Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients
Abstract
Unlabelled Calibration, i.e. the transformation in real time of the signal I(t) generated by the glucose sensor at time t into an estimation of glucose concentration G(t), represents a key issue for the development of a continuous glucose monitoring system.Objective To compare two calibration procedures. In the one-point calibration, which assumes that I(o) is negligible, S is simply determined as the ratio I/G, and G(t) = I(t)/S. The two-point calibration consists in the determination of a sensor sensitivity S and of a background current I(o) by plotting two values of the sensor signal versus the concomitant blood glucose concentrations. The subsequent estimation of G(t) is given by G(t) = (I(t)-I(o))/S.Research design and methods A glucose sensor was implanted in the abdominal subcutaneous tissue of nine type 1 diabetic patients during 3 (n = 2) and 7 days (n = 7). The one-point calibration was performed a posteriori either once per day before breakfast, or twice per day before breakfast and dinner, or three times per day before each meal. The two-point calibration was performed each morning during breakfast.Results The percentages of points present in zones A and B of the Clarke Error Grid were significantly higher when the system was calibrated using the one-point calibration. Use of two one-point calibrations per day before meals was virtually as accurate as three one-point calibrations.Conclusion This study demonstrates the feasibility of a simple method for calibrating a continuous glucose monitoring system.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The lag time between blood and subcutaneous tissue glucose concentrations causes further inaccuracies for CGM devices.
“The lag time between blood and subcutaneous tissue glucose concentrations cause further inaccuracies for CGM devices.79–80”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [80]
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667 · see citing works
HEPATOCELLULAR CARCINOMA AND HEPATITIS B VIRUS
Beasley, R. P., Lin, C., Hwang, L., & Chien, C. (1981) · The Lancet · doi:10.1016/s0140-6736(81)90585-7 · Cited by 2,856 · see citing works
The MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393 · see citing works
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314 · see citing works
Garg, S. K., Potts, R. O., Ackerman, N. R., Fermi, S. J., Tamada, J. A., & Chase, H. P. (1999) · Diabetes Care · doi:10.2337/diacare.22.10.1708 · Cited by 200 · see citing works
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186 · see citing works
Self-citationApplication of Chronic Intravascular Blood Glucose Sensor in Dogs
Armour, J. C., Lucisano, J. Y., Bd, M., & Gough, D. A. (1990) · Diabetes · doi:10.2337/diab.39.12.1519 · Cited by 175 · see citing works
The GlucoWatch®biographer: a frequent, automatic and noninvasive glucose monitor
Tierney, M. J., Tamada, J. A., Potts, R. O., Eastman, R. C., Pitzer, K. R., Ackerman, N. R., & Fermi, S. J. (2000) · Annals of Medicine · doi:10.3109/07853890009002034 · Cited by 154 · see citing works
Csöregi, E., Quinn, C. P., Schmidtke, D. W., Lindquist, S., Pishko, M. V., Ye, L., Katakis, I., Hubbell, J. A., & Heller, A. (1994) · Analytical Chemistry · doi:10.1021/ac00091a022 · Cited by 110 · see citing works
Efficacy and Reliability of the Continuous Glucose Monitoring System
Gross, T. M., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214087 · Cited by 108 · see citing works
Moberg, E., Toft, E., Amer, P., & Bolinder, J. (1997) · Diabetologia · doi:10.1007/s001250050827 · Cited by 81 · see citing works
Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion
Schaupp, L., Ellmerer, M., Brunner, G. A., Wutte, A., Sendlhofer, G., Trajanoski, Z., Skrabal, F., Pieber, T. R., & Wach, P. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.2.e401 · Cited by 75 · see citing works
Application of chronic intravascular blood glucose sensor in dogs
Armour, J. C., Lucisano, J. Y., Bd, M., et al. (1990) · Diabetes · doi:10.2337/diabetes.39.12.1519 · Cited by 74 · see citing works
Understanding Error Grid Analysis
Cox, D. J., Gonder-Frederick, L. A., Kovatchev, B. P., Julian, D. M., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.6.911 · Cited by 73 · see citing works
Clinical and statistical evaluation of self-monitoring blood glucose meters.
