The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Electrospun gelatin/PCL and collagen/PLCL scaffolds for vascular tissue engineering
Open accessAbstract
Electrospun hybrid nanofibers prepared using combinations of natural and synthetic polymers have been widely investigated in cardiovascular tissue engineering. In this study, electrospun gelatin/polycaprolactone (PCL) and collagen/poly(l-lactic acid-co-ε-caprolactone) (PLCL) scaffolds were successfully produced. Scanning electron micrographs showed that fibers of both membranes were smooth and homogeneous. Water contact angle measurements further demonstrated that both scaffolds were hydrophilic. To determine cell attachment and migration on the scaffolds, both hybrid scaffolds were seeded with human umbilical arterial smooth muscle cells. Scanning electron micrographs and MTT assays showed that the cells grew and proliferated well on both hybrid scaffolds. Gross observation of the transplanted scaffolds revealed that the engineered collagen/PLCL scaffolds were smoother and brighter than the gelatin/PCL scaffolds. Hematoxylin and eosin staining showed that the engineered blood vessels constructed by collagen/PLCL electrospun membranes formed relatively homogenous vessel-like tissues. Interestingly, Young's modulus for the engineered collagen/PLCL scaffolds was greater than for the gelatin/PCL scaffolds. Together, these results indicate that nanofibrous collagen/PLCL membranes with favorable mechanical and biological properties may be a desirable scaffold for vascular tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospun nanofibrous structure: A novel scaffold for tissue engineering
Li, W., Laurencin, C. T., Caterson, E. J., Tuan, R. S., & Ko, F. K. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10167 · Cited by 2,427
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Sustained Release of Proteins from Electrospun Biodegradable Fibers
Chew, S. Y., Wen, J., Yim, E. K. F., & Leong, K. W. (2005) · Biomacromolecules · doi:10.1021/bm0501149 · Cited by 584
Electrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Novel biodegradable electrospun membrane: scaffold for tissue engineering
Bhattarai, S. R., Bhattarai, N., Yi, H. K., Hwang, P. H., Cha, D. I., & Kim, H. Y. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.09.043 · Cited by 480
Three-dimensional electrospun ECM-based hybrid scaffolds for cardiovascular tissue engineering
Heydarkhan-Hagvall, S., Schenke-Layland, K., Dhanasopon, A. P., Rofail, F., Smith, H., Wu, B. M., Shemin, R., Beygui, R. E., & MacLellan, W. R. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.034 · Cited by 445
The in vivo stability of electrospun polycaprolactone-collagen scaffolds in vascular reconstruction
Tillman, B. W., Yazdani, S. K., Lee, S. J., Geary, R. L., Atala, A., & Yoo, J. J. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.006 · Cited by 383
Lee, S. J., Liu, J., Oh, S. H., Soker, S., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.032 · Cited by 353
Regulating Bone Formation via Controlled Scaffold Degradation
Alsberg, E., Kong, H. J., Hirano, Y., Smith, M. K., Albeiruti, A., & Mooney, D. J. (2003) · Journal of Dental Research · doi:10.1177/154405910308201111 · Cited by 327
The Mechanical Properties of Infrainguinal Vascular Bypass Grafts: Their Role in Influencing Patency
Sarkar, S., Salacinski, H. J., Hamilton, G., & Seifalian, A. M. (2006) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2006.01.006 · Cited by 301
Biomaterials and scaffold design: key to tissue‐engineering cartilage
Raghunath, J., Rollo, J., Sales, K. M., Butler, P. E., & Seifalian, A. M. (2007) · Biotechnology and Applied Biochemistry · doi:10.1042/ba20060134 · Cited by 222
Tissue engineering of blood vessel
Zhang, W. J., Liu, W., Cui, L., & Cao, Y. (2007) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2007.00099.x · Cited by 217
Performance of a multilayered small-diameter vascular scaffold dual-loaded with VEGF and PDGF
Han, F., Jia, X., Dai, D., Yang, X., Zhao, J., Zhao, Y., Fan, Y., & Yuan, X. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.06.006 · Cited by 174
A sandwich model for engineering cartilage with acellular cartilage sheets and chondrocytes
Gong, Y. Y., Xue, J. X., Zhang, W. J., Zhou, G. D., Liu, W., & Cao, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.078 · Cited by 170
Zheng, R., Duan, H., Xue, J., Liu, Y., Feng, B., Zhao, S., Zhu, Y., Liu, Y., He, A., Zhang, W., et al. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.09.082 · Cited by 167
Self-citationEngineering ear-shaped cartilage using electrospun fibrous membranes of gelatin/polycaprolactone
Xue, J., Feng, B., Zheng, R., Lu, Y., Zhou, G., Liu, W., Cao, Y., Zhang, Y., & Zhang, W. J. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.12.011 · Cited by 162
Self-citationTissue-Engineered Blood Vessels: Alternative to Autologous Grafts?
