Using failure mode and effects analysis to plan implementation of smart i.v. pump technology
The DOI matches its Crossref record; 33 of the 35 references it cites were found in a registry or an index.
Abstract
PURPOSE: Failure mode and effects analysis (FMEA) was used to evaluate a smart i.v. pump as it was implemented into a redesigned medication-use process. SUMMARY: A multidisciplinary team conducted a FMEA to guide the implementation of a smart i.v. pump that was designed to prevent pump programming errors. The smart i.v. pump was equipped with a dose-error reduction system that included a pre-defined drug library in which dosage limits were set for each medication. Monitoring for potential failures and errors occurred for three months postimplementation of FMEA. Specific measures were used to determine the success of the actions that were implemented as a result of the FMEA. The FMEA process at the hospital identified key failure modes in the medication process with the use of the old and new pumps, and actions were taken to avoid errors and adverse events. I.V. pump software and hardware design changes were also recommended. Thirteen of the 18 failure modes reported in practice after pump implementation had been identified by the team. A beneficial outcome of FMEA was the development of a multidisciplinary team that provided the infrastructure for safe technology implementation and effective event investigation after implementation. With the continual updating of i.v. pump software and hardware after implementation, FMEA can be an important starting place for safe technology choice and implementation and can produce site experts to follow technology and process changes over time. CONCLUSION: FMEA was useful in identifying potential problems in the medication-use process with the implementation of new smart i.v. pumps. Monitoring for system failures and errors after implementation remains necessary.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
To Err Is Human: Building a Safer Health System
(2000) · National Academies Press eBooks · doi:10.17226/9728 · Cited by 14,044
Wall, A. (2000) · British Journal of Healthcare Management · doi:10.12968/bjhc.2000.6.9.19311 · Cited by 5,903
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127 · cited 1×
“medication administration is especially vulnerable due to the lack of built-in double checks and the low likelihood of event interception before the drug reaches the patient.(1,6) In a systems analysis of error, misuse of infusion pumps and other parenteral delivery systems was identified as a common proximal cause of…”
BackgroundMedication Errors and Adverse Drug Events in Pediatric Inpatients
Kaushal, R. (2001) · JAMA · doi:10.1001/jama.285.16.2114 · Cited by 1,917 · cited 4×
“Correct insertion of the tubing in the new pump required three separate sequential actions: (1) placement of the tubing top fitment into the pump, ( 2 ) insertion of a plastic side clamp into the pump to disengage the anti-free-flow mechanism, and (3) flossing of the tubing through an air-in-line sensor at the bottom…”
BackgroundMethodInfluentialMaking health care safer: a critical analysis of patient safety practices.
Shojania, K. G., Duncan, B. W., McDonald, K. M., Wachter, R. M., & Markowitz, A. J. (2001) · PubMed Central · Cited by 1,612
Systems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404
DeRosier, J., Stalhandske, E., Bagian, J. P., & Nudell, T. (2002) · The Joint Commission Journal on Quality Improvement · doi:10.1016/s1070-3241(02)28025-6 · Cited by 611 · cited 4×
“This form of FMEA was thought to be easier to apply to health care situations due to a modified hazard matrix scoring system for failure modes based on health care outcomes.(29) HFMEA uses a 4-point scale to rate severity (minor, moderate, major, catastrophic) anchored to patient outcomes and a 4-point scale for proba…”
MethodInfluentialIncidence of adverse drug events and potential adverse drug events
Bates, D. W., Cullen, D. J., & Laird, N. (1995) · International Journal of Trauma Nursing · doi:10.1016/s1075-4210(05)80011-2 · Cited by 534 · cited 4×
“The team underwent training in the use of Healthcare FMEA (HFMEA), developed by the Veterans Administration National Center for Patient Safety.29 The steps in the HFMEA process include ( 1 ) team selection, (2) process identification, (3) process mapping, (4) failure-mode identification and scoring, and (5) determinat…”
BackgroundMethodInfluentialA balance theory of job design for stress reduction
Smith, M. J., & Sainfort, P. C. (1989) · International Journal of Industrial Ergonomics · doi:10.1016/0169-8141(89)90051-6 · Cited by 488 · cited 2×
“The work system is made up of five elements: people, tasks performed, environment, organization, and tools and technologies used to complete tasks.(16) With the addition of a new technology, the effects of the work system on all elements should be considered.”
