Point of Care Cardiac Ultrasound Applications in the Emergency Department and Intensive Care Unit - A Review
Open accessThe DOI matches its Crossref record; 72 of the 72 references it cites were found in a registry or an index.
Abstract
The use of point of care echocardiography by non-cardiologist in acute care settings such as the emergency department (ED) or the intensive care unit (ICU) is very common. Unlike diagnostic echocardiography, the scope of such point of care exams is often restricted to address the clinical questions raised by the patient’s differential diagnosis or chief complaint in order to inform immediate management decisions. In this article, an overview of the most common applications of this focused echocardiography in the ED and ICU is provided. This includes but is not limited to the evaluation of patients experiencing hypotension, cardiac arrest, cardiac trauma, chest pain and patients after cardiac surgery. Keywords: Echocardiography, emergency department, ICU, point of care, ultrasound, Non-cardiologist, HYPOTENSIVE PATIENT, emergency department, TEE, CCPs
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 2×
“In the alternative scenario (where LV function is found to be depressed in a patient who is in shock) enhancing cardiac output with inotropic agents may improve oxygen delivery once the patient is adequately fluid resuscitated [7] [8].”
BackgroundNagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029 · cited 1×
“Tissue Doppler imaging, a technique for measuring the velocity of myocardial tissue, is a key component in the assessment of diastolic function in echocardiography laboratories [110,111].”
MethodOmmen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Antithrombotic Therapy for Venous Thromboembolic Disease
Hyers, T. M., Agnelli, G., Hull, R. D., Morris, T. A., Samama, M., Tapson, V., & Weg, J. G. (2001) · Chest · doi:10.1378/chest.119.1_suppl.176s · Cited by 2,042
Antithrombotic Therapy for Venous Thromboembolic Disease
Kearon, C., Kahn, S. R., Agnelli, G., Goldhaber, S., Raskob, G. E., & Comerota, A. J. (2008) · Chest · doi:10.1378/chest.08-0658 · Cited by 1,996 · cited 1×
“Though these findings are associated with increased risk of death,[45] which may suggest an increased role for aggressive therapy such as thrombolysis,[46,47] the absence of such findings is insufficient to rule out PE entirely.”
BackgroundMoore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788 · cited 1×
“Readers interested in the broader scope of point of care ultrasound, as used in the ICU, ED and beyond, may enjoy the recent review by Moore and Copel [5].”
Wells, P. S., Anderson, D. R., Rodger, M., Stiell, I., Dreyer, J. F., Barnes, D., Forgie, M., Kovacs, G., Ward, J., & Kovacs, M. J. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-2-200107170-00010 · Cited by 1,438
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367 · cited 1×
“Traditional methods of volume assessment such as jugular venous pressure, measurement of central venous pressure (CVP), or use of the PAC have each been scrutinized for their lack of accuracy in critically ill patients [13-15].”
MethodKircher, B. J., Himelman, R. B., & Schiller, N. B. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90711-9 · Cited by 1,027 · cited 1×
“Conversely, it has long been known that echocardiographic assessment of the inferior vena cava (IVC) offers a compelling and accurate window in to the right sided filling pressures and overall volume status of the sick [16,17].”
BackgroundThe Diagnosis of Thoracic Aortic Dissection by Noninvasive Imaging Procedures
Nienaber, C. A., von Kodolitsch, Y., Nicolas, V., Siglow, V., Piepho, A., Brockhoff, C., Koschyk, D. H., & Spielmann, R. P. (1993) · New England Journal of Medicine · doi:10.1056/nejm199301073280101 · Cited by 970
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967 · cited 1×
“IVC size and respiratory variation have been shown to correlate well with CVP (and its limitations) or volume responsiveness (the more relevant clinical parameter) in a variety of patient environments [11,18-21].”
BackgroundUltrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852 · cited 1×
“While ultrasound has gained widespread recognition for its ability to improve safety during central venous catheter insertion [117,118], the use of ultrasound to guide pericardiocentesis has also been extensively studied [119-121].”
