Pitfalls Associated with the Use of Liquid Chromatography–Tandem Mass Spectrometry in the Clinical Laboratory
Abstract
BACKGROUND: Novel mass spectrometric techniques such as atmospheric pressure ionization and tandem mass spectrometry have substantially extended the spectrum of clinical chemistry methods during the past decade. In particular, liquid chromatography tandem–mass spectrometry (LC-MS/MS) has become a standard tool in research laboratories as well as in many clinical laboratories. Although LC-MS/MS has features that suggest it has a very high analytical accuracy, potential sources of inaccuracy have recently been identified. CONTENT: The sources of inaccuracy in LC-MS/MS methods used in the routine quantification of small molecules are described and discussed. Inaccuracy of LC-MS/MS methods can be related to the process of ionization through the insource transformation of conjugate metabolites or target analytes and may also be attributable to ionization matrix effects that have a differential impact on target analytes and internal-standard compounds. Inaccuracy can also be associated with the process of ion selection, which mainly occurs when compounds from the sample matrix share mass transitions with a target analyte. In individual assays, most potential sources of inaccuracy can be controlled by sufficient LC separation–based sample workup before MS analysis. SUMMARY: LC-MS/MS methods should undergo rigorous and systematic validation before introduction into patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
HMDB: a knowledgebase for the human metabolome
Wishart, D. S., Knox, C., Guo, A. C., Eisner, R., Young, N., Gautam, B., Hau, D. D., Psychogios, N., Dong, E., Bouatra, S., et al. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkn810 · Cited by 1,873
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
The Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Mass spectrometry: principles and applications
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4389 · Cited by 780
Mass spectrometry: principles and applications
(1997) · Choice Reviews Online · doi:10.5860/choice.35-1527 · Cited by 758
Keshishian, H., Addona, T., Burgess, M., Kuhn, E., & Carr, S. A. (2007) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m700354-mcp200 · Cited by 684
Kind, T., & Fiehn, O. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-234 · Cited by 637
Interferences and contaminants encountered in modern mass spectrometry
Keller, B. O., Sui, J., Young, A. B., & Whittal, R. M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.043 · Cited by 623
Stokvis, E., Rosing, H., & Beijnen, J. H. (2005) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1790 · Cited by 588
The Clinical Plasma Proteome: A Survey of Clinical Assays for Proteins in Plasma and Serum
Anderson, N. L. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.126706 · Cited by 562
Does a stable isotopically labeled internal standard always correct analyte response?
Wang, S., Cyronak, M., & Yang, E. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.08.010 · Cited by 401
Keshishian, H., Addona, T., Burgess, M., Mani, D. R., Shi, X., Kuhn, E., Sabatine, M. S., Gerszten, R. E., & Carr, S. A. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900140-mcp200 · Cited by 286
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Kuhn, E., Addona, T., Keshishian, H., Burgess, M., Mani, D. R., Lee, R. T., Sabatine, M. S., Gerszten, R. E., & Carr, S. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.123935 · Cited by 247
A decade of HPLC–MS/MS in the routine clinical laboratory — Goals for further developments
Vogeser, M., & Seger, C. (2008) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.02.017 · Cited by 240
Self-citationRauh, M., Gröschl, M., Rascher, W., & Dörr, H. G. (2006) · Steroids · doi:10.1016/j.steroids.2006.01.015 · Cited by 170
Lindegardh, N., Annerberg, A., White, N. J., & Day, N. P. J. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.12.011 · Cited by 160
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Kushnir, M. M., Rockwood, A. L., & Bergquist, J. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20264 · Cited by 159
Accurate Inclusion Mass Screening
Jaffe, J. D., Keshishian, H., Chang, B., Addona, T. A., Gillette, M. A., & Carr, S. A. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800218-mcp200 · Cited by 155
Assessing analytical specificity in quantitative analysis using tandem mass spectrometry
Kushnir, M. M., Rockwood, A. L., Nelson, G. J., Yue, B., & Urry, F. M. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.12.003 · Cited by 152
How specific is my SRM?: The issue of precursor and product ion redundancy
Sherman, J., McKay, M. J., Ashman, K., & Molloy, M. P. (2009) · PROTEOMICS · doi:10.1002/pmic.200800577 · Cited by 150
Thienpont, L. M., Uytfanghe, K. V., Blincko, S., Ramsay, C. S., Xie, H., Doss, R. C., Keevil, B. G., Owen, L. J., Rockwood, A. L., Kushnir, M. M., et al. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.105841 · Cited by 146
Protein Quantitation through Targeted Mass Spectrometry: The Way Out of Biomarker Purgatory?