BackgroundMethodA controlled trial of smart infusion pumps to improve medication safety in critically ill patients*
Rothschild, J. M., Keohane, C. A., Cook, E. F., Orav, E. J., Burdick, E., Thompson, S., Hayes, J., & Bates, D. W. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155912.73313.cd · Cited by 301
Research works printed but not linked: 13
- 2002, Health Devices, 31, 353
- 2002, Biomed Instrum Technol, 36, 84
- 2002, Nurs Econ, 20, 80
- 2001, Jt Comm J Qual Improv, 27, 430
- 1994, Hosp Pharm, 29, 319
- 2004, Hosp Peer Rev, 29, 13
- 2002, J Am Pharm Assoc, 42, S54
- 2002, Jt Comm J Qual Improv, 28, 331
- 2004, Qual Saf Health Care, 13, 265, 10.1136/qshc.2003.007443 · doi:10.1136/qshc.2003.007443 · Paper page
- 2004, Clin Leadersh Manag Rev, 18, 37
- 2002, Jt Comm J Qual Improv, 28, 248
- 2004, Clin Leadersh Manag Rev, 18, 32
- 1998, PDA J Pharm Sci Technol, 52, 52
Cited by
Human factors systems approach to healthcare quality and patient safety
Carayon, P., Wetterneck, T. B., Rivera-Rodriguez, A. J., Hundt, A. S., Hoonakker, P., Holden, R., & Gurses, A. P. (2014) · Applied Ergonomics · doi:10.1016/j.apergo.2013.04.023 · Cited by 717
“We have conducted proactive risk assessments of intravenous (IV) medication administration (Wetterneck et al., 2006), ICU nursing medication management (Faye et al., 2010), and patient transfer from surgery to the ICU (Hundt et al., 2013).”
BackgroundMethodSelf-citationKoppel, R., Wetterneck, T., Telles, J. L., & Karsh, B.-T. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2616 · Cited by 685
“Each organization must evaluate its social, technological, and physical contexts when selecting and implementing IT,”
BackgroundSelf-citationHuq, M. S., Fraass, B. A., Dunscombe, P., Gibbons, J. P., Ibbott, G. S., Mundt, A. J., Mutic, S., Palta, J. R., Rath, F., Thomadsen, B., et al. (2016) · Medical Physics · doi:10.1118/1.4947547 · Cited by 607
Human factors and ergonomics as a patient safety practice
Carayon, P., Xie, A., & Kianfar, S. (2014) · BMJ Quality & Safety · doi:10.1136/bmjqs-2013-001812 · Cited by 249
Self-citationEvaluation of Safety in a Radiation Oncology Setting Using Failure Mode and Effects Analysis
Ford, E. C., Gaudette, R., Myers, L., Vanderver, B., Engineer, L., Zellars, R., Song, D. Y., Wong, J., & DeWeese, T. L. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.10.038 · Cited by 208
“Such methodologies are now in regular use in other healthcare disciplines: for example, to prevent chemotherapy errors (8), to improve performance in trauma (9), or to improve the design and use of equipment (10).”
BackgroundThe Balance Theory and the Work System Model … Twenty Years Later
Carayon, P. (2009) · International Journal of Human–Computer Interaction · doi:10.1080/10447310902864928 · Cited by 188
“The work system model has been used to identify factors that impact the IV medication administration process ( Wetterneck et al, 2006 ) and the outpatient surgery process ( Carayon, Schultz, & Hundt, 2004 ).”
MethodSelf-citationLiu, H., Zhang, L., Ping, Y., & Wang, L. (2020) · Journal of Evaluation in Clinical Practice · doi:10.1111/jep.13317 · Cited by 180
Human factors in patient safety as an innovation
Carayon, P. (2010) · Applied Ergonomics · doi:10.1016/j.apergo.2009.12.011 · Cited by 162
“For instance, numerous healthcare organizations have begun to use HFE tools and methods, such as FMEA of high-risk processes (DeRosier et al., 2002; Wetterneck et al., 2006) and usability evaluation of medical devices (Fairbanks and Caplan, 2004; Jaspers, 2009; Zhang et al., 2003).”
MethodSelf-citationPatient safety - the role of human factors and systems engineering.
Carayon, P., & Wood, K. E. (2010) · PubMed · Cited by 207
Self-citationFailure mode and effects analysis: too little for too much?
Franklin, B. D., Shebl, N. A., & Barber, N. (2012) · BMJ Quality & Safety · doi:10.1136/bmjqs-2011-000723 · Cited by 137
ICU nurses' acceptance of electronic health records
Carayon, P., Cartmill, R., Blosky, M. A., Brown, R., Hackenberg, M., Hoonakker, P., Hundt, A. S., Norfolk, E., Wetterneck, T. B., & Walker, J. M. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2010-000018 · Cited by 119
Self-citationFailure mode and effects analysis outputs: are they valid?
