Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“As regards IP sensing, we simulated the model proposed by Burnett et al 142 which has an average time delay of 0.68 minutes and a time constant of 5.6 minutes.”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [142]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
The barrier of hypoglycemia in diabetes
Cryer, P. E. (2008) · Diabetes · doi:10.2337/db08-1084 · Cited by 725
Methods for reducing biosensor membrane biofouling
Wisniewski, N., & Reichert, M. (2000) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00148-4 · Cited by 543 · cited 1×
“Thirdly, subcutaneous kinetics have been variably reported to be moderately slow (17–25) and likely worsen with implantation time as the encapsulation develops (26,27).”
BackgroundManagement of occlusion and thrombosis associated with long-term indwelling central venous catheters
Baskin, J. L., Pui, C.-H., Reiss, U., Wilimas, J. A., Metzger, M. L., Ribeiro, R. C., & Howard, S. C. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60220-8 · Cited by 445
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390 · cited 1×
“Further, all measures of subcutaneous kinetics are expected to worsen over implantation time, and subcutaneous sensor performance has been shown to be susceptible to decreases in peripheral perfusion (29,30).”
BackgroundAn Artificial Endocrine Pancreas
Albisser, A. M., Leibel, B. S., Ewart, T. G., Davidovac, Z., Botz, C. K., & Zingg, W. (1974) · Diabetes · doi:10.2337/diab.23.5.389 · Cited by 379
Decreased Epinephrine Responses to Hypoglycemia during Sleep
Jones, T. W., Porter, P., Sherwin, R. S., Davis, E. A., O'Leary, P., Frazer, F., Byrne, G., Stick, S., & Tamborlane, W. V. (1998) · New England Journal of Medicine · doi:10.1056/nejm199806043382303 · Cited by 301
Tanenberg, R. J., Newton, C. A., & Drake, A. J. (2010) · Endocrine Practice · doi:10.4158/ep09260.cr · Cited by 225 · cited 1×
“This is especially vexing during sleep, since sleeping on SQ sensors can cause large inaccuracies (6), and sleeping patients are at high risk for hypoglycemic complications (6-16).”
Background
Cited by
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
A review of optical methods for continuous glucose monitoring
Jernelv, I. L., Mileńko, K., Fuglerud, S. S., Hjelme, D. R., Ellingsen, R., & Aksnes, A. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1486324 · Cited by 145
Latres, E., Finan, D. A., Greenstein, J. L., Kowalski, A. J., & Kieffer, T. J. (2019) · Cell Metabolism · doi:10.1016/j.cmet.2019.02.007 · Cited by 133
Scholten, K., & Meng, E. F. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.022 · Cited by 108
Realizing a Closed-Loop (Artificial Pancreas) System for the Treatment of Type 1 Diabetes
Lal, R., Ekhlaspour, L., Hood, K. K., & Buckingham, B. A. (2019) · Endocrine Reviews · doi:10.1210/er.2018-00174 · Cited by 116
Dassau, E., Renard, E., Place, J., Farret, A., Pelletier, M., Lee, J., Huyett, L. M., Chakrabarty, A., Doyle, F. J., & Zisser, H. C. (2017) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12999 · Cited by 94
Self-citationUtility of different glycemic control metrics for optimizing management of diabetes
Kohnert, K.-D. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i1.17 · Cited by 94
Design and Evaluation of a Robust PID Controller for a Fully Implantable Artificial Pancreas
Huyett, L. M., Dassau, E., Zisser, H., & Doyle, F. J. (2015) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.5b01237 · Cited by 103
Self-citationZhou, S., Chino, Y., Kasama, T., Miyake, R., Mitsuzawa, S., Luan, Y., Ahmad, N. B., Hibino, H., & Takai, M. (2024) · ACS Nano · doi:10.1021/acsnano.4c02997 · Cited by 62
Christiansen, S. C., Fougner, A. L., Stavdahl, Ø., Kölle, K., Ellingsen, R., & Carlsen, S. M. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0263-6 · Cited by 55
Huyett, L. M., Dassau, E., Zisser, H., & Doyle, F. J. (2018) · IEEE Control Systems · doi:10.1109/mcs.2017.2766322 · Cited by 51
Self-citationInterconnected Toroidal Hydrogels for Islet Encapsulation
Ernst, A. U., Wang, L., & Ma, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900423 · Cited by 46
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
van Dijk, P. R., Logtenberg, S. J. J., Gans, R. O. B., Bilo, H. J. G., & Kleefstra, N. (2014) · Clinical Endocrinology · doi:10.1111/cen.12546 · Cited by 44
