CoChat

Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring

Open access
Dassau, Eyal, Cameron, Fraser, Lee, Hyunjin, Bequette, B. Wayne, Zisser, Howard, Jovanovič, Lois, Chase, H. Peter, Wilson, Darrell M., Buckingham, Bruce A., Doyle, Francis J. · 2010 · Diabetes Care
Cited by 143

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The purpose of this study was to develop an advanced algorithm that detects pending hypoglycemia and then suspends basal insulin delivery. This approach can provide a solution to the problem of nocturnal hypoglycemia, a major concern of patients with diabetes. RESEARCH DESIGN AND METHODS: This real-time hypoglycemia prediction algorithm (HPA) combines five individual algorithms, all based on continuous glucose monitoring 1-min data. A predictive alarm is issued by a voting algorithm when a hypoglycemic event is predicted to occur in the next 35 min. The HPA system was developed using data derived from 21 Navigator studies that assessed Navigator function over 24 h in children with type 1 diabetes. We confirmed the function of the HPA using a separate dataset from 22 admissions of type 1 diabetic subjects. During these admissions, hypoglycemia was induced by gradual increases in the basal insulin infusion rate up to 180% from the subject's own baseline infusion rate. RESULTS: Using a prediction horizon of 35 min, a glucose threshold of 80 mg/dl, and a voting threshold of three of five algorithms to predict hypoglycemia (defined as a FreeStyle plasma glucose readings <60 mg/dl), the HPA predicted 91% of the hypoglycemic events. When four of five algorithms were required to be positive, then 82% of the events were predicted. CONCLUSIONS: The HPA will enable automated insulin-pump suspension in response to a pending event that has been detected prior to severe immediate complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc09-1487

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Dassau, E., Cameron, F., Lee, H., Bequette, B. W., Zisser, H., Jovanovič, L., Chase, H. P., Wilson, D. M., Buckingham, B. A., & Doyle, F. J.
Venue
Diabetes Care
Published
2010-06-01
Volume
33
Issue
6
Pages
1249-1254
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W2167276257
Cited by
143
References
6
FWCI
12.77
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.2337/dc09-1487
The paper
Dassau, E., Cameron, F., Lee, H., Bequette, B. W., Zisser, H., Jovanovič, L., Chase, H. P., Wilson, D. M., Buckingham, B. A., & Doyle, F. J. (2010). Real-Time Hypoglycemia Prediction Suite Using Continuous Glucose Monitoring. Diabetes Care. https://doi.org/10.2337/dc09-1487

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.