The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Antibacterial biodegradable Mg-Ag alloys
Open accessAbstract
The use of magnesium alloys as degradable metals for biomedical applications is a topic of ongoing research and the demand for multifunctional materials is increasing. Hence, binary Mg-Ag alloys were designed as implant materials to combine the favourable properties of magnesium with the well-known antibacterial property of silver. In this study, three Mg-Ag alloys, Mg2Ag, Mg4Ag and Mg6Ag that contain 1.87 %, 3.82 % and 6.00 % silver by weight, respectively, were cast and processed with solution (T4) and aging (T6) heat treatment. The metallurgical analysis and phase identification showed that all alloys contained Mg4Ag as the dominant β phase. After heat treatment, the mechanical properties of all Mg-Ag alloys were significantly improved and the corrosion rate was also significantly reduced, due to presence of silver. Mg(OH)₂ and MgO present the main magnesium corrosion products, while AgCl was found as the corresponding primary silver corrosion product. Immersion tests, under cell culture conditions, demonstrated that the silver content did not significantly shift the pH and magnesium ion release. In vitro tests, with both primary osteoblasts and cell lines (MG63, RAW 264.7), revealed that Mg-Ag alloys show negligible cytotoxicity and sound cytocompatibility. Antibacterial assays, performed in a dynamic bioreactor system, proved that the alloys reduce the viability of two common pathogenic bacteria, Staphylococcus aureus (DSMZ 20231) and Staphylococcus epidermidis (DSMZ 3269), and the results showed that the killing rate of the alloys against tested bacteria exceeded 90%. In summary, biodegradable Mg-Ag alloys are cytocompatible materials with adjustable mechanical and corrosion properties and show promising antibacterial activity, which indicates their potential as antibacterial biodegradable implant materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aluminum in the Environment and Human Health
Sorenson, J. R. J., Campbell, I. R., Tepper, L. B., & Lingg, R. D. (1974) · Environmental Health Perspectives · doi:10.1289/ehp.7483 · Cited by 280
Cited by
Zinc-based alloys for degradable vascular stent applications
Mostaed, E., Sikora-Jasinska, M., Drelich, J. W., & Vedani, M. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.03.005 · Cited by 565
Antibacterial metals and alloys for potential biomedical implants
Zhang, E., Zhao, X., Hu, J., Wang, R., Fu, S., & Qin, G. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.030 · Cited by 552
Mg bone implant: Features, developments and perspectives
Yang, Y., He, C., Dianyu, E., Yang, W., Qi, F., Xie, D., Shen, L., Peng, S., & Shuai, C. (2020) · Materials & Design · doi:10.1016/j.matdes.2019.108259 · Cited by 433
Zhou, H., Liang, B., Jiang, H., Deng, Z., & Yu, K. (2021) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2021.03.004 · Cited by 377
Li, Y., Liu, L., Wan, P., Zhai, Z., Mao, Z., Ouyang, Z., Yu, D., Sun, Q., Tan, L., Ren, L., et al. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.08.031 · Cited by 286
Metadata
- Authors
- Institute for Material Research, H.-Z. G., Tie, D., Feyerabend, F., Müller, W.-D., Schade, R., Liefeith, K., Kainer, K., & Willumeit, R.
- Venue
- European Cells and Materials
- Publisher
- Forum Multimedia Publishing LLC
- Published
- 2013-06-16
- Volume
- 25
- Pages
- 284-298
- ISSN
- 1473-2262 (ISSN-L)
- OpenAlex
- W2410692204
- Cited by
- 250
- References
- 1
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibacterial biodegradable Mg-Ag alloys. https://app.cochat.ai/papers/10.22203/ecm.v025a20
- The paper
- Institute for Material Research, H.-Z. G., Tie, D., Feyerabend, F., Müller, W.-D., Schade, R., Liefeith, K., Kainer, K., & Willumeit, R. (2013). Antibacterial biodegradable Mg-Ag alloys. European Cells and Materials. https://doi.org/10.22203/ecm.v025a20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.