Integrating the Practical Robust Implementation and Sustainability Model With Best Practices in Clinical Decision Support Design: Implementation Science Approach
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Background: Clinical decision support (CDS) design best practices are intended to provide a narrative representation of factors that influence the success of CDS tools. However, they provide incomplete direction on evidence-based implementation principles. Objective: This study aims to describe an integrated approach toward applying an existing implementation science (IS) framework with CDS design best practices to improve the effectiveness, sustainability, and reproducibility of CDS implementations. Methods: We selected the Practical Robust Implementation and Sustainability Model (PRISM) IS framework. We identified areas where PRISM and CDS design best practices complemented each other and defined methods to address each. Lessons learned from applying these methods were then used to further refine the integrated approach. Results: Our integrated approach to applying PRISM with CDS design best practices consists of 5 key phases that iteratively interact and inform each other: multilevel stakeholder engagement, designing the CDS, design and usability testing, thoughtful deployment, and performance evaluation and maintenance. The approach is led by a dedicated implementation team that includes clinical informatics and analyst builder expertise. Conclusions: Integrating PRISM with CDS design best practices extends user-centered design and accounts for the multilevel, interacting, and dynamic factors that influence CDS implementation in health care. Integrating PRISM with CDS design best practices synthesizes the many known contextual factors that can influence the success of CDS tools, thereby enhancing the reproducibility and sustainability of CDS implementations. Others can adapt this approach to their situation to maximize and sustain CDS implementation success.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Qualitative research. Introducing focus groups.
Kitzinger, J. (1995) · BMJ · doi:10.1136/bmj.311.7000.299 · Cited by 6,939 · cited 1×
“When conducting focus groups or interviews with stakeholders, questions should be tailored to the situation [40] and informed by the determinants of effective implementation, which include CDS design best practices.”
BackgroundProtocol Analysis: Verbal Reports as Data
Ericsson, K. A., & Simon, H. A. (1993) · doi:10.7551/mitpress/5657.001.0001 · Cited by 3,537
RE-AIM Planning and Evaluation Framework: Adapting to New Science and Practice With a 20-Year Review
Glasgow, R. E., Harden, S. M., Gaglio, B., Rabin, B., Smith, M. L., Porter, G. C., Ory, M. G., & Estabrooks, P. A. (2019) · Frontiers in Public Health · doi:10.3389/fpubh.2019.00064 · Cited by 2,528
Self-citationExamining the technology acceptance model using physician acceptance of telemedicine technology
Hu, P. J., Chau, P. Y. K., Sheng, O. R. L., & Tam, K. Y. (1999) · Journal of Management Information Systems · doi:10.1080/07421222.1999.11518247 · Cited by 1,951
Bates, D. W., Kuperman, G. J., Wang, S., Gandhi, T., Kittler, A., Volk, L., Spurr, C., Khorasani, R., Tanasijevic, M., & Middleton, B. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1370 · Cited by 1,346
The RE-AIM framework: a systematic review of use over time
Gaglio, B., Shoup, J. A., & Glasgow, R. E. (2013) · American Journal of Public Health · doi:10.2105/ajph.2013.301299 · Cited by 1,029 · cited 2×
“Finally, PRISM builds on the Reach, Effectiveness, Adoption, Implementation, and Maintenance (RE-AIM) framework [31] for key implementation outcome measures.”
BackgroundMethodSelf-citationFeldstein, A. C., & Glasgow, R. E. (2008) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(08)34030-6 · Cited by 987 · cited 2×
“Such a multilevel IS framework assesses the representativeness of participants, the extent to which the intervention needs to be adapted, and its sustainability [27-30].”
BackgroundSelf-citationGrand challenges in clinical decision support
Sittig, D. F., Wright, A., Osheroff, J. A., Middleton, B., Teich, J. M., Ash, J. S., Campbell, E., & Bates, D. W. (2008) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2007.09.003 · Cited by 582
Jaspers, M. W. M., Smeulers, M., Vermeulen, H., & Peute, L. W. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000094 · Cited by 525 · cited 1×
“Up to 95% of CDS tools are dismissed [5], 52%-66% improve process outcomes such as appropriate drug selection, and only 21%-43% lead to improvements in clinical outcomes [6-9].”