Shebl, N. A., Franklin, B. D., & Barber, N. (2012) · BMC Health Services Research · doi:10.1186/1472-6963-12-150 · Cited by 122
“Table 1 FMEA steps [2-4]”
Carayon, P., Wooldridge, A. R., Hose, B., Salwei, M. E., & Benneyan, J. C. (2018) · Health Affairs · doi:10.1377/hlthaff.2018.0723 · Cited by 136
Self-citationFactors contributing to an increase in duplicate medication order errors after CPOE implementation
Wetterneck, T. B., Walker, J. M., Blosky, M. A., Cartmill, R. S., Hoonakker, P., Johnson, M. A., Norfolk, E., & Carayon, P. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000255 · Cited by 108
Self-citationApplication of Failure Mode and Effect Analysis in a Radiology Department
Thornton, E., Brook, O. R., Mendiratta‐Lala, M., Hallett, D. T., & Kruskal, J. B. (2010) · Radiographics · doi:10.1148/rg.311105018 · Cited by 110
Is Failure Mode and Effect Analysis Reliable?
Shebl, N. A., Franklin, B. D., & Barber, N. (2009) · Journal of Patient Safety · doi:10.1097/pts.0b013e3181a6f040 · Cited by 109
Ashley, L., Armitage, G., Neary, M., & Hollingsworth, G. (2010) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(10)36053-3 · Cited by 105
A Systematic Quantitative Assessment of Risks Associated With Poor Communication in Surgical Care
Nagpal, K. (2010) · Archives of Surgery · doi:10.1001/archsurg.2010.105 · Cited by 101
Challenges to nurses' efforts of retrieving, documenting, and communicating patient care information
Keenan, G., Yakel, E., Dunn Lopez, K., Tschannen, D., & Ford, Y. B. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-000894 · Cited by 91
“Selected units were required to meet the following nurse administrator-perceived criteria at baseline: (1) adequate staffing; (2) low turnover; (3) willingness to participate in the study; and (4) nurse manager commitment to support the future study intervention.”
Macroergonomics in Health Care Quality and Patient Safety
Carayon, P., Karsh, B., Gürses, A. P., Holden, R. J., Hoonakker, P., Hundt, A. S., Montague, E. N. H., Rodriguez, A. J., & Wetterneck, T. B. (2013) · Reviews of Human Factors and Ergonomics · doi:10.1177/1557234x13492976 · Cited by 105
“N IH -PA Author M anuscript N IH -PA Author M anuscript N IH -PA Author M anuscript evaluation of its usability – in the risk assessment (Wetterneck et al., 2006).”
InfluentialSelf-citationHabraken, M., van der Schaaf, T. W., Leistikow, I. P., & Reijnders-Thijssen, P. M. J. (2009) · Ergonomics · doi:10.1080/00140130802578563 · Cited by 107
Nurses’ acceptance of Smart IV pump technology
Carayon, P., Hundt, A. S., & Wetterneck, T. B. (2010) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2010.02.001 · Cited by 100
Self-citationFailure Mode and Effects Analysis: An Empirical Comparison of Failure Mode Scoring Procedures
Ashley, L., & Armitage, G. (2010) · Journal of Patient Safety · doi:10.1097/pts.0b013e3181fc98d7 · Cited by 82
“We opted to use HFMEA, as it has been adapted specifically for health care settings, its method and materials are freely and publicly available,7 and it has been successfully used in several previous studies.(11,13,16,17,25,28,29)”
MethodElkin, P., Pelayo, S., Beuscart, R., & Beuscart-Zéphir, M.-C. (2007) · Yearbook of Medical Informatics · doi:10.1055/s-0038-1638535 · Cited by 74
“Infusion pumps [77;78] H F driven implementation process Prevention of errors Failure Mode and Effects Analysis (FMEA) = systematic review of potential errors involving the infusion pump - Multidisciplinary team - Identification and categorization of potential errors - Decision / barriers to errors recommended actions…”
BackgroundMethodSociotechnical systems approach to healthcare quality and patient safety
Carayon, P. (2012) · Work · doi:10.3233/wor-2012-0091-3850 · Cited by 74
“…and methods used to evaluate healthcare work systems and processes and their impact on healthcare quality and patient safety, such as questionnaire survey [4] [23] [24], observation methodology [13] [14], interviews [3] [20], and proactive risk assessment of healthcare processes [8] [38] [40] .”
