Translating the A1C Assay Into Estimated Average Glucose Values
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—The A1C assay, expressed as the percent of hemoglobin that is glycated, measures chronic glycemia and is widely used to judge the adequacy of diabetes treatment and adjust therapy. Day-to-day management is guided by self-monitoring of capillary glucose concentrations (milligrams per deciliter or millimoles per liter). We sought to define the mathematical relationship between A1C and average glucose (AG) levels and determine whether A1C could be expressed and reported as AG in the same units as used in self-monitoring. RESEARCH DESIGN AND METHODS—A total of 507 subjects, including 268 patients with type 1 diabetes, 159 with type 2 diabetes, and 80 nondiabetic subjects from 10 international centers, was included in the analyses. A1C levels obtained at the end of 3 months and measured in a central laboratory were compared with the AG levels during the previous 3 months. AG was calculated by combining weighted results from at least 2 days of continuous glucose monitoring performed four times, with seven-point daily self-monitoring of capillary (fingerstick) glucose performed at least 3 days per week. RESULTS—Approximately 2,700 glucose values were obtained by each subject during 3 months. Linear regression analysis between the A1C and AG values provided the tightest correlations (AGmg/dl = 28.7 × A1C − 46.7, R2 = 0.84, P < 0.0001), allowing calculation of an estimated average glucose (eAG) for A1C values. The linear regression equations did not differ significantly across subgroups based on age, sex, diabetes type, race/ethnicity, or smoking status. CONCLUSIONS—A1C levels can be expressed as eAG for most patients with type 1 and type 2 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“Moreover, there is substantial interindividual variation in A1C at the same levels of glycemia (20,21), reflecting differences in red cell penetration, glycation, hemoglobin species, red cell half-life, vitamin and medication status, and others factors (22).”
From Screening for Diabetes and Pre-Diabetes With Proposed A1C-Based Diagnostic Criteria (2010) · cites this paper as [20]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The equation generated by the ADAG study is generally considered the most reliable one to date (341).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [341]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“the international A1C-Derived Average Glucose (ADAG) study, which assessed the correlation between A1C and frequent BGM and CGM in 507 adults (83% non-Hispanic White) with type 1, type 2, and no diabetes (13)”
From 6. Glycemic Targets: Standards of Care in Diabetes—2023 (2023) · cites this paper as [13]
The cited source says what the claim attributes to it.
In the citing paper
“In addition, mean glucose values also correlate with A1C in both type 1 and type 2 diabetes as shown in Figure 1 (35,36).”
From Targets for Glycemic Control (2018) · cites this paper as [36]
The cited source says what the claim attributes to it.
In the citing paper
“A1C measurement encompasses a component of both the FPG and postprandial PG.”
From Targets for Glycemic Control (2018) · cites this paper as [36]
6 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Gupta, A., & Uribarri, J. (2016) · Hormone Research in Paediatrics · doi:10.1159/000444053 · Cited by 4,006
Nathan, D. M., Buse, J. B., Davidson, M. B., Ferrannini, E., Holman, R. R., Sherwin, R., & Zinman, B. (2009) · Diabetes Care · doi:10.2337/dc08-9025 · Cited by 3,834
Self-citationThe Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301
Nathan, D. M., Buse, J. B., Davidson, M. B., Heine, R. J., Holman, R. R., Sherwin, R., & Zinman, B. (2006) · Diabetes Care · doi:10.2337/dc06-9912 · Cited by 1,203
Self-citationStandards of Medical Care in Diabetes—2007
American Diabetes Association (2007) · Diabetes Care · doi:10.2337/dc07-s004 · Cited by 1,190
Correlation of Glucose Regulation and Hemoglobin AIcin Diabetes Mellitus
Koenig, R. J., Peterson, C. M., Jones, R. L., Saudek, C., Lehrman, M., & Cerami, A. (1976) · New England Journal of Medicine · doi:10.1056/nejm197608192950804 · Cited by 1,175
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 988
Defining the Relationship Between Plasma Glucose and HbA1c
Rohlfing, C. L., Wiedmeyer, H.-M., Little, R. R., England, J. D., Tennill, A., & Goldstein, D. E. (2002) · Diabetes Care · doi:10.2337/diacare.25.2.275 · Cited by 987
The Clinical Information Value of the Glycosylated Hemoglobin Assay
Nathan, D. M., Singer, D. E., Hurxthal, K., & Goodson, J. D. (1984) · New England Journal of Medicine · doi:10.1056/nejm198402093100602 · Cited by 706
Self-citationHoelzel, W., Weykamp, C., Jeppsson, J.-O., Miedema, K., Barr, J. R., Goodall, I., Hoshino, T., John, W. G., Kobold, U., Little, R., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.024802 · Cited by 690
A desktop guide to Type 2 diabetes mellitus
European Diabetes Policy Group, 1. (1999) · Diabetic Medicine · doi:10.1046/j.1464-5491.1999.00166.x · Cited by 670
Approved IFCC reference method for the measurement of HbA1c in human blood
Jeppsson, J.-O., Kobold, U., Barr, J., Finke, A., Hoelzel, W., Hoshino, T., Miedema, K., Mosca, A., Mauri, P., Paroni, R., et al. (2002) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2002.016 · Cited by 655 · cited 3×
“A new, more stable and specific method of standardization of the A1C assay, which is not intended for use in routine assays, has been developed and proposed to be used for global standardization by the International Federation of Clinical Chemists (11,12).”