BackgroundA Bedside Ultrasound Sign Ruling Out Pneumothorax in the Critically III
Lichtenstein, D. A., & Menu, Y. (1995) · Chest · doi:10.1378/chest.108.5.1345 · Cited by 787 · cited 1×
“The use of ultrasound to directly assess the lungs in this setting includes not only the detection of pleural fluid but also the diagnosis of pneumothorax [75,76], pulmonary edema [77,78], and pulmonary consolidation [79].”
MethodLabovitz, A. J., Noble, V. E., Bierig, M., Goldstein, S. A., Jones, R., Kort, S., Porter, T. R., Spencer, K. T., Tayal, V. S., & Wei, K. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.10.005 · Cited by 769
Mayo, P. H., Beaulieu, Y., Doelken, P., Feller-Kopman, D., Harrod, C., Kaplan, A., Oropello, J., Vieillard-Baron, A., Axler, O., Lichtenstein, D., et al. (2009) · Chest · doi:10.1378/chest.08-2305 · Cited by 736 · cited 5×
“Despite this, an international consensus statement includes detection of aortic dissection using TEE among a list of advanced competencies for CCPs [3].”
BackgroundInfluentialPractice Guidelines for Perioperative Transesophageal Echocardiography
(2010) · Anesthesiology · doi:10.1097/aln.0b013e3181c51e90 · Cited by 668
Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic Shock
&NA; (2002) · Survey of Anesthesiology · doi:10.1097/00132586-200210000-00014 · Cited by 662
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612 · cited 1×
“More advanced echocardiographic techniques to assess volume status, including the use of continuous-wave Doppler to observe respiratory variation in volume-time integrals from the LV outflow tract [22] or the use of transesophageal echo (TEE) to assess superior vena cava size variation[23], have also been described wi…”
BackgroundMorrison, L. J., Deakin, C. D., Morley, P. T., Callaway, C. W., Kerber, R. E., Kronick, S. L., Lavonas, E. J., Link, M. S., Neumar, R. W., Otto, C. W., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971051 · Cited by 612 · cited 1×
“Despite calls for the incorporation of cardiac ultrasound into the ubiquitous ACLS algorithms [64,65], there is a paucity of evidence to support that cardiac ultrasound can improve patient outcome, which lead the most recent international guidelines on advanced life support to conclude "there is insufficient evidence…”
BackgroundMeta-analysis of hemodynamic optimization in high-risk patients*
Kern, J. W., & Shoemaker, W. C. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00002 · Cited by 551 · cited 1×
“The belief that improved patient outcomes will result from optimizing these parameters early in the course of critical illness is widely held, yet difficult to prove [80].”
BackgroundFeigenbaum's Echocardiography: Book Review
Artham, S. (2010) · Congenital Heart Disease · doi:10.1111/j.1747-0803.2010.00450.x · Cited by 521
Jones, A. E., Tayal, V. S., Sullivan, D. M., & Kline, J. A. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133017.34137.82 · Cited by 497 · cited 1×
“Taking an average of 6 minutes, the protocol lead clinicians to significantly narrow their differential diagnoses and increased overall diagnostic accuracy [6].”
BackgroundSuperior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476 · cited 1×
“More advanced echocardiographic techniques to assess volume status, including the use of continuous-wave Doppler to observe respiratory variation in volume-time integrals from the LV outflow tract [22] or the use of transesophageal echo (TEE) to assess superior vena cava size variation[23], have also been described wi…”
BackgroundThe comet-tail artifact: an ultrasound sign ruling out pneumothorax
Lichtenstein, D., Mezière, G., Biderman, P., & Gepner, A. (1999) · Intensive Care Medicine · doi:10.1007/s001340050862 · Cited by 466 · cited 1×
“The use of ultrasound to directly assess the lungs in this setting includes not only the detection of pleural fluid but also the diagnosis of pneumothorax [75,76], pulmonary edema [77,78], and pulmonary consolidation [79].”
MethodLichtenstein, D., & Mezière, G. (1998) · Intensive Care Medicine · doi:10.1007/s001340050771 · Cited by 412 · cited 1×
“The use of ultrasound to directly assess the lungs in this setting includes not only the detection of pleural fluid but also the diagnosis of pneumothorax [75,76], pulmonary edema [77,78], and pulmonary consolidation [79].”
MethodUsing heart-lung interactions to assess fluid responsiveness during mechanical ventilation.