MethodSelf-citationAn Innovative Risk Assessment Methodology for Medical Information Systems
Coronato, A., & Cuzzocrea, A. (2020) · IEEE Transactions on Knowledge and Data Engineering · doi:10.1109/tkde.2020.3023553 · Cited by 62
Schein, J. R., Hicks, R. W., Nelson, W. W., Sikirica, V., & Doyle, D. J. (2009) · Drug Safety · doi:10.2165/00002018-200932070-00002 · Cited by 64
Waite, S., Scott, J. A., Legasto, A. C., Kolla, S. S., Gale, B. D., & Krupinski, E. A. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.17719 · Cited by 58
Work design and patient safety§
Carayon, P., Alvarado, C. J., & Hundt, A. S. (2007) · Theoretical Issues in Ergonomics Science · doi:10.1080/14639220701193157 · Cited by 60
“FMEAs are typically conducted by multidisciplinary teams within the organization on everything from patient care processes, such as medication administration to device design (see, for example, the FMEA of an infusion pump by Wetterneck et al. (2006)).”
BackgroundSelf-citationWork system barriers and facilitators in inpatient care transitions of pediatric trauma patients
Wooldridge, A. R., Carayon, P., Hoonakker, P., Hose, B., Eithun, B. L., Brazelton, T., Ross, J., Kohler, J. E., Kelly, M. M., Dean, S. M., et al. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103059 · Cited by 52
“1 Work System Barriers and Facilitators Process analysis can be used to identify opportunities for improvement (Jun et al., 2011; Jun et al., 2010; Jun et al., 2009; Simsekler et al., 2018a, 2018b; Wetterneck et al., 2006; Wooldridge et al., 2017).”
BackgroundSelf-citationWierenga, P. C., Lie‐A‐Huen, L., de Rooij, S. E., Klazinga, N., Guchelaar, H., & Smorenburg, S. M. (2009) · Drug Safety · doi:10.2165/00002018-200932080-00005 · Cited by 59
Using failure mode and effects analysis to improve the safety of neonatal parenteral nutrition
Villafranca, J. A., Sánchez, A. G., GUINDO, M. N., & Felipe, V. F. (2014) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp130640 · Cited by 53
Human Factors and Ergonomics in Health Care
Carayon, P., Alyousef, B., & Xie, A. (2012) · Wiley eBooks · doi:10.1002/9781118131350.ch57 · Cited by 52
Self-citationIntegration of prospective and retrospective methods for risk analysis in hospitals
Kessels-Habraken, M. M., van der Schaaf, T., JONGE, J. D., Rutte, C. G., & Kerkvliet, K. (2009) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzp043 · Cited by 50
“In only a few prior studies have researchers concentrated on integration of methods, for instance by using retrospective error rates for prospective analyses [9, 25], or by comparing prospectively and retrospectively identified causes of risks [26].”
BackgroundGürses, A. P., Dietz, A. S., Nowakowski, E., Andonian, J. S., Schiffhauer, M., Billman, C., Abashian, A. M., Trexler, P. A., Osei, P., Benishek, L. E., et al. (2018) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2018.292 · Cited by 44
“HCW should be turning around to help TO/DA with assessment (15, 16) 10.”
BackgroundFaye, H., Rivera-Rodriguez, A. J., Karsh, B., Hundt, A. S., Baker, C., & Carayon, P. (2010) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(10)36056-9 · Cited by 47
Self-citationIntroducing a change in hospital policy using FMEA methodology as a tool to reduce patient hazards
Ofek, F., Magnezi, R., Kurzweil, Y., Gazit, I., Berkovitch, S., & Tal, O. (2016) · Israel Journal of Health Policy Research · doi:10.1186/s13584-016-0090-7 · Cited by 44
“Our work, similarly to other studies using FMEA methodology [15, 16], showed that FMEA prioritizes the potential harms and minimizes riskiness of complex processes.”
ResultHundt, A. S., Adams, J. A., Schmid, J. A., Musser, L. M., Walker, J. M., Wetterneck, T. B., Douglas, S. V., Paris, B. L., & Carayon, P. (2013) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2012.04.005 · Cited by 40
“PRA methods have been used to identify potential vulnerabilities associated with changes in processes [9] and technology implementation, including those related to the implementation of Smart infusion pump technology [14] and to identify strategies for dealing with vulnerabilities associated with IT-mediated medicatio…”
MethodSelf-citationThe Use of Smart Pumps for Preventing Medication Errors
Hertzel, C., & Sousa, V. D. (2009) · Journal of Infusion Nursing · doi:10.1097/nan.0b013e3181b40e2e · Cited by 45
Kok, C. L., Ho, C. K., Lee, T. K., Loo, Z. Y., Koh, Y. Y., & Chai, J. P. (2024) · Electronics · doi:10.3390/electronics13101801 · Cited by 35
Steinberger, D., Douglas, S. V., & Kirschbaum, M. (2009) · Progress in Transplantation · doi:10.1177/152692480901900303 · Cited by 35
“Although it is true that the complexity of health care is unlike that of any other industry, FMEA has been successfully applied to clinical situations before the introduction of new clinical devices.(8) FMEA methods were imported to health care from other industries by leaders in patient safety, including the National…”
MethodSchraagen, J. M., & Verhoeven, F. (2012) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.10.005 · Cited by 37
“[60] Pre–post intervention Evaluation of smart iv pump by FMEA Failure modes No specific before–after data were reported in this study Impossible to evaluate effectiveness of design changes Hicks et al.”
