Background: Pain is difficult to manage in older adults. It has been recommended that pain management in older adults should include both nonpharmacologic and pharmacologic strategies. Unfortunately, nonadherence to pain medication is more prevalent than nonadherence to any other chronic disease treatment. Technology-based reminders have some benefit for medication adherence, but adherence behavior outcomes have mostly been verified by self-reports. Objective: We aimed to describe objective medication adherence and the latency of medication use after a voice assistant reminder prompted participants to take pain medications for chronic pain. Methods: A total of 15 older adults created a voice assistant reminder for taking scheduled pain medications. A subsample of 5 participants were randomly selected to participate in a feasibility study, in which a medication event monitoring system for pain medications was used to validate medication adherence as a health outcome. Data on the subsample’s self-assessed pain intensity, pain interference, concerns and necessity beliefs about pain medications, self-confidence in managing pain, and medication implementation adherence were analyzed. Results: In the 5 participants who used the medication event monitoring system, the overall latency between voice assistant reminder deployment and the medication event (ie, medication bottle cap opening) was 55 minutes. The absolute latency (before or after the reminder) varied among the participants. The shortest average time taken to open the cap after the reminder was 17 minutes, and the longest was 4.5 hours. Of the 168 voice assistant reminders for scheduled pain medications, 25 (14.6%) resulted in the opening of MEMS caps within 5 minutes of the reminder, and 107 (63.7%) resulted in the opening of MEMS caps within 30 minutes of the reminder. Conclusions: Voice assistant reminders may help cue patients to take scheduled medications, but the timing of medication use may vary. The timing of medication use may influence treatment effectiveness. Tracking the absolute latency time of medication use may be a helpful method for assessing medication adherence. Medication event monitoring may provide additional insight into medication implementation adherence during the implementation of mobile health interventions.

Overview

CoChat Summary

## TL;DR

This feasibility study tested whether voice assistant reminders plus medication event monitoring could objectively capture when older adults with pain actually took scheduled medications. In 5 women, adherence ranged from 82% to 100%, but the timing varied widely: mean overall latency was 55 minutes, with individual average latency ranging from 17 minutes to 4.5 hours.

## Key findings

  • In the monitored subsample of 5 participants, the overall mean latency between voice reminder deployment and MEMS cap opening was 55 minutes (SD 100 minutes).
  • Across 168 voice assistant reminders, 25 (14.6%) were followed by a MEMS cap opening within 5 minutes, and 107 (63.7%) within 30 minutes.
  • Individual adherence percentages ranged from 82% to 100%.
  • The shortest average time to open the cap after the reminder was 17 minutes, and the longest was 4.5 hours; the authors state that timing may be influenced by pain characteristics and beliefs about pain medications.

## Methods

  • Design/sample: Descriptive feasibility study enrolling a convenience sample of 15 community-dwelling adults aged 55 years and older in the Midwest; a random subsample of 5 participants used the monitoring system for 4 weeks.
  • Data collection: Participants created Google Assistant voice reminders for scheduled pain medications; scheduled medication use was tracked with a MEMS Smart Cap; self-reported pain intensity, pain interference, medication necessity/concerns, and self-efficacy were also collected.
  • Analysis: Descriptive statistics were used for questionnaire data, reminder execution times, and MEMS-based adherence percentages; the authors examined absolute latency between reminder time and cap opening time using SPSS version 25.

## Limitations

  • The paper states that the subsample was female only, so the findings need confirmation in men and women with pain.
  • The authors state they could not statistically analyze relationships among variables because the sample was too small.
  • The paper states future studies should use a larger sample, follow participants for several months, and include a control group. A further limitation evident from the text is that the study was restricted to 5 monitored participants, which limits generalizability.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2196/26361

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

4 Valid · 1 Not valid · 6 Not checked · 34 Own results and interpretations

19 more claims

Create a free account to see all 45 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 10
  • Probably not a substantial claim. 14
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

1 of 1

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. O'Leary, K, 2017, AMIA Annu Symp Proc, 2016, 994

Cited by

Metadata

Authors
Shade, M., Rector, K., & Kupzyk, K.
Affiliations
  • University of Nebraska Medical Center (US)
  • University of Iowa (US)
Corresponding author
Shade, Marcia
Venue
JMIR Formative Research
Published
2021-09-28
Volume
5
Issue
9
Pages
e26361
ISSN
2561-326X (ISSN-L)
OpenAlex
W3187911286
Cited by
19
References
31
Citations by year
2026: 3 · 2025: 9 · 2024: 4 · 2023: 3
FWCI
1.71
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • JMIR Formative Research (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Family Practice › Medication Adherence and Compliance
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
  • Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
Keywords
medication adherence, chronic pain, older adults, mobile health intervention, pain management

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.