Biocompatibility Issues with Modern Implants in Bone - A Review for Clinical Orthopedics
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Skeletal defects may result from traumatic, infectious, congenital or neoplastic processes and are considered to be a challenge for reconstructive surgery. Although the autologous bone graft is still the “gold standard”, there is continuing demand for bone substitutes because of associated disadvantages, such as limited supply and potential donor side morbidity [1]. This is not only true for indications in orthopedic and craniomaxillofacial surgeries, but also in repairing endodontic defects and in dental implantology. Before clinical use all new bone substitute materials have to be validated for their osseoconductive and - depending on the composition of the material also –inductive ability, as well as for their long-term biocompatibility in bone. Serving this purpose various bone healing models to test osteocompatibility and inflammatory potential of a novel material on one hand and, on the other hand, non-healing osseous defects to assess the healing potential of a bone substitute material have been developed. Sometimes the use of more than one implantation site can be helpful to provide a wide range of information about a new material [2]. Important markers for biocompatibility and inflammatory responses are the cell types appearing after the implantation of foreign material. There, especially the role of foreign body giant cells (FBGC) is discussed controversial in the pertinent literature, such that it is not clear whether their presence marks an incompatibility of the biomaterial, or whether it belongs to a normal degradation behavior of modern, resorbable biomaterials. This publication is highlighting the different views currently existing about the function of FBGC that appear in response to biomaterials at the implantation sites. A short overview of the general classes of biomaterials, where FBGC may appear as cellular response, is added for clarity, but may not be complete.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Secretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615 · cited 2×
“integrins) [88, 89] and the expression of angiogenic and other growth factors [80].”
BackgroundInflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403 · cited 1×
“Mechanical wear of implants (the smaller the more) [45] activate macrophages to phagocytosis which in turn induces secretion of TNF- , IL-1ß, IL-6 and prostaglandin (PGE)2 [45, 98] that stimulates differentiation of osteoclast precursors into mature osteoclasts [99].”
BackgroundZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · cited 2×
“This view, that FBGC are responsible for the degradation of biomaterials, is further supported by the analyses of retrieved implants showing material surface cracks directly under adherent FBGC [113].”
BackgroundResultMast cells mediate acute inflammatory responses to implanted biomaterials
Tang, L., Jennings, T. A., & Eaton, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8841 · Cited by 272 · cited 2×
“These are transformed monocytes which arrive at the implantation site via a complex pathway of chemotactic and chemokinetic agents like mast cells/histamine [54], and Tumor Necrosis Factor (TNF) -alpha [83] release, complement factors, lymphokines, chemokines, platelet factors, leukotrienes and eventually bacterial fr…”
BackgroundRole for interleukin‐4 in foreign‐body giant cell formation on a poly(etherurethane urea) in vivo
Kao, W. J., McNally, A. K., Hiltner, A., & Anderson, J. M. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291014 · Cited by 154 · cited 2×
“It is likely that the adhesion of macrophages to a surface also is the initial signal to activate the lymphocytes which in turn release molecules that furthermore influence macrophage activity [77] and fusion [81, 102-104].”
BackgroundLymphocytes and the foreign body response: lymphocyte enhancement of macrophage adhesion and fusion
Brodbeck, W. G., MacEwan, M., Colton, E., Meyerson, H., & Anderson, J. M. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30313 · Cited by 146 · cited 2×
“It is likely that the adhesion of macrophages to a surface also is the initial signal to activate the lymphocytes which in turn release molecules that furthermore influence macrophage activity [77] and fusion [81, 102-104].”
BackgroundThe expression of osteoclast markers on foreign body giant cells
Kadoya, Y., Al-Saffar, N., Kobayashi, A., & Revell, P. A. (1994) · Bone and Mineral · doi:10.1016/s0169-6009(08)80211-5 · Cited by 87 · cited 2×
“However, it has to be kept in mind that other authors question whether the TRAP-epitopes as well as other markers (such as calcitonin receptors) are specific for osteoclasts [73].”
BackgroundInflammation, Wound Healing, and the Foreign-Body Response
Anderson, J. M. (2013) · Biomaterials Science · doi:10.1016/b978-0-08-087780-8.00044-9 · Cited by 69
Reactions of cells at implant surfaces
van Blitterswijk, C. A., Bakker, D., Hesseling, S. C., & Koerten, H. K. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90198-j · Cited by 52
Cited by
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Environmental occurrences, fate, and impacts of microplastics
Wu, P., Huang, J., Zheng, Y., Yang, Y., Zhang, Y., He, F., Chen, H., Quan, G., Yan, J., Li, T., et al. (2019) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2019.109612 · Cited by 515
Titanium Alloys for Dental Implants: A Review
W. Nicholson, J. (2020) · Prosthesis · doi:10.3390/prosthesis2020011 · Cited by 461
Metadata
- Authors
- Nuss, K. M. R., & Rechenberg, B. V.
- Venue
- The Open Orthopaedics Journal
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2008-04-25
- Volume
- 2
- Issue
- 1
- Pages
- 66-78
- ISSN
- 1874-3250 (ISSN-L)
- OpenAlex
- W2116926024
- Cited by
- 175
- References
- 10
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.