Results of a second attempt at surgical repair of a failed initial rotator-cuff repair.
The DOI matches its Crossref record.
Abstract
Twenty-seven patients with twenty-seven involved shoulders underwent a second attempt at repair of an initial rotator-cuff repair that had failed. Factors associated with the failure of the initial repair included a massive or large tendon tear, damage to the deltoid origin at the original surgery, and possibly inadequate postoperative external support. Seven patients required a third operation because of continuing pain or weakness. The remaining twenty patients were followed for a minimum of two years (average, forty-eight months) and seventeen of them were examined at an average of forty-six months (range, twenty-six to 118 months) after surgery. Postoperatively, although seventeen patients (63 per cent) still had moderate or severe pain, sixteen (76 per cent) of the twenty-one patients who were operated on to relieve pain reported that the pain was substantially diminished. Active abduction increased an average of 8 degrees, but only seven shoulders gained more than 30 degrees of active abduction. Nineteen shoulders remained moderately or markedly weak in abduction. Over-all, four patients (17 per cent) had a good result; six (25 per cent), a fair result; and fourteen (58 per cent), a poor result. These results suggest that the surgeon should be quite hesitant to propose a second attempt at rotator cuff repair to a patient, as although pain may be diminished, active movement is unlikely to improve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145
Castricini, R., Longo, U. G., De Benedetto, M., Panfoli, N., Pirani, P., Zini, R., Maffulli, N., & Denaro, V. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510390780 · Cited by 487
Novel Nanofiber-Based Scaffold for Rotator Cuff Repair and Augmentation
Moffat, K. L., Kwei, A. S.-P., Spalazzi, J. P., Doty, S. B., Levine, W. N., & Lu, H. H. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0014 · Cited by 307
Cole, B. J., McCarty, L. P., Kang, R. W., Alford, W., Lewis, P. B., & Hayden, J. K. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2006.12.011 · Cited by 303
Sclamberg, S. G., Tibone, J. E., Itamura, J. M., & Kasraeian, S. (2004) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2004.03.005 · Cited by 284
Dejardin, L. M., Arnoczky, S. P., Ewers, B. J., Haut, R. C., & Clarke, R. B. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290021001 · Cited by 276
All-arthroscopic versus mini-open rotator cuff repair: A long-term retrospective outcome comparison
Severud, E. L., Ruotolo, C., Abbott, D. D., & Nottage, W. M. (2003) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2003.50036 · Cited by 248
Rotator Cuff Repair Using an Acellular Dermal Matrix Graft: An In Vivo Study in a Canine Model
Adams, J. E., Zobitz, M. E., Reach, J. S., An, K.-N., & Steinmann, S. P. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.03.016 · Cited by 248
Lee, B. G., Cho, N. S., & Rhee, Y. G. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.07.012 · Cited by 233
Does Platelet-Rich Plasma Accelerate Recovery After Rotator Cuff Repair? A Prospective Cohort Study
Jo, C. H., Kim, J. E., Yoon, K. S., Lee, J. H., Kang, S. B., Lee, J. H., Han, H. S., Rhee, S. H., & Shin, S. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511413454 · Cited by 229
Autologous platelet rich plasma for arthroscopic rotator cuff repair. A pilot study
Randelli, P. S., Arrigoni, P., Cabitza, P., Volpi, P., & Maffulli, N. (2008) · Disability and Rehabilitation · doi:10.1080/09638280801906081 · Cited by 214
“The dimensions of the lesion were measured with an arthroscopic millimetred caliber and recorded according to DeOrio and Cofield’s classification as less than 1 cm (small), from 1–3 cm (medium), 3–5 cm (large), and greater than 5 cm (massive) in the antero-posterior diameter [22].”
MethodLo, I. K. Y., Marchuk, L. L., Hollinshead, R., Hart, D. A., & Frank, C. B. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262200 · Cited by 201
“4 cm, with 2 medium, 5 large, and 3 massive rotator cuff tears.(15) All tears were completely repairable.”
BackgroundMR Imaging of Rotator Cuff Injury: What the Clinician Needs to Know
Morag, Y., Jacobson, J. A., Miller, B., De Maeseneer, M., Girish, G., & Jamadar, D. (2006) · RadioGraphics · doi:10.1148/rg.264055087 · Cited by 179
“DeOrio and Cofield (40) classified rotator cuff tears on the basis of greatest dimension as either small ( 1 cm), medium (1–3 cm), large (3–5 cm), or massive ( 5 cm) (Fig 4).”
BackgroundSlabaugh, M. A., Nho, S. J., Grumet, R. C., Wilson, J. B., Seroyer, S. T., Frank, R. M., Romeo, A. A., Provencher, M. T., & Verma, N. N. (2010) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2009.07.023 · Cited by 177
Rotator Cuff Disease: Treatment Options and Considerations
Dang, A., & Davies, M. (2018) · Sports Medicine and Arthroscopy Review · doi:10.1097/jsa.0000000000000207 · Cited by 177
Kim, Y. S., Sung, C. H., Chung, S. H., Kwak, S. J., & Koh, Y. G. (2017) · The American Journal of Sports Medicine · doi:10.1177/0363546517702863 · Cited by 176
Shoulder Strength in Asymptomatic Individuals with Intact Compared with Torn Rotator Cuffs
Kim, H. M., Teefey, S. A., Zelig, A., Galatz, L. M., Keener, J. D., & Yamaguchi, K. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.h.00219 · Cited by 168
Long-Term Outcome of Arthroscopic Massive Rotator Cuff Repair: The Importance of Double-Row Fixation
Denard, P. J., Jiwani, A. Z., Lädermann, A., & Burkhart, S. S. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.12.007 · Cited by 165
Schlegel, T. F., Hawkins, R. J., Lewis, C. W., Motta, T., & Turner, A. S. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505279912 · Cited by 126
“This failure rate has been reported to be between 38% and 65% in primary repairs.(3,5-8,10,11,15,16) The failure of rotator cuff repairs can be attributed to many factors.”
Metadata
- Authors
- DeOrio, J. K., & Cofield, R. H.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1984-04
- Volume
- 66
- Issue
- 4
- Pages
- 563-567
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1946386259
- Cited by
- 919
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.