BackgroundImproving Outcomes with Clinical Decision Support: An Implementer's Guide, Second Edition
Osheroff, J. (2012) · doi:10.4324/9781498757461 · Cited by 517
Moullin, J. C., Sabater-Hernández, D., Fernandez-Llimos, F., & Benrimoj, S. I. (2015) · Health Research Policy and Systems · doi:10.1186/s12961-015-0005-z · Cited by 392 · cited 3×
“Although there are many IS frameworks [26], we selected the Practical Robust Implementation and Sustainability Model (PRISM) because it: (1) is a process, evaluation and”
BackgroundMethodDrug interaction alert override rates in the Meaningful Use era: No evidence of progress
Bryant, A. D., Fletcher, G. S., & Payne, T. H. (2014) · Applied Clinical Informatics · doi:10.4338/aci-2013-12-ra-0103 · Cited by 172 · cited 1×
“Up to 95% of CDS tools are dismissed [5], 52%-66% improve process outcomes such as appropriate drug selection, and only 21%-43% lead to improvements in clinical outcomes [6-9].”
BackgroundVan de Velde, S., Heselmans, A., Delvaux, N., Brandt, L., Marco-Ruiz, L., Spitaels, D., Cloetens, H., Kortteisto, T., Roshanov, P., Kunnamo, I., et al. (2018) · Implementation Science · doi:10.1186/s13012-018-0790-1 · Cited by 156 · cited 1×
“Initially established by experts in the field, retrospective studies support the potential benefit of applying CDS design best practices [13-16,19,20].”
BackgroundThe Lean Product Playbook: How to Innovate with Minimum Viable Products and Rapid Customer Feedback
Olsen, D. (2015) · doi:10.1002/9781119154822 · Cited by 93
Ray, J. M., Ratwani, R. M., Sinsky, C. A., Frankel, R. M., Friedberg, M. W., Powsner, S. M., Rosenthal, D. I., Wachter, R. M., & Melnick, E. R. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocz098 · Cited by 34 · cited 1×
“Aligned with the learning health care system and agile design principles, the first CDS build scope is not intended to be perfect, rather a first iteration [43].”
Cited by
Glasgow, R. E., Trinkley, K. E., Ford, B., & Rabin, B. A. (2024) · Global Implementation Research and Applications · doi:10.1007/s43477-024-00134-6 · Cited by 70
Self-citationImplementation of Machine Learning Pipelines for Clinical Practice: Development and Validation Study
Kanbar, L. J., Wissel, B., Ni, Y., Pajor, N., Glauser, T., Pestian, J., & Dexheimer, J. W. (2022) · JMIR Medical Informatics · doi:10.2196/37833 · Cited by 30
“The reason integration of these AI pipelines within a clinical health system is challenging is that it requires coordination with the following: (1) key stakeholders and expected end users of the CDS tools; (2) biomedical informatics professionals who design the AI; (3) research information technology (IT) professiona…”
BackgroundInfluentialDecision Support System for Early Diagnosis of Heart Diseases
Ahmed, R. W. (2023) · VFAST Transactions on Software Engineering · doi:10.21015/vtse.v11i2.1470 · Cited by 1
Metadata
- Authors
- Trinkley, K. E., Kahn, M. G., Bennett, T. D., Glasgow, R. E., Haugen, H., Kao, D. P., Kroehl, M. E., Lin, C.-T., Malone, D. C., & Matlock, D. D.
- Venue
- Journal of Medical Internet Research
- Publisher
- JMIR Publications Inc.
- Published
- 2020-10-29
- Volume
- 22
- Issue
- 10
- Pages
- e19676
- ISSN
- 1438-8871 (ISSN-L)
- OpenAlex
- W3095272690
- Cited by
- 57
- References
- 15
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.