Cited by 63Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAdvanced biosensing and bioanalysis techniques

CortiWatch: Watch-Based Cortisol Tracker

Open access
Rice, Paul, Upasham, Sayali, Jagannath, Badrinath, Manuel, Roshan, Pali, Madhavi, Prasad, Shalini·2019·Future Science OA

Abstract

Sweat-based analytics have recently caught the attention of researchers and medical professionals alike because they do not require professionally trained personnel or invasive collection techniques to obtain a sample.The following presents a small form-factor biosensor for reporting physiological ranges of cortisol present in ambient sweat (8-151 ng/ml).This device obtains cortisol measurements through low volumes of unstimulated sweat from the user's wrist.We designed a potentiostatic circuit on a printed circuit board to perform electrochemical testing techniques.The detection modality developed for quantifying sensor response to varying cortisol concentrations is a current based electrochemical technique, chronoamperometry (CA).From the results, the sensor can detect cortisol in the physiologically relevant ranges of cortisol; thus, the sensor is a noninvasive, label free, cost-effective solution for tracking cortisol levels for circadian diagnostics.Lay abstract: Cortisol, typically referred to as the 'stress hormone', plays a large role in typical body function.Cortisol matches the human sleep cycle, provides alertness, and is excreted by the adrenal cortex.The adrenal cortex is responsible for some of the body's hormonal secretions and can malfunction or fail with age or due to an autoimmune disorder.Our group has developed a wrist worn biosensor to monitor cortisol noninvasively with low volumes of sweat.The required sample is of low volume that no exercise or physical exertion is required for collection.The device allows researchers and users alike to determine cortisol concentration and thus monitor adrenal gland functionality.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2144/fsoa-2019-0061

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. [5]Krieger DT Brief introduction to Cushing's syndrome and disease BT – Cushing's syndrome. Krieger DT ()., Springer, Berlin, Heidelberg, Germany, 1– 4 (1982).
  2. [18]Muthukumar S, Jagannath B, Prasad S A new paradigm in sweat based wearable diagnostics biosensors using room temperature ionic liquids (RTILs). Sci. Rep. 7, 1950 (2017). 28512341 PMC5434046
  3. [20]Plieth W Electrochemistry for materials science. Elsevier, Amsterdam, The Netherlands (2008).
  4. [21]Upasham S, Tanak A, Jagannath B, Prasad S Development of ultra-low volume, multi-bio fluid, cortisol sensing platform. Sci. Rep. 8(1), 16745 (2018). 30425312 PMC6233171

Cited by

Sorted by citations

Authors
Rice, P., Upasham, S., Jagannath, B., Manuel, R., Pali, M., & Prasad, S.
Affiliations
The University of Texas at Dallas (US)
Corresponding author
Prasad, Shalini
Venue
Future Science OA
Published
2019-09-26
Volume
5
Issue
9
Pages
FSO416-FSO416
ISSN
2056-5623 (ISSN-L)
OpenAlex
W2976547375
Cited by
63
References
21
Citations by year
2026: 8 · 2025: 5 · 2024: 10 · 2023: 11 · 2022: 11 · 2021: 10 · 2020: 7 · 2018: 1
FWCI
2.52
Type
journal article
Language
en
Open access
Locations
  • Future Science OA (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
wrist-worn sensors, chronoamperometry, electrochemical detection, printed circuit boards, circadian rhythm, adrenal function, wearable health monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review