CoChat

Urine miR-21-5p as a potential non-invasive biomarker for gastric cancer

Open access
Kao, Hsiao-Wei, Pan, Chao-Yu, Lai, Chun-Hung, Wu, Chew-Wun, Fang, Wen-Liang, Huang, Kuo-Hung, Lin, Wen-Chang · 2017 · Oncotarget
Cited by 65

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Abstract

// Hsiao-Wei Kao 1, * , Chao-Yu Pan 1, 2, * , Chun-Hung Lai 1 , Chew-Wun Wu 3 , Wen-Liang Fang 3 , Kuo-Hung Huang 3 and Wen-Chang Lin 1, 2 1 Institute of Biomedical Sciences, Academia Sinica, Taipei, Taiwan 2 Institute of Biomedical Informatics, National Yang-Ming University, Taipei, Taiwan 3 Department of Surgery, Veterans General Hospital and National Yang-Ming University, Taipei, Taiwan * These authors have contributed equally to this work Correspondence to: Wen-Chang Lin, email: wenlin@ibms.sinica.edu.tw Keywords: microRNA, liquid biopsy, urine samples, gastric cancer Received: December 08, 2016 Accepted: March 14, 2017 Published: April 07, 2017 ABSTRACT Many reports have implicated that microRNAs involve in cancer development and progression, such as miR-155 in breast cancers and miR-196 in gastric cancers. Furthermore, microRNAs are more stable than typical protein-coding gene mRNAs in varieties of clinical samples including body fluids. This suggests that they are potentially valuable biomarkers for cancer monitoring. In this study, we have used urine samples of gastric cancer patients to demonstrate the feasibility of urine microRNAs for gastric cancer detection. Urine samples of gastric cancer patients were extracted for total RNA, which were examined for the expression of miR-21-5p using quantitative stem-loop PCR. Our results demonstrated that miR-21-5p could be detected in small amounts of urine samples with good stability, and the expression levels of miR-21-5p were reduced following surgical removal of gastric cancer tissues. These results implicate that urine miR-21-5p could be utilized as a novel non-invasive biomarker of gastric cancer detection and monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.18632/oncotarget.16916

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 65

Metadata

Authors
Kao, H.-W., Pan, C.-Y., Lai, C.-H., Wu, C.-W., Fang, W.-L., Huang, K.-H., & Lin, W.-C.
Venue
Oncotarget
Published
2017-04-07
Volume
8
Issue
34
Pages
56389-56397
ISSN
1949-2553 (ISSN-L)
OpenAlex
W2604974376
Cited by
63
References
55
FWCI
2.13
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.