Losing the dogmatic view of cerebral autoregulation
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
In 1959, Niels Lassen illustrated the cerebral autoregulation curve in the classic review article entitled Cerebral Blood Flow and Oxygen Consumption in Man. This concept suggested a relatively broad mean arterial pressure range (~60-150 mmHg) wherein cerebral blood flow remains constant. However, the assumption that this wide cerebral autoregulation plateau could be applied on a within-individual basis is incorrect and greatly variable between individuals. Indeed, each data point on the autoregulatory curve originated from independent samples of participants and patients and represented interindividual relationships between cerebral blood flow and mean arterial pressure. Nonetheless, this influential concept remains commonly cited and illustrated in various high-impact publications and medical textbooks, and is frequently taught in medical and science education without appropriate nuances and caveats. Herein, we provide the rationale and additional experimental data supporting the notion we need to lose this dogmatic view of cerebral autoregulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cerebral Blood Flow and Oxygen Consumption in Man
Lassen, N. A. (1959) · Physiological Reviews · doi:10.1152/physrev.1959.39.2.183 · Cited by 2,070 · cited 11×
“Since the publication of Lassen's autoregulatory curve (Lassen, 1959) [and the update by Paulson et al.”
BackgroundMethodInfluentialOn the Regulation of the Blood‐supply of the Brain
Roy, C. S., & Sherrington, C. S. (1890) · The Journal of Physiology · doi:10.1113/jphysiol.1890.sp000321 · Cited by 1,822 · cited 3×
“…has been challenged and updated since its inception (Kalisvaart et al., 2020; Wilson, 2016)); (2) the notion cerebral metabolism influences CBF (Mosso, 1880; Roy & Sherrington, 1890); and (3) perturbations to the systemic circulation are detected in the cerebral circulation (Bayliss et al., 1895).”
BackgroundInfluentialCerebral autoregulation dynamics in humans.
Aaslid, R., Lindegaard, K. F., Sorteberg, W., & Nornes, H. (1989) · Stroke · doi:10.1161/01.str.20.1.45 · Cited by 1,632
The J-Curve Phenomenon in Hypertension
Kang, Y.-Y., & Wang, J.-G. (2016) · Pulse · doi:10.1159/000446922 · Cited by 1,530
Ganong's Review of Medical Physiology
Barrett, K. E. (2009) · Repository of the University of Ljubljana (University of Ljubljana) · Cited by 1,153
Paulson, O. B., Strandgaard, S., & Edvinsson, L. (1990) · PubMed · Cited by 1,111
Regulation of cerebral blood flow in humans: physiology and clinical implications of autoregulation
Claassen, J. A. H. R., Thijssen, D. H. J., Panerai, R. B., & Faraci, F. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00022.2020 · Cited by 915 · cited 1×
“The reader is invited to read the excellent comprehensive review article by Claassen et al. (2021) for a complete understanding of physiological and clinical implications of cerebral autoregulation.”
BackgroundIntegrative regulation of human brain blood flow
Willie, C. K., Tzeng, Y., Fisher, J. A., & Ainslie, P. N. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2013.268953 · Cited by 872 · cited 7×
“…describing the within- individual relationship between CBF and mean arterial pressure provide a substantial basis that indicates blood flow in the brain is not constant over an extended range of mean arterial pressure (Tan, 2012; Tan et al., 2013; Tzeng & Ainslie, 2013; Willie et al., 2014).”
BackgroundMethodInfluentialSelf-citationTransfer function analysis of dynamic cerebral autoregulation in humans
Zhang, R., Zuckerman, J. H., Giller, C. A., & Levine, B. D. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.1.h233 · Cited by 848 · cited 9×
“In contrast, dynamic cerebral autoregulation generally refers to the cerebral pressure– flow relationship as observed during transient changes (over a period of seconds) in mean arterial pressure (Tzeng & Ainslie, 2013) (Figure 3).”