Wang, L., Marfil‐Garza, B. A., Ernst, A. U., Pawlick, R. L., Pepper, A. R., Okada, K., Epel, B., Viswakarma, N., Kotecha, M., Flanders, J. A., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01145-8 · Cited by 42
Artificial Pancreas: Clinical Study in Latin America Without Premeal Insulin Boluses
Sánchez‐Peña, R., Colmegna, P. H., Garelli, F., Battista, H. D., García-Violini, D., Moscoso-Vásquez, M., Rosales, N., Fushimi, E., Campos-Náñez, E., Breton, M. D., et al. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818786488 · Cited by 41
Prevascularized Retrievable Hybrid Implant to Enhance Function of Subcutaneous Encapsulated Islets
Mridha, A. R., Dargaville, T. R., Dalton, P. D., Carroll, L. M., Morris, M. B., Vaithilingam, V., & Tuch, B. E. (2020) · Tissue Engineering Part A · doi:10.1089/ten.tea.2020.0179 · Cited by 30
Westenfelder, C., Gooch, A. M., Hu, Z.-M., Ahlstrom, J. D., & Zhang, P. (2017) · Stem Cells Translational Medicine · doi:10.1002/sctm.17-0005 · Cited by 27
Taylor, M. J., Gregory, R., Tomlins, P. E., Jacob, D., Hubble, J., & Sahota, T. S. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.12.024 · Cited by 27
Chakrabarty, A., Gregory, J. M., Moore, L. M., Williams, P. E., Farmer, B., Cherrington, A. D., Lord, P., Shelton, B., Cohen, D., Zisser, H., et al. (2019) · Journal of Process Control · doi:10.1016/j.jprocont.2019.01.002 · Cited by 21
Self-citationSekido, K., Sekido, T., Kaneko, A., Hosokawa, M., Sato, A., Sato, Y., Yamazaki, M., & Komatsu, M. (2017) · Endocrine Journal · doi:10.1507/endocrj.ej17-0193 · Cited by 23
Espona‐Noguera, A., Etxebarria‐Elezgarai, J., del Burgo, L. S., Cañibano-Hernández, A., Gurruchaga, H., Blanco, F. J., Orive, G., Hernández, R. M., Benito‐Lopez, F., Ciriza, J., et al. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.01.058 · Cited by 18
Smart Contact Lens for Colorimetric Visualization of Glucose Levels in the Body Fluid
Seo, J., Kang, J., Kim, J., Han, H.-J., Park, M., Shin, M., & Lee, K. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00431 · Cited by 17
The Artificial Pancreas: A Dynamic Challenge
Stavdahl, Ø., Fougner, A. L., Kölle, K., Christiansen, S. C., Ellingsen, R., & Carlsen, S. M. (2016) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2016.07.280 · Cited by 17
Wang, B., Sun, G., Qiao, W., Liu, Y., Qiao, J., Ye, W., Wang, H., Wang, X., Lindquist, R., Wang, Y., et al. (2017) · Journal of Endocrinological Investigation · doi:10.1007/s40618-017-0651-9 · Cited by 16
Effect of sensor location on continuous intraperitoneal glucose sensing in an animal model
Åm, M. K., Kölle, K., Fougner, A. L., Dirnena-Fusini, I., Bösch, P. C., Ellingsen, R., Hjelme, D. R., Stavdahl, Ø., Carlsen, S. M., & Christiansen, S. C. (2018) · PLoS ONE · doi:10.1371/journal.pone.0205447 · Cited by 13
Infrared measurements of glucose in peritoneal fluid with a tuneable quantum cascade laser
Jernelv, I. L., Hjelme, D. R., & Aksnes, A. (2020) · Biomedical Optics Express · doi:10.1364/boe.393617 · Cited by 15
Automated insulin dosing systems: Advances after a century of insulin
Thabit, H., Lal, R., & Leelarathna, L. (2021) · Diabetic Medicine · doi:10.1111/dme.14695 · Cited by 14
Intraperitoneal Glucose Sensing is Sometimes Surprisingly Rapid
Fougner, A. L., Kölle, K., Skjærvold, N. K., Elvemo, N.-A. L., Hjelme, D. R., Ellingsen, R., Carlsen, S. M., & Stavdahl, Ø. (2016) · Modeling Identification and Control A Norwegian Research Bulletin · doi:10.4173/mic.2016.2.4 · Cited by 13
Preliminary Evaluation of a Long-Term Intraperitoneal Glucose Sensor With Flushing Mechanism
Huyett, L. M., Mittal, R., Zisser, H., Luxon, E., Yee, A., Dassau, E., Doyle, F. J., & Burnett, D. R. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640542 · Cited by 12
Self-citationDalla Libera, A., Toffanin, C., Drecogna, M., Galderisi, A., Pillonetto, G., & Cobelli, C. (2023) · APL Bioengineering · doi:10.1063/5.0145446 · Cited by 8
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
Bergenstal, R. M., Heller, A., Breton, M. D., Vigersky, R. A., Brown, S. A., Forlenza, G. P., Sherr, J. L., Hovorka, R., Russell, S. J., Damiano, E. R., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251342239 · Cited by 9
Yin, R., Xin, J., Yang, D., Gao, Y., Zhang, H., Qian, Z., & Zhang, W. (2022) · Polymers · doi:10.3390/polym14204302 · Cited by 9
Fuglerud, S. S., Ellingsen, R., Aksnes, A., & Hjelme, D. R. (2021) · Journal of Biophotonics · doi:10.1002/jbio.202000450 · Cited by 8
The impact of glucose sensing dynamics on the closed-loop artificial pancreas