Poirier, J. Y., Prieur, N. L., Campion, L., Guilhem, I., Allannic, H., & Maugendre, D. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1919 · Cited by 66 · see citing works
Subcutaneous Glucose Concentration in Humans: Real estimation and continuous monitoring
Sternberg, F., Meyerhoff, C., Mennel, F. J., Bischof, F., & Pfeiffer, E. F. (1995) · Diabetes Care · doi:10.2337/diacare.18.9.1266 · Cited by 65 · see citing works
Modification of the sensitivity of glucose sensor implanted into subcutaneous tissue.
Thomé-Duret, V., Gangnerau, M.-N., Zhang, Y., Wilson, G. S., & Reach, G. (1996) · PubMed · Cited by 42 · see citing works
Self-citationA user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm
Aussedat, B., Thomé-Duret, V., Reach, G., Lemmonier, F., Klein, J.-C., Hu, Y., & Wilson, G. S. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00083-3 · Cited by 38 · see citing works
Self-citationVelho, G., Froguel, P., Thévenot, D. R., & Reach, G. (1988) · HAL · Cited by 24 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700 · see citing works
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Self-citationFeasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes
Steil, G. M., Rebrin, K., Darwin, C. H., Hariri, F., & Saad, M. F. (2006) · Diabetes · doi:10.2337/db06-0419 · Cited by 473 · see citing works
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
On‐Body Bioelectronics: Wearable Biofuel Cells for Bioenergy Harvesting and Self‐Powered Biosensing
Jeerapan, I., Sempionatto, J. R., & Wang, J. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906243 · Cited by 242 · see citing works
Noninvasive Glucose Sensing in Aqueous Solutions Using an Active Split-Ring Resonator
Abdolrazzaghi, M., Katchinskiy, N., Elezzabi, A. Y., Light, P. E., & Daneshmand, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3090050 · Cited by 209 · see citing works
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto‐Simón, B., & Voelcker, N. H. (2019) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 205 · see citing works
Continuous Glucose Monitoring: Real-Time Algorithms for Calibration, Filtering, and Alarms
Bequette, B. W. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400222 · Cited by 193 · see citing works
Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., & Feldman, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.031 · Cited by 155 · see citing works
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152 · see citing works
Implantable chemical sensors for real-time clinical monitoring: progress and challenges
Frost, M. C., & Meyerhoff, M. E. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00371-x · Cited by 148 · see citing works
Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology
Hoss, U., & Budiman, E. S. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0025 · Cited by 144 · see citing works
Nanomaterial-mediated Biosensors for Monitoring Glucose
Taguchi, M., Ptitsyn, A. A., McLamore, E. S., & Claussen, J. C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814522799 · Cited by 139 · see citing works
Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2018) · Biosensors · doi:10.3390/bios8010024 · Cited by 122 · see citing works
Evaluation of Factors Affecting CGMS Calibration
Diabetes Research In Children Network (Direcnet) Study Group (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.318 · Cited by 116 · see citing works
Rossetti, P., Bondía, J., Vehı́, J., & Fanelli, C. G. (2010) · Sensors · doi:10.3390/s101210936 · Cited by 115 · see citing works
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107 · see citing works
Mediation of <i>in vivo</i> glucose sensor inflammatory response via nitric oxide release
Gifford, R., Batchelor, M. M., Lee, Y., Gokulrangan, G., Meyerhoff, M. E., & Wilson, G. S. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30359 · Cited by 96 · see citing works
Self-citation“Smart” Continuous Glucose Monitoring Sensors: On-Line Signal Processing Issues
Sparacino, G., Facchinetti, A., & Cobelli, C. (2010) · Sensors · doi:10.3390/s100706751 · Cited by 95 · see citing works