BackgroundInfluentialWillie, C. K., Colino, F. L., Bailey, D. M., Tzeng, Y. C., Binsted, G., Jones, L. W., Haykowsky, M. J., Bellapart, J., Ogoh, S., Smith, K. J., et al. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.01.011 · Cited by 546 · cited 1×
“Transcranial Doppler ultrasound measurements can indeed only be representative of (regional) CBF if the diameter of the artery of interest remains constant (Willie et al., 2011).”
BackgroundSelf-citationClaassen, J. A., Meel-van den Abeelen, A. S., Simpson, D. M., Panerai, R. B., & on behalf of the international Cerebral Autoregulation Research Network (CARNet) (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x15626425 · Cited by 475 · cited 3×
“Transcranial Doppler ultrasound has been regularly used in studies examining CBF regulation and cerebral autoregulation (particularly dynamic cerebral autoregulation) for many reasons (Claassen et al., 2016).”
BackgroundMethodInfluentialWilson, M. H. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16648711 · Cited by 390 · cited 1×
“…primarily: (1) the Monro– Kellie doctrine (Abercrombie, 1836) (which has been challenged and updated since its inception (Kalisvaart et al., 2020; Wilson, 2016)); (2) the notion cerebral metabolism influences CBF (Mosso, 1880; Roy & Sherrington, 1890); and (3) perturbations to the systemic…”
BackgroundEffects of anesthesia on cerebral blood flow, metabolism, and neuroprotection
Slupe, A. M., & Kirsch, J. R. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18789273 · Cited by 360 · cited 1×
“In addition, the cerebrovasculature is also more efficient at buffering changes in blood pressure associated with the systolic aspect of the cardiac cycle (Burma et al., 2020; Smirl et al., 2018).”
BackgroundReference values for resting blood flow to organs of man
Williams, L. R., & Leggett, R. W. (1989) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/10/3/001 · Cited by 356 · cited 1×
“The brain is one of the most highly perfused organs in the human body; its weight is less than 2% of body mass but it receives 15 to 20% of resting cardiac output (Williams & Leggett, 1989), and hence, high proportion of resting oxygen consumption.”
BackgroundCoverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00285.2014 · Cited by 348 · cited 3×
“…Doppler ultrasound may not represent accurate CBF due to the possibility of the insonated intracranial artery changing in diameter in response to carbon dioxide changes, handgrip exercise, etc (Ainslie & Hoiland, 2014; Coverdale et al., 2014; Hoiland & Ainslie, 2016; Verbree et al., 2014, 2016).”
BackgroundCognitive and Neurologic Outcomes after Coronary-Artery Bypass Surgery
Selnes, O. A., Gottesman, R. F., Grega, M. A., Baumgartner, W. A., Zeger, S. L., & McKhann, G. M. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1100109 · Cited by 347 · cited 1×
“…Lassen was, without question, a modern- day pioneer in the field of cerebrovascular physiology with endless unique contributions to advancing the measurement of CBF as well as the related physiological and pathophysiological implications [reviewed in: (Paulson & Parving, 2007; Severinghaus, 1999)].”
BackgroundVerbree, J., Bronzwaer, A.-S. G. T., Ghariq, E., Versluis, M. J., Daemen, M. J. A. P., van Buchem, M. A., Dahan, A., van Lieshout, J. J., & van Osch, M. J. P. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00651.2014 · Cited by 303 · cited 2×
“…Doppler ultrasound may not represent accurate CBF due to the possibility of the insonated intracranial artery changing in diameter in response to carbon dioxide changes, handgrip exercise, etc (Ainslie & Hoiland, 2014; Coverdale et al., 2014; Hoiland & Ainslie, 2016; Verbree et al., 2014, 2016).”
BackgroundPredicting the Limits of Cerebral Autoregulation During Cardiopulmonary Bypass
Joshi, B., Ono, M., Brown, C., Brady, K., Easley, R. B., Yenokyan, G., Gottesman, R. F., & Hogue, C. W. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31823d292a · Cited by 281
Blood pressure regulation IX: cerebral autoregulation under blood pressure challenges
Tzeng, Y.-C., & Ainslie, P. N. (2014) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2667-y · Cited by 231 · cited 5×
“In contrast, dynamic cerebral autoregulation generally refers to the cerebral pressure– flow relationship as observed during transient changes (over a period of seconds) in mean arterial pressure (Tzeng & Ainslie, 2013) (Figure 3).”
