CoChat

Safety and Efficacy of Sustained Automated Insulin Delivery Compared With Sensor and Pump Therapy in Adults With Type 1 Diabetes at High Risk for Hypoglycemia: A Randomized Controlled Trial

Open access
Renard, Eric, Joubert, Michael, Villard, Orianne, Dreves, Bleuenn, Reznik, Yves, Farret, Anne, Place, Jerome, Breton, Marc D., Kovatchev, Boris P., iDCL Trial Research Group · 2023 · Diabetes Care
Cited by 51

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Assess the safety and efficacy of automated insulin delivery (AID) in adults with type 1 diabetes (T1D) at high risk for hypoglycemia. RESEARCH DESIGN AND METHODS: Participants were 72 adults with T1D who used an insulin pump with Clarke Hypoglycemia Perception Awareness scale score >3 and/or had severe hypoglycemia during the previous 6 months confirmed by time below range (TBR; defined as sensor glucose [SG] reading <70 mg/dL) of at least 5% during 2 weeks of blinded continuous glucose monitoring (CGM). Parallel-arm, randomized trial (2:1) of AID (Tandem t:slim ×2 with Control-IQ technology) versus CGM and pump therapy for 12 weeks. The primary outcome was TBR change from baseline. Secondary outcomes included time in target range (TIR; 70–180 mg/dL), time above range (TAR), mean SG reading, and time with glucose level <54 mg/dL. An optional 12-week extension with AID was offered to all participants. RESULTS: Compared with the sensor and pump (S&P), AID resulted in significant reduction of TBR by −3.7% (95% CI −4.8, −2.6), P < 0.001; an 8.6% increase in TIR (95% CI 5.2, 12.1), P < 0.001; and a −5.3% decrease in TAR (95% CI −87.7, −1.8), P = 0.004. Mean SG reading remained similar in the AID and S&P groups. During the 12-week extension, the effects of AID were sustained in the AID group and reproduced in the S&P group. Two severe hypoglycemic episodes occurred using AID. CONCLUSIONS: In adults with T1D at high risk for hypoglycemia, AID reduced the risk for hypoglycemia more than twofold, as quantified by TBR, while improving TIR and reducing hyperglycemia. Hence, AID is strongly recommended for this specific population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/dc23-0685

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 51

Metadata

Authors
Renard, E., Joubert, M., Villard, O., Dreves, B., Reznik, Y., Farret, A., Place, J., Breton, M. D., Kovatchev, B. P., & iDCL Trial Research Group
Venue
Diabetes Care
Published
2023-09-20
Volume
46
Issue
12
Pages
2180-2187
ISSN
  • 0149-5992 (ISSN-L)
  • 1935-5548
OpenAlex
W4386897441
Cited by
51
References
18
FWCI
8.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.