Michard, F., & Teboul, J. (2000) · Critical Care · doi:10.1186/cc710 · Cited by 409 · cited 1×
“The variation of specific parameters (such as vena cava diameter or LV stroke volume) may be measured in response to various stimuli such as volume infusion or changes in intrathoracic volume due to respiratory variation, yielding valuable information as to the state of preload responsiveness [81,82].”
BackgroundThe “lung pulse”: an early ultrasound sign of complete atelectasis
Lichtenstein, D. A., Lascols, N., Prin, S., & Mezière, G. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1930-9 · Cited by 372
Oh, J. K., Seward, J. B., & Tajik, A. J. (2015) · Lippincott Williams & Wilkins eBooks · Cited by 363
Moore, C. L., Rose, G. A., Tayal, V. S., Sullivan, D. M., Arrowood, J. A., & Kline, J. A. (2002) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2002.tb00242.x · Cited by 361
&NA; (2002) · Survey of Anesthesiology · doi:10.1097/00132586-200210000-00008 · Cited by 328
Emergency department echocardiography improves outcome in penetrating cardiac injury
Plummer, D., Brunette, D., ASINGER, R. W., & Ruiz, E. (1992) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)82784-2 · Cited by 307 · cited 2×
“In a very simple retrospective review, Plummer et al evaluated the outcomes of patients with penetrating cardiac injuries before and after the implementation of EP performed echocardiography [1].”
BackgroundBlaivas, M., & Fox, J. C. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb00174.x · Cited by 299 · cited 1×
“With respect to prognosis in particular, there have been several compelling and widely quoted articles which have demonstrated that the absence of cardiac motion at any stage of the resuscitative effort suggests no opportunity for return of spontaneous circulation [61-63].”
BackgroundVignon, P., Mentec, H., Terré, S., Gastinne, H., Guéret, P., & Lemaire, F. (1994) · Chest · doi:10.1378/chest.106.6.1829 · Cited by 269 · cited 1×
“While the majority of mechanically ventilated patients can be satisfactorily imaged via a transthoracic approach, significant failure rates have been described in a variety of ICUbased studies including failure rates as high as 85% in those having undergone cardiac surgery [69-71].”
BackgroundHemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-816cc · Cited by 265 · cited 1×
“In the ICU environment, it has been shown in a series of 183 patients with septic shock that one third of patients suffer myocardial suppression related to their sepsis while the rest generally have hyperdynamic function [33].”
BackgroundStawicki, S. P., Braslow, B. M., Panebianco, N. L., Kirkpatrick, J. N., Gracias, V. H., Hayden, G. E., & Dean, A. J. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.02.062 · Cited by 260 · cited 1×
“IVC size and respiratory variation have been shown to correlate well with CVP (and its limitations) or volume responsiveness (the more relevant clinical parameter) in a variety of patient environments [11,18-21].”
BackgroundEchocardiography in the critically ill: current and potential roles
Price, S., Nicol, E., Gibson, D. G., & Evans, T. W. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-2834-7 · Cited by 258 · cited 1×
“With regards to myocardial contractility, echocardiography provides a reliable tool to assess changes in global and regional LV function in response to therapeutic maneuvers such as inotropic or volume therapy [84].”
MethodTamborini, G., Muratori, M., Brusoni, D., Celeste, F., Maffessanti, F., Caiani, E. G., Alamanni, F., & Pepi, M. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep015 · Cited by 256
Armstrong, A. C. (2009) · Cited by 255
Kline, J. A., Steuerwald, M. T., Marchick, M. R., Hernandez-Nino, J., & Rose, G. A. (2009) · Chest · doi:10.1378/chest.08-2988 · Cited by 248 · cited 1×
“Though these findings are associated with increased risk of death,[45] which may suggest an increased role for aggressive therapy such as thrombolysis,[46,47] the absence of such findings is insufficient to rule out PE entirely.”
BackgroundJardin, F., & Vieillard-Baron, A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1873-1 · Cited by 231 · cited 1×
“In addition to providing reliable images for some of the structural assessments described earlier, TEE has offered a new understanding of the way the heart's function is influenced by positive pressure ventilation [73].”
