The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Abstract
BACKGROUND: Cardiac troponins I (cTnI) and T (cTnT) have received international endorsement as the standard biomarkers for detection of myocardial injury, for risk stratification in patients suspected of acute coronary syndrome, and for the diagnosis of myocardial infarction. An evidence-based clinical database is growing rapidly for high-sensitivity (hs) troponin assays. Thus, clarifications of the analytical principles for the immunoassays used in clinical practice are important. CONTENT: The purpose of this mini-review is (a) to provide a background for the biochemistry of cTnT and cTnI and (b) to address the following analytical questions for both hs cTnI and cTnT assays: (i) How does an assay become designated hs? (ii) How does one realistically define healthy (normal) reference populations for determining the 99th percentile? (iii) What is the usual biological variation of these analytes? (iv) What assay imprecision characteristics are acceptable? (v) Will standardization of cardiac troponin assays be attainable? SUMMARY: This review raises important points regarding cTnI and cTnT assays and their reference limits and specifically addresses hs assays used to measure low concentrations (nanograms per liter or picograms per milliliter). Recommendations are made to help clarify the nomenclature. The review also identifies further challenges for the evolving science of cardiac troponin measurement. It is hoped that with the introduction of these concepts, both laboratorians and clinicians can develop a more unified view of how these assays are used worldwide in clinical practice.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This specific peptide (HWQIAYNEHQWQ) not only exhibits an impressive binding affinity (Kd) of 270 pM comparable to that of antibodies37, but also targets the central portion of cTnI (amino acid residues 114–144) with less susceptibility to proteolysis and is postulated to be an optimal targeting epitope to detect all forms of cTnI present in blood circulation38–40.”
From Nanoproteomics enables proteoform-resolved analysis of low-abundance proteins in human serum (2020) · cites this paper as [40]
Citations
Cites
Universal Definition of Myocardial Infarction
Thygesen, K. A., Alpert, J. S., White, H. D., TASK FORCE MEMBERS: Chairpersons: Kristian Thygesen (Denmark), J. S. A. (., Biomarker Group: Allan S. Jaffe, C. (., ECG Group: Bernard Chaitman, C.-O. (., Imaging Group: Richard Underwood, C. (., Intervention Group: Jean-Pierre Bassand, C.-O. (., Mendis, S., Implementation Group: Lars C. Wallentin Coordinator (Sweden), F. F.-A. (., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.187397 · Cited by 4,422
Thygesen, K. A. (2007) · Circulation · Cited by 3,126
Task Force Members, Thygesen, K. A., Alpert, J. S., White, H. D., Biomarker Group, Jaffe, A. S., Apple, F. S., Galvani, M., Katus, H. A., Newby, L. K., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm355 · Cited by 2,536
Self-citationCardiac troponin I. A marker with high specificity for cardiac injury.
Adams, J. E., Bodor, G. S., Dávila‐Román, V. G., Delmez, J. A., Apple, F. S., Ladenson, J. H., & Jaffe, A. S. (1993) · Circulation · doi:10.1161/01.cir.88.1.101 · Cited by 1,149
