CoChat

A New Modular Chemiluminescence Immunoassay Analyser Evaluated

Ognibene, Agostino, Drake, Christopher J., Jeng, Kwan-Yee S., Pascucci, Terri E., Hsu, Stephen, Luceri, Francesca, Messeri, Gianni · 2000 · cclm
Cited by 30

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Thyrotropin (TSH), free thyroxine (fT4) and testosterone assays have been used as a probe to evaluate the performances of a new modular chemiluminescence (CL) immunoassay analyser, the Abbott Architect™ i 2000. The evaluation was run in parallel on other systems that use CL as the detection reaction: DPC Immulite®, Chiron Diagnostics ACS-180 and ACS Centaur (TSH functional sensitivity only). TSH functional sensitivity was 0.0012, 0.009, 0.033 and 0.039 mU/l for the Architect, Immulite, ACS Centaur and ACS-180, respectively. Testosterone functional sensitivity was 0.38, 3.7 and 2.0 nmol/l for Architect, Immulite and ACS-180, respectively. Good correlation was obtained between the ACS-180 and Architect for all assays. The Immulite correlation did not agree well with the Architect or ACS-180 for fT4 and testosterone but was in good agreement for TSH. Regarding fT4 and testosterone, equilibrium dialysis and isotopic dilution gas-chromatography mass-spectrometry (GC-MS) respectively were used as reference methods. For both within- and between-run precision, the Architect showed the best reproducibility for all three analytes (CV < 6%).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm.2000.037

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Ognibene, A., Drake, C. J., Jeng, K.-Y. S., Pascucci, T. E., Hsu, S., Luceri, F., & Messeri, G.
Venue
cclm
Published
2000-03-25
Volume
38
Issue
3
Pages
251-260
ISSN
1434-6621 (ISSN-L)
OpenAlex
W2083195745
Cited by
30
References
2
FWCI
1.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.