Duration of Nocturnal Hypoglycemia Before Seizures
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—Despite a high incidence of nocturnal hypoglycemia documented by the use of continuous glucose monitoring (CGM), there are no reports in the literature of nocturnal hypoglycemic seizures while a patient is wearing a CGM device. RESEARCH DESIGN AND METHODS—In this article, we describe four such cases and assess the duration of nocturnal hypoglycemia before the seizure. RESULTS—In the cases where patients had a nocturnal hypoglycemic seizure while wearing a CGM device, sensor hypoglycemia (<60 mg/dl) was documented on the CGM record for 2.25–4 h before seizure activity. CONCLUSIONS—Even with a subcutaneous glucose lag of 18 min when compared with blood glucose measurements, glucose sensors have time to provide clinically meaningful alarms. Current nocturnal hypoglycemic alarms need to be improved, however, since patients can sleep through the current alarm systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Davis, E. A., Keating, B., Byrne, G. C., Russell, M., & Jones, T. W. (1997) · Diabetes Care · doi:10.2337/diacare.20.1.22 · Cited by 273 · cited 1×
“In children, 75% of hypoglycemic seizures occur at night (2).”
Defective awakening response to nocturnal hypoglycemia in patients with type 1 diabetes mellitus
Schultes, B., Jauch-Chara, K., Gais, S., Hallschmid, M., Reiprich, E., Kern, W., Oltmanns, K. M., Peters, A., Fehm, H. L., & Born, J. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040069 · Cited by 100
Cited by
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Tanenberg, R. J., Newton, C. A., & Drake, A. J. (2010) · Endocrine Practice · doi:10.4158/ep09260.cr · Cited by 225
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180
“(15) documented four episodes of seizures occurring during the night in patients wearing CGM devices, which demonstrated that there were 21⁄4–4 h of low sensor glucose values preceding each seizure.”
Prevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
Self-citationGarg, S., Brazg, R. L., Bailey, T. S., Buckingham, B. A., Slover, R. H., Klonoff, D. C., Shin, J., Welsh, J. B., & Kaufman, F. R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0292 · Cited by 138
Self-citationManaging diabetes in preschool children
Sundberg, F., Barnard, K., Cato, A., de Beaufort, C., DiMeglio, L. A., Dooley, G., Hershey, T., Hitchcock, J., Jain, V., Weissberg-Benchell, J., et al. (2017) · Pediatric Diabetes · doi:10.1111/pedi.12554 · Cited by 91
Sherr, J. L., Palau Collazo, M., Cengiz, E., Michaud, C., Carria, L., Steffen, A. T., Weyman, K., Zgorski, M., Tichy, E., Tamborlane, W. V., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1608 · Cited by 35
“(12) demonstrated that low sensor glucose levels were detected 2–4 h prior to seizures in the middle of the night.”
BackgroundGubitosi-Klug, R. A., Braffett, B. H., Bebu, I., Johnson, M. L., Farrell, K., Kenny, D., Trapani, V. R., Meadema-Mayer, L., Soliman, E. Z., Pop-Busui, R., et al. (2022) · Diabetes Care · doi:10.2337/dc21-0629 · Cited by 31
Temporal occurrences and recurrence patterns of hypoglycemia during hospitalization
Ulmer, B. J., Kara, A., & Mariash, C. N. (2015) · Endocrine Practice · doi:10.4158/ep14355.or · Cited by 28
Metadata
- Authors
- Buckingham, B., Wilson, D. M., Lecher, T., Hanas, R., Kaiserman, K., & Cameron, F.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2008-11-01
- Volume
- 31
- Issue
- 11
- Pages
- 2110-2112
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W1979173973
- Cited by
- 111
- References
- 2
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.