Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Several wearable devices for physiological and activity monitoring are found on the market, but most of them only allow spot measurements. However, the continuous detection of physiological parameters without any constriction in time or space would be useful in several fields such as healthcare, fitness, and work. This can be achieved with the application of textile technologies for sensorized garments, where the sensors are completely embedded in the fabric. The complete integration of sensors in the fabric leads to several manufacturing techniques that allow dealing with both the technological challenges entailed by the physiological parameters under investigation, and the basic requirements of a garment such as perspiration, washability, and comfort. This review is intended to provide a detailed description of the textile technologies in terms of materials and manufacturing processes employed in the production of sensorized fabrics. The focus is pointed at the technical challenges and the advanced solutions introduced with respect to conventional sensors for recording different physiological parameters, and some interesting textile implementations for the acquisition of biopotentials, respiratory parameters, temperature and sweat are proposed. In the last section, an overview of the main garments on the market is depicted, also exploring some relevant projects under development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107 · cited 7×
“, European Medical Device Regulation, Food and Drug Administration) so as to be produced and marketed in compliance with safety standards [3,4].”
BackgroundInfluentialWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Smart Textiles for Electricity Generation
Chen, G., Li, Y., Bick, M., & Chen, J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00821 · Cited by 931 · cited 1×
“Finally, if garments are used for energy harvesting and electricity generation as well as for physiological measurements, additional specifications are introduced in the manufacturing process [14].”
BackgroundFlexible Electronics: Stretchable Electrodes and Their Future
Huang, S., Liu, Y., Zhao, Y., Ren, Z., & Guo, C. F. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201805924 · Cited by 855 · cited 2×
“Finally, flexible epidermal electronic technologies constitute a new frontier of electrodes for garments: they are both transparent and resistant to different types of mechanical deformation more effectively than fabric electrodes [109].”
BackgroundSmart textiles: Challenges and opportunities
Cherenack, K., & van Pieterson, L. (2012) · Journal of Applied Physics · doi:10.1063/1.4742728 · Cited by 602 · cited 1×
“They are also referred to as “smart textiles” to highlight the ability to accomplish functions that common clothes cannot fulfil [4] in various sectors, among which are healthcare [9] and industry [10].”
BackgroundContact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426 · cited 1×
“Different methods have been recently developed to track the respiratory parameters outside of the clinical environment, and sensorized clothes fit well in this context because of their comfort, practicality, and non-invasiveness [62].”
MethodChest wall and lung volume estimation by optical reflectance motion analysis
Cala, S. J., Kenyon, C. M., Ferrigno, G., Carnevali, P., Aliverti, A., Pedotti, A., Macklem, P. T., & Rochester, D. F. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2680 · Cited by 377 · cited 1×
“[73] compared a smart garment with six piezoresistive elements with the results obtained with optoelectronic plethysmography [74]: the difference between the average respiratory frequency was always lower than 1% and 4% during quiet breathing and tachypnea, respectively.”
ResultSelf-citationFernández-Caramés, T., & Fraga-Lamas, P. (2018) · Electronics · doi:10.3390/electronics7120405 · Cited by 359 · cited 1×
“Overview of some garments available on the market or in research settings [79].”
BackgroundNovel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336 · cited 1×
“2 mm thick taffeta material and benchmarked against standard electrodes, showing a high correlation of ~96% and ~90% from the forehead and hairy sites on the head [48].”
BackgroundWearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315 · cited 9×
“Finally, the electrodes in both cases are represented by the potential Ehc [27].”
BackgroundMethodInfluential
Metadata
- Authors
- Angelucci, A., Cavicchioli, M., Cintorrino, I., Lauricella, G., Rossi, C., Strati, S., & Aliverti, A.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-01-26
- Volume
- 21
- Issue
- 3
- Pages
- 814
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3122925590
- Cited by
- 170
- References
- 74
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques. https://app.cochat.ai/papers/10.3390/s21030814
- The paper
- Angelucci, A., Cavicchioli, M., Cintorrino, I., Lauricella, G., Rossi, C., Strati, S., & Aliverti, A. (2021). Smart Textiles and Sensorized Garments for Physiological Monitoring: A Review of Available Solutions and Techniques. Sensors. https://doi.org/10.3390/s21030814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.