BackgroundInfluentialSelf-citationMicrovascular adaptation in the cerebral cortex of adult spontaneously hypertensive rats.
Harper, S. L., & Bohlen, H. G. (1984) · Hypertension · doi:10.1161/01.hyp.6.3.408 · Cited by 210 · cited 1×
“…experimental data from studies using preclinical models (e.g., cats (Faraci et al., 1987; Kontos et al., 1978; MacKenzie et al., ,1976, 1979), rats (Harper & Bohlen, 1984; Harper et al., 1984; Hernandez et al., 1978; Hoffman et al., 1991; Sadoshima & Heistad, 1983), baboons (Fitch et al., 1976a,…”
MethodAzevedo, E., & Castro, P. (2016) · Manual of Neurosonology · doi:10.1017/cbo9781107447905.023 · Cited by 191
Upper Limit of Autoregulation of Cerebral Blood Flow in the Baboon
Strandgaard, S., MacKenzie, E. T., Sengupta, D., Rowan, J., Lassen, N. A., & Harper, A. M. (1974) · Circulation Research · doi:10.1161/01.res.34.4.435 · Cited by 191
THE RELATIONSHIP BETWEEN THE BLOOD PRESSURE AND THE TONIC REGULATION OF THE PIAL ARTERIES
Fog, M. (1938) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.1.3.187 · Cited by 188 · cited 1×
“Then, in the early 1930s, Fog provided evidence of rapid diameter changes of pial arteries and arterioles induced by changes in arterial pressure in anesthetized cats (Fog, 1938), suggesting the presence of an arterial pressure range wherein autoregulation seemed effective.”
BackgroundTranscranial Doppler ultrasound: Valid, invalid, or both?
Ainslie, P. N., & Hoiland, R. L. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00854.2014 · Cited by 188 · cited 2×
“…Doppler ultrasound may not represent accurate CBF due to the possibility of the insonated intracranial artery changing in diameter in response to carbon dioxide changes, handgrip exercise, etc (Ainslie & Hoiland, 2014; Coverdale et al., 2014; Hoiland & Ainslie, 2016; Verbree et al., 2014, 2016).”
BackgroundSelf-citationMacKenzie, E. T., Farrar, J. K., Fitch, W., Graham, D. I., Gregory, P. C., & Harper, A. M. (1979) · Stroke · doi:10.1161/01.str.10.6.711 · Cited by 178
Arterial and microvascular contributions to cerebral cortical autoregulation in rats
Harper, S. L., Bohlen, H. G., & Rubin, M. J. (1984) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1984.246.1.h17 · Cited by 175 · cited 1×
“…studies using preclinical models (e.g., cats (Faraci et al., 1987; Kontos et al., 1978; MacKenzie et al., ,1976, 1979), rats (Harper & Bohlen, 1984; Harper et al., 1984; Hernandez et al., 1978; Hoffman et al., 1991; Sadoshima & Heistad, 1983), baboons (Fitch et al., 1976a, 1976b; Harper et al.,…”
Joshi, B., Brady, K., Lee, J., Easley, B., Panigrahi, R., Smielewski, P., Czosnyka, M., & Hogue, C. W. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181c6fd12 · Cited by 173 · cited 2×
“However, time spent away from this optimal value is associated with adverse clinical outcomes (Jaeger et al., 2010; Joshi et al., 2010, 2012; Ono et al., 2012; Sekhon et al., 2019; Zeiler et al., 2019), arguing against a wide range of 6 of 11 | BRASSARD et Al. cerebral perfusion pressure/mean…”
BackgroundThomas, K. N., Lewis, N. C. S., Hill, B. G., & Ainslie, P. N. (2015) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00211.2015 · Cited by 167 · cited 1×
“In addition, this limitation could certainly be overcome by simultaneously examining global CBF, by combining volumetric flow (or diameter) in internal carotid artery and vertebral artery utilizing Duplex ultrasound (Hoiland et al., 2020; Smith et al., 2014; Thomas et al., 2015).”