Huyett, L. M., Dassau, E., Zisser, H., & Doyle, F. J. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172137 · Cited by 9
Self-citationÅm, M. K., Teigen, I. A., Riaz, M., Fougner, A. L., Christiansen, S. C., & Carlsen, S. M. (2023) · Journal of Endocrinological Investigation · doi:10.1007/s40618-023-02193-2 · Cited by 8
Fluoroscopic‐assisted laparoscopic retrieval of retained glucose sensor wire from the omentum
Sang, A. X., Lal, R., August, A. T., Danzer, E., Buckingham, B. A., & Mueller, C. M. (2019) · Clinical Case Reports · doi:10.1002/ccr3.2348 · Cited by 6
Glycemic Key Metrics and the Risk of Diabetes-Associated Complications
Kohnert, K., Heinke, P., Zander, E., Vogt, L., & Salzsieder, E. (2016) · Romanian Journal of Diabetes Nutrition and Metabolic Diseases · doi:10.1515/rjdnmd-2016-0047 · Cited by 5
Why intraperitoneal glucose sensing is sometimes surprisingly rapid and sometimes slow: A hypothesis
Åm, M. K., Fougner, A. L., Ellingsen, R., Hjelme, D. R., Bösch, P. C., Stavdahl, Ø., Carlsen, S. M., & Christiansen, S. C. (2019) · Medical Hypotheses · doi:10.1016/j.mehy.2019.109318 · Cited by 4
Evolution of the Artificial Pancreas: Components and Integration—CGMs, Insulin, and AP Systems
Bergenstal, R. M., Heller, A., Breton, M. D., Vigersky, R. A., Brown, S. A., Forlenza, G. P., Sherr, J. L., Hovorka, R., Russell, S. J., Damiano, E. R., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.18801.rmb · Cited by 5
Use of intraperitoneal insulin delivery for artificial pancreas
Renard, É., Farret, A., & Place, J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00014-4 · Cited by 5
Impact of sensing and infusion site dependent dynamics on insulin bolus based meal compensation
Kölle, K., Fougner, A. L., & Stavdahl, Ø. (2017) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2017.08.1154 · Cited by 3
Wang, B., Qiao, W., Ye, W., Wang, X., Liu, Y., Wang, Y. J., & Xiao, Y. (2017) · Scientific Reports · doi:10.1038/s41598-017-09806-w · Cited by 3
Scoping review of subcutaneous glucose monitoring techniques
Hrubá, E., Kubíček, J., & Augustýnek, M. (2025) · Measurement · doi:10.1016/j.measurement.2025.119940 · Cited by 1
A Personalized Multiscale Modeling Framework for Dose Selection in Precision Medicine
Toroghi, M. K., Cluett, W. R., & Mahadevan, R. (2020) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.0c01070 · Cited by 2
Puglisi, S. C., Mackiewicz, A. L., Ardeshir, A., Garzel, L. M., & Christe, K. L. (2021) · Comparative Medicine · doi:10.30802/aalas-cm-20-000075 · Cited by 1
Glucose(monitoring): from bench to real world experiences
Fokkert, M. J. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.207217778 · Cited by 2
Optical dip probes for near-infrared spectroscopic glucose sensing in peritoneal fluid
Rossvoll, P. (2015) · BIBSYS Brage (BIBSYS (Norway))
Capteur de glucose pour un pancréas artificiel : quel défi ?
Renard, É. (2016) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(16)30191-2
Study of Insulin Attached onto Magnetic Nanoparticles
Bhatti, M. A. (2018) · Cited by 1
Xavier, C., Eugenio, F. A., Malbert, C., Ollagnier, C., Brajon, S., & Gondret, F. (2026) · Veterinary and Animal Science · doi:10.1016/j.vas.2026.100612
Metadata
- Authors
- Burnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D.
- Affiliations
- Theranova (United States) (US)
- University of California, Santa Barbara (US)
- Howard Hughes Medical Institute (US)
- Corresponding author
- Mensh, Brett D.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 2014-06-14
- Volume
- 63
- Issue
- 7
- Pages
- 2498-2505
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- PMC
- PMC4066336
- OpenAlex
- W2162507602
- Cited by
- 52
- References
- 46
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 8 · 2018: 6 · 2017: 8 · 2016: 5 · 2015: 6 · 2014: 1
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Diabetes (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (R43DK093140, R43-DK-93140)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
- Keywords
- continuous glucose monitoring, type 1 diabetes, glucose kinetics, intravenous glucose tolerance test, compartmental modeling, artificial pancreas, pigs
- MeSH terms
- Animals, Ascitic Fluid, Diabetes Mellitus, Female, Glucose, Glucose Tolerance Test, Insulin, Insulin Infusion Systems, Kinetics, Peritoneal Cavity, Swine, Blood Glucose Self-Monitoring, Biosensing Techniques, Pancreas, Artificial, Subcutaneous Tissue
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.