub, N., Stelzig, C., Freese, M., Heinzelmann, A., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.100867 · Cited by 165
“Coronary artery disease 324 (37) 31 (25) 54 (43) 239 (38) 0.”
Metadata
- Authors
- Giannitsis, E., Becker, M., Kurz, K., Hess, G., Zdunek, D., & Katus, H. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-04-01
- Volume
- 56
- Issue
- 4
- Pages
- 642-650
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2147571213
- Cited by
- 332
- References
- 20
- FWCI
- 30.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.