Use of Factory-Calibrated Real-time Continuous Glucose Monitoring Improves Time in Target and HbA1c in a Multiethnic Cohort of Adolescents and Young Adults With Type 1 Diabetes: The MILLENNIALS Study
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: International type 1 diabetes registries have shown that HbA1c levels are highest in young people with type 1 diabetes; however, improving their glycemic control remains a challenge. We propose that use of the factory-calibrated Dexcom G6 CGM system would improve glycemic control in this cohort. RESEARCH DESIGN AND METHODS: We conducted a randomized crossover trial in young people with type 1 diabetes (16–24 years old) comparing the Dexcom G6 CGM system and self-monitoring of blood glucose (SMBG). Participants were assigned to the interventions in random order during two 8-week study periods. During SMBG, blinded continuous glucose monitoring (CGM) was worn by each participant for 10 days at the start, week 4, and week 7 of the control period. HbA1c measurements were drawn after enrollment and before and after each treatment period. The primary outcome was time in range 70–180 mg/dL. RESULTS: Time in range was significantly higher during CGM compared with control (35.7 ± 13.5% vs. 24.6 ± 9.3%; mean difference 11.1% [95% CI 7.0–15.2]; P < 0.001). CGM use reduced mean sensor glucose (219.7 ± 37.6 mg/dL vs. 251.9 ± 36.3 mg/dL; mean difference −32.2 mg/dL [95% CI −44.5 to −20.0]; P < 0.001) and time above range (61.7 ± 15.1% vs. 73.6 ± 10.4%; mean difference 11.9% [95% CI −16.4 to −7.4]; P < 0.001). HbA1c level was reduced by 0.76% (95% CI −1.1 to −0.4) (−8.5 mmol/mol [95% CI −12.4 to −4.6]; P < 0.001). Times spent below range (<70 mg/dL and <54 mg/dL) were low and comparable during both study periods. Sensor wear was 84% during the CGM period. CONCLUSIONS: CGM use in young people with type 1 diabetes improves time in target and HbA1c levels compared with SMBG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State of Type 1 Diabetes Management and Outcomes from the T1D Exchange in 2016–2018
Foster, N. C., Beck, R. W., Miller, K. M., Clements, M. A., Rickels, M. R., DiMeglio, L. A., Maahs, D. M., Tamborlane, W. V., Bergenstal, R., Smith, E., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0384 · Cited by 1,907
DiMeglio, L. A., Evans-Molina, C., & Oram, R. A. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31320-5 · Cited by 1,561
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
DeSalvo, D. J., Miller, K. M., Hermann, J. M., Maahs, D. M., Hofer, S. E., Clements, M. A., Lilienthal, E., Sherr, J. L., Tauschmann, M., Holl, R. W., et al. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12711 · Cited by 233
Beck, R. W., Riddlesworth, T. D., Ruedy, K. J., Kollman, C., Ahmann, A. J., Bergenstal, R. M., Bhargava, A., Bode, B. W., Haller, S., Kruger, D. F., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30217-6 · Cited by 119
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
Elbalshy, M., Haszard, J., Smith, H., Kuroko, S., Galland, B., Oliver, N., Shah, V., de Bock, M. I., & Wheeler, B. J. (2022) · Diabetic Medicine · doi:10.1111/dme.14854 · Cited by 104
Johnson, S. R., Holmes-Walker, D. J., Chee, M., Earnest, A., & Jones, T. W. (2022) · Diabetes Care · doi:10.2337/dc21-1666 · Cited by 86
Fantasia, K. L., Wirunsawanya, K., Lee, C., & Rizo, I. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296821995810 · Cited by 62
Lameijer, A., Lommerde, N., Dunn, T. C., Fokkert, M. J., Edens, M. A., Kao, K., Xu, Y., Gans, R. O. B., Bilo, H. J. G., & van Dijk, P. R. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108897 · Cited by 27
Short-term use of CGM in youth onset type 2 diabetes is associated with behavioral modifications
Manfredo, J., Lin, T., Gupta, R., Abiola, K., West, M., Busin, K., Tracey, J., Brown, E. A., Magge, S. N., & Wolf, R. M. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1182260 · Cited by 25
Rizos, E. C., Markozannes, G., Charitakis, N., Filis, P., Stoimeni, A. E., Nørgaard, K., Ntzani, E. E., & Tsilidis, K. K. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0599 · Cited by 21
Wang, Y., Zou, C., Na, H., Zeng, W., & Li, X. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/2851572 · Cited by 12
Alfadli, S. F., Alotaibi, Y. S., Aqdi, M. J., Almozan, L. A., Alzubaidi, Z. B., Altemani, H. A., Almutairi, S. D., Alabdullah, H. A., Almehmadi, A. A., Alanzi, A. L., et al. (2025) · Metabolism Open · doi:10.1016/j.metop.2025.100382 · Cited by 16
Metadata
- Authors
- Thabit, H., Prabhu, J. N., Mubita, W., Fullwood, C., Azmi, S., Urwin, A., Doughty, I., & Leelarathna, L.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2020-07-28
- Volume
- 43
- Issue
- 10
- Pages
- 2537-2543
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W3045772403
- Cited by
- 68
- References
- 8
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.