Salen, P., Melniker, L., Chooljian, C., Rose, J. S., Alteveer, J., Reed, J., & Heller, M. (2005) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2004.11.007 · Cited by 202 · cited 1×
“With respect to prognosis in particular, there have been several compelling and widely quoted articles which have demonstrated that the absence of cardiac motion at any stage of the resuscitative effort suggests no opportunity for return of spontaneous circulation [61-63].”
BackgroundAssessment of the Right Ventricle by Echocardiography: A Primer for Cardiac Sonographers
Horton, K. D., Meece, R., & Hill, J. C. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.04.027 · Cited by 201 · cited 1×
“The difficulties in assessing of right ventricular function [104], even under optimal conditions, are only magnified after cardiac surgery.”
BackgroundEmergency echocardiography to detect pericardial effusion in patients in PEA and near-PEA states
Tayal, V. S., & Kline, J. A. (2003) · Resuscitation · doi:10.1016/s0300-9572(03)00245-4 · Cited by 200 · cited 1×
“In a smaller group of arrested or agonal patients, this prevalence was seen to rise to 40% [29].”
BackgroundMintz, G. S., Kotler, M. N., Parry, W. R., Iskandrian, A. S., & Kane, S. A. (1981) · Circulation · doi:10.1161/01.cir.64.5.1018 · Cited by 181 · cited 1×
“Conversely, it has long been known that echocardiographic assessment of the inferior vena cava (IVC) offers a compelling and accurate window in to the right sided filling pressures and overall volume status of the sick [16,17].”
BackgroundLamia, B., Maizel, J., Ochagavia, A., Chemla, D., Osman, D., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819f13d0 · Cited by 178 · cited 1×
“Although detection of myocardial ischemia is, as previously discussed, usually beyond the scope of point of care echocardiography, it has been demonstrated that this phenomenon can be readily detected using TEE-derived estimates of LV filling pressures [88].”
BackgroundIntraoperative Determination of Cardiac Output Using Multiplane Transesophageal Echocardiography
Perrino, A. C., Harris, S. N., & Luther, M. A. (1998) · Anesthesiology · doi:10.1097/00000542-199808000-00010 · Cited by 175 · cited 1×
“An accurate, non-invasive measurement of cardiac output (CO) is often considered to be the holy grail of hemodynamic monitoring, and can be estimated both by TTE and TEE [114,115].”
BackgroundSalen, P., O'Connor, R., Sierzenski, P., Passarello, B., Pancu, D., Melanson, S., Arcona, S., Reed, J., & Heller, M. (2001) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2001.tb00172.x · Cited by 173 · cited 1×
“With respect to prognosis in particular, there have been several compelling and widely quoted articles which have demonstrated that the absence of cardiac motion at any stage of the resuscitative effort suggests no opportunity for return of spontaneous circulation [61-63].”
BackgroundA sonographically guided technique for central venous access.
Teichgräber, U. K.-M., Benter, T., Gebel, M., & Manns, M. P. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.3.9275887 · Cited by 148 · cited 1×
“While ultrasound has gained widespread recognition for its ability to improve safety during central venous catheter insertion [117,118], the use of ultrasound to guide pericardiocentesis has also been extensively studied [119-121].”
BackgroundJones, A. E., Craddock, P. A., Tayal, V. S., & Kline, J. A. (2005) · Shock · doi:10.1097/01.shk.0000186931.02852.5f · Cited by 147
Gunst, M., Ghaemmaghami, V., Sperry, J. L., Robinson, M., O’Keeffe, T., Friese, R. S., & Frankel, H. L. (2008) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181825bc5 · Cited by 140 · cited 1×
“Further, when compared to invasively acquired data that have been frequently used to guide hemodynamic management decisions, a prospective single center trial showed good agreement between a CCP's echo interpretation of LV function and the cardiac index as determined by a pulmonary artery catheter (PAC) in a surgical…”
ResultVignon, P., Hssain, A. A., François, B., Preux, P., Pichon, N., Clavel, M., Frat, J., & Gastinne, H. (2008) · Critical Care · doi:10.1186/cc6792 · Cited by 128 · cited 1×
“Although traditionally measured using a transthoracic approach, the accuracy of TEE-derived estimation of filling pressures in critically ill patients has been studied, and performs well when compared to “gold standard” invasive measures [112,113].”