Self-citationde Lemos, J. A., Drazner, M. H., Omland, T., Ayers, C. R., Khera, A., Rohatgi, A. K., Hashim, I. A., Berry, J. D., Das, S. R., Morrow, D. A., et al. (2010) · JAMA · doi:10.1001/jama.2010.1768 · Cited by 1,103
Analytical Validation of a High-Sensitivity Cardiac Troponin T Assay
Giannitsis, E., Kurz, K., Hallermayer, K., Jarausch, J., Jaffe, A. S., & Katus, H. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2009.132654 · Cited by 1,087
deFilippi, C. R., de Lemos, J. A., Christenson, R. H., Gottdiener, J. S., Kop, W. J., Zhan, M., & Seliger, S. L. (2010) · JAMA · doi:10.1001/jama.2010.1708 · Cited by 715
Katus, H. A., Remppis, A. B., Scheffold, T., Diederich, K. W., & Kübler, W. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90466-x · Cited by 557
NACB WRITING GROUP MEMBERS, Morrow, D. A., Cannon, C. P., Jesse, R. L., Newby, L. K., Ravkilde, J., Storrow, A. B., Wu, A. H. B., Christenson, R. H., Christenson, R. H., et al. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.084194 · Cited by 475
Self-citationReichlin, T., Irfan, A. B., Twerenbold, R., Reiter, M., Hochholzer, W., Burkhalter, H., Bassetti, S., Steuer, S., Winkler, K., Peter, F., et al. (2011) · Circulation · doi:10.1161/circulationaha.111.023937 · Cited by 459
Flagged first, then by citations
Research works printed but not linked: 1
- Apple, 2011, Short-term biological variation of cardiac troponin I measured with three high-sensitivity assays [Abstract], Clin Chem, 57, C05
Cited by
Sorted by citations
Items 801–860 of 860
Laboratory Markers of COVID-19 in the Emergency Room
Assandri, R. (2022) · Biomarkers in disease · doi:10.1007/978-3-030-87302-8_41-1
Issues Related to High-Sensitivity Troponin Assays
Tada, M., Ichihashi, T., Hachiya, K., Yamada, K., & Saeki, T. (2022) · Circulation Reports · doi:10.1253/circrep.cr-22-0081
Laboratory Markers of COVID-19 in the Emergency Room
Assandri, R. (2023) · Biomarkers in disease · doi:10.1007/978-3-031-07395-3_41
ARACI, Ç. E., Duyan, M., Kartal, M., & Göksu, E. (2022) · Akdeniz Medical Journal · doi:10.53394/akd.1032104
Comparison of high‐sensitive cardiac troponin T and I in patients with chronic coronary syndrome
Caselli, C., Ragusa, R., Liga, R., Prontera, C., Gimelli, A., Scholte, A. J. H. A., Knuuti, J. M., Clerico, A., Neglia, D., & EVINCI Investigators (2023) · European Journal of Clinical Investigation · doi:10.1111/eci.14010
Chaulin, A. M. (2023) · Cardiovascular & Hematological Agents in Medicinal Chemistry · doi:10.2174/1871525721666230428161034
Oyama, M. A. (2023) · Small Animal Critical Care Medicine · doi:10.1016/b978-0-323-76469-8.00061-7
Wang, L., Zhang, W., Song, B., Zhang, Z., Li, J., Li, X., & Yao, J. L. (2023) · Nanotechnology · doi:10.1088/1361-6528/ad1163
Chen, L., Wang, W., Wang, L., Wang, N., Dong, S., Ding, Y., Chen, G.-Z., Jiang, H., Yu, X., & Sun, C. (2023) · Journal of Laboratory Medicine · doi:10.1515/labmed-2022-0173
Current Evidence for the Use of High-Sensitivity Troponin Assays in the Emergency Department
Burke, E. (2024) · Current Emergency and Hospital Medicine Reports · doi:10.1007/s40138-024-00282-x
Shuai, Y., Liu, Y., Wang, X., Wan, Q., Li, Z., & Wu, J. (2024) · Research Square · doi:10.21203/rs.3.rs-4008930/v1
Earlier Diagnosis the Myocardial Infarction of Older Patients by Troponin Test
Hnewa, R. A. A. (2024) · Academic International Journal of Medical Sciences · doi:10.59675/m215
The value of troponin measurement in carotid revascularization: are we making the most of it?