Ashley, L., Dexter, R., Marshall, F., McKenzie, B., Ryan, M., & Armitage, G. (2011) · Oncology nursing forum · doi:10.1188/11.onf.e436-e444 · Cited by 32
“, scale descriptors for failure mode scoring are specific to a healthcare setting rather than a general, industrial context) and has been successfully used in several previous healthcare FMEA programs (Esmail et al., 2005; Habraken, Van der Schaaf, Leistikow, & ReijndersThijssen, 2009; Kimchi-Woods & Shultz, 2006; Lin…”
InfluentialVecchia, M., Sacchi, P., Marvulli, L. N., Ragazzoni, L., Muzzi, A., Polo, L., Bruno, R., & Salio, F. (2025) · Healthcare · doi:10.3390/healthcare13010082 · Cited by 37
Manrique‐Rodríguez, S., Sánchez-Galindo, A., López‐Herce, J., Calleja‐Hernández, M. Á., Peinado, I. I., Carrillo-Álvarez, Á., Sáez, M. S., & Fernandez-Llamazares, C. M. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462314000051 · Cited by 29
“(21) identified other aspects of the hardware that could be improved.”
BackgroundResultInfluentialFMEA Team Performance in Health Care: A Qualitative Analysis of Team Member Perceptions
Wetterneck, T. B., Hundt, A. S., & Carayon, P. (2009) · Journal of Patient Safety · doi:10.1097/pts.0b013e3181a852be · Cited by 27
“The FMEA process itself can be time consuming and resource intensive for health care organizations.(1,3,6,11,12) To efficiently and effectively plan for and perform an FMEA, the health care organization chooses a process or technology and assembles a team to evaluate it.”
BackgroundSelf-citationSiv-Lee, L., & Morgan, L. (2007) · Hospital Pharmacy · doi:10.1310/hpj4209-832 · Cited by 25
“tion and/or infusion rate into the pump.(5,6) Errors relating to programming of the infusion pump have the greatest likelihood of causing patient harm.”
BackgroundHUMAN FACTORS AND ERGONOMICS IN HEALTH CARE
Carayon, P., Wust, K. L., Hose, B., & Salwei, M. E. (2021) · Wiley eBooks · doi:10.1002/9781119636113.ch53 · Cited by 32
Self-citationFMEA for Proactive Healthcare Risk Analysis: A Systematic Literature Review
Liu, H. (2019) · Springer eBooks · doi:10.1007/978-981-13-6366-5_2 · Cited by 24
Ashour, A., Phipps, D. L., & Ashcroft, D. M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0261672 · Cited by 25
“crane operations) [11], as well as identify key insights within healthcare processes [12, 13].”
BackgroundImproving Patient Safety in the Patient Journey: Contributions from Human Factors Engineering
Carayon, P., & Wooldridge, A. R. (2019) · Women in engineering and science · doi:10.1007/978-3-030-11866-2_12 · Cited by 35
Self-citationSmart Pump Technology: What We Have Learned
Elias, B. L., & Moss, J. A. (2010) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e3181fcbe6d · Cited by 23
Poder, T. G. (2017) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462317000125 · Cited by 22
Moss, J. (2010) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(10)36054-5 · Cited by 22
Silveira, E. D., Álvarez‐Díaz, A. M., Menéndez-Conde, C. P., Pérez, J. S., Sagrado, M. Á. R., & Vicedo, T. B. (2011) · Farmacia Hospitalaria · doi:10.1016/j.farma.2010.12.002 · Cited by 33
Clinical risk assessment in intensive care unit.
Asefzadeh, S., Yarmohammadian, M. H., Nikpey, A., & Atighechian, G. (2013) · PubMed Central · Cited by 21
Chadwick, L. M., & Fallon, E. F. (2012) · Human Factors and Ergonomics in Manufacturing & Service Industries · doi:10.1002/hfm.20302 · Cited by 23
“This issue regarding the HFMEA® technique has been reported in other studies (KesselsHabraken, Van der Schaaf, Leistikow, & ReijndersThijssen, 2009; Wetterneck et al., 2006).”