Shi, J. P., Claussen, J. C., McLamore, E. S., Haque, A. U., Jaroch, D., Diggs, A. R., Calvo‐Marzal, P., Rickus, J. L., & Porterfield, D. M. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/35/355502 · Cited by 88 · see citing works
Nonenzymatic Electrochemical Glucose Sensor Based on Novel Copper Film
Sun, F. Y., Li, L., Liu, P., & Lian, Y. (2010) · Electroanalysis · doi:10.1002/elan.201000391 · Cited by 82 · see citing works
McLamore, E. S., Shi, J. P., Jaroch, D., Claussen, J. C., Uchida, A., Jiang, Y., Zhang, W., Donkin, S. S., Banks, M. K., Buhman, K. K., et al. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.09.041 · Cited by 77 · see citing works
Frost, M. C., & Meyerhoff, M. E. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040443 · Cited by 68 · see citing works
Real-time continuous glucose monitoring
Buckingham, B. A., Caswell, K., & Wilson, D. M. (2007) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0b013e32825a675e · Cited by 64 · see citing works
Enhancing the Accuracy of Subcutaneous Glucose Sensors: A Real-Time Deconvolution-Based Approach
Guerra, S., Facchinetti, A., Sparacino, G., Nicolao, G. D., & Cobelli, C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2191782 · Cited by 61 · see citing works
Biosensor system for continuous glucose monitoring in fish
Yonemori, Y., Takahashi, E., Ren, H., Hayashi, T., & Endo, H. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.11.023 · Cited by 61 · see citing works
A Dual-Rate Kalman Filter for Continuous Glucose Monitoring
Kuure-Kinsey, M., Palerm, C. C., & Bequette, B. W. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260057 · Cited by 58 · see citing works
Li, J., Koinkar, P., Fuchiwaki, Y., & Yasuzawa, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.037 · Cited by 45 · see citing works
Sharma, H., Kalita, D., Naskar, U., Mishra, B. K., Kumar, P., & Mirza, K. B. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3289619 · Cited by 43 · see citing works
Design and Testing of an Impedance-Based Sensor for Monitoring Drug Delivery
Johnson, A. M., Sadoway, D. R., Cima, M. J., & Langer, R. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1824045 · Cited by 43 · see citing works
In Vivo Analytical Performance of Nitric Oxide-Releasing Glucose Biosensors
Soto, R. J., Privett, B. J., & Schoenfisch, M. H. (2014) · Analytical Chemistry · doi:10.1021/ac5017425 · Cited by 41 · see citing works
Prevention of Hypoglycemia Using Risk Assessment With a Continuous Glucose Monitoring System
Choleau, C., Dokládal, P., Klein, J. C., Ward, W. K., Wilson, G. S., & Reach, G. (2002) · Diabetes · doi:10.2337/diabetes.51.11.3263 · Cited by 42 · see citing works
Self-citationYan, Q., Major, T. C., Bartlett, R. H., & Meyerhoff, M. E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.026 · Cited by 41 · see citing works
A miniaturized transcutaneous system for continuous glucose monitoring
Croce, R. A., Vaddiraju, S., Kondo, J., Wang, Y., Zuo, L., Zhu, K., ISLAM, S. K., Burgess, D. J., Papadimitrakopoulos, F., & Jain, F. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9708-x · Cited by 38 · see citing works
Baj-Rossi, C., Kilinc, E. G., Ghoreishizadeh, S. S., Casarino, D., Jost, T. R., Dehollain, C., Grassi, F., Pastorino, L., Micheli, G. D., & Carrara, S. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2359094 · Cited by 38 · see citing works
Yu, X., Littlejohn, E., Quinn, L., Çınar, A., Rashid, M. M., Feng, J., Hobbs, N., Hajizadeh, I., Samadi, S., Sevil, M., et al. (2018) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2018.2843785 · Cited by 35 · see citing works
Jensen, M. H., Christensen, T. F., Tarnow, L., Seto, E., Johansen, M. D., & Hejlesen, O. K. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0069 · Cited by 33 · see citing works
Transdermal amperometric biosensors for continuous glucose monitoring in diabetes
Liu, Y., Li, Y., & Cui, Y. (2022) · Talanta · doi:10.1016/j.talanta.2022.124033 · Cited by 29 · see citing works
Wireless Biosensor System for Real-Time L-Lactic Acid Monitoring in Fish
Hibi, K., Hatanaka, K., Takase, M., Ren, H., & Endo, H. (2012) · Sensors · doi:10.3390/s120506269 · Cited by 29 · see citing works
Calibration algorithms for continuous glucose monitoring systems based on interstitial fluid sensing
