Evaluation of Subsecond Gated Helical CT for Quantification of Coronary Artery Calcium and Comparison with Electron Beam CT
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Since its introduction early in the 1990s, helical CT has become the predominant technology for obtaining CT images for medical applications. Recent improvements in the temporal resolution of helical CT (subsecond) and the addition of retrospective cardiac gating are combined in this report evaluating cardiac-gated helical CT for quantifying coronary artery calcium. We compare total calcium scores determined on subsecond gated helical CT with the current reference for coronary calcium evaluation, electron beam CT. MATERIALS AND METHODS: We compared total calcium scores obtained using a general purpose, unmodified helical CT scanner with scores obtained using electron beam CT in 36 individuals who were 68+/-11 years old (age range, 41-85 years). RESULTS: Correlation coefficients ranged from 0.97 to 0.98 (Pearson's product moment) and from 0.95 to 0.96 (Spearman's rank order), depending on the coronary calcium scoring method used. Agreement in the classification of participants as "healthy" or "diseased" at threshold total calcium scores of 10, 100, 160, 200, 400, and 680 was, respectively, 94%, 97%, 89%, 92%, 94%, and 100% using the conventional electron beam CT scoring method and an equivalent method with helical CT. CONCLUSION: A general purpose, current generation helical CT scanner equipped for retrospective cardiac gating can accurately quantify coronary calcium, and the results are highly correlated to scores obtained with electron beam CT. As an alternative method for measuring coronary calcium, gated subsecond cardiac helical CT offers greater availability and lower cost, thereby making population-based screening for coronary artery calcium more feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 2×
“[1] uses categoric weighting based on the maximum pixel intensity of each lesion greater than the 130-H threshold multiplied by the area to determine the coronary artery calcium score (Table 2).”
BackgroundMethodThe Cardiovascular Health Study: design and rationale.
Fried, L. P., Borhani, N. O., Enright, P., Furberg, C. D., Gardin, J. M., Kronmal, R. A., Kuller, L. H., Manolio, T. A., Mittelmark, M. B., Newman, A., et al. (1991) · Annals of Epidemiology · doi:10.1016/1047-2797(91)90005-w · Cited by 3,652 · cited 1×
“We measured blood pressure, height, and weight, using the Cardiovascular Health Study protocol for these measures as previously reported [15].”
MethodWexler, L., Brundage, B., Crouse, J., Detrano, R., Fuster, V., Maddahi, J., Rumberger, J., Stanford, W., White, R., & Taubert, K. (1996) · Circulation · doi:10.1161/01.cir.94.5.1175 · Cited by 1,070 · cited 3×
“A 1996 review has summarized data regarding quantification of coronary calcium [2].”
MethodSelf-citationCallister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750 · cited 2×
“[19] stated, “The results of previous analyses of the reproducibility of the TCS [total calcium score] have confirmed the large interscan variability of this measure.”
MethodArad, Y., Spadaro, L. A., Goodman, K., Lledo-Perez, A., Sherman, S., Lerner, G., & Guerci, A. D. (1996) · Circulation · doi:10.1161/01.cir.93.11.1951 · Cited by 521 · cited 4×
“[11] measured coronary calcium with electron beam CT in 1173 asymptomatic subjects and monitored them for 19 months for incidence of coronary heart disease.”
MethodInfluentialDetrano, R., Hsiai, T., Wang, S., Puentes, G., Fallavollita, J., Shields, P., Stanford, W., Wolfkiel, C., Georgiou, D., Budoff, M., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00460-2 · Cited by 434 · cited 1×
“In another study of patients who underwent cardiac catheterization, event rates in individuals with total calcium scores greater than 100 were approximately 3% per year, whereas individuals with scores of less than 100 had event rates of less than 1% year [7].”
