Helical CT of the Body: Are Settings Adjusted for Pediatric Patients?
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Our objective was to determine whether adjustments related to patient age are made in the scanning parameters that are determinants of radiation dose for helical CT of pediatric patients. SUBJECTS AND METHODS: This prospective investigation included all body (chest and abdomen) helical CT examinations (n = 58) of neonates, infants, and children (n = 32) referred from outside institutions for whom radiologic consultation was requested. Information recorded included tube current, kilovoltage, collimation, and pitch. Examinations were arbitrarily grouped on the basis of the individual's age: group A, 0-4 years; group B, 5-8 years; group C, 9-12 years; and group D, 13-16 years old. RESULTS: Thirty-one percent (18/58) of the CT examinations were of the chest and 69% (40/58) were of the abdomen. Sixteen percent (9/58) of the CT examinations were combined chest and abdomen. In 22% (2/9) of these combined examinations, tube current was adjusted between the chest and abdomen CT; in one (11%) of these examinations, the tube current was higher for the chest than for the abdomen portion of the CT examination. The mean tube current setting for chest was 213 mA and was 206 mA for the abdomen, with no evident adjustment in tube current based on the age of the patient. Fifty-six percent of the examinations of neonates, infants, or children 8 years old or younger were performed at a collimation of greater than 5 mm and 53% of these examinations were performed using a pitch of 1.0. CONCLUSION: Pediatric helical CT parameters are not adjusted on the basis of the examination type or the age of the child. In particular, these results suggest that pediatric patients may be exposed to an unnecessarily high radiation dose during body CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Self-citationWall, B. F., & Hart, D. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.833.9227222 · Cited by 412
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
The royal college of radiologists
Steiner, R. E. (1980) · Clinical Radiology · doi:10.1016/s0009-9260(80)80176-0 · Cited by 278
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Identification of children with intra-abdominal injuries after blunt trauma
Holmes, J. F., Sokolove, P. E., Brant, W. E., Palchak, M. J., Vance, C. W., Owings, J. T., & Kuppermann, N. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.122900 · Cited by 208
Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R., & Weaver, J. S. (1997) · Radiology · doi:10.1148/radiology.205.3.9393547 · Cited by 194
Rothenberg, L. N., & Pentlow, K. S. (1992) · RadioGraphics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Computer-Simulated Radiation Dose Reduction for Abdominal Multidetector CT of Pediatric Patients
Frush, D. P., Slack, C. C., Hollingsworth, C. L., Bisset, G. S., Donnelly, L. F., Hsieh, J., Lavin-Wensell, T., & Mayo, J. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.5.1791107 · Cited by 174
Self-citationCT of the chest: minimal tube current required for good image quality with the least radiation dose.
Mayo, J. R., Hartman, T. E., Lee, K. S., Primack, S. L., Vedal, S., & Müller, N. L. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.3.7863879 · Cited by 154
Radiation Effective Doses to Patients Undergoing Abdominal CT Examinations
Ware, D. E., Huda, W., Mergo, P. J., & Litwiller, A. L. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr05645 · Cited by 153
Radiation Dose Management: Weighing Risk Versus Benefit
Haaga, J. R. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770289 · Cited by 143
Dose and Pitch Relationship for a Particular Multislice CT Scanner
Mahesh, M., Scatarige, J. C., Cooper, J., & Fishman, E. K. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.6.1771273 · Cited by 138
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · Medical Physics · doi:10.1118/1.1415074 · Cited by 134
Improved Pediatric Multidetector Body CT Using a Size-Based Color-Coded Format
Frush, D. P., Soden, B., Frush, K. S., & Lowry, C. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.3.1780721 · Cited by 107
Self-citationFeigal, D. W. (2002) · International Journal of Trauma Nursing · doi:10.1067/mtn.2002.121511 · Cited by 87
Feasibility of high-resolution, low-dose chest CT in evaluating the pediatric chest
Ambrosino, M. M., Genieser, N. B., Roche, K. J., Kaul, A., & Lawrence, R. M. (1994) · Pediatric Radiology · doi:10.1007/bf02017649 · Cited by 82
Helical CT in children: technical considerations and body applications.
Frush, D. P., & Donnelly, L. F. (1998) · Radiology · doi:10.1148/radiology.209.1.9769810 · Cited by 82
Self-citationHelical body CT: evolution of scanning protocols.
Zeman, R. K., BARON, R. L., Jeffrey, R. B., Klein, J. S., Siegel, M. J., & Silverman, P. M. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.6.9609149 · Cited by 73
Radiation dose reduction in CT of the pediatric pelvis.
Kamel, I. R., Hernandez, R. J., Martin, J. E., Schlesinger, A. E., Niklason, L. T., & Guire, K. E. (1994) · Radiology · doi:10.1148/radiology.190.3.8115611 · Cited by 68
Invited article: Helical/spiral CT scanning: a pediatric radiology perspective
White, K. S. (1996) · Pediatric Radiology · doi:10.1007/bf01403695 · Cited by 62
Frush, D. P. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0684-9 · Cited by 55
Self-citationRogers, L. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.2.1770277 · Cited by 54
Radiation Dose and Somatic Risk from Computed Tomography
Faulkner, K., & Moores, B. M. (1987) · Acta Radiologica · doi:10.1177/028418518702800422 · Cited by 49
Vade, A., Demos, T. C., Olson, M. C., Subbaiah, P., Turbin, R. C., Vickery, K., & Corrigan, K. (1996) · Pediatric Radiology · doi:10.1007/bf03178045 · Cited by 42
Radiation dose reduction in pediatric CT
Robinson, A. E., Hill, E. P., & Harpen, M. D. (1986) · Pediatric Radiology · doi:10.1007/bf02387506 · Cited by 36
Dose Reduction in CT: How Low Can We Go?
Rogers, L. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.2.1790299 · Cited by 35
In x‐ray computed tomography, technique factors should be selected appropriate to patient size
Huda, W., Bushong, S. C., & Hendee, W. R. (2001) · Medical Physics · doi:10.1118/1.1388903 · Cited by 30
Low-Tube-Current Multidetector CT for Children with Suspected Extrinsic Airway Compression
Pacharn, P., Poe, S. A., & Donnelly, L. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.6.1791523 · Cited by 25
Self-citationSolid cancer risks from radiation exposure for the Australian population
Wise, K. N. (2003) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/bf03178458 · Cited by 23
Rosen, N. S. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.3.1770715b · Cited by 12
Future Directions of Congenital Heart Disease Imaging
Geva, T. (2002) · Pediatric Cardiology · doi:10.1007/s00246-001-0062-7 · Cited by 10
Introduction to Seminar in Radiation Dose Reduction
Slovis, T. L. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0795-3 · Cited by 8
Helical CT Angiography of Thoracic Outlet Syndrome
Matsumura, J. S., Yao, J. S. T., & Nemcek, A. A. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.3.1770714 · Cited by 7
Cited by
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Assimos, D., Krambeck, A., Miller, N. L., Monga, M., Murad, M. H., Nelson, C. P., Pace, K. T., Pais, V. M., Pearle, M. S., Preminger, G. M., et al. (2016) · Journal of Urology · doi:10.1016/j.juro.2016.05.090 · Cited by 1,457
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Metadata
- Authors
- Paterson, A., Frush, D. P., & Donnelly, L. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 297-301
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2153746053
- Cited by
- 422
- References
- 36
- FWCI
- 29.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.