Pitfalls Associated with the Use of Liquid Chromatography–Tandem Mass Spectrometry in the Clinical Laboratory
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Novel mass spectrometric techniques such as atmospheric pressure ionization and tandem mass spectrometry have substantially extended the spectrum of clinical chemistry methods during the past decade. In particular, liquid chromatography tandem–mass spectrometry (LC-MS/MS) has become a standard tool in research laboratories as well as in many clinical laboratories. Although LC-MS/MS has features that suggest it has a very high analytical accuracy, potential sources of inaccuracy have recently been identified. CONTENT: The sources of inaccuracy in LC-MS/MS methods used in the routine quantification of small molecules are described and discussed. Inaccuracy of LC-MS/MS methods can be related to the process of ionization through the insource transformation of conjugate metabolites or target analytes and may also be attributable to ionization matrix effects that have a differential impact on target analytes and internal-standard compounds. Inaccuracy can also be associated with the process of ion selection, which mainly occurs when compounds from the sample matrix share mass transitions with a target analyte. In individual assays, most potential sources of inaccuracy can be controlled by sufficient LC separation–based sample workup before MS analysis. SUMMARY: LC-MS/MS methods should undergo rigorous and systematic validation before introduction into patient care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
HMDB: a knowledgebase for the human metabolome
Wishart, D. S., Knox, C., Guo, A. C., Eisner, R., Young, N., Gautam, B., Hau, D. D., Psychogios, N., Dong, E., Bouatra, S., et al. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkn810 · Cited by 1,873
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
The Orbitrap: a new mass spectrometer
Hu, Q., Noll, R. J., Li, H., Makarov, A., Hardman, M., & Graham Cooks, R. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.856 · Cited by 1,333
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (1998) · Analytical Chemistry · doi:10.1021/ac971078+ · Cited by 880
Mass spectrometry: principles and applications
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4389 · Cited by 780
Mass spectrometry: principles and applications
(1997) · Choice Reviews Online · doi:10.5860/choice.35-1527 · Cited by 758
Cited by
Han, J., Lin, K., Sequeira, C., & Borchers, C. H. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.11.015 · Cited by 521
Gosselin, R., Adcock, D., Bates, S., Douxfils, J., Favaloro, E., Gouin-Thibault, I., Guillermo, C., Kawai, Y., Lindhoff-Last, E., & Kitchen, S. (2018) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1627480 · Cited by 392
After another decade: LC–MS/MS became routine in clinical diagnostics
Seger, C., & Salzmann, L. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.03.004 · Cited by 301
Self-citationJiang, X., Sidhu, R., Porter, F. D., Yanjanin, N. M., Speak, A. O., te Vruchte, D. T., Platt, F. M., Fujiwara, H., Scherrer, D. E., Zhang, J., et al. (2011) · Journal of Lipid Research · doi:10.1194/jlr.d015735 · Cited by 270
Stable isotope-resolved metabolomics and applications for drug development
Fan, T. W.-M., Lorkiewicz, P. K., Sellers, K., Moseley, H. N. B., Higashi, R. M., & Lane, A. N. (2012) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2011.12.007 · Cited by 209
“abundant non-targeted analytes and salts) interference (Lagerwerf, van Dongen et al. 2000; Taylor 2005; Vogeser and Seger 2010) can be dealt with.”
BackgroundHan, J., Liu, Y., Wang, R., Yang, J., Ling, V., & Borchers, C. H. (2015) · Analytical Chemistry · doi:10.1021/ac503816u · Cited by 188
Fanelli, F., Belluomo, I., Di Lallo, V. D., Cuomo, G., De Iasio, R., Baccini, M., Casadio, E., Casetta, B., Vicennati, V., Gambineri, A., et al. (2011) · Steroids · doi:10.1016/j.steroids.2010.11.005 · Cited by 188
Le, A., Ng, A., Kwan, T., Cusmano-Ozog, K., & Cowan, T. M. (2014) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.11.017 · Cited by 159
LC–MS/MS analysis of steroids in the clinical laboratory
Keevil, B. G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.009 · Cited by 149
Hoofnagle, A. N., Becker, J. O., Oda, M. N., Cavigiolio, G., Mayer, P., & Vaisar, T. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.173856 · Cited by 140
Kulle, A., Krone, N., Holterhus, P. M., Schuler, G., Greaves, R. F., Juul, A., de Rijke, Y. B., Hartmann, M. F., Saba, A., Hiort, O., et al. (2017) · European Journal of Endocrinology · doi:10.1530/eje-16-0953 · Cited by 111
Carvalho, V. M. (2012) · Journal of Chromatography B · doi:10.1016/j.jchromb.2011.08.027 · Cited by 90
Zander, J., Maier, B., Suhr, A., Zoller, M., Frey, L., Teupser, D., & Vogeser, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0746 · Cited by 85
Self-citationJanzen, N., Sander, S., Terhardt, M., Steuerwald, U., Peter, M., Das, A. M., & Sander, J. (2011) · Steroids · doi:10.1016/j.steroids.2011.07.013 · Cited by 66
Case for the wider adoption of mass spectrometry-based adrenal steroid testing, and beyond
Monaghan, P. J., Keevil, B. G., Stewart, P. M., & Trainer, P. J. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2258 · Cited by 41
Kalogera, E., Pistos, C., Provatopoulou, X., Athanaselis, S., Spiliopoulou, C., & Gounaris, A. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.09.022 · Cited by 31
Richards, K. H., Monk, R., Renko, K., Rathmann, D., Rijntjes, E., & Köhrle, J. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01941-9 · Cited by 27
Richards, K., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2017.01.032 · Cited by 23
Richards, K. H., Schanze, N., Monk, R., Rijntjes, E., Rathmann, D., & Köhrle, J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0183482 · Cited by 15
Semi-automated serum steroid profiling with tandem mass spectrometry
Rakete, S., Schubert, T., & Vogeser, M. (2023) · Journal of Mass Spectrometry and Advances in the Clinical Lab · doi:10.1016/j.jmsacl.2022.12.006 · Cited by 10
“, the loss of water during mass spectrometric analysis [2].”
BackgroundSelf-citation
Metadata
- Authors
- Vogeser, M., & Seger, C.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-08-01
- Volume
- 56
- Issue
- 8
- Pages
- 1234-1244
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2170411837
- Cited by
- 290
- References
- 51
- FWCI
- 12.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.