MethodVieillard‐Baron, A., Qanadli, S. D., Antakly, Y., Fourme, T., Loubières, Y., Jardin, F., & Dubourg, O. (1998) · Intensive Care Medicine · doi:10.1007/s001340050591 · Cited by 127 · cited 1×
“This has contributed to the growing clinical interest regarding use of TEE by CCPs with some European centers having embraced this approach for nearly 20 years [72], as well as the inclusion of TEE as an advanced competency for CCPs seeking competence in critical care ultrasound [3].”
BackgroundAssessment of indices of preload and volume responsiveness
Pinsky, M. R. (2005) · Current Opinion in Critical Care · doi:10.1097/01.ccx.0000158848.56107.b1 · Cited by 125 · cited 1×
“The variation of specific parameters (such as vena cava diameter or LV stroke volume) may be measured in response to various stimuli such as volume infusion or changes in intrathoracic volume due to respiratory variation, yielding valuable information as to the state of preload responsiveness [81,82].”
BackgroundGernoth, C., Wagner, G., Pelosi, P. P., & Luecke, T. (2009) · Critical Care · doi:10.1186/cc7786 · Cited by 118
Echocardiographic observations during inhospital cardiopulmonary resuscitation
Varriale, P., & Maldonado, J. M. (1997) · Critical Care Medicine · doi:10.1097/00003246-199710000-00023 · Cited by 113
Impact of routine use of intraoperative transesophageal echocardiography during cardiac surgery
Couture, P., Denault, A. Y., McKenty, S., Boudreault, D., Plante, F., Perron, R., Babin, D., Normandin, L., & Poirier, N. L. (2000) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03020726 · Cited by 113 · cited 1×
“Although postoperative TEE has been shown to frequently yield valuable information [90], often resulting in adjustments to medical therapy [91], a clear understanding of when and why patients should undergo TEE in the immediate post-operative period remains elusive.”
BackgroundSchefold, J. C., Storm, C., Bercker, S., Pschowski, R., Oppert, M., Krüger, A., & Hasper, D. (2008) · Journal of Emergency Medicine · doi:10.1016/j.jemermed.2007.11.027 · Cited by 112 · cited 1×
“IVC size and respiratory variation have been shown to correlate well with CVP (and its limitations) or volume responsiveness (the more relevant clinical parameter) in a variety of patient environments [11,18-21].”
BackgroundImaging of acute thoracic aortic injury due to blunt trauma: a review.
Patel, N. H., Stephens, K. E., Mirvis, S. E., Shanmuganathan, K., & Mann, F. A. (1998) · Radiology · doi:10.1148/radiology.209.2.9807557 · Cited by 107 · cited 1×
“Similarly, assessment for blunt aortic injury is best carried out by expert TEE exam or computed tomography [59].”
BackgroundJardin, F., BRUN-NEY, D., Hardy, A., Aegerter, P., Beauchet, A., & Bourdarias, J. P. (1991) · CHEST Journal · doi:10.1378/chest.99.1.162 · Cited by 102
Jacques, D., Pinsky, M. R., Severyn, D. A., & Gorcsan, J. (2004) · CHEST Journal · doi:10.1378/chest.126.6.1910 · Cited by 101 · cited 7×
“Despite this, an international consensus statement includes detection of aortic dissection using TEE among a list of advanced competencies for CCPs [3].”
BackgroundInfluentialClinical assessment of central venous pressure in the critically ill.
Cook, D. J. (1990) · American Journal of the Medical Sciences · doi:10.1097/00000441-199003000-00006 · Cited by 92 · cited 1×
“Traditional methods of volume assessment such as jugular venous pressure, measurement of central venous pressure (CVP), or use of the PAC have each been scrutinized for their lack of accuracy in critically ill patients [13-15].”
MethodSalem, K., Mulji, A. S., & Lonn, E. (1999) · PubMed · Cited by 85
Transthoracic Echocardiography Is Not Cost-Effective in Critically Ill Surgical Patients
Cook, C. H., Praba, A. C., Beery, P. R., & Martin, L. C. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200202000-00013 · Cited by 85
Bouhemad, B., Nicolas-Robin, A., Benois, A., Lemaire, S., Goarin, J., & Rouby, J. (2003) · Anesthesiology · doi:10.1097/00000542-200305000-00011 · Cited by 81 · cited 1×
“Although traditionally measured using a transthoracic approach, the accuracy of TEE-derived estimation of filling pressures in critically ill patients has been studied, and performs well when compared to “gold standard” invasive measures [112,113].”
