Abstract
Skeletal defects may result from traumatic, infectious, congenital or neoplastic processes and are considered to be a challenge for reconstructive surgery. Although the autologous bone graft is still the “gold standard”, there is continuing demand for bone substitutes because of associated disadvantages, such as limited supply and potential donor side morbidity [1]. This is not only true for indications in orthopedic and craniomaxillofacial surgeries, but also in repairing endodontic defects and in dental implantology. Before clinical use all new bone substitute materials have to be validated for their osseoconductive and - depending on the composition of the material also –inductive ability, as well as for their long-term biocompatibility in bone. Serving this purpose various bone healing models to test osteocompatibility and inflammatory potential of a novel material on one hand and, on the other hand, non-healing osseous defects to assess the healing potential of a bone substitute material have been developed. Sometimes the use of more than one implantation site can be helpful to provide a wide range of information about a new material [2]. Important markers for biocompatibility and inflammatory responses are the cell types appearing after the implantation of foreign material. There, especially the role of foreign body giant cells (FBGC) is discussed controversial in the pertinent literature, such that it is not clear whether their presence marks an incompatibility of the biomaterial, or whether it belongs to a normal degradation behavior of modern, resorbable biomaterials. This publication is highlighting the different views currently existing about the function of FBGC that appear in response to biomaterials at the implantation sites. A short overview of the general classes of biomaterials, where FBGC may appear as cellular response, is added for clarity, but may not be complete.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994 · cited 1×
“An optimal degradable scaffold material should be degraded and resorbed at the same rate as the tissue grows into the implant and replaces it with natural bone [153] as nondegraded polymers are preventing complete ossification.”
BackgroundSecretory products of macrophages.
Nathan, C. F. (1987) · Journal of Clinical Investigation · doi:10.1172/jci112815 · Cited by 2,615 · cited 2×
“integrins) [88, 89] and the expression of angiogenic and other growth factors [80].”
BackgroundCalcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Das Gesetz der Transformation der Knochen
Wolff, J. (1893) · DMW - Deutsche Medizinische Wochenschrift · doi:10.1055/s-0028-1144106 · Cited by 1,999 · cited 1×
“The studies included in this publication were financed partly (grant for K.N.) by the National Centre of Competence (NCCR) CO-ME, Zurich, Switzerland granted by the Swiss National Funds (SNF).”
The role of the macrophage in wound repair. A study with hydrocortisone and antimacrophage serum.
(1975) · PubMed Central · Cited by 1,437
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058 · cited 1×
“morbidity [1].”
Hench, L. L., & Wilson, J. (1984) · Science · doi:10.1126/science.6093253 · Cited by 982 · cited 1×
“As described earlier this remodelling is mostly coordinated by bone forming cells (osteoblast, osteocytes and periostal cells), monocyte-derived osteoclasts and multinuclear cells.”
BackgroundCalcium orthophosphates in medicine: from ceramics to calcium phosphate cements
Bohner, M. (2000) · Injury · doi:10.1016/s0020-1383(00)80022-4 · Cited by 982 · cited 1×
“However, this is only partially true since also hydroxyapatite substitutes degrade in vivo, albeit much slower compared to ß-TCP or brushite compositions [30, 41, 42].”
BackgroundInterleukin 1, a potential regulator of fibroblast proliferation.
Schmidt, J. A., Mizel, S. B., Cohen, D., & Green, I. (1982) · The Journal of Immunology · doi:10.4049/jimmunol.128.5.2177 · Cited by 831 · cited 1×
“The released factors attract different cell types like additional macrophages, neutrophils, fibroblasts and other cells [89-92].”
BackgroundInflammatory Response to Implants
Anderson, J. M. (1988) · ASAIO Journal · doi:10.1097/00002480-198804000-00005 · Cited by 591 · cited 5×
“On the other hand, they can be the central cellular mediators of the chronic inflammatory response to foreign materials [56] by secreting monocyte chemoattractant protein-1 (MCP-1) contributing to the development of the foreign body reaction [94], disturbing wound healing and ultimately contributing to implant failure.”
BackgroundInfluential
Cited by
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
Kaur, M., & Singh, K. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.04.064 · Cited by 1,451
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Biocompatibility and safety of PLA and its copolymers
Ramot, Y., Haim-Zada, M., Domb, A. J., & Nyska, A. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.03.012 · Cited by 576
Environmental occurrences, fate, and impacts of microplastics
Wu, P., Huang, J., Zheng, Y., Yang, Y., Zhang, Y., He, F., Chen, H., Quan, G., Yan, J., Li, T., et al. (2019) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2019.109612 · Cited by 515
Titanium Alloys for Dental Implants: A Review
W. Nicholson, J. (2020) · Prosthesis · doi:10.3390/prosthesis2020011 · Cited by 461
The material and biological characteristics of osteoinductive calcium phosphate ceramics
Tang, Z., Li, X., Tan, Y., Fan, H., & Zhang, X. (2018) · Regenerative Biomaterials · doi:10.1093/rb/rbx024 · Cited by 297
Phipps, M. C., Clem, W. C., Grunda, J. M., Clines, G. A., & Bellis, S. L. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.080 · Cited by 287
“In order to maximize the success of a biodegradable implant, the implant must support the infiltration of bone cells throughout the thickness of the material, allowing the implant to be replaced with native bone over time through the process of creeping substitution [48].”
BackgroundWillbold, E., Gu, X., Albert, D., Kalla, K., Bobe, K., Brauneis, M., Janning, C., Nellesen, J., Czayka, W., Tillmann, W., et al. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.09.041 · Cited by 254
Biocompatibility assessment of biomaterials used in orthopedic devices: An overview (Review)
Huzum, B., Puha, B., Necoara, R., Gheorghevici, S., Puha, G., Filip, A., Sirbu, P., & Alexa, O. (2021) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2021.10750 · Cited by 253
Biodegradable Magnesium Alloys Developed as Bone Repair Materials: A Review
Liu, C., Ren, Z., Xu, Y., Pang, S., Zhao, X., & Zhao, Y. (2018) · Scanning · doi:10.1155/2018/9216314 · Cited by 246
“The need to induce bone regeneration to repair structural bone deficiencies has inspired research on and development of a vast number of bone repair materials [2, 6].”
BackgroundShort-Term and Long-Term Effects of Orthopedic Biodegradable Implants
Amini, A. R., Wallace, J. S., & Nukavarapu, S. P. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i2.10 · Cited by 181
Mesenchymal stem cell growth on and mechanical properties of fibrin-based biomimetic bone scaffolds
Linsley, C. S., Wu, B. M., & Tawil, B. (2016) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.35840 · Cited by 30
Metadata
- Authors
- Nuss, K. M. R., & Rechenberg, B. V.
- Venue
- The Open Orthopaedics Journal
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2008-04-25
- Volume
- 2
- Issue
- 1
- Pages
- 66-78
- ISSN
- 1874-3250 (ISSN-L)
- OpenAlex
- W2116926024
- Cited by
- 175
- References
- 115
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.