BackgroundCoronary Calcium Does Not Accurately Predict Near-Term Future Coronary Events in High-Risk Adults
Detrano, R. C., Wong, N. D., Doherty, T. M., Shavelle, R. M., Tang, W., Ginzton, L. E., Budoff, M. J., & Narahara, K. A. (1999) · Circulation · doi:10.1161/01.cir.99.20.2633 · Cited by 355 · cited 1×
“[23] found that coronary calcium scores did not significantly improve the predictive ability of a risk model based on traditional risk factors for coronary death or nonfatal myocardial infarction.”
BackgroundCoronary artery calcification: assessment with electron beam CT and histomorphometric correlation.
Mautner, G. C., Mautner, S. L., Froehlich, J., Feuerstein, I. M., Proschan, M. A., Roberts, W. C., & Doppman, J. L. (1994) · Radiology · doi:10.1148/radiology.192.3.8058924 · Cited by 348
Janowitz, W. R., Agatston, A. S., Kaplan, G., & Viamonte, M. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90668-3 · Cited by 309
Secci, A., Wong, N., Tang, W., Wang, S., Doherty, T., & Detrano, R. (1997) · Circulation · doi:10.1161/01.cir.96.4.1122 · Cited by 181 · cited 2×
“This method has undergone rigorous testing for reliability [3, 4] and validity [5] and has proven useful in identifying individuals with coronary artery disease [6–9] and those with an increased likelihood of experiencing clinical coronary events [10, 11].”
BackgroundMethod
Cited by
Multi-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Budoff, M. J., Achenbach, S., Blumenthal, R. S., Carr, J. J., Goldin, J. G., Greenland, P., Guerci, A. D., Lima, J. A. C., Rader, D. J., Rubin, G. D., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178458 · Cited by 1,398
Self-citationCarr, J. J., Nelson, J. C., Wong, N. D., McNitt-Gray, M., Arad, Y., Jacobs, D. R., Sidney, S., Bild, D. E., Williams, O. D., & Detrano, R. C. (2005) · Radiology · doi:10.1148/radiol.2341040439 · Cited by 853
Self-citationEthnic Differences in Coronary Calcification: The Multi-Ethnic Study of Atherosclerosis (MESA)
Bild, D. E., Detrano, R., Peterson, D., Guerci, A., Liu, K., Shahar, E., Ouyang, P., Jackson, S., & Saad, M. F. (2005) · Circulation · doi:10.1161/01.cir.0000157730.94423.4b · Cited by 740
Estrogen Therapy and Coronary-Artery Calcification
Manson, J. E., Allison, M. A., Rossouw, J. E., Carr, J. J., Langer, R. D., Hsia, J., Kuller, L. H., Cochrane, B. B., Hunt, J. R., Ludlam, S. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071513 · Cited by 711
Self-citationSchoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Carr, J. J., Jacobs, D. R., Terry, J. G., Shay, C. M., Sidney, S., Liu, K., Schreiner, P. J., Lewis, C. E., Shikany, J. M., Reis, J. P., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.5493 · Cited by 356
Self-citationBlood Pressure Trajectories in Early Adulthood and Subclinical Atherosclerosis in Middle Age
Allen, N. B., Siddique, J., Wilkins, J. T., Shay, C., Lewis, C. E., Goff, D. C., Jacobs, D. R., Liu, K., & Lloyd-Jones, D. (2014) · JAMA · doi:10.1001/jama.2013.285122 · Cited by 345
Self-citationAnkle-Brachial Index and Subclinical Cardiac and Carotid Disease
McDermott, M. M., Liu, K., Criqui, M. H., Ruth, K., Goff, D., Saad, M. F., Wu, C., Homma, S., & Sharrett, A. R. (2005) · American Journal of Epidemiology · doi:10.1093/aje/kwi167 · Cited by 335
Self-citationBerry, J. D., Liu, K., Folsom, A. R., Lewis, C. E., Carr, J. J., Polak, J. F., Shea, S., Sidney, S., O'Leary, D. H., Chan, C., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.800235 · Cited by 318