Carr, S. A., & Anderson, L. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.114686 · Cited by 141
Seger, C., Tentschert, K., Stöggl, W., Griesmacher, A., & Ramsay, S. L. (2009) · Nature Protocols · doi:10.1038/nprot.2009.25 · Cited by 119
Self-citation25-Hydroxyvitamin D Assays: The Quest For Accuracy
Carter, G. D. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.125906 · Cited by 117
Peer Reviewed: Scaling MS Plateaus with High-Resolution FT-ICRMS
Marshall, A. G., Hendrickson, C. L., & Shi, S. D. ‐. (2002) · Analytical Chemistry · doi:10.1021/ac022010j · Cited by 115
Current role of LC-MS in therapeutic drug monitoring
Saint‐Marcoux, F., Sauvage, F., & Marquet, P. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1320-1 · Cited by 113
Oberacher, H., Pavlic, M., Libiseller, K., Schubert, B., Sulyok, M., Schuhmacher, R., Csaszar, E., & Köfeler, H. C. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1545 · Cited by 113
Carter, G. D., & Jones, J. C. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008135 · Cited by 99
Jansen, R. S., Lachâtre, G., & Marquet, P. P. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.003 · Cited by 95
Can Mass Spectrometric Protein Profiling Meet Desired Standards of Clinical Laboratory Practice?
Hortin, G. L. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.043281 · Cited by 91
Ionita, I. A., Fast, D. M., & Akhlaghi, F. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.02.019 · Cited by 84
Yan, Z., Caldwell, G. W., Jones, W. J., & Masucci, J. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1071 · Cited by 83
Gustavsson, E., Andersson, M., Stephanson, N., & Beck, O. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1219 · Cited by 82
X-Rank: A Robust Algorithm for Small Molecule Identification Using Tandem Mass Spectrometry
Mylonas, R., Mauron, Y., Masselot, A., Binz, P., Budin, N., Fathi, M., Viette, V., Hochstrasser, D. F., & Lisacek, F. (2009) · Analytical Chemistry · doi:10.1021/ac900954d · Cited by 79
Xuan, Y., Creese, A. J., Horner, J. A., & Cooper, H. J. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4101 · Cited by 78
Carvalho, V. M., Nakamura, O. H., & Vieira, J. G. H. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2008.07.035 · Cited by 77
Hopley, C. J., Bristow, T. W. T., Lubben, A., Simpson, A., Bull, E., Klagkou, K., Herniman, J., & Langley, G. J. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3545 · Cited by 77
Exploring the boundaries of bioanalytical quantitative LC–MS–MS
Lagerwerf, F. M., van Dongen, W. D., Steenvoorden, R. J. J. M., et al. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00009-1 · Cited by 66
Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.134049 · Cited by 57
A liquid chromatography/mass spectrometry method for the evaluation of intestinal permeability
Lostia, A. M., Lionetto, L., Principessa, L., Evangelisti, M., Gamba, A., Villa, M. P., & Simmaco, M. (2008) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.03.016 · Cited by 55
Pitfalls in measuring the endocannabinoid 2-arachidonoyl glycerol in biological samples
Vogeser, M., & Schelling, G. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.197 · Cited by 51
Self-citationZhang, H., & Henion, J. D. (2001) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00132-3 · Cited by 46
Havlíková, H., Hill, M., Hampl, R., & Stárka, L. (2002) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.87.5.8499 · Cited by 45
Calbiani, F., Careri, M., Elviri, L., Mangia, A., & Zagnoni, I. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.984 · Cited by 43
Careri, M., & Mangia, A. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0581-4 · Cited by 29
Cited by
Han, J., Lin, K., Sequeira, C., & Borchers, C. H. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.11.015 · Cited by 521
Gosselin, R., Adcock, D., Bates, S., Douxfils, J., Favaloro, E., Gouin-Thibault, I., Guillermo, C., Kawai, Y., Lindhoff-Last, E., & Kitchen, S. (2018) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1627480 · Cited by 392
After another decade: LC–MS/MS became routine in clinical diagnostics
Seger, C., & Salzmann, L. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.03.004 · Cited by 301
Self-citationJiang, X., Sidhu, R., Porter, F. D., Yanjanin, N. M., Speak, A. O., te Vruchte, D. T., Platt, F. M., Fujiwara, H., Scherrer, D. E., Zhang, J., et al. (2011) · Journal of Lipid Research · doi:10.1194/jlr.d015735 · Cited by 270
LC–MS/MS analysis of steroids in the clinical laboratory
Keevil, B. G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.009 · Cited by 149
Metadata
- Authors
- Vogeser, M., & Seger, C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08-01
- Volume
- 56
- Issue
- 8
- Pages
- 1234-1244
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2170411837
- Cited by
- 290
- References
- 51
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.