MethodSelf-citationJaeger, M., Dengl, M., Meixensberger, J., & Schuhmann, M. U. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181d45530 · Cited by 164 · cited 1×
“However, time spent away from this optimal value is associated with adverse clinical outcomes (Jaeger et al., 2010; Joshi et al., 2010, 2012; Ono et al., 2012; Sekhon et al., 2019; Zeiler et al., 2019), arguing against a wide range of 6 of 11 | BRASSARD et Al. cerebral perfusion pressure/mean…”
BackgroundRole of tissue hypoxia in local regulation of cerebral microcirculation
Kontos, H. A., Wei, E. P., Raper, A. J., Rosenblum, W. I., Navari, R. M., & Patterson, J. L. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.234.5.h582 · Cited by 160 · cited 1×
“Although not a universal finding, we also appreciate some experimental data from studies using preclinical models (e.g., cats (Faraci et al., 1987; Kontos et al., 1978; MacKenzie et al., ,1976, 1979), rats (Harper & Bohlen, 1984; Harper et al., 1984; Hernandez et al., 1978; Hoffman et al., 1991;…”
ResultCerebral autoregulation and anesthesia
Dagal, A., & Lam, A. M. (2009) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32833020be · Cited by 150 · cited 1×
“This influential concept has been regularly cited since its appearance and has been illustrated in numerous high- impact publications and textbooks (Barrett et al., 2010; Dagal & Lam, 2009; Patel et al., 2019).”
BackgroundCerebrovascular Regulation During Transient Hypotension and Hypertension in Humans
Tzeng, Y., Willie, C. K., Atkinson, G., Lucas, S. J. E., Wong, A., & Ainslie, P. N. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.152066 · Cited by 148 · cited 3×
“…the blood vessels of the brain appear to be more effective at protecting the microcirculation against steady- state and transient increases, compared to decreases, in mean arterial pressure (Aaslid et al., 2007; Brassard et al., 2017; Numan et al., 2014; Panerai et al., 2018; Tzeng et al., 2010).”
BackgroundSelf-citationDefining the characteristic relationship between arterial pressure and cerebral flow
Tan, C. O. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00783.2012 · Cited by 147 · cited 2×
“…healthy and non- anesthetized humans, recent evidence now indicates the range of the mean arterial pressure plateau is considerably smaller (~5– 10 mmHg) than originally proposed where CBF is stable (Tan, 2012; Tan et al., 2013), as compared to the ~90 mmHg range proposed by Lassen (1959).”
BackgroundStatic autoregulation in humans: a review and reanalysis
Numan, T., Bain, A. R., Hoiland, R. L., Smirl, J. D., Lewis, N. C. S., & Ainslie, P. N. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.08.001 · Cited by 145 · cited 11×
“Another important physiological issue related to cerebral autoregulation, which was not taken into consideration in the classic autoregulation curve, is the recently appreciated presence of ‘asymmetry’ in the cerebral autoregulation response (Numan et al., 2014).”
BackgroundMethodResultInfluentialSelf-citationLoss of cerebrovascular autoregulation in experimental meningitis in rabbits.
Tureen, J. H., Dworkin, R. J., Kennedy, S. L., Sachdeva, M., & Sande, M. A. (1990) · Journal of Clinical Investigation · doi:10.1172/jci114475 · Cited by 123 · cited 2×
“…& Heistad, 1983), baboons (Fitch et al., 1976a, 1976b; Harper et al., 1973; Strandgaard et al., ,1974, 1976), monkeys (Heistad et al., 1980), rabbits (Tureen et al., 1990)) broadly support Lassen's interpretation of cerebral autoregulation— providing that the change in arterial pressure is slow.”