MethodKhare, R. K., Nannicelli, A. P., Powell, E. S., Seivert, N. P., Adams, J. G., & Holl, J. L. (2013) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2013.01.023 · Cited by 20
Gershengorn, H. B., Kocher, R. P., & Factor, P. H. (2014) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201306-177as · Cited by 23
Care transition of trauma patients: Processes with articulation work before and after handoff
Wooldridge, A. R., Carayon, P., Hoonakker, P., Hose, B., Schroeer, K., Brazelton, T., Eithun, B. L., Rusy, D. A., Ross, J., Kohler, J. E., et al. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103606 · Cited by 21
Self-citationde Vries, M., Fan, M., Tscheng, D., Hamilton, M., & Trbovich, P. (2019) · BMJ Open · doi:10.1136/bmjopen-2018-027629 · Cited by 18
Alamry, A., Owais, S. M. A., Marini, A. M., Al‐Dorzi, H. M., Alsolamy, S. J., & Arabi, Y. M. (2014) · Journal of Patient Safety · doi:10.1097/pts.0000000000000118 · Cited by 24
Evaluation of Time- and Cost-Saving Modifications of HFMEA: An Experimental Approach in Radiotherapy
Vlayen, A. (2011) · Journal of Patient Safety · doi:10.1097/pts.0b013e31822b07ee · Cited by 16
Park, J., You, S. B., Ryu, G. W., & Kim, Y. (2023) · Systematic Reviews · doi:10.1186/s13643-023-02386-z · Cited by 15
“…vascular access related to patient posture [20] - Lack of knowledge about medication equipment [23] - Lack of drug knowledge about medications [24] Performance deficit - Failure to check equipment properly [21] - Tubing misplacement [24, 35] - Monitoring inadequate [25] - Non-compliance with…”
BackgroundInfluentialMultiple Intravenous Infusions Phase 2b: Laboratory Study.
Pinkney, S. J., Fan, M., Chan, K., Koczmara, C., Colvin, C., Sasangohar, F., Masino, C., Easty, A., & Trbovich, P. (2014) · PubMed · Cited by 15
Ending Infusion Confusion: Evaluating a Virtual Intravenous Pump Educational Module
Luctkar‐Flude, M., Pulling, C., & Larocque, M. (2010) · Clinical Simulation in Nursing · doi:10.1016/j.ecns.2010.06.001 · Cited by 15
“Nurses in clinical practice do not always use added safety measures incorporated into smart IV pumps, such as channel labeling and drug libraries, and often override the programmed alerts (Wetterneck et al., 2006).”
BackgroundMohanty, M., Lawal, O. D., Skeer, M. R., Lanier, R. K., Erpelding, N., & Katz, N. P. (2018) · Therapeutic Advances in Drug Safety · doi:10.1177/2042098618773013 · Cited by 15
Waterson, J., Al-Jaber, R., Kassab, T., & Al‐Jazairi, A. S. (2020) · JMIR Human Factors · doi:10.2196/20364 · Cited by 14
“We also recognize that among all of the parts of the medication chain (from prescription to administration), intravenous medication errors, which occur at the point of administration, are the hardest to detect and that in terms of failure mode effect analysis (FMEA), the process consistently scores as a high-risk acti…”
MethodSaulino, M. F., Patel, T., & Fisher, S. P. (2016) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12475 · Cited by 14
Perceptions of the Impact of “Smart Pumps” on Nurses and Nursing Care Provided
Rosenkoetter, M. M., Bowcutt, M., Khasanshina, E. V., Chernecky, C. C., & Wall, J. (2008) · Journal of the Association for Vascular Access · doi:10.2309/java.13-2-3 · Cited by 18
Shah, N., & Jani, Y. H. (2020) · Pharmacy · doi:10.3390/pharmacy8040239 · Cited by 13
“, 2006 [18] Identify risks of implementation of smart pumps and evaluate IV pump technologies that could improve pump programming accuracy and decrease errors with IV medication Failure mode and effects analysis (FMEA) was used to guide successful implementation FMEA is a useful tool for implementation of smart pumps…”
MethodRashed, A. N., Whittlesea, C., Davies, C., Forbes, B., & Tomlin, S. (2019) · BMC Anesthesiology · doi:10.1186/s12871-019-0697-7 · Cited by 12
Pinkney, S. J., Fan, M., Koczmara, C., & Trbovich, P. (2019) · Critical Care Medicine · doi:10.1097/ccm.0000000000003790 · Cited by 12