MethodPoelaert, J., Schmidt, C. G., Aken, H. V., Hinder, F., Mollhoff, T., & Loick, H. M. (1999) · Anaesthesia · doi:10.1046/j.1365-2044.1999.00666.x · Cited by 80
Stein, P. D., Matta, F., Janjua, M. S. T., Yaekoub, A. Y., Jaweesh, F., & Alrifai, A. Z. A. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.03.071 · Cited by 75 · cited 1×
“Though these findings are associated with increased risk of death,[45] which may suggest an increased role for aggressive therapy such as thrombolysis,[46,47] the absence of such findings is insufficient to rule out PE entirely.”
BackgroundA suggested curriculum in echocardiography for critical care physicians
Mazraeshahi, R. M., Farmer, J. C., & Porembka, D. T. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000270280.65365.aa · Cited by 54 · cited 1×
“The concept of ruling out severe valvular regurgitation or stenosis in an unstable patient as part of an ICU or ED screening echocardiography protocol has been proposed [122,123], and recognition of massive valvular regurgitation has been recommended as a basic component of screening echocardiography [3].”
BackgroundStewart, W. J., Douglas, P. S., Sagar, K. B., Seward, J. B., Armstrong, W. F., Zoghbi, W. A., Kronzon, I., Mays, J. M., Pearlman, A. S., Schnittger, I., et al. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70177-x · Cited by 46
Piccoli, M., Trambaiolo, P., Salustri, A., Cerquetani, E., Posteraro, A., Pastena, G., Amici, E., Papetti, F., Marincola, E., Carruba, S. L., et al. (2005) · CHEST Journal · doi:10.1378/chest.128.5.3413 · Cited by 35 · cited 1×
“Finally, TEE offers a relatively safe way to investigate an assortment of other common post-operative problems such as pleural effusions [106], diastolic dysfunction [107] localization of the source of embolic phenomenon [108], and the troubleshooting of misplaced pulmonary artery catheters [109].”
BackgroundTan, C., Fraser, A. G., & Warltier, D. C. (2007) · Anesthesiology · doi:10.1097/01.anes.0000270733.26234.56 · Cited by 31 · cited 1×
“Finally, TEE offers a relatively safe way to investigate an assortment of other common post-operative problems such as pleural effusions [106], diastolic dysfunction [107] localization of the source of embolic phenomenon [108], and the troubleshooting of misplaced pulmonary artery catheters [109].”
BackgroundTissue Doppler of Early Mitral Filling Correlates With Simulated Volume Loss in Healthy Subjects
Moore, C. L., Tham, E., Samuels, K. J., McNamara, R. L., Galante, N. J., Stachenfeld, N. S., Shelley, K. H., Dziura, J. D., & Silverman, D. G. (2010) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2010.00906.x · Cited by 9 · cited 1×
“…data that have been frequently used to guide hemodynamic management decisions, a prospective single center trial showed good agreement between a CCP's echo interpretation of LV function and the cardiac index as determined by a pulmonary artery catheter (PAC) in a surgical intensive care unit [12].”
MethodPark, K. J., Oh, Y. J., Chang, H., Sheen, S. S., Choi, J., Lee, K. S., Park, J. H., & Hwang, S. C. (2009) · Journal of Intensive Care Medicine · doi:10.1177/0885066609344952 · Cited by 6 · cited 1×
“Since both LV preload and afterload are influenced by intrathoracic pressure, TEE may also permit the optimization of ventilator variables such as positive end-expiratory pressure (PEEP) [85,86] or the use of recruitment maneuvers [87] by direct visualization of their effects on cardiac size and function.”
Background
Metadata
- Authors
- T. Arntfield, R., & J. Millington, S.
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2012-07-10
- Volume
- 8
- Issue
- 2
- Pages
- 98-108
- ISSN
- 1573-403X (ISSN-L)
- OpenAlex
- W1976276952
- Cited by
- 164
- References
- 72
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.