Helical CT of the Body: Are Settings Adjusted for Pediatric Patients?
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Our objective was to determine whether adjustments related to patient age are made in the scanning parameters that are determinants of radiation dose for helical CT of pediatric patients. SUBJECTS AND METHODS: This prospective investigation included all body (chest and abdomen) helical CT examinations (n = 58) of neonates, infants, and children (n = 32) referred from outside institutions for whom radiologic consultation was requested. Information recorded included tube current, kilovoltage, collimation, and pitch. Examinations were arbitrarily grouped on the basis of the individual's age: group A, 0-4 years; group B, 5-8 years; group C, 9-12 years; and group D, 13-16 years old. RESULTS: Thirty-one percent (18/58) of the CT examinations were of the chest and 69% (40/58) were of the abdomen. Sixteen percent (9/58) of the CT examinations were combined chest and abdomen. In 22% (2/9) of these combined examinations, tube current was adjusted between the chest and abdomen CT; in one (11%) of these examinations, the tube current was higher for the chest than for the abdomen portion of the CT examination. The mean tube current setting for chest was 213 mA and was 206 mA for the abdomen, with no evident adjustment in tube current based on the age of the patient. Fifty-six percent of the examinations of neonates, infants, or children 8 years old or younger were performed at a collimation of greater than 5 mm and 53% of these examinations were performed using a pitch of 1.0. CONCLUSION: Pediatric helical CT parameters are not adjusted on the basis of the examination type or the age of the child. In particular, these results suggest that pediatric patients may be exposed to an unnecessarily high radiation dose during body CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Self-citationWall, B. F., & Hart, D. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.833.9227222 · Cited by 412
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
The royal college of radiologists
Steiner, R. E. (1980) · Clinical Radiology · doi:10.1016/s0009-9260(80)80176-0 · Cited by 278
An approach for the estimation of effective radiation dose at CT in pediatric patients.
Huda, W., Atherton, J. V., Ware, D. E., & Cumming, W. A. (1997) · Radiology · doi:10.1148/radiology.203.2.9114097 · Cited by 217
Identification of children with intra-abdominal injuries after blunt trauma
Holmes, J. F., Sokolove, P. E., Brant, W. E., Palchak, M. J., Vance, C. W., Owings, J. T., & Kuppermann, N. (2002) · Annals of Emergency Medicine · doi:10.1067/mem.2002.122900 · Cited by 208
Hopper, K. D., King, S. H., Lobell, M. E., TenHave, T. R., & Weaver, J. S. (1997) · Radiology · doi:10.1148/radiology.205.3.9393547 · Cited by 194
Rothenberg, L. N., & Pentlow, K. S. (1992) · RadioGraphics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192
The ALARA Concept in Pediatric CT: Myth or Reality?
Slovis, T. L. (2002) · Radiology · doi:10.1148/radiol.2231012100 · Cited by 180
Cited by
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Assimos, D., Krambeck, A., Miller, N. L., Monga, M., Murad, M. H., Nelson, C. P., Pace, K. T., Pais, V. M., Pearle, M. S., Preminger, G. M., et al. (2016) · Journal of Urology · doi:10.1016/j.juro.2016.05.090 · Cited by 1,457
Sodickson, A., Baeyens, P. F., Andriole, K. P., Prevedello, L. M., Nawfel, R. D., Hanson, R., & Khorasani, R. (2009) · Radiology · doi:10.1148/radiol.2511081296 · Cited by 990
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Frush, D. P., Donnelly, L. F., & Rosen, N. S. (2003) · Pediatrics · doi:10.1542/peds.112.4.951 · Cited by 625
Self-citationAAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Radiation Risk to Children From Computed Tomography
Brody, A. S., Frush, D. P., Huda, W., Brent, R. L., & Radiology, A. T. S. O. (2007) · Pediatrics · doi:10.1542/peds.2007-1910 · Cited by 606
Self-citationEstimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554
Donnelly, L. F., Emery, K. H., Brody, A. S., Laor, T., Gylys-Morin, V. M., Anton, C. G., Thomas, S. R., & Frush, D. P. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760303 · Cited by 480
Self-citationLessons we have learned from our children: cancer risks from diagnostic radiology
Hall, E. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0774-8 · Cited by 415
National Conference on Dose Reduction in CT, with an Emphasis on Pediatric Patients
Linton, O. W., & Mettler, F. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.2.1810321 · Cited by 380
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
GROWTH OF THE THORACIC SPINE IN CONGENITAL SCOLIOSIS AFTER EXPANSION THORACOPLASTY
CAMPBELL, R. M., & HELL-VOCKE, A. K. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200303000-00002 · Cited by 295
Siegel, M. J., Schmidt, B., Bradley, D., Suess, C., & Hildebolt, C. (2004) · Radiology · doi:10.1148/radiol.2332032107 · Cited by 294
Rising Use of CT in Child Visits to the Emergency Department in the United States, 1995–2008
Larson, D. B., Johnson, L. W., Schnell, B. M., Goske, M. J., Salisbury, S. R., & Forman, H. P. (2011) · Radiology · doi:10.1148/radiol.11101939 · Cited by 267
Dose Reduction in Pediatric CT: A Rational Approach
Boone, J. M., Geraghty, E. M., Seibert, J. A., & Wootton-Gorges, S. L. (2003) · Radiology · doi:10.1148/radiol.2282020471 · Cited by 253
Patient Radiation Doses from Adult and Pediatric CT
Huda, W., & Vance, A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.0101 · Cited by 251
“A major effort has recently been undertaken to optimize CT [8, 9] using imaging protocols that explicitly take into account the characteristics of the patient being examined [10–12].”
MethodExposing the Thyroid to Radiation: A Review of Its Current Extent, Risks, and Implications
Sinnott, B., Ron, E., & Schneider, A. B. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0003 · Cited by 246
“If multiphase CT examinations are performed, the dose is increased even more (29, 42).”
BackgroundSemelka, R. C., Armao, D. M., Elias, J., & Huda, W. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20895 · Cited by 238
“It has been reported that multiphase scanning is used for approximately 30% of pediatric patients undergoing body CT, often in three phases (39).”
BackgroundA review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Multiple Diagnostic X-rays for Spine Deformities and Risk of Breast Cancer
Ronckers, C. M., Doody, M. M., Lonstein, J. E., Stovall, M., & Land, C. E. (2008) · Cancer Epidemiology, Biomarkers & Prevention · doi:10.1158/1055-9965.epi-07-2628 · Cited by 176
“Whereas radiation exposure to the breast from diagnostic X-rays has, for the most part, been dramatically reduced over time, the introduction of new technologies (such as computed tomographic scans) that impart higher doses to pediatric and other patients raises new concerns (4).”
BackgroundGuidelines on nuclear medicine imaging in neuroblastoma
Bar-Sever, Z., Biassoni, L., Shulkin, B., Kong, G., Hofman, M. S., Lopci, E., Manea, I., Koziorowski, J., Castellani, R., Boubaker, A., et al. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4070-8 · Cited by 169
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT)
Thierry-Chef, I., Ferro, G., Le Cornet, L., Dabin, J., Istad, T. S., Jahnen, A., Lee, C., Maccia, C., Malchair, F., Olerud, H. M., et al. (2021) · Radiation Research · doi:10.1667/rade-20-00231.1 · Cited by 31
Metadata
- Authors
- Paterson, A., Frush, D. P., & Donnelly, L. F.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2001-02
- Volume
- 176
- Issue
- 2
- Pages
- 297-301
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2153746053
- Cited by
- 422
- References
- 36
- FWCI
- 29.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.