Hoenig, M. R., Campbell, G. R., Rolfe, B. E., & Campbell, J. H. (2005) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000158996.03867.72 · Cited by 161
McKenna, K. A., Hinds, M. T., Sarao, R. C., Wu, P.-C., Maslen, C. L., Glanville, R. W., Babcock, D., & Gregory, K. W. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.08.001 · Cited by 158
Fabrication of silk fibroin blended P(LLA‐CL) nanofibrous scaffolds for tissue engineering
Zhang, K., Wang, H., Huang, C., Su, Y., Mo, X., & Ikada, Y. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32504 · Cited by 153
Self-citationTubular nanofiber scaffolds for tissue engineered small‐diameter vascular grafts
He, W., Ma, Z., Teo, W. E., Dong, Y. X., Robless, P. A., Lim, T. C., & Ramakrishna, S. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32081 · Cited by 152
Xu, Y., Wu, J., Wang, H., Li, H., Di, N., Song, L., Li, S., Li, D., Xiang, Y., Liu, W., et al. (2013) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2012.0328 · Cited by 129
Self-citationYin, A., Zhang, K., McClure, M. J., Huang, C., Wu, J., Fang, J., Mo, X., Bowlin, G. L., Al‐Deyab, S. S., & El-Newehy, M. H. (2012) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34434 · Cited by 122
A quantitative method for evaluating the degradation of biologic scaffold materials
Gilbert, T. W., Stewart‐Akers, A. M., & Badylak, S. F. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.08.022 · Cited by 117
An in vitro regenerated functional human endothelium on a nanofibrous electrospun scaffold
Zhang, X., Thomas, V., Xu, Y., Bellis, S. L., & Vohra, Y. K. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.017 · Cited by 92
Zhang, Duan, Feng, B., Guo, Wang, Zhao, Zhou, Wei, W., & Cao (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s42384 · Cited by 87
Self-citationZhou, M., Liu, Z., Wei, Z., Liu, C., Qiao, T., Ran, F., Bai, Y., Jiang, X., & Ding, Y. (2009) · Artificial Organs · doi:10.1111/j.1525-1594.2009.00713.x · Cited by 79
Self-citationImmediate production of a tubular dense collagen construct with bioinspired mechanical properties
Ghezzi, C. E., Marelli, B., Muja, N., & Nazhat, S. N. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.01.025 · Cited by 68
Effect of bioactive glass particles on the thermal degradation behaviour of medical polyesters
Larrañaga, A., & Sarasua, J.-R. (2012) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2012.12.015 · Cited by 50
He, X., Fu, W. E., Feng, B., Wang, H., Liu, Z., Yin, M., Wang, W., & Zheng, J. (2013) · Regenerative Medicine · doi:10.2217/rme.13.29 · Cited by 43
Self-citationFernández, J., Etxeberría, A., & Sarasua, J. R. (2013) · Polymer Degradation and Stability · doi:10.1016/j.polymdegradstab.2013.04.003 · Cited by 40
Tissue-engineered graft constructed by self-derived cells and heterogeneous acellular matrix
Huang, H., Wu, S., & Ren, H. (2006) · Journal of Zhejiang University SCIENCE B · doi:10.1631/jzus.2006.b0351 · Cited by 5
Self-citation
Cited by
Electrospinning for tissue engineering applications
Rahmati, M., Mills, D. K., Urbanska, A. M., Saeb, M. R., Venugopal, J. R., Ramakrishna, S., & Mozafari, M. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100721 · Cited by 816
Design Challenges in Polymeric Scaffolds for Tissue Engineering
Echeverria Molina, M. I., Malollari, K. G., & Komvopoulos, K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.617141 · Cited by 397
Collagen based electrospun materials for skin wounds treatment
Hernández‐Rangel, A., & Martin‐Martinez, E. S. (2021) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37154 · Cited by 133
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Metadata
- Authors
- Fu, W., Liu, Z., Feng, B., Hu, R., He, X., Wang, H., Yin, M., Huang, H., Zhang, H., & Wang, W.
- Venue
- International Journal of Nanomedicine
- Publisher
- Informa UK Limited
- Published
- 2014-05
- Volume
- 9
- Pages
- 2335
- ISSN
- 1176-9114 (ISSN-L)
- 1178-2013
- OpenAlex
- W2150311904
- Cited by
- 272
- References
- 33
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.