Methods for Addressing Technology-induced Errors: The Current State
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Summary: Objectives: The objectives of this paper are to review and discuss the methods that are being used internationally to report on, mitigate, and eliminate technology-induced errors. Methods: The IMIA Working Group for Health Informatics for Patient Safety worked together to review and synthesize some of the main methods and approaches associated with technology-induced error reporting, reduction, and mitigation. The work involved a review of the evidence-based literature as well as guideline publications specific to health informatics. Results: The paper presents a rich overview of current approaches, issues, and methods associated with: (1) safe HIT design, (2) safe HIT implementation, (3) reporting on technology-induced errors, (4) technology-induced error analysis, and (5) health information technology (HIT) risk management. The work is based on research from around the world. Conclusions: Internationally, researchers have been developing methods that can be used to identify, report on, mitigate, and eliminate technology-induced errors. Although there remain issues and challenges associated with the methodologies, they have been shown to improve the quality and safety of HIT. Since the first publications documenting technology-induced errors in healthcare in 2005, we have seen in a short 10 years researchers develop ways of identifying and addressing these types of errors. We have also seen organizations begin to use these approaches. Knowledge has been translated into practice in a short ten years whereas the norm for other research areas is of 20 years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Role of Computerized Physician Order Entry Systems in Facilitating Medication Errors
Koppel, R. (2005) · JAMA · doi:10.1001/jama.293.10.1197 · Cited by 2,126
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Engineering a Safer World: Systems Thinking Applied to Safety
(2012) · Choice Reviews Online · doi:10.5860/choice.49-6305 · Cited by 1,566
Engineering a Safer World: Systems Thinking Applied to Safety
Leveson, N. G. (2012) · doi:10.7551/mitpress/8179.001.0001 · Cited by 1,077
User involvement: A review of the benefits and challenges
Kujala, S. (2003) · Behaviour & Information Technology · doi:10.1080/01449290301782 · Cited by 943 · cited 1×
“This is reflective of the research that has shown that greater user involvement in design (including use of PD) leads to improved quality of systems and fewer errors from more accurate user requirements [38].”
Sittig, D. F., & Singh, H. (2010) · Quality and Safety in Health Care · doi:10.1136/qshc.2010.042085 · Cited by 897 · cited 1×
“For example, Sittig et al. [86] developed guides for the Office of the National Coordi-nator (ONC) to help healthcare organizations self-evaluate safety and safe use of EHRs.”
Harrison, M. I., Koppel, R., & Bar-Lev, S. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2384 · Cited by 691
Health IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
Health information technology: fallacies and sober realities
Karsh, B.-T., Weinger, M. B., Abbott, P. A., & Wears, R. L. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005637 · Cited by 365 · cited 1×
“Poorly implemented HIT has the potential to lead to large scale errors, particularly in complex situations and contexts [59].”
Categorizing the unintended sociotechnical consequences of computerized provider order entry
Ash, J. S., Sittig, D. F., Dykstra, R. H., Guappone, K., Carpenter, J. D., & Seshadri, V. (2007) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2006.05.017 · Cited by 267 · cited 1×
“In particular, they proposed that systems (including their technological and non-technological components) must be considered as dynamically evolving processes with mutual control influence and feedback [74,75] [79].”
Zahabi, M., Kaber, D. B., & Swangnetr, M. (2015) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720815576827 · Cited by 240
Comprehensive Analysis of a Medication Dosing Error Related to CPOE: Table 1
Horsky, J., Kuperman, G. J., & Patel, V. L. (2005) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1740 · Cited by 197 · cited 1×
“’s Multifaceted Cognitive Methodology for Characterizing Cognitive Demands of Systems [85].”
Using FDA reports to inform a classification for health information technology safety problems
Magrabi, F., Ong, M.-S., Runciman, W., & Coiera, E. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000369 · Cited by 193 · cited 6×
“The number of advances in HIT safety research has been significant since the first documented reports on technology-induced errors in healthcare in 2005 [2-8].”
InfluentialMagrabi, F., Baker, M., Sinha, I., Ong, M.-S., Harrison, S., Kidd, M. R., Runciman, W. B., & Coiera, E. (2015) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2014.12.003 · Cited by 100
Saleem, J. J., Russ, A. L., Sanderson, P., Johnson, T. R., Zhang, J., & Sittig, D. F. (2009) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638638 · Cited by 72 · cited 1×
“Individual issues such as usability issues (e.g. inability to find a field for data entry), or poor task-technology fit between the team and the HIT can lead to technology-induced errors at the team level [64-67].”
Cited by
Powers, E. M., Shiffman, R. N., Melnick, E. R., Hickner, A., & Sharifi, M. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy112 · Cited by 128
Systematic review of computerized prescriber order entry and clinical decision support
Vélez-Díaz-Pallarés, M., Pérez-Menéndez-Conde, C., & Bermejo-Vicedo, T. (2018) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp170870 · Cited by 50
Health technology, quality and safety in a learning health system
Borycki, E. M., & Kushniruk, A. W. (2023) · Healthcare Management Forum · doi:10.1177/08404704221139383 · Cited by 23
Self-citationCopy and paste in the electronic medical record: A scoping review
(2021) · Knowledge Management & E-Learning: An International Journal · doi:10.34105/j.kmel.2021.13.028 · Cited by 5
Self-citation
Metadata
- Authors
- Dexheimer, J. W., Cossio, C. H. L., Gong, Y., Jensen, S., Kaipio, J., Kennebeck, S., Kirkendall, E., Kushniruk, A. W., Kuziemsky, C., Marcilly, R., Röhrig, R., Saranto, K., Senathirajah, Y., Weber, J., Takeda, H., & Borycki, E.
- Venue
- Yearbook of Medical Informatics
- Publisher
- Georg Thieme Verlag KG
- Published
- 2016-08
- Volume
- 25
- Issue
- 01
- Pages
- 30-40
- ISSN
- 0943-4747 (ISSN-L)
- 2364-0502
- OpenAlex
- W2555099283
- Cited by
- 26
- References
- 15
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.