Sun, T., Liu, J., & Chen, C. J. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116450 · Cited by 28 · see citing works
Mahmoudi, Z., Johansen, M. D., Christiansen, J. S., & Hejlesen, O. K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814531356 · Cited by 28 · see citing works
In vivo calibration of the subcutaneous amperometric glucose sensors using a non-enzyme electrode
Jeong, R.-A., Hwang, J. Y., Joo, S., Chung, T. D., Park, S., Kang, S. K., Lee, W., & Kim, H. C. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00219-7 · Cited by 28 · see citing works
Wireless biosensor system for real-time cholesterol monitoring in fish “Nile tilapia”
Yoneyama, Y., Yonemori, Y., Murata, M., Ohnuki, H., Hibi, K., Hayashi, T., Ren, H., & Endo, H. (2009) · Talanta · doi:10.1016/j.talanta.2009.08.014 · Cited by 27 · see citing works
Jensen, M. H., Christensen, T. F., Tarnow, L., Mahmoudi, Z., Johansen, M. D., & Hejlesen, O. K. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700116 · Cited by 26 · see citing works
Measurement delay associated with the Guardian® RT continuous glucose monitoring system
Wei, C., Lunn, D. J., Acerini, C. L., Allen, J. M., Larsen, A. M., Wilinska, M. E., Dunger, D. B., & Hovorka, R. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02887.x · Cited by 23 · see citing works
Wireless monitoring of blood glucose levels in flatfish with a needle biosensor
Endo, H., Takahashi, E., Murata, M., Ohnuki, H., Ren, H., Tsugawa, W., & Sode, K. (2010) · Fisheries Science · doi:10.1007/s12562-010-0256-0 · Cited by 21 · see citing works
Jensen, M. H., Mahmoudi, Z., Christensen, T. F., Tarnow, L., Seto, E., Johansen, M. D., & Hejlesen, O. K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813511744 · Cited by 20 · see citing works
Accuracy Evaluation of a New Real-Time Continuous Glucose Monitoring Algorithm in Hypoglycemia
Mahmoudi, Z., Jensen, M. H., Johansen, M. D., Christensen, T. F., Tarnow, L., Christiansen, J. S., & Hejlesen, O. K. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0043 · Cited by 20 · see citing works
Choleau, C., Aubert, C., Cahané, M., & Reach, G. (2008) · Diabetes & Metabolism · doi:10.1016/j.diabet.2007.12.002 · Cited by 20 · see citing works
Self-citationYoussef, J. E., Castle, J. R., Engle, J. M., Massoud, R. G., & Ward, W. K. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0020 · Cited by 17 · see citing works
Self-citationAhmed, S., Dack, C., Farace, G., Rigby, G., & Vadgama, P. M. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.01.065 · Cited by 16 · see citing works
Lab-on-a-Bird: Biophysical Monitoring of Flying Birds
Gümüş, A., Lee, S., Ahsan, S. S., Karlsson, K., Gabrielson, R. M., Guglielmo, C. G., Winkler, D. W., & Erickson, D. (2015) · PLoS ONE · doi:10.1371/journal.pone.0123947 · Cited by 15 · see citing works
Development of mediator-type biosensor to wirelessly monitor whole cholesterol concentration in fish
Takase, M., Murata, M., Hibi, K., Huifeng, R., & Endo, H. (2013) · Fish Physiology and Biochemistry · doi:10.1007/s10695-013-9851-1 · Cited by 15 · see citing works
Takase, M., Yoneyama, Y., Murata, M., Hibi, K., Ren, H., & Endo, H. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5894-x · Cited by 13 · see citing works
Electrochemical Glucose Biosensors for Diabetes Care
Ocvirk, G., Buck, H., & DuVall, S. H. (2016) · Bioanalytical reviews · doi:10.1007/11663_2016_3 · Cited by 13 · see citing works
Introduction to the Glucose Sensing Problem
Wilson, G. S., & Zhang, Y. (2009) · doi:10.1002/9780470567319.ch1 · Cited by 13 · see citing works
Self-citationBeyer, U., Fleischer, A., Kage, A., Haueter, U., & EHWALD, R. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00067-8 · Cited by 12 · see citing works
Jia, Z., Huang, L., Liu, H., Huang, Y., Li, W., Pi, X., & Zheng, X. (2019) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-019-03142-7 · Cited by 11 · see citing works
Engineered PQQ Glucose Dehydrogenase‐Based Enzyme Sensor for Continuous Glucose Monitoring
Okuda‐Shimazaki, J., Wakai, J., Igarashi, S., & Sode, K. (2004) · Analytical Letters · doi:10.1081/al-120039430 · Cited by 11 · see citing works
In Vivo Evaluation of Fine Needle Amperometric Glucose Sensors Implanted in Rabbit's Blood Vessel
