CoChat

Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study

Open access
Thabit, Hood, Prabhu, Joshi Navis, Mubita, Womba, Fullwood, Catherine, Azmi, Shazli, Urwin, Andrea, Doughty, Ian, Leelarathna, Lalantha · 2020 · Diabetes Care
Cited by 68

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: International type 1 diabetes registries have shown that HbA1c levels are highest in young people with type 1 diabetes; however, improving their glycemic control remains a challenge. We propose that use of the factory-calibrated Dexcom G6 CGM system would improve glycemic control in this cohort. RESEARCH DESIGN AND METHODS: We conducted a randomized crossover trial in young people with type 1 diabetes (16–24 years old) comparing the Dexcom G6 CGM system and self-monitoring of blood glucose (SMBG). Participants were assigned to the interventions in random order during two 8-week study periods. During SMBG, blinded continuous glucose monitoring (CGM) was worn by each participant for 10 days at the start, week 4, and week 7 of the control period. HbA1c measurements were drawn after enrollment and before and after each treatment period. The primary outcome was time in range 70–180 mg/dL. RESULTS: Time in range was significantly higher during CGM compared with control (35.7 ± 13.5% vs. 24.6 ± 9.3%; mean difference 11.1% [95% CI 7.0–15.2]; P < 0.001). CGM use reduced mean sensor glucose (219.7 ± 37.6 mg/dL vs. 251.9 ± 36.3 mg/dL; mean difference −32.2 mg/dL [95% CI −44.5 to −20.0]; P < 0.001) and time above range (61.7 ± 15.1% vs. 73.6 ± 10.4%; mean difference 11.9% [95% CI −16.4 to −7.4]; P < 0.001). HbA1c level was reduced by 0.76% (95% CI −1.1 to −0.4) (−8.5 mmol/mol [95% CI −12.4 to −4.6]; P < 0.001). Times spent below range (<70 mg/dL and <54 mg/dL) were low and comparable during both study periods. Sensor wear was 84% during the CGM period. CONCLUSIONS: CGM use in young people with type 1 diabetes improves time in target and HbA1c levels compared with SMBG.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc20-0736

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 68

Metadata

Authors
Thabit, H., Prabhu, J. N., Mubita, W., Fullwood, C., Azmi, S., Urwin, A., Doughty, I., & Leelarathna, L.
Venue
Diabetes Care
Published
2020-07-28
Volume
43
Issue
10
Pages
2537-2543
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W3045772403
Cited by
68
References
8
FWCI
7.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study. https://app.cochat.ai/papers/10.2337/dc20-0736
The paper
Thabit, H., Prabhu, J. N., Mubita, W., Fullwood, C., Azmi, S., Urwin, A., Doughty, I., & Leelarathna, L. (2020). Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study. Diabetes Care. https://doi.org/10.2337/dc20-0736

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.