OBJECTIVE: This study evaluated the societal cost-effectiveness of continuous glucose monitoring (CGM) in patients with type 1 diabetes (T1D) using multiple insulin injections. RESEARCH DESIGN AND METHODS: In the Multiple Daily Injections and Continuous Glucose Monitoring in Diabetes (DIAMOND) trial, 158 patients with T1D and HbA1c ≥7.5% were randomized in a 2:1 ratio to CGM or control. Participants were surveyed at baseline and 6 months. Within-trial and lifetime cost-effectiveness analyses were conducted. A modified Sheffield T1D policy model was used to simulate T1D complications. The main outcome was cost per quality-adjusted life-year (QALY) gained. RESULTS: Within the 6-month trial, the CGM group had similar QALYs to the control group (0.462 ± 0.05 vs. 0.455 ± 0.06 years, P = 0.61). The total 6-month costs were $11,032 (CGM) vs. $7,236 (control). The CGM group experienced reductions in HbA1c (0.60 ± 0.74% difference in difference [DiD]), P < 0.01), the daily rate of nonsevere hypoglycemia events (0.07 DiD, P = 0.013), and daily test strip use (0.55 ± 1.5 DiD, P = 0.04) compared with the control group. In the lifetime analysis, CGM was projected to reduce the risk of T1D complications and increase QALYs by 0.54. The incremental cost-effectiveness ratio (ICER) was $98,108 per QALY for the overall population. By extending sensor use from 7 to 10 days in a real-world scenario, the ICER was reduced to $33,459 per QALY. CONCLUSIONS: For adults with T1D using multiple insulin injections and still experiencing suboptimal glycemic control, CGM is cost-effective at the willingness-to-pay threshold of $100,000 per QALY, with improved glucose control and reductions in nonsevere hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Economic Costs of Diabetes in the U.S. in 2002
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.3.917 · Cited by 4,147
Sanders, G. D., Neumann, P. J., Basu, A., Brock, D. W., Feeny, D., Krahn, M., Kuntz, K. M., Meltzer, D. O., Owens, D. K., Prosser, L. A., et al. (2016) · JAMA · doi:10.1001/jama.2016.12195 · Cited by 3,069
Nathan, D. M., & for the DCCT/EDIC Research Group (2014) · Diabetes Care · doi:10.2337/dc13-2112 · Cited by 1,832 · cited 5×
“Medical care 3,022 (3,088) 2,478 (1,880, 3,122) 2,921 (3,065) 2,509 (1,909, 3,095) 0.”
BackgroundInfluentialConsolidated Health Economic Evaluation Reporting Standards (CHEERS) statement
Husereau, D., Drummond, M., Petrou, S., Carswell, C., Moher, D., Greenberg, D., Augustovski, F., Briggs, A. H., Mauskopf, J., Loder, E., et al. (2013) · BMJ · doi:10.1136/bmj.f1049 · Cited by 1,776
Valuing health-related quality of life: an EQ-5D-5L value set for England
Devlin, N. J., Shah, K. K., Feng, Y., Mulhern, B., & van Hout, B. (2018) · Health Economics · doi:10.1002/hec.3564 · Cited by 1,356
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Consolidated health economic evaluation reporting standards (CHEERS) statement
Husereau, D., Drummond, M., Petrou, S., Carswell, C., Moher, D., Greenberg, D., Augustovski, F., Briggs, A. H., Mauskopf, J., & Loder, E. (2013) · Value in Health · doi:10.1016/j.jval.2013.02.010 · Cited by 657
Braithwaite, R. S., Meltzer, D. O., King, J. T., Leslie, D., & Roberts, M. S. (2008) · Medical Care · doi:10.1097/mlr.0b013e31815c31a7 · Cited by 579
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · cited 1×
“Because the lifetime of device sensors can be prolonged from the recommended 7 days to 10 days (27) without compromising safety (28), we also conducted sensitivity analyses for the real-world use of G4 and G5 CGMs(seeSupplementaryTable4).”
BackgroundImpact of hypoglycaemia on quality of life and productivity in type 1 and type 2 diabetes
Davis, R. E., Morrissey, M., Peters, J. R., Wittrup-Jensen, K., Kennedy-Martin, T., & Currie, C. J. (2005) · Current Medical Research and Opinion · doi:10.1185/030079905x61929 · Cited by 218
Glycemic Characteristics in Continuously Monitored Patients With Type 1 and Type 2 Diabetes
Bode, B. W., Schwartz, S., Stubbs, H. A., & Block, J. E. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2361 · Cited by 137
Cariou, B., Fontaine, P., Eschwege, E., Lièvre, M., Gouet, D., Huet, D., Madani, S., Lavigne, S., & Charbonnel, B. (2015) · Diabetes & Metabolism · doi:10.1016/j.diabet.2014.10.007 · Cited by 129
Cited by
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Yapanis, M., James, S., Craig, M. E., O’Neal, D., & Ekinci, E. I. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac034 · Cited by 291
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Shah, V. N., Laffel, L. M., Wadwa, R. P., & Garg, S. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0143 · Cited by 197
Didyuk, O., Econom, N., Guardia, A., Livingston, K., & Klueh, U. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819899394 · Cited by 175
Metadata
- Authors
- Wan, W., Skandari, M. R., Minc, A., Nathan, A. G., Winn, A., Zarei, P., O’Grady, M., & Huang, E. S.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2018-04-12
- Volume
- 41
- Issue
- 6
- Pages
- 1227-1234
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2798025593
- Cited by
- 118
- References
- 17
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.