CortiWatch: Watch-Based Cortisol Tracker
Open accessAbstract
Sweat-based analytics have recently caught the attention of researchers and medical professionals alike because they do not require professionally trained personnel or invasive collection techniques to obtain a sample.The following presents a small form-factor biosensor for reporting physiological ranges of cortisol present in ambient sweat (8-151 ng/ml).This device obtains cortisol measurements through low volumes of unstimulated sweat from the user's wrist.We designed a potentiostatic circuit on a printed circuit board to perform electrochemical testing techniques.The detection modality developed for quantifying sensor response to varying cortisol concentrations is a current based electrochemical technique, chronoamperometry (CA).From the results, the sensor can detect cortisol in the physiologically relevant ranges of cortisol; thus, the sensor is a noninvasive, label free, cost-effective solution for tracking cortisol levels for circadian diagnostics.Lay abstract: Cortisol, typically referred to as the 'stress hormone', plays a large role in typical body function.Cortisol matches the human sleep cycle, provides alertness, and is excreted by the adrenal cortex.The adrenal cortex is responsible for some of the body's hormonal secretions and can malfunction or fail with age or due to an autoimmune disorder.Our group has developed a wrist worn biosensor to monitor cortisol noninvasively with low volumes of sweat.The required sample is of low volume that no exercise or physical exertion is required for collection.The device allows researchers and users alike to determine cortisol concentration and thus monitor adrenal gland functionality.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Electrochemical Methods: Fundamentals and Applications
Bard, A. J., & Faulkner, L. R. (1980) · Cited by 22,436 · see citing works
Electrochemical Methods: Fundamentals and Applications
de Rooij, M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,115 · see citing works
The HPA axis in major depression: classical theories and new developments
Pariante, C. M., & Lightman, S. L. (2008) · Trends in Neurosciences · doi:10.1016/j.tins.2008.06.006 · Cited by 2,009 · see citing works
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486 · see citing works
Pruessner, J. C., Wolf, O. T., Hellhammer, D. H., Buske-Kirschbaum, A., von Auer, K., Jobst, S., Kaspers, F., & Kirschbaum, C. (1997) · Life Sciences · doi:10.1016/s0024-3205(97)01008-4 · Cited by 1,450 · see citing works
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,197 · see citing works
Assessment of the cortisol awakening response: Expert consensus guidelines
Stalder, T., Kirschbaum, C., Kudielka, B. M., Adam, E. K., Pruessner, J. C., Wüst, S., Dockray, S., Smyth, N., Evans, P., Hellhammer, D. H., et al. (2016) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2015.10.010 · Cited by 967 · see citing works
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724 · see citing works
Antibodies and antibody-derived analytical biosensors
Sharma, S., Byrne, H., & O’Kennedy, R. J. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150002 · Cited by 397 · see citing works
Gozansky, W. S., Lynn, J. S., Laudenslager, M. L., & Kohrt, W. M. (2005) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2005.02349.x · Cited by 356 · see citing works
Portable biosensor for monitoring cortisol in low-volume perspired human sweat
Kinnamon, D., Ghanta, R., Lin, K.-C., Muthukumar, S., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-13684-7 · Cited by 231 · see citing works
Self-citationShift Work at Young Age Is Associated with Elevated Long-Term Cortisol Levels and Body Mass Index
Manenschijn, L., van Kruysbergen, R., de Jong, F. H., Koper, J. W., & van Rossum, E. F. C. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2011-1551 · Cited by 209 · see citing works
Sanghavi, B. J., Moore, J. A., Chávez, J. L., Hagen, J. A., Kelley‐Loughnane, N., Chou, C., & Swami, N. S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.044 · Cited by 188 · see citing works
A low-cost miniaturized potentiostat for point-of-care diagnosis
Cruz, A. F. D., Norena, N., Kaushik, A. K., & Bhansali, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.06.053 · Cited by 164 · see citing works
Vabbina, P. K., Kaushik, A. K., Pokhrel, N., Bhansali, S., & Pala, N. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.026 · Cited by 155 · see citing works
Munje, R. D., Muthukumar, S., Jagannath, B., & Prasad, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-02133-0 · Cited by 149 · see citing works
Self-citationTuteja, S., Ormsby, C., & Neethirajan, S. (2018) · Nano-Micro Letters · doi:10.1007/s40820-018-0193-5 · Cited by 119 · see citing works
TiCxOy thin films for decorative applications: Tribocorrosion mechanisms and synergism
Mathew, M. T., Ariza, E., Rocha, L. A., Fernandes, A. C., & Vaz, F. (2008) · Tribology International · doi:10.1016/j.triboint.2007.11.011 · Cited by 101 · see citing works
Human perspiration measurement
Ohhashi, T., Sakaguchi, M., & Tsuda, T. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/4/001 · Cited by 68 · see citing works
Cardiac troponin biosensors: where are we now?
