Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Open accessAbstract
An automated closed-loop insulin delivery system based on subcutaneous glucose sensing and subcutaneous insulin delivery was evaluated in 10 subjects with type 1 diabetes (2 men, 8 women, mean [±SD] age 43.4 ± 11.4 years, duration of diabetes 18.2 ± 13.5 years). Closed-loop control was assessed over ∼30 h and compared with open-loop control assessed over 3 days. Closed-loop insulin delivery was calculated using a model of the β-cell’s multiphasic insulin response to glucose. Plasma glucose was 160 ± 66 mg/dl at the start of closed loop and was thereafter reduced to 71 ± 19 by 1:00 p.m. (preprandial lunch). Fasting glucose the subsequent morning on closed loop was not different from target (124 ± 25 vs. 120 mg/dl, respectively; P > 0.05). Mean glucose levels were not different between the open and closed loop (133 ± 63 vs. 133 ± 52 mg/dl, respectively; P > 0.65). However, glucose was within the range 70–180 mg/dl 75% of the time under closed loop versus 63% for open loop. Incidence of biochemical hypoglycemia (blood glucose <60 mg/dl) was similar under the two treatments. There were no episodes of severe hypoglycemia. The data provide proof of concept that glycemic control can be achieved by a completely automated external closed-loop insulin delivery system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogata, K., & Brewer, J. W. (1971) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3426465 · Cited by 6,358
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Oral Glucose Tolerance Test Minimal Model Indexes of β-Cell Function and Insulin Sensitivity
Breda, E., Cavaghan, M. K., Toffolo, G., Polonsky, K. S., & Cobelli, C. (2001) · Diabetes · doi:10.2337/diabetes.50.1.150 · Cited by 320
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Self-citationAhrén, B., & Holst, J. J. (2001) · Diabetes · doi:10.2337/diabetes.50.5.1030 · Cited by 292
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 270
Challenges facing islet transplantation for the treatment of type 1 diabetes mellitus
Rother, K. I., & Harlan, D. M. (2004) · Journal of Clinical Investigation · doi:10.1172/jci200423235 · Cited by 220
The development of Biostator, a Glucose Controlled Insulin Infusion System (GCIIS).
Clemens, A. H., Chang, P. H., & Myers, R. W. (1977) · PubMed · Cited by 191
A randomized, controlled study of insulin pump therapy in diabetic preschoolers
DiMeglio, L. A., Pottorff, T. M., Boyd, S. R., France, L., Fineberg, N., & Eugster, E. A. (2004) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2004.06.022 · Cited by 170
Elahi, D. (1996) · Diabetes Care · doi:10.2337/diacare.19.3.278 · Cited by 168
Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia
Steil, G. M., Rebrin, K., Hariri, F., Jinagonda, S., Tadros, S. S., Darwin, C. H., & Saad, M. F. (2005) · Diabetologia · doi:10.1007/s00125-005-1852-x · Cited by 148
Self-citationFogt, E. J., Dodd, L. M., Jenning, E., & Clemens, A. H. (1978) · Clinical Chemistry · doi:10.1093/clinchem/24.8.1366 · Cited by 116
Insulin Suppresses Its Own Secretion In Vivo
Argoud, G., Schade, D. S., & Eaton, R. P. (1987) · Diabetes · doi:10.2337/diab.36.8.959 · Cited by 113
Modeling β -Cell Insulin Secretion - Implications for Closed-Loop Glucose Homeostasis
Steil, G. M., Rebrin, K., Janowski, R., Darwin, C. H., & Saad, M. F. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322640999 · Cited by 88
Self-citationCalibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients
Choleau, C., Klein, J. C., Reach, G., Aussedat, B., Demaria-Pesce, V., Wilson, G. S., Gifford, R., & Ward, W. K. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00304-9 · Cited by 76
Panteleon, A. E., Loutseiko, M., Steil, G. M., & Rebrin, K. (2006) · Diabetes · doi:10.2337/db05-1346 · Cited by 65
Self-citationSteil, G. M., Hwu, C.-M., Janowski, R., Hariri, F., Jinagouda, S. D., Darwin, C. H., Tadros, S. S., Rebrin, K., & Saad, M. F. (2004) · Diabetes · doi:10.2337/diabetes.53.5.1201 · Cited by 64
Self-citationControl of Blood Glucose in Diabetics using an Artificial Pancreas*
Kraegen, E. W., Campbell, L. V., Chia, Y. O., Meier, H., & Lazarus, L. (1977) · Australian and New Zealand Journal of Medicine · doi:10.1111/j.1445-5994.1977.tb03687.x · Cited by 57
Insulin Release in Impaired Glucose Tolerance
Breda, E., TOFFOLO, G. M., Polonsky, K. S., & Cobelli, C. (2002) · Diabetes · doi:10.2337/diabetes.51.2007.s227 · Cited by 56
Glucose sensors: toward closed loop insulin delivery
Chia, C. W., & Saudek, C. D. (2004) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2003.12.001 · Cited by 44
Ehrmann, D. A., Breda, E., Cavaghan, M. K., Bajramovic, S., Imperial, J., TOFFOLO, G. M., Cobelli, C., & Polonsky, K. S. (2002) · Diabetologia · doi:10.1007/s00125-002-0776-y · Cited by 41
Fischer, U., Jutzi, E., Bombor, H., Freyse, E., Salzsieder, E., Albrecht, G., Besch, W., & Bruns, W. (1980) · Diabetologia · doi:10.1007/bf00290484 · Cited by 32
Studies With an Artificial Endocrine Pancreas
Albisser, A. M. (1977) · Archives of Internal Medicine · doi:10.1001/archinte.1977.03630170055015 · Cited by 24
Sekigami, T., Shimoda, S., Nishida, K., et al. (2004) · Journal of Artificial Organs · doi:10.1007/s10047-004-0251-2 · Cited by 20
Research works printed but not linked: 1
- Calabrese G, Bueti A, Zega G, Giombolini A, Bellomo G, Antonella MA, Massi-Benedetti M, Brunetti P: Improvement of artificial endocrine pancreas (biostator; GCHS) performance combining feedback controlled insulin administration with a pre-programmed insulin infusion. Horm Metab Res 14:505–507,1982 · doi:10.1055/s-2007-1019062
Cited by
Clinical Practice Guidelines for Multiple Endocrine Neoplasia Type 1 (MEN1)
Thakker, R. V., Newey, P. J., Walls, G. V., Bilezikian, J., Dralle, H., Ebeling, P. R., Melmed, S., Sakurai, A., Tonelli, F., & Brandi, M. L. (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1230 · Cited by 1,477
Cryer, P. E., Axelrod, L., Grossman, A. B., Heller, S. R., Montori, V. M., Seaquist, E. R., & Service, F. J. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2008-1410 · Cited by 1,277
Francis, G. L., Waguespack, S. G., Bauer, A. J., Angelos, P., Benvenga, S., Cerutti, J. M., Dinauer, C. A., Hamilton, J., Hay, I. D., Luster, M., et al. (2015) · Thyroid · doi:10.1089/thy.2014.0460 · Cited by 1,238
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Metadata
- Authors
- Steil, G. M., Rebrin, K., Darwin, C., Hariri, F., & Saad, M. F.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2006-12-01
- Volume
- 55
- Issue
- 12
- Pages
- 3344-3350
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2127456983
- Cited by
- 473
- References
- 24
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.