BackgroundMiddle cerebral artery diameter changes during rhythmic handgrip exercise in humans
Verbree, J., Bronzwaer, A.-S. G. T., van Buchem, M. A., Daemen, M. J. A. P., LIESHOUT, J. J. V., & van Osch, M. J. P. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16679419 · Cited by 114 · cited 2×
“…Doppler ultrasound may not represent accurate CBF due to the possibility of the insonated intracranial artery changing in diameter in response to carbon dioxide changes, handgrip exercise, etc (Ainslie & Hoiland, 2014; Coverdale et al., 2014; Hoiland & Ainslie, 2016; Verbree et al., 2014, 2016).”
BackgroundAsymmetric Dynamic Cerebral Autoregulatory Response to Cyclic Stimuli
Aaslid, R., Bláha, M., Sviri, G. E., Douville, C., & Newell, D. W. (2007) · Stroke · doi:10.1161/strokeaha.106.473462 · Cited by 110 · cited 4×
“…the blood vessels of the brain appear to be more effective at protecting the microcirculation against steady- state and transient increases, compared to decreases, in mean arterial pressure (Aaslid et al., 2007; Brassard et al., 2017; Numan et al., 2014; Panerai et al., 2018; Tzeng et al., 2010).”
BackgroundInfluentialCerebral Autoregulation in Awake Versus Isoflurane-Anesthetized Rats
Hoffman, W. E., Edelman, G. J., Kochs, E. F., Werner, C. D., Segil, L. J., & Albrecht, R. F. (1991) · Anesthesia & Analgesia · doi:10.1213/00000539-199112000-00013 · Cited by 109 · cited 1×
“…(Faraci et al., 1987; Kontos et al., 1978; MacKenzie et al., ,1976, 1979), rats (Harper & Bohlen, 1984; Harper et al., 1984; Hernandez et al., 1978; Hoffman et al., 1991; Sadoshima & Heistad, 1983), baboons (Fitch et al., 1976a, 1976b; Harper et al., 1973; Strandgaard et al., ,1974, 1976), monkeys…”
On Intra‐Cranial Pressure and the Cerebral Circulation1
Bayliss, W. M., Hill, L., & Gulland, G. L. (1895) · The Journal of Physiology · doi:10.1113/jphysiol.1895.sp000572 · Cited by 100
Blood Pressure and the Brain: How Low Can You Go?
Drummond, J. C. (2019) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004034 · Cited by 99 · cited 1×
“This “classical view” of cerebral autoregulation has since been disputed, challenged for years, and essentially disproven (Drummond, 2019; Heistad & Kontos, 1983; Willie et al., 2014).”
BackgroundThe role of myogenic mechanisms in human cerebrovascular regulation
Tan, C. O., Hamner, J. W., & Taylor, J. A. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.259747 · Cited by 99 · cited 4×
“…healthy and non- anesthetized humans, recent evidence now indicates the range of the mean arterial pressure plateau is considerably smaller (~5– 10 mmHg) than originally proposed where CBF is stable (Tan, 2012; Tan et al., 2013), as compared to the ~90 mmHg range proposed by Lassen (1959).”
BackgroundInfluentialDynamic cerebral autoregulation is attenuated in young fit women
Labrecque, L., Rahimaly, K., Imhoff, S., Paquette, M., Blanc, O. L., Malenfant, S., Drapeau, A., Smirl, J. D., Bailey, D. M., & Brassard, P. (2019) · Physiological Reports · doi:10.14814/phy2.13984 · Cited by 98 · cited 1×
“Several studies focusing on dynamic cerebral autoregulation clearly show CBF can fluctuate tremendously, even if static cerebral autoregulation is unimpaired (in healthy participants) (Aaslid et al., ,1989, 2007; Labrecque et al., 2021, 2017, 2019; Lind- Holst et al., 2011; Tzeng et al., 2010).”
BackgroundSelf-citationEvidence for hysteresis in the cerebral pressure-flow relationship in healthy men
Brassard, P., Ferland‐Dutil, H., Smirl, J. D., Paquette, M., Blanc, O. L., Malenfant, S., & Ainslie, P. N. (2017) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00790.2016 · Cited by 90 · cited 2×
“…the blood vessels of the brain appear to be more effective at protecting the microcirculation against steady- state and transient increases, compared to decreases, in mean arterial pressure (Aaslid et al., 2007; Brassard et al., 2017; Numan et al., 2014; Panerai et al., 2018; Tzeng et al., 2010).”