MethodGoldstein, D. E., Little, R. R., Lorenz, R. A., Malone, J. I., Nathan, D., Peterson, C. M., & Sacks, D. B. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1761 · Cited by 625
Self-citationEffects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin
Bry, L., Chen, P. C., & Sacks, D. B. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.153 · Cited by 523 · cited 2×
“There are other well-recognized clinical factors, such as anemia and altered erythrocyte turnover, which can affect A1C results measured with all assay methods, and hemoglobinopathies, which interfere with the measurement of A1C with specific methods (22).”
BackgroundRelationship between glycated haemoglobin levels and mean glucose levels over time
Nathan, D. M., Turgeon, H., & Regan, S. (2007) · Diabetologia · doi:10.1007/s00125-007-0803-0 · Cited by 517 · cited 1×
“with the recent study in adults (21) who”
BackgroundSelf-citationAssessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
(2001) · PubMed · Cited by 344
High and low hemoglobin glycation phenotypes in type 1 diabetes
Hempe, J. M., Gomez, R., McCarter, R. J., & Chalew, S. A. (2002) · Journal of Diabetes and its Complications · doi:10.1016/s1056-8727(01)00227-6 · Cited by 322
Consensus Statement on the Worldwide Standardization of the Hemoglobin A1C Measurement
Consensus Committee (2007) · Diabetes Care · doi:10.2337/dc07-9925 · Cited by 303
Svendsen, P. A., Lauritzen, T., S�egaard, U., & Nerup, J. (1982) · Diabetologia · doi:10.1007/bf00260951 · Cited by 144
A desktop guide to Type 2 diabetes mellitus. European Diabetes Policy Group 1999.
(1999) · PubMed · Cited by 127
Relationship of A1C to Glucose Concentrations in Children With Type 1 Diabetes
Diabetes Research in Children Network (DirecNet) Study Group (2008) · Diabetes Care · doi:10.2337/dc07-1835 · Cited by 115
Global Harmonization of Hemoglobin A1c
Sacks, D. B. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.047431 · Cited by 111
Feasibility of Improved Blood Glucose Control in Patients With Insulin-Dependent Diabetes Mellitus
Peterson, C. M., Jones, R. L., Dupuis, A., Levine, B. S., Bernstein, R. K., & O’Shea, M. H. (1979) · Diabetes Care · doi:10.2337/diacare.2.4.329 · Cited by 96
Stork, A. D. M., Kemperman, H., Erkelens, D. W., & Veneman, T. F. (2005) · European Journal of Endocrinology · doi:10.1530/eje.1.01952 · Cited by 95 · cited 1×
“(The Hemocue measurements, recognized as providing values that are equivalent to laboratory measurements, were used primarily to calibrate the CGM [26].”
MethodPsychological Impact of Changing the Scale of Reported HbA1c Results Affects Metabolic Control
Hanås, R. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2110 · Cited by 74
Treviño, G. (2007) · Diabetes Care · doi:10.2337/dc07-1752 · Cited by 52
Murata, G. H., Hoffman, R. M., Wendel, C. S., Shah, J. H., & Duckworth, W. C. (2004) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200406000-00004 · Cited by 27
Cited by
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
International Expert Committee report on the role of the A1c assay in the diagnosis of diabetes
The International Expert Committee (2009) · Diabetes Care · doi:10.2337/dc09-9033 · Cited by 3,185
Standards of medical care in diabetes—2011
American Diabetes Association (2011) · Diabetes Care · doi:10.2337/dc11-s011 · Cited by 2,880
Metadata
- Authors
- Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group
- Affiliations
- Harvard University (US)
- Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
- Steno Hospital, Copenhagen, Denmark
- Corresponding author
- Nathan, David M.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2008-08-01
- Volume
- 31
- Issue
- 8
- Pages
- 1473-1478
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC2742903
- OpenAlex
- W2117343153
- Semantic Scholar
- 609e4b59cc5b2bab4a956a4449b4363b4d17f210
- Cited by
- 1,812
- References
- 32
- Citations by year
- 2026: 100 · 2025: 107 · 2024: 127 · 2023: 100 · 2022: 116 · 2021: 103 · 2020: 115 · 2019: 83 · 2018: 101 · 2017: 106 · 2016: 79 · 2015: 86 · 2014: 109 · 2013: 94 · 2012: 88
- FWCI
- 69.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Diabetes Care (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (submittedVersion)
- VUBIR (Vrije Universiteit Brussel) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- American Diabetes Association
- GlaxoSmithKline
- Bayer HealthCare
- European Foundation for the Study of Diabetes
- Abbott Diabetes Care
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- HbA1c, estimated average glucose, average glucose, type 1 diabetes, type 2 diabetes, continuous glucose monitoring
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Male, Middle Aged, Models, Theoretical, Reference Values, Regression Analysis, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.