Upasham, S., Tanak, A. S., & Prasad, S. (2018) · Advanced Health Care Technologies · doi:10.2147/ahct.s138543 · Cited by 52 · see citing works
Self-citationDevelopment of ultra-low volume, multi-bio fluid, cortisol sensing platform
Upasham, S., Tanak, A., Jagannath, B., & Prasad, S. (2018) · Scientific Reports · doi:10.1038/s41598-018-35199-5 · Cited by 50 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 4
- [5]Krieger DT Brief introduction to Cushing's syndrome and disease BT – Cushing's syndrome. Krieger DT ()., Springer, Berlin, Heidelberg, Germany, 1– 4 (1982).
- [18]Muthukumar S, Jagannath B, Prasad S A new paradigm in sweat based wearable diagnostics biosensors using room temperature ionic liquids (RTILs). Sci. Rep. 7, 1950 (2017). 28512341 PMC5434046
- [20]Plieth W Electrochemistry for materials science. Elsevier, Amsterdam, The Netherlands (2008).
- [21]Upasham S, Tanak A, Jagannath B, Prasad S Development of ultra-low volume, multi-bio fluid, cortisol sensing platform. Sci. Rep. 8(1), 16745 (2018). 30425312 PMC6233171
Cited by
Sorted by citations
Stress Monitoring and Recent Advancements in Wearable Biosensors
Samson, C., & Koh, A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.01037 · Cited by 129 · see citing works
Phatak, A. A., Wieland, F.-G., Vempala, K., Volkmar, F., & Memmert, D. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00372-0 · Cited by 74 · see citing works
Portable and wearable real-time stress monitoring: A critical review
Parlak, O. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100036 · Cited by 60 · see citing works
Shajari, S., Salahandish, R., Zare, A., Hassani, M., Moossavi, S., Munro, E., Rashid, R., Rosenegger, D., Bains, J. S., & Sanati Nezhad, A. (2023) · Advanced Science · doi:10.1002/advs.202204171 · Cited by 55 · see citing works
- Authors
- Rice, P., Upasham, S., Jagannath, B., Manuel, R., Pali, M., & Prasad, S.
- Affiliations
- The University of Texas at Dallas (US)
- Corresponding author
- Prasad, Shalini
- Venue
- Future Science OA
- Publisher
- Informa UK Limited
- Published
- 2019-09-26
- Volume
- 5
- Issue
- 9
- Pages
- FSO416-FSO416
- ISSN
- 2056-5623 (ISSN-L)
- PMC
- PMC6787562
- OpenAlex
- W2976547375
- Cited by
- 63
- References
- 21
- Citations by year
- 2026: 8 · 2025: 5 · 2024: 10 · 2023: 11 · 2022: 11 · 2021: 10 · 2020: 7 · 2018: 1
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Future Science OA (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- wrist-worn sensors, chronoamperometry, electrochemical detection, printed circuit boards, circadian rhythm, adrenal function, wearable health monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review