Self-citationShemesh, J., Henschke, C. I., Shaham, D., Yip, R., Farooqi, A. O., Cham, M. D., McCauley, D. I., Chen, M., Smith, J. P., Libby, D. M., et al. (2010) · Radiology · doi:10.1148/radiol.10100383 · Cited by 318
Goff, D. C., Bertoni, A. G., Kramer, H., Bonds, D., Blumenthal, R. S., Tsai, M. Y., & Psaty, B. M. (2006) · Circulation · doi:10.1161/circulationaha.105.552737 · Cited by 316
Self-citationDetrano, R. C., Anderson, M., Nelson, J., Wong, N. D., Carr, J. J., McNitt-Gray, M., & Bild, D. E. (2005) · Radiology · doi:10.1148/radiol.2362040513 · Cited by 298
Self-citationNettleton, J. A., Schulze, M. B., Jiang, R., Jenny, N. S., Burke, G. L., & Jacobs, D. R. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/88.1.185 · Cited by 251
“Coronary artery calcification (CAC) was measured by computed tomography (CT) with cardiac-gated (at 80% of the R-R interval) electron beam scanners at 3 centers (Imatron C-150; Imatron Inc, San Francisco, CA) (15) and with a prospective electrocardiogram-triggered scan acquisition at 50% of the R-R interval with multi…”
MethodSelf-citationBurke, G. L., Bertoni, A. G., Shea, S., Tracy, R., Watson, K. E., Blumenthal, R. S., Chung, H., & Carnethon, M. R. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.9.928 · Cited by 247
Self-citationLutsey, P. L., Jacobs, D. R., Kori, S., Mayer-Davis, E., Shea, S., Steffen, L. M., Szklo, M., & Tracy, R. (2007) · British Journal of Nutrition · doi:10.1017/s0007114507700715 · Cited by 215
“The scanners are comparable in their ability to measure Ca (Carr et al. 2000).”
BackgroundAboyans, V., Criqui, M. H., McClelland, R. L., Allison, M. A., McDermott, M. M., Goff, D. C., & Manolio, T. A. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.10.032 · Cited by 185
“Computed tomography imaging of the coronary arteries was performed as previously described.(24,29,30) We defined the presence of subclinical coronary disease by the presence of any coronary calcification (CAC score 0).”
MethodSelf-citationHouslay, E. S., Cowell, S. J., Prescott, R. J., Reid, J., Burton, J., Northridge, D. B., Boon, N. A., & Newby, D. E. (2006) · Heart · doi:10.1136/hrt.2005.080929 · Cited by 182
Hong, C., Bae, K. T., & Pilgram, T. K. (2003) · Radiology · doi:10.1148/radiol.2273020369 · Cited by 169
Pletcher, M. J., Bibbins-Domingo, K., Liu, K., Sidney, S., Lin, F., Vittinghoff, E., & Hulley, S. B. (2010) · Annals of Internal Medicine · doi:10.7326/0003-4819-153-3-201008030-00004 · Cited by 129
“The accuracy, comparability, and reproducibility of these methods are described elsewhere (12, 13).”
MethodAlcohol use and cardiovascular disease risk in patients with nonalcoholic fatty liver disease
VanWagner, L. B., Ning, H., Allen, N. B., Ajmera, V., Lewis, C. E., Carr, J. J., Lloyd-Jones, D. M., Terrault, N. A., & Siddique, J. (2017) · Gastroenterology · doi:10.1053/j.gastro.2017.08.012 · Cited by 74
Thematic review series: Patient-Oriented Research. Imaging atherosclerosis: state of the art
Crouse, J. R. (2006) · Journal of Lipid Research · doi:10.1194/jlr.r600012-jlr200 · Cited by 66
“EBCT was first combined with contrast injection to image the lumens of arteries by Moshage et al. (135) in 1995, and contrast-enhanced imaging of arterial lumens with conventional HCT was first described in 2000 (136).”
InfluentialSelf-citation
Metadata
- Authors
- Carr, J. J., Crouse, J. R., Goff, D. C., D'Agostino, R. B., Peterson, N. P., & Burke, G. L.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2000-04
- Volume
- 174
- Issue
- 4
- Pages
- 915-921
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2165748813
- Cited by
- 236
- References
- 27
- FWCI
- 16.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.