Shahrami, A., Rahmati, F., Kariman, H., Hashemi, B., Rahmati, M., Baratloo, A., Forouzanfar, M. M., & Safari, S. (2013) · Archives of Academic Emergency Medicine · doi:10.22037/aaem.v1i1.6 · Cited by 11
Strielkina, A., Kharchenko, V. S., & Узун, Д. Д. (2019) · Communications in computer and information science · doi:10.1007/978-3-030-13929-2_11 · Cited by 11
Carayon, P., Wetterneck, T. B., Hundt, A. S., Rough, S. S., & Schroeder, M. E. (2008) · Contributions to management science · doi:10.1007/978-3-7908-2046-1_9 · Cited by 13
Self-citationUsing Human-Centered Systems Engineering to Reduce Nurse Stakeholder Dissonance
Samaras, E. A., & Samaras, G. M. (2010) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-44.s1.25 · Cited by 11
Human Factors in Health(care) Informatics: Toward Continuous Sociotechnical System Design
Carayon, P. (2019) · Studies in health technology and informatics · doi:10.3233/shti190131 · Cited by 11
Self-citationMancosu, P., Signori, C., Clerici, E., Comito, T., D’Agostino, G. R., Franceschini, D., Franzese, C., Lobefalo, F., Navarria, P., Paganini, L., et al. (2020) · Practical Radiation Oncology · doi:10.1016/j.prro.2020.11.002 · Cited by 10
Research: Comparison of Automated versus Manual Programming of Infusion Pumps
Pham, J. C., Carson, K. A., Benson, J., Doyle, P. A., Ijagbemi, M., Ravitz, A., Wyskiel, R. M., & Tran, G. M. (2016) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-50.4.242 · Cited by 9
Critical failures in the use of home ventilation medical equipment
Clemente, F., Faiella, G., Rutoli, G., Bifulco, P., Romano, M., & Cesarelli, M. (2019) · Heliyon · doi:10.1016/j.heliyon.2019.e03034 · Cited by 9
Methodology to assess medical processes based on a Failure Mode and Effects Analysis (FMEA)
Sobral, J., Teixeira, D., Morais, H., & Neves, M. (2017) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2017.7889469 · Cited by 9
Smart Pump Technology: What We Have Learned
Elias, B. L., & Moss, J. A. (2011) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e31821ef813 · Cited by 10
“In one preimplementation evaluation of smart pumps using FMEA, the evaluation team identified the majority of points of failure for smart pump processes (13 of 18 failure modes reported after implementation).(17) Several of the points of failure that were not anticipated related to tubing connections and misplacement.”
BackgroundMethodNiv, Y., Itskoviz, D., Cohen, M., Hendel, H., Bar-Giora, Y., Berkov, E., Weisbord, I., Leviron, Y., Isasschar, A., & Ganor, A. (2018) · Quality Management in Health Care · doi:10.1097/qmh.0000000000000166 · Cited by 10
Royer, M., Libessart, M., Dubaele, J.-M., Tourneux, P., & Marçon, F. (2020) · Pharmaceutical Technology in Hospital Pharmacy · doi:10.1515/pthp-2019-0020 · Cited by 8
Feemster, A. A., Augustino, M., Duncan, R., Khandoobhai, A., & Rowcliffe, M. (2021) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/zxab179 · Cited by 7
“members of this project are unaware of a healthcare FMEA team that has included vendor representatives as part of the multidisciplinary group.(9) The addition of vendor contacts proved to be beneficial for 2 primary reasons.”
BackgroundUsing Failure Mode and Effects Analysis to Design a Mobile Extracorporeal Membrane Oxygenation Team
Meyer, M. T., Braby, J., & Scanlon, M. C. (2011) · Air Medical Journal · doi:10.1016/j.amj.2010.12.002 · Cited by 7
Ergonomics in Healthcare and Patient Safety
(2014) · Journal of Ergonomics · doi:10.4172/2165-7556.1000e126 · Cited by 6
“Various ergonomics and human factors methods can be used to anticipate some of the potential failures and problems related to the implementation and use of a medical device or HIT [17].”
InfluentialDevelopment of a Simulated Smart Pump Interface
Elias, B. L., Moss, J. A., Shih, A. M., & Dillavou, M. (2013) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000016 · Cited by 6
“For example, one area of concern is the order and size of the on-board drug libraries, primarily due to differences in drugs and dosing among hospital units.(12) Also of concern is the design of the pump’s keypad and display.”
