A New Modular Chemiluminescence Immunoassay Analyser Evaluated
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Thyrotropin (TSH), free thyroxine (fT4) and testosterone assays have been used as a probe to evaluate the performances of a new modular chemiluminescence (CL) immunoassay analyser, the Abbott Architect™ i 2000. The evaluation was run in parallel on other systems that use CL as the detection reaction: DPC Immulite®, Chiron Diagnostics ACS-180 and ACS Centaur (TSH functional sensitivity only). TSH functional sensitivity was 0.0012, 0.009, 0.033 and 0.039 mU/l for the Architect, Immulite, ACS Centaur and ACS-180, respectively. Testosterone functional sensitivity was 0.38, 3.7 and 2.0 nmol/l for Architect, Immulite and ACS-180, respectively. Good correlation was obtained between the ACS-180 and Architect for all assays. The Immulite correlation did not agree well with the Architect or ACS-180 for fT4 and testosterone but was in good agreement for TSH. Regarding fT4 and testosterone, equilibrium dialysis and isotopic dilution gas-chromatography mass-spectrometry (GC-MS) respectively were used as reference methods. For both within- and between-run precision, the Architect showed the best reproducibility for all three analytes (CV < 6%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Direct determination of free thyroxin in undiluted serum by equilibrium dialysis/radioimmunoassay.
Nelson, J. C., & Tomei, R. T. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.9.1733 · Cited by 128
Cited by
Dumesic, D. A., Oberfield, S. E., Stener-Victorin, E., Marshall, J. C., Laven, J. S., & Legro, R. S. (2015) · Endocrine Reviews · doi:10.1210/er.2015-1018 · Cited by 1,020
Taieb, J., Mathian, B., Millot, F., Patricot, M.-C., Mathieu, E., Queyrel, N., Lacroix, I., Somma-Delpero, C., & Boudou, P. (2003) · Clinical Chemistry · doi:10.1373/49.8.1381 · Cited by 640
Escobar-Morreale, H. F., Carmina, E., Dewailly, D., Gambineri, A., Kelestimur, F., Moghetti, P., Pugeat, M., Qiao, J., Wijeyaratne, C. N., Witchel, S. F., et al. (2012) · Human Reproduction Update · doi:10.1093/humupd/dmr042 · Cited by 494
“Nevertheless, some total testosterone immunochemiluminescence assays provide reliable values with functional sensitivities similar to that of LC/MS-based methods (Ognibene et al., 2000; Kushnir et al., 2010).”
Almeida, O. P., Waterreus, A., Spry, N., Flicker, L., & Martins, R. N. (2004) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2003.11.002 · Cited by 255
Murphy, E., Glüer, C. C., Reid, D. M., Felsenberg, D., Roux, C., Eastell, R., & Williams, G. R. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-2630 · Cited by 180
Metadata
- Authors
- Ognibene, A., Drake, C. J., Jeng, K.-Y. S., Pascucci, T. E., Hsu, S., Luceri, F., & Messeri, G.
- Venue
- cclm
- Publisher
- Walter de Gruyter GmbH
- Published
- 2000-03-25
- Volume
- 38
- Issue
- 3
- Pages
- 251-260
- ISSN
- 1434-6621 (ISSN-L)
- OpenAlex
- W2083195745
- Cited by
- 30
- References
- 2
- FWCI
- 1.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.