Jovanović, K., Trailović, R., Jovanovic, M. D., & KONCAR, I. B. (2024) · Italian Journal of Vascular and Endovascular Surgery · doi:10.23736/s1824-4777.24.01675-9
Tork, A., Labib, M., Rabea, A., & Ali, A. A. (2024) · Research Square · doi:10.21203/rs.3.rs-5299564/v1
Use of Cardiac Troponin Assays in Hemodialysis Patients
Kolland, M., Rainer, P. P., & Kirsch, A. H. (2024) · Blood Purification · doi:10.1159/000542336
Biochemical Markers of Acute Coronary Syndromes
Liu, L., & Cao, J. (2024) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0507.pub2
GILL, S., EMBLIN, K., DANIELS, R., & Mokbel, K. (2024) · In Vivo · doi:10.21873/invivo.13856
Chest Pain With Significantly Elevated Troponins: Be Wary of False Positives
Narayanan, T. T., Naneishvili, T., Moody, W. E., Townend, J., & Ludman, P. (2025) · Cureus · doi:10.7759/cureus.77018
Azuma, H., Tada, M., Matano, H., Yamada, N., Uzui, H., Fujino, S., Maeno, K., Shimada, Y., Yoshida, H., Murahashi, H., et al. (2025) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2025.110897
Thomsen, T., Funken, M., Nickenig, G., & Becher, M. U. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14061855
Pharmacologic agents for perioperative cardioprotection in noncardiac surgery
Garcia, W. N. D. P., & Hert, S. G. D. (2025) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001494
New generation of hs cardiac troponins and diagnosis of acute coronar syndrome - minireview
Friedecky, B., & Kratochvíla, J. (2013) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2013.037
High-Sensitivity Troponin Zones: An Alternative Approach to Clinical Decisions
Rokos, I. C., Mattu, A., & Jaffe, A. S. (2025) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2025.04.014
Boğa, E. (2025) · Emergency Medicine Australasia · doi:10.1111/1742-6723.70075
Defining Chronic Myocyte Injury With hs-cTnT
Miller, G., Davies, S. L., Hatherley, J. D., Lambert, A., Fearon, H., Bailey, L. M., Collinson, P. O., & Khand, A. U. (2025) · JACC Case Reports · doi:10.1016/j.jaccas.2025.103631
Self-citationLa troponine en pratique, mais au fait à quoi ça sert ?
Émile, C. (2025) · Option/Bio · doi:10.1016/s0992-5945(25)74790-x
Boc, V., Blinc, A., & Boc, A. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms262211214
Qureshi, M. A., Cook, B. C., Brennan, B., Miller, J. B., & McCord, J. (2025) · Clinical Research in Cardiology · doi:10.1007/s00392-025-02789-z
Performance evaluation of a new high-sensitivity cardiac troponin T assay: hs-cTnT (CLIA) assay
Shu, X., Zhang, C., Deng, T., Jing, Y., Wang, H., Li, X., Zhu, J., Li, L., Zhang, Z., & Zhang, L. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1258
Friedman, T., Leviner, D. B., Chan, V. L., Yanagawa, B., Orbach, A., Natour, A. E. H., Weis, A., Sharoni, E., & Bolotin, G. (2023) · Figshare · doi:10.6084/m9.figshare.23700558
Echouffo-Tcheugui, J. B., Musani, S. K., Bertoni, A. G., Correa, A., Fox, E. R., & Mentz, R. J. (2022) · Figshare · doi:10.6084/m9.figshare.19959898
Teren, A., Netto, J., Thiery, J., Thiele, H., Stellbrink, C., Lawin, D., Lawrenz, T., Derda, A. A., Henger, S., Kirsten, H., et al. (2025) · medRxiv · doi:10.64898/2025.12.18.25342624
Salvatici, M., Carreras, F., Gaimarri, M., Corrado, C., Bianchi, B., & Drago, L. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5959694
Assessment of PTAH and Troponin-I in Detecting Early Myocardial Infarction Postmortem
Vidhya, R., & Murthi, P. (2025) · Journal of MedVerse Research & Practice · doi:10.65188/nurexus.1020
Ranjan, R., Abha, P., Kumar, D., Kumari, R., & Pranay, K. (2025) · Student s Journal of Health Research Africa · doi:10.51168/sjhrafrica.v6i12.2271
Periprocedural Myocardial Infarction: Do We Need an Updated Definition?
Alvarez, M. C., Bavuso, L. L., Leo, M. D., Basile, M., Vasumini, N., Manaresi, T., Maida, A., Moretti, M., Cavallo, D., Canton, L., et al. (2026) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd13030112
Measurement integrity in modern clinical practice: Bringing precision to everyday decision-making
Fleming, R. M. (2026) · The American Journal of Medicine · doi:10.1016/j.amjmed.2026.02.036
Patrier, L. (2014) · theses.fr (ABES) · doi:10.70675/856fba23zd92az4508z88b4z4a6cd1d739dd
Salvatici, M., Carreras, F., Gaimarri, M., Corrado, C., Bianchi, B., & Drago, L. (2026) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2026.e00532
Multicenter reference limits of hs-cTnI and NT-proBNP in a Chinese cohort
Xu, Y., Li, Q., Xie, H., Hou, L., Xu, P., Cui, H., Chen, X., Zhang, X., Peng, Z., Zhou, H., et al. (2026) · Diagnosis · doi:10.1515/dx-2026-0045
Abbas, S. S., Mohammad, S. S., AlRufaei, I. A., Almayahi, W. M., Najem, H. A., & Khaleefah, I. A. (2026) · Journal of Veterinary Clinics · doi:10.17555/jvc.2026.43.2.102
Maseti, A. A., Jacob, D., Khoza, S. P., & Chikomba, C. E. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121054
Lippmann, A. J., Qureshi, A., Khan, M., Azhar, M., Qazi, F., Awan, M., & Tauberg, S. (2026) · Cureus · doi:10.7759/cureus.109879
Teren, A., Netto, J., Thiery, J., Thiele, H., Stellbrink, C., Lawin, D., Lawrenz, T., Derda, A. A., Henger, S., Kirsten, H., et al. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.048737
Sixth Generation High-Sensitivity Cardiac Troponin T: Will a Better Assay Make a Better Biomarker?
