Human distal sciatic nerve fascicular anatomy: Implications for ankle control using nerve-cuff electrodes
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The design of neural prostheses to restore standing balance, prevent foot drop, or provide active propulsion during ambulation requires detailed knowledge of the distal sciatic nerve anatomy. Three complete sciatic nerves and branches were dissected from the piriformis to each muscle entry point to characterize the branching patterns and diameters. Fascicle maps were created from serial sections of each distal terminus below the knee through the anastomosis of the tibial and common fibular nerves above the knee. Similar branching patterns and fascicle maps were observed across specimens. Fascicles innervating primary plantar flexors, dorsiflexors, invertors, and evertors were distinctly separate and functionally organized in the proximal tibial, common fibular, and distal sciatic nerves; however, fascicles from individual muscles were not apparent at these levels. The fascicular organization is conducive to selective stimulation for isolated and/or balanced dorsiflexion, plantar flexion, eversion, and inversion through a single multicontact nerve-cuff electrode. These neuroanatomical data are being used to design nerve-cuff electrodes for selective control of ankle movement and improve current lower-limb neural prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man
Haugland, M. K., & Sinkjaer, T. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481970 · Cited by 168
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156 · cited 1×
“Nerve-cuff placement as far distally as possible ensures the best muscle activation selectivity; however, locations below the knee may have complications caused by lead wires crossing the joint [30].”
BackgroundSchiefer, M. A., Triolo, R. J., & Tyler, D. J. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.918425 · Cited by 148 · cited 2×
“Modeling and simulation studies based on the detailed femoral fascicular anatomy [22] have been successfully employed to design and optimize implantable femoral nerve-cuff electrodes [16].”
MethodSelf-citationQuantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130 · cited 2×
“This model-driven approach to designing selective electrodes for the femoral nerve has been verified intraoperatively [23], and the resulting devices have been approved for human feasibility trials [24].”
BackgroundMethodSelf-citationSelectivity of multiple-contact nerve cuff electrodes: a simulation analysis
Choi, A. Q., Cavanaugh, J. K., & Durand, D. M. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909637 · Cited by 121
Gustafson, K. J., Pinault, G. C. J., Neville, J. J., Syed, I., Jr, J. A. D., Jean-Claude, J., & Triolo, R. J. (2009) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2008.08.0097 · Cited by 107
Self-citation
Cited by
Lower extremity regional anesthesia: essentials of our current understanding
Tran, D. Q., Salinas, F. V., Benzon, H. T., & Neal, J. M. (2019) · Regional Anesthesia & Pain Medicine · doi:10.1136/rapm-2018-000019 · Cited by 314
Wang, J., Xiong, H., Zhu, T., Liu, Y., Pan, H., Fan, C., Zhao, X., & Lu, W. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c03570 · Cited by 198
Schiefer, M. A., Freeberg, M., Pinault, G. J. C., Anderson, J., Hoyen, H., Tyler, D. J., & Triolo, R. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056006 · Cited by 57
“Anatomical characteristics of the tibial, common peroneal, and femoral nerves at the level where the FINE was tested [47, 64].”
BackgroundInfluentialSelf-citationThe design of and chronic tissue response to a composite nerve electrode with patterned stiffness
Freeberg, M. J., Stone, M. A., Triolo, R. J., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6632 · Cited by 54
Self-citationSchiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012) · Journal of Computational Neuroscience · doi:10.1007/s10827-011-0381-5 · Cited by 53
Self-citation
Metadata
- Authors
- Gustafson, K. J., Grinberg, Y., Joseph, S., & Triolo, R. J.
- Venue
- The Journal of Rehabilitation Research and Development
- Published
- 2012
- Volume
- 49
- Issue
- 2
- Pages
- 309
- ISSN
- 0742-3241 (ISSN-L)
- 0748-7711
- OpenAlex
- W2045539717
- Cited by
- 59
- References
- 9
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.