BackgroundSelf-citationZeiler, F. A., Ercole, A., Cabeleira, M. T., Carbonara, M., Stocchetti, N., Menon, D. K., Smielewski, P. S., Czosnyka, M., Anke, A., Beer, R., et al. (2019) · Journal of Neurotrauma · doi:10.1089/neu.2018.6182 · Cited by 84
Influence of high altitude on cerebral blood flow and fuel utilization during exercise and recovery
Smith, K. J., MacLeod, D. B., Willie, C. K., Lewis, N. C. S., Hoiland, R. L., Ikeda, K., Tymko, M. M., Donnelly, J., Day, T. A., Macleod, N. T., et al. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2014.281212 · Cited by 80 · cited 1×
“In addition, this limitation could certainly be overcome by simultaneously examining global CBF, by combining volumetric flow (or diameter) in internal carotid artery and vertebral artery utilizing Duplex ultrasound (Hoiland et al., 2020; Smith et al., 2014; Thomas et al., 2015).”
MethodSelf-citationLabrecque, L., Rahimaly, K., Imhoff, S., Paquette, M., Blanc, O. L., Malenfant, S., Lucas, S. J. E., Bailey, D. M., Smirl, J. D., & Brassard, P. (2017) · Physiological Reports · doi:10.14814/phy2.13486 · Cited by 77 · cited 1×
“Several studies focusing on dynamic cerebral autoregulation clearly show CBF can fluctuate tremendously, even if static cerebral autoregulation is unimpaired (in healthy participants) (Aaslid et al., ,1989, 2007; Labrecque et al., 2021, 2017, 2019; Lind- Holst et al., 2011; Tzeng et al., 2010).”
BackgroundSelf-citationNitric oxide is fundamental to neurovascular coupling in humans
Hoiland, R. L., Caldwell, H. G., Howe, C. A., Nowak‐Flück, D., Stacey, B. S., Bailey, D. M., Paton, J. F. R., Green, D. J., Sekhon, M. S., Macleod, D. B., et al. (2020) · The Journal of Physiology · doi:10.1113/jp280162 · Cited by 74
Self-citationDynamic cerebral autoregulation across the cardiac cycle during 8 hr of recovery from acute exercise
Burma, J. S., Copeland, P. V., Macaulay, A., Khatra, O., Wright, A. D., & Smirl, J. D. (2020) · Physiological Reports · doi:10.14814/phy2.14367 · Cited by 71 · cited 1×
“In addition, the cerebrovasculature is also more efficient at buffering changes in blood pressure associated with the systolic aspect of the cardiac cycle (Burma et al., 2020; Smirl et al., 2018).”
BackgroundSelf-citationCerebral autoregulation dynamics in endurance-trained individuals
Lind-Holst, M., Cotter, J. D., Helge, J. W., Boushel, R., Augustesen, H., LIESHOUT, J. J. V., & Pott, F. C. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01497.2010 · Cited by 64
Hoiland, R. L., Ainslie, P. N., Wildfong, K. W., Smith, K. J., Bain, A. R., Willie, C. K., Foster, G. E., Monteleone, B., & Day, T. A. (2014) · The Journal of Physiology · doi:10.1113/jphysiol.2014.284521 · Cited by 50 · cited 1×
“Recent experimental work shows conditions such as hypocapnia, hypercapnia, hypoxia, and handgrip exercise can induce changes in vessel diameter, leading to blood flow measurements errors (Coverdale et al., 2014; Hoiland et al., 2015; Mikhail Kellawan et al., 2017; Verbree et al., 2014, 2016).”
BackgroundSelf-citationKellawan, J. M., Harrell, J. W., Roldán‐Alzate, A., Wieben, O. E., & Schrage, W. G. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16659497 · Cited by 47 · cited 1×
“Recent experimental work shows conditions such as hypocapnia, hypercapnia, hypoxia, and handgrip exercise can induce changes in vessel diameter, leading to blood flow measurements errors (Coverdale et al., 2014; Hoiland et al., 2015; Mikhail Kellawan et al., 2017; Verbree et al., 2014, 2016).”