Pollock, A., Thurston, A. J. F., Chapman, A. R., & Mills, N. L. (2026) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfag085
Владимирович, М. Н., Chashchin, M. G., Kutsenko, V. A., Иванова, А. А., Shalnova, S. A., & Drapkina, O. M. (2026) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2026-3315
zheming, Z., wenjia, H., & Pei, M. (2026) · Research Square · doi:10.21203/rs.3.rs-10447902/v1
Ho, K.-L., Huang, T.-H., Kessinger, P., Ding, J., & Fan, S. (2026) · Analytical Chemistry · doi:10.1021/acs.analchem.6c03569
Biomarkers in acute heart failure
Choudhary, R., Wettersten, N. W., Shah, K., & Maisel, A. (2021) · doi:10.1093/med/9780198849346.003.0034_update_001
Debekeme, W. B., Alpha, H. E., OkoyeOkoye, O. E., & Amakoromo, T. E. (2026) · Greener Journal of Biomedical and Health Sciences · doi:10.15580/gjbhs.2026.1.091026159
Troponin: biology, molecular mechanisms, and multidimensional clinical applications
Adamcová, M., & Petráň, L. (2026) · Molecular Biomedicine · doi:10.1186/s43556-026-00597-z
Gao, Z., Li, J., & Jiang, D. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.122885
van Daalen, L. E., Schueler, B. L. F., Collinson, P. O., & Backus, B. E. (2026) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000001381
Self-citationMujawar, A. K., Dhanavade, S. S., D'souza, A., & Bansode, P. V. (2026) · Cureus · doi:10.7759/cureus.118350
Xiao, Y., & Xiang, T. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1956085
« Troponines » SFBC, S. E. S., Chenevier‐Gobeaux, C., Bonnefoy‐Cudraz, E., Charpentier, S., Dehoux, M., Lefèvre, G., Meune, C., & Ray, P. (2014) · Annales françaises de médecine d’urgence · doi:10.1007/s13341-014-0423-5
Metadata
- Authors
- Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers
- Affiliations
- University of Minnesota (US)
- St George's Hospital (GB)
- Corresponding author
- Apple, Fred S
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-01
- Volume
- 58
- Issue
- 1
- Pages
- 54-61
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2151231511
- Cited by
- 861
- References
- 41
- Citations by year
- 2026: 26 · 2025: 39 · 2024: 33 · 2023: 42 · 2022: 44 · 2021: 51 · 2020: 53 · 2019: 58 · 2018: 63 · 2017: 87 · 2016: 88 · 2015: 69 · 2014: 75 · 2013: 81 · 2012: 46
- FWCI
- 11.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model (vor)
- Locations
- Clinical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Siemens
- Abbott
- Radiometer
- B.R.A.H.M.S.
- Roche
- Alere
- Instrumentation Laboratories
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Life Sciences › Immunology and Microbiology › Immunology › Biomarkers in Disease Mechanisms
- Keywords
- high-sensitivity troponin I, high-sensitivity troponin T, cardiac troponin assays, assay standardization, reference limits, biological variation, assay imprecision, myocardial injury biomarkers, acute coronary syndrome, myocardial infarction diagnosis
- MeSH terms
- Humans, Immunoassay, Myocardial Infarction, Myocardium, Reference Values, Sensitivity and Specificity, Biomarkers, Troponin I, Troponin T, Acute Coronary Syndrome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review