CoChat

Smartphone viewing distance and sleep: an experimental study utilizing motion capture technology

Open access
Yoshimura, Michitaka, Kitazawa, Momoko, Maeda, Yasuhiro, Mimura, Masaru, Tsubota, Kazuo, Kishimoto, Taishiro · 2017 · Nature and Science of Sleep

The DOI matches its Crossref record; 28 of the 30 references it cites were found in a registry or an index; none of the 21 sources its claims cite is checked for support yet.

Abstract

There are studies reporting the negative impact of smartphone utilization on sleep. It is considered that reduction of melatonin secretion under the blue light exposure from smartphone displays is one of the causes. The viewing distance may cause sleep disturbance, because the viewing distance determines the screen illuminance and/or asthenopia. However, to date, there has been no study closely investigating the impact of viewing distance on sleep; therefore, we sought to determine the relationship between smartphone viewing distance and subjective sleep status. Twenty-three nursing students (mean age ± standard deviation of 19.7±3.1 years) participated in the study. Subjective sleep status was assessed using the Pittsburgh Sleep Quality Index, morningness–eveningness questionnaire, and the Epworth sleepiness scale. We used the distance between the head and the hand while holding a smartphone to measure the viewing distance while using smartphones in sitting and lying positions. The distance was calculated using the three-dimensional coordinates obtained by a noncontact motion-sensing device. The viewing distance of smartphones in the sitting position ranged from 13.3 to 32.9 cm among participants. In the lying position, it ranged from 9.9 to 21.3cm. The viewing distance was longer in the sitting position than in the lying position (mean ± standard deviation: 20.3±4.7 vs 16.4±2.7, respectively, P <0.01). We found that the short viewing distance in the lying position had a positive correlation to a poorer sleep state ( R 2 =0.27, P <0.05), lower sleep efficiency ( R 2 =0.35, P <0.05), and longer sleep latency ( R 2 =0.38, P <0.05). Moreover, smartphone viewing distances in lying position correlated negatively with subjective sleep status. Therefore, when recommending ideal smartphone use in lying position, one should take into account the viewing distances. Keywords: smartphone, sleep, blue light, distance

Overview

CoChat Summary

## TL;DR

This experimental study of 23 nursing students found that smartphone viewing distance was shorter when lying down than when sitting, and shorter lying-position distances were associated with worse subjective sleep. The authors conclude that smartphone use recommendations should consider viewing distance.

## Key findings

  • In 23 nursing students (mean age 19.7±3.1 years; 4/23 male), the mean smartphone viewing distance was 20.3±4.7 cm in sitting and 16.4±2.7 cm in lying position; the sitting distance was significantly longer (t(21)=3.604, P<0.01).
  • Viewing distance in the lying position ranged from 9.9 to 21.3 cm, and in the sitting position from 13.3 to 32.9 cm.
  • Multiple regression found that shorter viewing distance in the lying position was associated with poorer sleep state (R2=0.27, P<0.05), lower sleep efficiency (R2=0.35, P<0.05), and longer sleep latency (R2=0.38, P<0.05).
  • There were no significant associations between sitting-position viewing distance and any sleep variables.
  • The smartphone display spectrum peaked at 453 nm; estimated illuminance at the measured mean viewing distances was 25.3–42.6 lx when sitting and 50.5–80.4 lx when lying.

## Methods

  • Experimental study with 23 healthy nursing students who owned smartphones and reported using them before sleep; they were randomly assigned to start in either sitting or lying position.
  • Viewing distance was measured with Microsoft Kinect for Windows using the distance between the head and hand while holding an Apple iPhone 5; the viewing distance was recorded every 10 seconds during 14.5 minutes sitting and 22.3 minutes lying, with a 5-minute interval between conditions.
  • Subjective sleep status was assessed using the PSQI, MEQ, and ESS; analyses used paired t-tests for position differences and multiple regression for associations with sleep measures.

## Limitations

  • The paper states it did not measure duration of smartphone use, which could affect sleep quality.
  • The paper states it did not measure melatonin, EEG, or other biological indices, so it could not examine direct physiological effects.
  • The paper states the study used unfamiliar bedding, only two body positions (sitting and lying), fixed room illuminance (600 lx), did not rule out psychiatric/physical diseases, and was conducted in the daytime; these are stated limitations.
  • Evident from the text: the sample was small and specific (23 nursing students), which limits generalizability.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2147/nss.s123319

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The layout for the experimental settings. Notes: (A) layout for lying position. (B) Layout for sitting position.
Figure 1 The layout for the experimental settings. Notes: (A) layout for lying position. (B) Layout for sitting position.CC BY-NC · PubMed Central
Figure 2 Spectral radiometric profile of the smartphone (measured at 90°/10 cm from iPhone 5). Abbreviation: CCD, Charge-Coupled Device.
Figure 2 Spectral radiometric profile of the smartphone (measured at 90°/10 cm from iPhone 5). Abbreviation: CCD, Charge-Coupled Device.CC BY-NC · PubMed Central
Figure 3 Illuminance of smartphone at various distances and angles. Notes: Gray circles and diamonds show the illuminances at the mean distances measured in this experiment.
Figure 3 Illuminance of smartphone at various distances and angles. Notes: Gray circles and diamonds show the illuminances at the mean distances measured in this experiment.CC BY-NC · PubMed Central

Verification

Claims the paper makes

0 Valid · 0 Not valid · 18 Not checked · 25 Own results and interpretations

13 more claims

Create a free account to see all 43 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 19
  • It may state two separate claims as one. 12

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Statistics recomputed

Every reported test result, recomputed from its test statistic and degrees of freedom. A result shows as not adding up only once an independent check has confirmed it.

  • Consistentt(21) = 3.604reported p < .01 · recomputed p = .002

    “t(21)=3.604, p < .01”

1 of 1

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Self-check results appear here once an independent check has confirmed them.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Yoshimura, M., Kitazawa, M., Maeda, Y., Mimura, M., Tsubota, K., & Kishimoto, T.
Affiliations
  • Keio University (JP)
  • RIKEN Center for Advanced Photonics (JP)
  • Hofstra University (US)
Corresponding author
Kishimoto, Taishiro
Venue
Nature and Science of Sleep
Published
2017-03
Volume
Volume 9
Pages
59-65
ISSN
1179-1608 (ISSN-L)
OpenAlex
W2591636870
Cited by
67
References
30
Citations by year
2026: 7 · 2025: 7 · 2024: 6 · 2023: 7 · 2022: 8 · 2021: 8 · 2020: 8 · 2019: 6 · 2018: 8 · 2017: 2
FWCI
9.40
Type
journal article
Language
en
Open access
Locations
  • Nature and Science of Sleep (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Dove Medical Press (Taylor and Francis Group) (submittedVersion, cc-by-nc)
Topics
  • Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
Keywords
sleep quality, blue light exposure, melatonin suppression, visual fatigue, sleep efficiency, sleep latency, nursing students, motion capture

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.