BackgroundUsing Failure Mode and Effects Analysis to identify hazards within resuscitation
Brodie, A., Kinross, J. K., Bailey, M., Aggarwal, R. K., & Vincent, C. A. (2009) · International Journal of Risk & Safety in Medicine · doi:10.3233/jrs-2009-0483 · Cited by 6
“FMEA has been applied to evaluate and prevent medication errors [12,21,26,27,37], improve IV drug administration [3,4,38], reduce risks in blood transfusions [5], plain-radiographic labelling errors [1], prevention of inpatient falls [15], equipment problems [13,22,23,35,36] and as a performance…”
Learning from Risk Assessment in Radiotherapy
Fallon, E. F., Chadwick, L. M., & van der Putten, W. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02809-0_53 · Cited by 6
“They have successfully applied a number of HF engineering techniques to the examination of issues relating to surgical techniques, medication administration, dental procedures and intravenous drug infusion equipment [17-20].”
BackgroundA Markov Model of Healthcare Internet of Things System Considering Failures of Components
Strielkina, A., Kharchenko, V. S., & Узун, Д. Д. (2017) · International Conference on ICT in Education, Research and Industrial Applications: Integration, Harmonization and Knowledge Transfer (ICTERI) · doi:10.55056/ceur-ws.org/vol-2104/paper_232.pdf · Cited by 6
Analyse des risques en radiothérapie: Partie 1 : Forces et faiblesses de la méthode AMDEC
Thellier, S. (2019) · Radioprotection · doi:10.1051/radiopro/2019004 · Cited by 6
Audit of the Use of a Smart Infusion Pump's Drug Libraries
Tan, I. S., Dinh, N. T., Kong, R. E., MacMillan, K., McGain, F., Kong, R. E., & McGain, F. (2013) · Journal of Pharmacy Practice and Research · doi:10.1002/j.2055-2335.2013.tb00275.x · Cited by 6
Embedded Solutions for IoT Based Automated Drug Infusion Device
Kok, C. L., Loo, Z. Y., & Chai, J. P. (2023) · International SoC Design Conference · doi:10.1109/isocc59558.2023.10396203 · Cited by 5
Morgan, L., & Siv-Lee, L. (2009) · Nursing Management · doi:10.1097/01.numa.0000345869.68824.6b · Cited by 5
Baker, D. K., Hoffman, J. M., Hale, G. A., Spunt, S. L., Sanderlin, D., Rodman, J. H., & Shenep, J. L. (2008) · Cited by 6
Tamene, M., Morris, A., Feinberg, E., & Bair‐Merritt, M. H. (2020) · Clinical Practice in Pediatric Psychology · doi:10.1037/cpp0000365 · Cited by 4
“…processes, including addressing safety in blood transfusions (Mora, Ayala, Bielza, Ataúlfo González, & Villegas, 2019), communication between hospital staff (Bag-nasco et al., 2013), administering intravenous drugs (Wetterneck et al., 2006), and reducing errors in chemotherapy (Kim et al., 2006).”
Yazdanıan, M., Alam, M. M. R., Rafiee, E., Tahmasebi, E., Ghaffarpasand, A., Abbasi, K., & Bahadori, M. (2022) · Dentistry 3000 · doi:10.5195/d3000.2022.238 · Cited by 4
Gates, E. D. H., Wallner, K. E., Tiwana, J. K., Ford, E., Phillips, M., Lu, L., Dumane, V. A., Sheu, R., & Kim, M. (2023) · Brachytherapy · doi:10.1016/j.brachy.2023.07.009 · Cited by 4
Metadata
- Authors
- Wetterneck, T. B., Skibinski, K. A., Roberts, T. L., Kleppin, S. M., Schroeder, M. E., Enloe, M., Rough, S. S., Hundt, A. S., & Carayon, P.
- Affiliations
- University of Wisconsin–Madison (US)
- University of Wisconsin Health (US)
- Department of Anesthesiology, UWSMPH
- UW Health University Hospital (US)
- Corresponding author
- Wetterneck, Tosha B.
- ORCID
- Carayon, Pascale
- Venue
- American Journal of Health-System Pharmacy
- Publisher
- Oxford University Press (OUP)
- Published
- 2006-08-15
- Volume
- 63
- Issue
- 16
- Pages
- 1528-1538
- ISSN
- 1079-2082 (ISSN-L)
- 1535-2900
- OpenAlex
- W1983207700
- Cited by
- 134
- References
- 35
- Citations by year
- 2025: 1 · 2024: 3 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 8 · 2019: 12 · 2018: 6 · 2017: 5 · 2016: 8 · 2015: 2 · 2014: 8 · 2013: 11 · 2012: 10
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Health-System Pharmacy (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Agency for Healthcare Research and Quality (1uc1hs014253-01)
- National Center for Research Resources (1 K12-RR01764-01)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- failure mode and effects analysis, smart infusion pumps, medication errors, drug library, patient safety, adverse event investigation, multidisciplinary team, technology implementation
- MeSH terms
- Equipment Safety, Humans, Infusion Pumps, Infusions, Intravenous, Reproducibility of Results, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.