BackgroundDirectional sensitivity of dynamic cerebral autoregulation in squat-stand maneuvers
Panerai, R. B., Barnes, S., Nath, M., Ball, N., Robinson, T. G., & Haunton, V. J. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00010.2018 · Cited by 43 · cited 2×
“…the blood vessels of the brain appear to be more effective at protecting the microcirculation against steady- state and transient increases, compared to decreases, in mean arterial pressure (Aaslid et al., 2007; Brassard et al., 2017; Numan et al., 2014; Panerai et al., 2018; Tzeng et al., 2010).”
BackgroundKalisvaart, A. C. J., Wilkinson, C. M., Gu, S., Kung, T. F. C., Yager, J. Y., Winship, I. R., van Landeghem, F. K. H., & Colbourne, F. (2020) · Scientific Reports · doi:10.1038/s41598-020-78880-4 · Cited by 42
Studies on the cerebral circulation of the baboon in acutely induced hypertension.
Strandgaard, S., MacKenzie, E. T., Jones, J. V., & Harper, A. M. (1976) · Stroke · doi:10.1161/01.str.7.3.287 · Cited by 42
Labrecque, L., Smirl, J. D., & Brassard, P. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00269.2021 · Cited by 40
Self-citationSadoshima, S., & Heistad, D. D. (1983) · Stroke · doi:10.1161/01.str.14.4.575 · Cited by 39 · cited 1×
“…spent away from this optimal value is associated with adverse clinical outcomes (Jaeger et al., 2010; Joshi et al., 2010, 2012; Ono et al., 2012; Sekhon et al., 2019; Zeiler et al., 2019), arguing against a wide range of 6 of 11 | BRASSARD et Al. cerebral perfusion pressure/mean arterial…”
BackgroundLabrecque, L., Drapeau, A., Rahimaly, K., Imhoff, S., & Brassard, P. (2021) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00963.2020 · Cited by 22 · cited 3×
“Several studies focusing on dynamic cerebral autoregulation clearly show CBF can fluctuate tremendously, even if static cerebral autoregulation is unimpaired (in healthy participants) (Aaslid et al., ,1989, 2007; Labrecque et al., 2021, 2017, 2019; Lind- Holst et al., 2011; Tzeng et al., 2010).”
BackgroundSelf-citationAutoregulatory Plateau: Does it Exist?
Rosenblum, W. I. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.20 · Cited by 14 · cited 2×
“…CEREBRAL AUTOREGULATION Since the previous challenge by Heistad & Kontos (1983), accumulating findings continue to confront the Lassen's view of the relationship between mean arterial pressure and CBF and the presence of a wide cerebral autoregulatory plateau remains questioned (Rosenblum, 1995).”
BackgroundTuma, R. F. (2008) · Wiley eBooks · doi:10.1002/cphy.cp020411 · Cited by 9
Cited by
Cerebral blood flow dynamics during cardiac surgery in infants
Leth-Olsen, M., Døhlen, G., Torp, H., & Nyrnes, S. A. (2025) · Pediatric Research · doi:10.1038/s41390-024-03161-z · Cited by 12
Katagiri, A., Fujii, N., Dobashi, K., Lai, Y.-F., Tsuji, B., & Nishiyasu, T. (2024) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00161.2024 · Cited by 4
Metadata
- Authors
- Brassard, P., Labrecque, L., Smirl, J. D., Tymko, M. M., Caldwell, H. G., Hoiland, R. L., Lucas, S. J. E., Denault, A. Y., Couture, E. J., & Ainslie, P. N.
- Venue
- Physiological Reports
- Publisher
- Wiley
- Published
- 2021-07-28
- Volume
- 9
- Issue
- 15
- Pages
- e14982-e14982
- ISSN
- 2051-817X (ISSN-L)
- OpenAlex
- W3184555459
- Cited by
- 177
- References
- 59
- FWCI
- 11.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.