CoChat

Continuous Temperature-Monitoring Socks for Home Use in Patients With Diabetes: Observational Study

Open access
Reyzelman, Alexander M, Koelewyn, Kristopher, Murphy, Maryam, Shen, Xuening, Yu, E, Pillai, Raji, Fu, Jie, Scholten, Henk Jan, Ma, Ran · 2018 · Journal of Medical Internet Research
Cited by 121

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Over 30 million people in the United States (over 9%) have been diagnosed with diabetes. About 25% of people with diabetes will experience a diabetic foot ulcer (DFU) in their lifetime. Unresolved DFUs may lead to sepsis and are the leading cause of lower-limb amputations. DFU rates can be reduced by screening patients with diabetes to enable risk-based interventions. Skin temperature assessment has been shown to reduce the risk of foot ulceration. While several tools have been developed to measure plantar temperatures, they only measure temperature once a day or are designed for clinic use only. In this report, wireless sensor-embedded socks designed for daily wear are introduced, which perform continuous temperature monitoring of the feet of persons with diabetes in the home environment. Combined with a mobile app, this wearable device informs the wearer about temperature increases in one foot relative to the other, to facilitate early detection of ulcers and timely intervention. OBJECTIVE: A pilot study was conducted to assess the accuracy of sensors used in daily wear socks, obtain user feedback on how comfortable sensor-embedded socks were for home use, and examine whether observed temperatures correlated with clinical observations. METHODS: Temperature accuracy of sensors was assessed both prior to incorporation in the socks, as well as in the completed design. The measured temperatures were compared to the reference standard, a high-precision thermostatic water bath in the range 20°C-40°C. A total of 35 patients, 18 years of age and older, with diabetic peripheral neuropathy were enrolled in a single-site study conducted under an Institutional Review Board-approved protocol. This study evaluated the usability of the sensor-embedded socks and correlated the observed temperatures with clinical findings. RESULTS: =1) between temperatures measured and the reference standard was observed. Patients reported that the socks were easy to use and comfortable, ranking them at a median score of 9 or 10 for comfort and ease of use on a 10-point scale. Case studies are presented showing that the temperature differences observed between the feet were consistent with clinical observations. CONCLUSIONS: We report the first use of wireless continuous temperature monitoring for daily wear and home use in patients with diabetes and neuropathy. The wearers found the socks to be no different from standard socks. The temperature studies conducted show that the sensors used in the socks are reliable and accurate at detecting temperature and the findings matched clinical observations. Continuous temperature monitoring is a promising approach as an early warning system for foot ulcers, Charcot foot, and reulceration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2196/12460

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 121

Metadata

Authors
Reyzelman, A. M., Koelewyn, K., Murphy, M., Shen, X., Yu, E., Pillai, R., Fu, J., Scholten, H. J., & Ma, R.
Venue
Journal of Medical Internet Research
Published
2018-12-17
Volume
20
Issue
12
Pages
e12460
ISSN
1438-8871 (ISSN-L)
OpenAlex
W2899355345
Cited by
121
References
1
FWCI
6.48
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.