Edagawa, K., Fuchiwaki, Y., & Yasuzawa, M. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.016402jes · Cited by 9 · see citing works
Preclinical Performance Evaluation of Percutaneous Glucose Biosensors
Soto, R. J., & Schoenfisch, M. H. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815590628 · Cited by 8 · see citing works
Hover, L. C. G., Stedeford, T. J., & Vigneulle, R. M. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.213 · Cited by 8 · see citing works
Sensor Biocompatibility and Biofouling in Real‐Time Monitoring
Voskerician, G., & Anderson, J. M. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs1370 · Cited by 8 · see citing works
Frost, M. C., Wolf, A. K., & Meyerhoff, M. E. (2013) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737302-00129 · Cited by 6 · see citing works
Şeker, S., & Becerik, İ. (2004) · Electroanalysis · doi:10.1002/elan.200302974 · Cited by 6 · see citing works
Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00009-0 · Cited by 5 · see citing works
Electrochemical Systems for Healthcare Applications
Manickam, P., Kanagavel, V., Sonawane, A., Thipperudraswamy, S. P., & Bhansali, S. (2019) · Wiley eBooks · doi:10.1002/9781119611103.ch20 · Cited by 5 · see citing works
An electrochemical continuous glucose monitoring sensor utilizing ferrocene-derivative as a mediator
Nayak, K. K., Dorai, V. K., Pradhan, R. K., Jhunjhunwala, S., & Bhat, N. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113795 · Cited by 4 · see citing works
Continuous Glucose Monitoring with Real-Time Readings
Mohan, V., Ranjit Unnikrishnan, I., & Mithal, A. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_1_22 · Cited by 4 · see citing works
Pilot Study of a Prototype Minimally Invasive Intradermal Continuous Glucose Monitor
Weinstock, R. S., Bristol, S., Armenia, A., Gesswein, A. C., Bequette, B. W., & Willis, J. P. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600627 · Cited by 3 · see citing works
Mahmoudi, Z., Johansen, M. D., Nørgaard, H. H., Andersen, S., Pedersen‐Bjergaard, U., Tarnow, L., Christiansen, J. S., & Hejlesen, O. K. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815587935 · Cited by 2 · see citing works
Multimodel Approaches for Plasma Glucose Estimation in Continuous Glucose Monitoring
Barceló-Rico, F. (2012) · Cited by 2 · see citing works
Polyaniline Working Electrodes For Glucose Sensing
Mihăilescu, C.-M., Moldovan, C. A., Brașoveanu, C., Savin, M., Dinulescu, S., Fîrtat, B., Codreanu, C., Ceauşu, I., & Stanciu, I. (2019) · CAS proceedings · doi:10.1109/smicnd.2019.8923837 · Cited by 1 · see citing works
Impact of Continuous Glucose Monitoring System on Model Based Glucose Control
Chen, X. (2007) · UC Research Repository (University of Canterbury) · doi:10.26021/3448 · Cited by 1 · see citing works
Glucose variability assessment in diabetes mellitus monitoring and control
Fabris, C. (2015) · Padua@research (University of Padova)
Requirements for an Invasive Sensor
Córcoles, E. P., & Boutelle, M. G. (2013) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-00360-3_3
- Authors
- Choleau, C., Klein, J. C., Reach, G., Aussedat, B., Demaria-Pesce, V., Wilson, G. S., Gifford, R., & Ward, W. K.
- Affiliations
- Inserm (FR)
- Centre de Morphologie Mathématique - CMM (FR)
- University of Kansas (US)
- Corresponding author
- Reach, G.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2002-08
- Volume
- 17
- Issue
- 8
- Pages
- 647-654
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2191369865
- Cited by
- 76
- References
- 18
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 1 · 2019: 5 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 6 · 2014: 7 · 2013: 7 · 2012: 6
- FWCI
- 2.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk030718-12, 5r01dk055297-03)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK55297, DK-30718)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Keywords
- continuous glucose monitoring, one-point calibration, two-point calibration, sensor sensitivity, background current, Clarke error grid, type 1 diabetes, sensor accuracy
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Humans, Blood Glucose Self-Monitoring, Biosensing Techniques, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review