CoChat

Liquid citrate acidification introduces significant glucose bias and leads to misclassification of patients with diabetes

Juricic, Gordana, Kopcinovic, Lara Milevoj, Saracevic, Andrea, Bakliza, Ana, Simundic, Ana-Maria · 2016 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 23

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Glucose measurements are crucial in diabetes diagnosis. We aimed to assess the effectiveness of liquid citrate acidification in preventing glycolysis and investigate glucose stability in serum, sodium fluoride (NaF/KOx) and Glucomedics tubes. Samples from 40 participants were collected in serum, lithium-heparin (LiH), sodium fluoride/potassium oxalate (NaF/KOx) and Glucomedics tubes. Glucose was measured within 60 min (baseline), 120 and 180 min from venipuncture. Serum, NaF/KOx and Glucomedics values at baseline were compared to LiH glucose concentration. Additionally, glucose values measured at 120 and 180 min from each tube were compared with the baseline value. Mean absolute bias for each tube and time point was calculated and compared to recommended criteria. The regression equation obtained comparing citrate to NaF/KOx tubes was used to recalculate glucose results retrieved from the laboratory information system. Glucose measured in Glucomedics was higher (9.9%; p<0.001), while glucose in NaF/KOx and serum was lower compared to LiH (2.4%; p<0.001 and 3.2%; p<0.001, respectively). Biases for all tubes were clinically significant. Glucose remained unchanged at room temperature in all tubes for up to 180 min after venipuncture. Observed bias caused by Glucomedics leads to a 10.6% increase in diabetes prevalence (p<0.001). Inhibition of glycolysis is most effectively achieved using liquid citrate acidification, compared to LiH, NaF/KOx or serum. Due to clinically significant bias relative to reference glucose, the interchangeable use of different tube types for serial glucose measurements is not recommended. The replacement of NaF/KOx with Glucomedics tubes substantially impacts glucose results, giving marked rise in diabetes prevalence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2015-0358

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 23

Metadata

Authors
Juricic, G., Kopcinovic, L. M., Saracevic, A., Bakliza, A., & Simundic, A.-M.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2016-01-01
Volume
54
Issue
2
Pages
363-71
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W786788947
Cited by
23
References
9
FWCI
3.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.